THIS IS TO INFORM YOU OF AN INCIDENT THAT OCCURRED AT PALISADES AT i
2000 HOURS YESTERDAY 8/28/74.
l THE INCIDENT WAS A FAILURE OF THE THREE-QUARTER INCH VENT LINE ON l
THE LETDOWN LINE JUST DOWNSTREAM OF THE LETDOWN ORIFICES.
THIS l
LINE FAILED BY CRACKING OVER 75 PERCENT OF ITS CIRCUMFERENCE JUST i
ar.mi tABOVE THE WELD TO THE LETDOWN LINE.
AT THIS TIME, THE FAILURE
. i MECHANISM IS NOT KNOWN.
AT THE TIME THE PLANT WAS IN THE PROCESS OF PLANT C00LDOWN AND WAS AT 400 DEGREES F.
THE LEAK WAS FIRST NOTED BY INCREASED CHARGING REQUIREMENTS FOLLOWING RECOVERY FROM A SIMULATED DBA TEST.
THE LETDOWN LINE WAS ISOLATED IMMEDIATELY AND NO FURTHER PROBLEM RESULTED.
THIS INCIDENT IS TENTATIVELY CALLED ABNORMAL OCCURRENCE 74-17 BASED O N ITEM C OF TECH i SPEC DEFINITIONS.
-rp 3 <W t
R B DE WITT/ J G LEWIS t
sr mi <nPALISADES PL ANT CONSUMERS POWER COMPANY
[
GW l
NNNN f
8308230071 741115 f'