Proposed TS Page 15.7.7-2,reflecting Change to Annual Monitoring Rept
ML20084Q490
Person / Time
Site: Point Beach  
Issue date: 06/01/1995
From:
WISCONSIN ELECTRIC POWER CO.
To:
Shared Package
ML20084Q488 List:
References
NUDOCS 9506080619
Download: ML20084Q490 (1)


Text

--

1 identified in the next @(il Se:f:.nnu:1 Monitoring Report.

Figures and tables in the Environmental Manual are to be revised reflecting the new sample locations.

l B.

Detection Capabilities 1.

Environmental samples shall be analyzed as specified in Table 15.7.7-2.

2.

The required detection capabilities for environmental sample analyses are tabulated in terms of the lower limits of detection (LLDs).

l 3.

If circumstances render the stated LLDs in Table 15.7.7-2 unachiev-able, the contributing factors shall be identified and described in

thi next @Iis{ Sc=l
nnu:1 Monitoring Report.

C.

Notification levels 1.

If a measured level of radioactivity in any environmental medium exceeds the notification level listed in Table 15.7.7-3, resampling 4

and/or reanalysis for confirmation shall be completed within 30 days of the determination of the anomalous result.

If the confirmed measured level of radioactivity remains above the notification level, a written report shall be submitted to the NRC in accordance with Section 15.7.8.4.B within thirty days of the confirmation. This report is not required if the measured level of radioactivity was not t

the result of plant effluents.

2.

If more than one of the radionuclides listed in Table 15.7.7-3 are detected in any environmental medium, a weighted sum calculation shall be performed if the measured concentration of a detected l

radionuclide is greater than 25% of the notification levels. For j

those radionuclides with LLDs in excess of 25% of the notification level,. a weighted sum calculation need only be performed if the reported value exceeds the LLD. The weighted sum is calculated as follows:

concentration (1)

+

concentration (2)

+...

weighted notification level (1) notification level (2) sum

)

If the calculated weighted sum is equal to or greater than 1, resampling and/or reanalysis for confirmation shall be completed within 30 days of the determination of the anomalous result.

If Unit 1 - Amendment No. 444 15.7.7-2 fp il 18, lass Hnit ?

Amantimant No. W 9506080619 950601 PDR ADOCK 05000266 P

IRC3

-