ML20084R265
| ML20084R265 | |
| Person / Time | |
|---|---|
| Site: | Fort Saint Vrain |
| Issue date: | 05/10/1984 |
| From: | Lee O PUBLIC SERVICE CO. OF COLORADO |
| To: | Jay Collins NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
| Shared Package | |
| ML20084R267 | List: |
| References | |
| P-84138, TAC-55053, NUDOCS 8405220260 | |
| Download: ML20084R265 (1) | |
Text
,
J
_A PUBLIC SERVICE COMPANY OF COLORADO o r n v c a.
cotonaoo aoaoi p.
- o. s o x e 4 o 16805 WCR 19 1/2, Platteville, Colorado 80651 OSCAR R. LEE VICE PRESIDENT May 10, 1984 Fort St. Vrain Unit #1 P-84138 Mr. John T. Collins, Regional Administrator
['c;-
r- =
s
' ' ~
4 Region IV
~~ o Nuclear Regulatory Commission 611 Ryan Plaza Drive MAY ! 61984 Suite 1000 Arlington, TX 76011
,p
SUBJECT:
Fort St. Vrain Dew' point Moisture Monitor Response Testing At 70% Power
REFERENCES:
(1) P-77144 (Fuller to Denise, Dated June 30,1977)
Dear Mr. Collins:
In fulfillment of the DPMM testing requirements of Fort St. Vrain Technical Specification LC0 4.9.2, please find attached the results of tests run at 70% tractor power. As explained further in the attached submittal, 70*.' power testing in lieu of 100% power testing was determined acceptable by a July 25, 1978 letter forwarded by Mr. Themis P. Spies.
Public Service Company feels the attached report along with the 5%
and 25% power reports (Reference (1)), constitute satisfactory completion of all required DPMM testing and verification that moisture monitor system response timas are acceptable under all actual operating conditions.
Nuclear Regulatory Commission review and written concurrence is requested on this subject, based on the current Technical specification requirements.
Please note that this report supports and suggests Technical Specification changes associated with the Plant Protective System moisture monitor operability requirements.
These changes will be proposed in a future submittal but should not be considered in the acceptance of this report.
If there are any questions, please contact Mr. Don Warembourg at (303) 785-2224.
Very tr ly yours, Q
8405220260 040510 DR ADOCK 05000
. R. Lee
'I j
Vice President Electric Production Attachment