Amends 90 & 54 to Licenses NPF-39 & NPF-85,respectively, Changing TS 4.7.1.3 Requiring Stated Draining of Spray Pond Network Piping
ML20086A886
Person / Time
Site: Limerick  Constellation icon.png
Issue date: 06/01/1995
From: Stolz J
Office of Nuclear Reactor Regulation
To:
Philadelphia Electric Co
Shared Package
ML20086A889 List:
References
NPF-39-A-090, NPF-85-A-054 NUDOCS 9507050083
Download: ML20086A886 (8)


Text

e 1

't W ero y+.

t UNITE 3 SiATES j

j NUCLEAR REGULATORY COMMISSION 2

WASHINGTON, D.C. 20555-0001 f

%[..... p PHILADELPHIA ELECTRIC COMPANY DOCKET NO. 50-352 LIMERICK GENERATING STATION. UNIT 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 90 License No. NPF-39 1.

The Nuclear Regulatory Comission (the Comission) has found that:

A.

The application for amendment by Philadelphia Electric Company (the licensee) dated August 25, 1993, as supplemented by letters dated June 27, 1994, and May 5, 1995, enmplies with the~ standards and requirements of the Atomic Energy Act of 1954, as amended (the Act),

and the Commission's rules and regulations set forth in 10 CFR Chapter I;

i B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

9507050003 950601 DR ADOCK 050003 2

i,

.C-' 2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. NPF-39 is hereby amended to read as follows:

Technical Spec 1fications The Technical Specifications contained in Appendix A and the Environmental Protection Plan contained in Appendix B, as revised through Amendment No.

90, are hereby incorporated into this license.

Philadelphia Electric Company shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

3.

This license amendment is effective as of its date of issuance and shall be implemented within 30 days.

FOR THE NUCLEAR REGULATORY COMMISSION Jo F. Stolz, Directo

,Pr ject Directorate I-vision of Reactor Projects - I/II Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specification:

Date of Issuance: June 1, 1995

h 7

t g-ATTACHMENT TO LICENSE AMENDMENT NO. 90 FACILITY OPERATING LICENSE NO. NPF-39 DOCKET NO. 50-352 Replace the following page of the Appendix A Technical Specifications with the attached page. The revised page is identified by Amendment number and contains vertical. lines indicating the area of change.

Remove Insert 3/4 7-5 3/4 7-5 l

l 1

l l

1

.i

1 il,PLANTSYSTEMS ULTIMATE HEAT SINK LIMITING CONDITION FOR OPERATION 3.7.1.3 The spray pond shall be OPERABLE with:

a.

A minimum pond water level at or above elevation 250' 10" Mean Sea Level, and b.

A pond water temperature of less than or equal to 88'F.

APPLICABILITY:

OPERATIONAL CONDITIONS 1, 2, 3, 4, 5, and *.

ACTION:

With the requirements of the above specification not satisfied:

a.

In OPERATIONAL CONDITION 1, 2, or 3, be in at least HOT SHUTDOWN within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in COLD SHUTDOWN within the next 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

b.

In OPERATIONAL CONDITION 4 or 5, declare the RHRSW system and the emergency service water system inoperable and take the ACTION required by Specifications 3.7.1.1 and 3.7.1.2.

c.

In OPERATIONAL CONDITION *, declare the emergency service water system inoperable and take the ACTION required by Specification 3.7.1.2.

The provisions of Specification 3.0.3 are not applicable.

SURVEILLANCE RE0VIREMENTS j

i 4.7.1.3 The spray pond shall be determined OPERABLE:

a.

By verifying the pond water level to be greater than its limit at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

b.

By verifying the water surface temperature (within the upper two feet of the surface) to be less than or equal to 88'F:

1.

at least once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> when the spray pond temperature is greater than or equal to 80*F; and 2.

at least once per 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> when the spray pond temperature is greater than or equal to 85'F; and 3.

at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when the spray pond temperature is greater than 32*F.

c.

