ML20084L294

From kanterella
Jump to navigation Jump to search
Monthly Operating Repts for Apr 1984
ML20084L294
Person / Time
Site: Dresden  Constellation icon.png
Issue date: 04/30/1984
From: Schroeder B, Scott D
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF ADMINISTRATION (ADM)
References
DJS-LTR:84-431, NUDOCS 8405140415
Download: ML20084L294 (13)


Text

'

OPERATING DA A REPORT DOCKET NO. 050-237

. DATE May 2, 1984 COMPLETED BY B. A. Schroedc TELEPHONE (815) 942-2920 OPERATING STATUS NOTES

1. Unit Name: Dresden II
2. Reporting Period: April. 1984 3 Licensed Thermal Power (MWt): 2,527
4. Nameplate Rating (Gross MWe): 828 5 Design Electrical Rating (Net MWe): 794
6. Maximum Dependable Capacity (Gross MWe): 812
7. Maximum Dependable Capacity (Net MWe): 772
8. If Changes Occur in Capacity Ratings (Items 3 Through 7) Since Last Report, Give Reasons:

N/A 9 Power Level to Which Restricted, if Any (Net MWe): N/A

10. Reasons For Restrictions, if Any: N/A This Month Yr-to-Date Cumulativo
11. Hours in Reporting Period 719 2903 122,423
12. Number of Hours Reactor Was Critical 719 2g03 95,127.5
13. Reactor Reserve Shutdown Hours 0 0 0
14. Hours Generator On-Line 719 2881.0 93,787.1 15 Unit Rese.rve Shutdown Hours 0 0 0
16. Gross Thermal Energy Generated (MWH) 1.774.909 6.844.806 183.539.442
17. Gross Electrical Energy Generated (MWH) 577,297 2.235',524 58,737,723
18. Net Electrical Energy Generated.(MWH) 548,112 2,128,338 55,516,602 19 Unit Service Factor 100.00 99.24 76.61
20. Unit Availability Factor 100.00 99.24 76.61
21. Unit Capacity Factor (Using MDC Net) 98.75 94.97 58.74
22. Unit Capacity Factor (Using DER Net) 96.01 92.34 57.11
23. Unit Forced Outage Rate 0.0 0.75 11.37
24. Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each):

May 19, 1984 for snubber inspection.

25. If Shut Down At End Of Report Period, Estimated Date of Startup: N/A

'l d

8405140415 840430 PENT ADOCK 05000237 R PDR

[l

OPERATING DATA REPORT DOCKET NO. 050-249 DATE May 2, 1984 COMPLETED BY B. A. Schroedd TELEPHONE rn, a aa,_,o,n i

OPERATING STATUS NOTES j

1. Unit Name: Dresden III ,
2. Reporting Period: April, 1984  :

3 Licensed Thermal Power (MWt): 2,527

4. Nameplate Rating (Gross MWe): 828
5. Design Electrical Rating (Net MWe): 794
6. Maximum Dependable Capacity (Gross MWe): 812 7 Maximum Dependable Capacity (Net MWe): 773
8. If Changes Occur in Capacity Ratings (items 3 Through 7) Since Last Report, Give Reasons:

N/A 9 Power Level to Which Restricted, if Any (Net MWe): N/A

10. Reasons For Restrictions, if Any: N/A This Month Yr-to-Date Cumul.ativo
11. Hours in Reporting Period 719 2q03 112.008
12. Number of Hours Reactor Was Critical 203.01 196.1 83.171.1 13 Reactor Reserve Shutdown Hours 0 0 0
14. Hours Generator On-Line 0 0 79 R61.I 15 Unit Reserve Shutdown Hours 0 0 o
16. Gross Thermal Energy Generated (MWH) 0 0 159.961.098 17 Gross Electrical Energy Generated (MWH) 0 0 51.952.919
18. Net Electrical Energy Generated.(MWH) -5774 -15.956 49.214.628 19 Unit Service Factor 0 0 71.30

