ML20085D452

From kanterella
Jump to navigation Jump to search
Ro:During Routine Audit of Completed Periodic Tests,Test 22 Involving Auxiliary Feedwater Sys Not Performed as Scheduled.Test Successfully Performed on 720502.Periodic Test Status Board to Be Closely Monitored
ML20085D452
Person / Time
Site: Robinson 
Issue date: 05/16/1972
From: Utley E
CAROLINA POWER & LIGHT CO.
To: Block E
US ATOMIC ENERGY COMMISSION (AEC)
Shared Package
ML20085D421 List:
References
NUDOCS 8307250686
Download: ML20085D452 (1)


Text

"

~

~

pJ g- ~

~-

q.- 2 1 1 Carolina Power & Light Company Raleigh, North Carolina 27602 May 16, 1972 f@,

q,

,c' Robinson File No. 2-0-4-a ff, (o

' 7' b{;[

'l

~q

c. yIeyy:$

~'

.e s. m,,~ -

l >.

l :-l '/::1 Q'

\\

T,\\

i i,

?,

if~;O

~,

,y Mr. Edward J. Block, Acting Director I

Directorate of Licensing

\\

U. S. Atomic Energy Commission Washington, D. C.

20545 H. B. ROBINSON UNIT No. 2 LICENSE DPR-23 FAILURE TO PERFORM A SURVEILLANCE TEST ON Tile AUXILIARY FEEDWATER SYSTEM

Dear Mr. Block:

During a rotitine audit of the completed periodic tests, it was noted that Periodic Test No. 22 (Technical Specification Section 4.8.1 to 4.8.3), involving the Auxiliary Feedwater Systeri, had not been performed as, scheduled on April 18, 1972. This test was successfully performed on May 2, 1972 which was six days over the 25% adjustment time as stated in Technical Specifications, Section 4.0.

In an effort to prevent a re-occurrence of this violation, the periodic test status board will be monitored raore closely and the duty shift foreman will cross-check the periodic tests to be performed on his shif t against a master list which designates specific duc dates for each periodic test.

This is reported in accordance with Technical Specification 6.6.3.d.

The Company Nuclear Safety Committee will investigate this violation in accordance with Section 6.1.4.2.g.5.

Yours very truly,

- cq' f

,s'

.f E. E Utley ' ~ N Manager Bulk Power Supply j.a/

l JBM:me C f.

l 7738 8307250686 721212 PDR ADOCK 05000261 S

PDR u