AO 50-274/74-23:on 740719,low Level Switch LIS-1-263-58A Drifted Below Tech Spec Limit of 8 Inches.Switch Recalibr
ML20084K237
Person / Time
Site: Quad Cities 
Issue date: 07/20/1974
From: Gudac J
COMMONWEALTH EDISON CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML20084K236 List:
References
50-254-74-23, AO-50-254-74-23, NJK-74-167, NUDOCS 8305190229
Download: ML20084K237 (1)


Text

n

7.,-

C:rnrn:nw I!!h 8 dis:;;n 8Y Cuad-Cit:

enerating Station I

O ('k E4 Post CISc. a 216

.J

( D;%

C:rcova,Ilknois 61242 Telephone 309/654-2241 HJK-74-167 Telecopy: Region Ill, Attention:

Mr. C. Feierabend July 20, 1974 QL!lik W

e d i

J. Keppler, Reaional Director bEO Directorate of Regulatory Operations d,

( gg 197.f;;[

s Region 1il i_

qm U. S. Atomic Energy Commission 799 Roosevelt Road g

c l I,t;;23r /-j Glen Ellyn, Illinois 60137 g'"..

4 '

/s 4

kh

<7C v

[;pb [,

T Referencc: Quad-Cities Nuclear Power Station, Unit i Dccket NumSer 50-254, DPR-29, Anoendix A Sections 1.0.A.2, 3.1 Tab le 3.1.1, and 6.6.B. I.a

Dear Mr. Keppler:

L The purpose of this letter is to provide you with notification of the above referenced abnormal occurrence as required by Technical Specifications 6.6.S.1.a

.. ; d. i.. I', ;.vu n..

On July 19, 1974, with Unit One in a hot shutdown condition following a low power scram, surveillance test number ten was being performed on LIS-1-263-58A.

The setpoint was found to be 72 inches Of which corresponds to zero reactor water level. The Technical Specification limiting condition of operation is 2.6 inches reactor water level. The switch was recalibrated and functionally tested in ac-cordance with surveillance test ten.

This occurrence was discussed with Mr. C. Feierabend of your office on July 20, 1974, by telephone, p

Q Very truly yours, h

COMMONVEALTH EDISON COMPANY QUAD-ITIES tiUCLEAR POWER STATION

,n

% d! w t

J.

. Gudac j

A sistant Station Superintendent b[', 9 k

/

JHG/RAR/j eh

/,D cc:

Directorate of Licensing lLk J. S. Abel

/

G825 BBPGPcfo$$$$2 gg, segr iurs103_