, 20. Unit Availability Factor 0 0 71.30

21. Unit Capacity Factor (Using MDC Net) 0 0 56.84
22. Unit Capacity Factor (Using DER Net) 0 0 55.34 23 Unit Forced Outage Rate 0 0 12.66
24. Shutdowns Scheduled Over Next 6 Months (Type, Date, and DJration of Each):

N/A 25 If Shut Down At'End Of Report Period, Estimated Date of Startup: June, 1984 t .

f}

- ~. . - . - . . - . . --

DOCKET NO. 050-237 UNIT NAME Dred *:n II UNIT SHUTDOWNS AND POWER REDUCTIONS ' DATE M*y 2 1983 COMPLETED BY B. A. Schroeder TELEPHONE (815) 942-2920 REPORT MONTH APRIL. 1984 METHOD OF LICENSEE CAUSE & CORRECTIVE NO. DATE TYPEl DURATION REASON 2 SHUTTING EVENT SYSTEM COMPONENT ACTION TO (HOURS) DOWN REACTOR 3 REPORT # CODE 4 CODES PREVENT RECURRENCE None

~

+y

, w, 1 2 3 4 F: Forced Reason: Method: Exhibit G-Instructions for S: Scheduled A-Equipment Failure (Explain) 1-Manual Preparation of Data B-Maintenance or Test 2-Manual Scram Entry Sheets for Licensee C-Refueling .3-Automatic Scram Event Report ( ) File D-Regulatory Restriction 4-Other (Explain) (NUREG-0161)

E-Operator Training & License Examination '

F-Administrative '

G-Operational Error H-Other (Explain) ,

DOCKET EO. 050-249 UNIT NAME Dresden III UNIT SHUTDOWNS AND POWER REDUCTIONS DATE May 2. 1984-COMPLETED BY B. A. Schroeder TELEPHONE (815) 942-2920 -

REPORT MONTH APRIL, 1984 METHOD OF LICENSEE CAUSE & CORRECTIVE I NO. DATE TYPEl DURATION REASON 2 SHUTTING EVENT SYSTEM COMPONENT ACTION TO (HOURS) DOWN REACTOR 3 REPORT # CODE 4 CODES PREVENT RECURRENCE 8 83-9-30 S 719 C' I -- -- --

Main Turbine repair.

3 1

i i

j + s j s.

9 q

1 I

l 1

i

~

a 1 2 3 4 I F: Forced . Rea's on : Method: Exhibit G-Instructions for l S: Scheduled A-Equipment Failure (Explain) 1-Manual Preparation of Data B-Maintenance or Test 2-Manual Scram Entry Sheets for Licensee C-Refueling .3-Automatic Scram Event Report ( ) File i D-Regulatory Restriction 4-Other (Explain) (NUREC-0161) -

E-Operator Training & License Examination .

F-Administrative N G-Operational Error j H-Other (Explain) .

w - m c- g a w- *w .--+-m -

y-ww1 ---gm --r- p - = = - - , ,,y .-,y r-- , v e- -

AVERAGE DAILY UNIT POWER LEVEL _

DOCKET NO. 050-237 UillT II DATE May 2, 1983 COMPLETED 'BY B. A. Schroeder TELEPHONE (815) 942-2920 MONTH APRIL, 1984 DAY AVERAGELDAILY POWER LEVEL- DAY AVERAGE DAILY POWER LEVEL (MWe-Net) (MWe-Net) 1 717 17 790 2 762 18 761 3 775 19 788 4 786 20 782 5 783 21 756 6 789 -22 775 7 778 23 783 8 745 24 771 9 781 25 783 10 786 26 780 11 783 27 784 12 784 28 772 13 780 29 678 14 671 30 757 15 776 31 16 784

AVERAGE DAILY UNIT POWER LEVEL DOCKET NO. 050-249 UNIT III DATE May 2, 1984 COMPLETED BY B. A. Schroeder TELEPHONE (815) 942-2920 MONTH APRIL. 1984 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net) (MWe-Net) 1 0 17 o 2 o 18 0 3 0 19 0 4 0 20 0 5 0 21 0 6- 0 22 0 7 0 23 0 8 0 24 0 9 0 25 0 10' 0 26 0