By verifying all piping above the frost line is drained:

1.

within one (1) hour after being used when ambient air temperature is below 40*F; or 2.

when ambient air temperature falls below 40*F if the piping has not been previously drained.

Amendment No. 25,49,90 LIMERICK - UNIT 1 3/4 7-5

V

,1 1

go.n ce:oq q

't UNITED STATES

  1. n NUCLEAR REGULATORY COMMISSION f

WASHINGTON, D.C. 206tMo01 PHILADELPHIA ELECTRIC COMPANY t

DOCKET NO. 50-353 LIMERICK GENERATING STATION. UNIT 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 54 License No. NPF-85 1.

The Nuclear Regulatory Comission (the Comission) has found that:

A.

The yplication for amendment by Philadelphia Electric Company (the licensee) dated August 25, 1993, as supplemented by letters dated June 27, 1994, and May 5, 1995, complies with the standards and i

requirements of the Atomic Energy Act of 1954, as amended (the Act),

and the Comission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.

There is reasonable assurance (1) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted i

in compliance with the Comission's regulations; D.

The issuance of this amendment will not be inimical to the comon defense and security or to the health and safety of the public; and i

E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been l

satisfied.

3,

. 2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. NPF-85 is hereby amended to read as follows:

Technical Specifications The Technical Specifications contained in Appendix A and the Environmental Protection Plan contained in Appendix B, as revised through Amendment No.

54, are hereby incorporated into this license. Philadelphia Electric Company shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

3.

This license amendment is effective as of its date of issuance and shall be implemented within 30 days.

FOR THE NUCLEAR REGULATORY COMMISSION J

F. Stolz, Direct P ject Directorate I-2 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance: June 1, 1995

3 L

ATTACHMENT TO LICENSE AMENDMENT N0. 54 FACILITY OPERATING LICENSE NO. NPF-85 DOCKET NO. 50-353 l

l Replace the following page of the Appendix A Technical Specifications with the attached page. The revised page is identified by Amendment number and j

contains vertical, lines indicating the area of change.

Remove Insert 3/4 7-5 3/4 7-5 1

1 l

I i

1 i

.-=

y y-

'2 ULTIMATE HEAT SINK i

/ @f LIMITING CONDITION FOR OPERATION i

E.

l 3.7.1.3 The spray pond shall be OPERABLE with:

l i

a.

. A minimum pond water level at or above elevation 250'-10" Mean Sea i

Level, and l

b.

A pond water temperature of less th'an or equal to 88'F.

f APPLICABILITY:

OPERATIONAL CONDITIONS 1, 2, 3, 4, 5, and *.

ACTION:

l r

With the requirements of the above specification not satisfied:

a.

In OPERATIONAL CONDITION 1, 2, or 3, be in at least HOT. SHUTDOWN within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in COLD SHUTDOWN within the next 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

t b.

In OPERATIONAL CONDITION 4 or 5, declare the RHRSW system and the emergency service water system inoperable and take the ACTION required by Specifications 3.7.1.1 and 3.7.1.2.

c.

In OPERATIONAL CONDITION *, declare the emergency service water system inoperable and take the ACTION required by Specification 3.7.1.2.

The provisions of Specification 3.0.3 are not applicable.

SURVEILLANCE REOUIREMENTS 4.7.1.3 The spray pond shall be determined OPERABLE:

a.

By verifying the pond water level to be greater than its limit at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, b.

By verifying the water surface temperature (within the upper two feet of the surface) to be less than or equal to 88'F:

1.

at least once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> when the spray pond temperature is greater than or equal to 80'F; and 2.

at least once per 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> when the spray pond temperature is greater than or equal to 85'F; and 3.

at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when the spray pond temperature is greater than 32*F.

c.

By verifying all piping above the frost line is drained:

1.

within one (1) hour after being used when ambient air temperature is below 40'F;.or 2.

when ambient air temperature falls below 40*F if the piping has not been previously drained.

oWhen handling irradiated fuel in the secondary containment.

^*"" **"

LIMERICK - UNIT 2 3/4 7-5 i

_