ML20084R456

From kanterella
Jump to navigation Jump to search
Potential Significant Const Deficiency Rept Re Defective Capstan Springs in Mechanical Arrestors Supplied by Itt Grinnell.Initially Reported on 831024.Safety Analysis in Progress.Next Rept by 840725
ML20084R456
Person / Time
Site: Hope Creek PSEG icon.png
Issue date: 05/04/1984
From: Martin T
Public Service Enterprise Group
To: Murley T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
NUDOCS 8405220371
Download: ML20084R456 (2)


Text

..

e i

Thomas J. Martin Public Service Electric and Go: Company 80 Park Plaza Newark, N.J. 07101 201/430B316 Vic2 President Engineering and Construction May 4, 1984 Dr. Thomas E. Murley U. S. Nuclear Regulatory Commission Office of Inspection and Enforcement Region I 631 Park Avenue King of Prussia, Pennsylvania 19406 Dear Dr. Murleys POTENTIAL CONSTRUCTION DEFICIENCY DEFECTIVE CAPSTAN SPRINGS IN SilOCK ARRESTORS

!! OPE CREEK GENERATING STATION On October 24, 1983, a verbal report was made to Region I, Office of Inspection and Enforcement representative, Mr.

E.

M.

Kelly, advising of a potentially significant construction deficiency concerning defectivo capstan springs in mechanical shock arrestors supplied by ITT Grinnoll.

Interim reports woro sent to your office on November 23, 1983, and February 29, 1984.

The following interim report is provided in accordance with the requirements of 10CFR50.55(o).

Pacific Scientific has revised their list of affected snubbers supplied to llope Crook reducing the number from 101 to 87.

On April 19, 1984, our Architect /Engincor and Constructor, Dechtol, shipped 86 of the suspect snubbers to Pacific Scientific for examination and replacement of the capstan springs as required.

Bechtel is presently developing administrative controls to ensure that the one missing shock arrestor will not bo installed in any safety-related system.

8405220371 040504 PDR ADOCK 05000354 g

PDR 0

sc 29

I w

3 0

Dr. T.

E. Murley 2

5/4/84 Our safety analysis will be completed subsequent to the requisite NDE of the capstan springs, our target dato for submittal of our final report is July 25, 1984.

Very truly yours,

/f&&

C Office of Inspection and Enforcement Division of Reactor Construction Inspection Washington, D. C.

20555 NRC Resident Inspector - llope Creek P. O. Box 241 llancocks Bridge, NJ 08038 Records Center Institute of Nuclear Power Operations 1100 circle 75 Parkway, Suite 1500 Atlanta, GA 30339 l

i

%.