< 11 0 27 0 12 0- 28 0 13 o 29 0 l

l 14 0 30 0

~~~

l 15 0 31

! 16 0 l

l-l l

l l

e DRESDEN UNIT 2 SAFETY RELATED ltAINTENANCE - APRIL, 1984 NATURE OF LER OR OUTAGE FIALFUNCTION

  • ~

EQUIITIENT  !!AINTENANCE NUllBER CAUSE RESULT CORRECTIVE ACTION Accumulator Preventive W.R. #33842 ---

N/A N/A Replaced fitting.

  1. 30-55
  1. 4 Turbine Prevent'ive W.R. #33807 ---

N/A N/A Replaced switch.

Control Valve 2B MSIV Preventive W.R. #33781 N/A N/A Replaced limit switch.

Icolttion Preventive W.R. #32908 ---

N/A N/A Installed new transmitter.

C:nd::nrer Ind., EPN

  1. LI-2-1304-2 Stby Liquid Preventive W.R. #33967 --- -

/A N/A Repacked pump per manufacturer's Crnt. Puep instructions.

Toru"5 Spray Preventive W.R. #33037 -- -

N/A N/A Overhauled motor operator and tested Vnive 2-1501- for proper operation.

19A, EPN

  1. 2-1501-19A

. O l DRESDEN UNIT 3 ,

SAFETY RELAiED MAINTENANCE - APRIL, 1984 NATURE OF LER OR OUTAGE ELWNG10N

  • EQUIP!IENT  !!AINTENANCE NUMBER CAUSE RESULT CORRECTIVE ACTION M03-1402-4B Preventive W.R. #30600 -

N/A N/A Adjusted packing.

3A LPCI Heat Preventive W.R. #27850 N/A N/A Removed and replaced heads for cleaning.

Exchanger, EPN #3-1503-A D3 Ccttle Preventive W.R. #27877 N/A N/A Re=oved and installed cattle chute for Chuto re fueling.

AO-3-2001-3 Preventive W.R. #34334 N/A N/A Repaired leaking fitting with PST sealant.

Equip =ent Drcia Dis- -

charg2 CRD Accu =u- Preventive W.R. #34283 N/A N/A Turned stem down one turn.

1rtcr 54-15 ,

(P-4)

Main Steam- Preventive W.R. #34363 N/A N/A Installed spacer washers.

line "A" D-3 Snubber #33, EPN #3-3001A-335 Rod Biceks Preventive W.R. #30799 N/A N/A Removed jumpers.

T1rma Level Preventive W.R. #33449 '

N/A N/A Reset breaker.

Indicctor, EPN #3-1640-IIB 3-202-5B Preventive W.R. #34194 N/A N/A Adjusted packing.

Packin3 Cland, EPN #3-202-5E

DRESDEN UNIT 3 SAFETY RELAIED HAINTENANCE - APRIL, 1984 UATURE OF LER OR OUTAGE HA W U ION EQUIntENT MAINTENANCE HUMBER ~CAUSE RESULT CORRECTIVE ACTION Recirculation Preventive W.R. #34197 N/A N/A Tightened packing glands.

I-Tia valve 3-202-6A AO-3-220-52 Preventive W.R. f34338 N/A N/A Tightened bolts around diaphragm.

D/W Equipment Preventive W.R. f27830 N/A N/A Closed equipment hatch.

Hatch 3 "O" Recire. Preventive W.R. #26253 N/A N/A Replaced bonnet gasket.

Pu=p Dischargi V::lve. EPN

  1. 3-202-5B U-3 CRD G-7 Preventive W.R. #32039 N/A N/A Replaced handwheel and keyway.

(26-27)

A & B Core Preventive W.R. #34190 N/A N/A Tightened cover gasket and adjusted Sprry Check packing.

Volve CRD Flcnges Preventive W.R. #34199 N/A N/A Retorqued CRD flanges.

A0-3-203-ID Preventive W.R. #34359 N/A N/A Tightened fittings.

(MSIV)

AO-3-223-1A Preventive W.R. #34362 N/A N/A Tightened union.

Core Spray Preventive W.R. #20100 N/A N/A Replaced valve with packing and lubed Manual 3-1402- stem.

CB Vnive, EPN

! #3-1402-6B l

l l

1

O DRESDEN UNIT 3 SAFETY RELATED MAINTENANCE - APRIL, 1984 UATURE OF LER OR OUTAGE  !~fALFUNCTION EQUIPMENT HAINTENANCE NUMBER CAUSE RESULT CORRECTIVE ACTION 3-220-50, EPN Preventive W.R. #20101 N/A N/A Repacked valve.

