' E.52 E.a #

Tele rarn western union lw IU20EC 30 nit 9: 35

"'- I VEB049(1032)(1-006028C365)PD 12/30/72 1031 ICS IPMVEIE MVN

['

b

^

ZCZC 00017 TDVE CORD 0VA ILL 54 12 30 445P CST (EY ORDERS) g EG.

NO-@Ed PMS MR BOYCE GRIER REGIONAL DIRECTOR OF US ATOMIhqMniRSION Ah.h[f '-ACE:n,'

re e cdf I EC

[)

DIRECTOR OF REG ULATORY OPER ATTDN & ""*"

Date did-71ce did

-- To REGION 3 To do unod or filed Attezpts to deliver (Indicate DA or BY) 799 ROOSEVELT ROAD GLEY ELYEN ILL REFERENCE QUADCITY NUCELAR POWER STATION DEOCET 50-254 DTR 29

^

APPENDIX A SECTION 1.0.A.2 AND 3 1 DURING ROUIEIN CALIBRATION ON CECEMBER 28, 1972 ECH OIL PRESSURE SWITCH WAS FOUND

^

TO TRIP AT LESS THAN 900 PSIG CONTRARY TO TECHNICAL SPECIFICATIONS.

rs THE SWITCH IRIPPED AT 890PSIG AND HAS BEEN RECALIBRATEL TO GREATER THAN 900PSIG UD gy c E1M1 (f54W)

N KALVIANAKIS QUADCITY NUCELAR POWER STATION i

L t

i

(

I L

0305130310 730111 f

i PDR ADOCK 05000254

~

S PDR

-.f i

l (

w.mi m 1

-