  1. 3-220-50 D-3 Wact Preventive W.R. #27874 ---

N/A N/A Replaced torus manway gasket and closed Torua Manway (bolted) cover.

D-3 Er:t Preventive W.R. #27872 ---

N/A N/A Replaced torus manway gasket and closed Toru Manway (bolted) cover.

D-3 Class 1 Preventive W.R. #30565 ---

N/A N/A Ground welds in preparation for UT Weld Grinding examination (ISI).

U-3 1501-13A Preventive W.R. #28612 N/A N/A Locked tight bonnet mounting bolts.

& B, EPN

  1. 3-1501-13A &

B LPRM Preventive W.R. #33529 -

N/A N/A Checked for proper electrical continuity.

MO-3-1501-3B, Preventive W.R. #33613 ---

-N/A N/A Found yoke loose - repaired and tested EPN #3-1501- for proper operation.

3B Racire. Pipe Preventive W.R. #32240 ---

N/A N/A Removed plug sample from recirculation Weld #28-K8, pipe weld #28-K8. Rewelded new plug in.

EPN #3-0202B-K8

SUMMARY

OF OPERATING EXPERIENCE UNIT TWO APRIL, !984 04-01 to 04-30 Unit 2 entered the month operating at a power level of 745 MWe and operated continuously throughout the entire month (with normal power reductions on weekends for surveillances), reaching a power level of 830 MWe with a capacity factor of 96.28 and an availability of 100%.

b I

?

i I'

[

I

, _ . , , , , . - - - - - _ . - - . - - -._. - - , - . . , - - - - . . , . - _ - , . - . _ , . . . , , ~ . . , - - , - - . . - , - , ~ . . - . . ,,.

SUMMARY

OF OPERATING EXPERIENCE UNIT THREE APRIL, 1984 04-01 to 04-30 Unit 3 remained off-line the entire period with the reactor critical (to maintain temperature). On May 9th, the reactor was shutdown with temperature being main-tained by use of the two recirculating water pumps.

Work on the i?.P. Turbine rotor continues. A portable oven has been erected which is being used to stress relieve and straighten the rotor. Other work includes repair of the stationary seals between stages.

The status of the unit remains "In Refuel".

s

O N Commonwealth Edison C i g (y 6) Dresden R.R. #1 - Nucle r Power St tion f

\ Morris, Illinois 80450 ,

  • Telephone 815/942-2920 i l

l May 2, 1984 ,

DJS LTR: 84-431  !

Director, Office of Inspection [

and Enforcement  !,

United States Nuclear Regulatory Commission Washington, DC 20555 Attention: Document Control Desk

Dear Sir:

Enclosed, please find Dresden Station's operating data for last month.

This information is supplied to your office per the instructions set forth in Regulatory Guide 1.16 .

Sincerely, 1

LO D. . Scott Station Superintendent Dresden Nuclear Power Station l

DJS: BAS:hjb L

Enclosure cc: Region III, Regulatory Operations, U.S. NRC Chief, Division Nuclear Safety, State of IL U.S. NRC, Document Management Branch Nuclear Licensing Administrator Nuc. Sta. Div. Vice. Pres.

Manager, Tech. Serv. Nuc. Sta.

Tech. Staff EA On-Site NRC Inspector Sta. Nuc. Eng. Dept.

l Comptro11er's Office j INPO Records Center PIP Coordinator File /NRC Op. Data File / Numerical h