ML20084J241

From kanterella
Jump to navigation Jump to search
Preliminary AO-73-15:on 730725,during Closure Timing & Scram Checks,Msiv NS04B Closed in Less than 3 S.Caused by Insufficient Oil in Hydraulic Dashpot.Seal Cartridge Assembly Replaced
ML20084J241
Person / Time
Site: Oyster Creek
Issue date: 07/25/1973
From: Carroll J
JERSEY CENTRAL POWER & LIGHT CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
AO-73-15, NUDOCS 8305120266
Download: ML20084J241 (4)


Text

.

O O

Tot Jarms P. O'Rolliy Directorate of Regtslaton) Operations Region I 631 Park Avenuo King of Prussia, Pennsylvania 19406 e

Frome Jnreny Central Pcwer & Light Company Oyster Creek tiuclear Generating Station Dockot M50-219 Forked River, tiew Jersey 09731 Subjects Abnorcal occurrence Report 73-15 The following is a prolindnary report boing submitted

  • 1n complianco with' tha Technical Spccificat1ons paragraph 6.6.2.

Prellminav) Approval s 0./$ jswdD,.-

msm fJ.T.CarrolloJr.

Dato ccs Mr. A. Giarhusso j',r

'\\

i

,v 8305120266 730725 DR ADOCK 05000219 PDR

Abnormal Occurrence O

O Report No. 73-15 SUBJECTS Closuto of Main Steam Isolation Valve NSO4B in icss then throo seconds.

This event is considered to be an abnormal occurrenco as defined in the Technical Spocifications, paragraph 1.lSA.

Notification of this event as required by the Technical Specificacions, paragraph 6.6.2.a, was made to ABC Region I, Directorato of Regulatory Operations, by shone on Wednesday, July 25,1973, at 10:30 a.m. and by telecopier on nodnesday, July 25, 1973 at SITUATION.t Prior to conducting a plant startup, full closuro timing and scram checks were being conducted on all four Main Steam Isolation Valves.

In testing valva NSO43, closure tim was masured to be 2.6 seconds whereas the Technical specification limit in paragraph 4.5.I.2 is three seconds. No additional tining checks wore conducted, both of which indicated tha valve to be closing faster than the above limit.

CAUSEs The hydraulic dashpot was found to contain insufficient oil. Approxi~

mately four quarts of oil woro added, whereupon satisfactor,) closure timos were obtained. However, while stroking the valve, oil was detected leaking along the operating shaft out of the Seal Cartridge Assetrhiy. This apparently was the cause for tha loss of oil.

!Partinent data 'is as followst Vendor Fluid Power Dist.

Seal Cartridge Assembly: N661-20-V.

O O

REMEDTAL ACTION:

The seal cartridge assembly was replacada oli was added'to the hydraulic cylindor, valvo timing adjusted, and the Main Steam Isolation Valve was returned to service.

SAFETY SIGNIFICAN mt The minimum valvo closato cine limit of thrco seconds is based upon limiting the vessci peak prcssura during the isolation valve closure transient analysis such that the main steam safety valves do not lift.

The offact of tho observed decreased tico for valvo closure would be to increase the vessel peak pressure during the transient. In this 0

situation, the plant was shutdown and <212 F, conscquently the sig-nificance of the fast valvo closuto was nil. Since the closura timas for the valves in the other steam lino vero normalo the offects of the fast closure time for NSO9B would probably have been min'imal ii the plant had been at power.

}

e e

io cu........

i inAu

...s

(,

Licensce:

Jersey Cenp 31 Power & Light Co.

'-~

i.

t, 11.13. Thornburg, cAic Docket No.:

50-219 Chief. FS&EB j'.

Abnormal Occurrence:

A0 73-15 s

t o <w.m..n4.,a.o unims acurans RO:HQ (h) o I

DR Central Files (1) oAiE Regulatory Standards

,3)

J, Dir. of Licensing (131 forwarded in accordance with RO Manual chanter 10*.

To (n.m..no uo.o va nAi.s At=Aans RO Files Central Ma'i1 & Files The action taken by the licensee is considered Unit mt approp the next insocction a*s annropriate.

Confessof FROM (N.mo.no wa.O RtuAnns the report have been foruarded to the PDR, Local i

R.['T.' /, Wdd*W Carlson, Chief PDR, NSIC, DTIE and State representativos. The Facility Operations Branch licensce will submit a 10 day written report to reat e.Q.

DAiE 7/31/73 Licensing.

U$E OTHER $1DC FOR ADDITIONAL REMARKS CPO:1itO.en-7 s

s.

,,-.....,y*,_

a b, *:, ~

. y -(

~

  • ;g,.,.

,.~;

~*..: g'. -

~.

L*, t..

.s.L.

.. e 'i_., *

> ~ ff *,. y;

$,A =, _...,.

'.,j- -

r

",s,

.. R. *;, -

r h'.

'".k

, s b:[

' h-) ~ *. :y.., *. s.

2

,b.

... ~ -

t,.

v.;.

r.

~ _

.. f

.m

,'.f......

T: '.

.,.:.*z '

..:qaf

....Q'..'-

W.:q.-

l4.. ' ::. ~.'

~

.?

r.

. *d

,.{?e,

.' ' '. N,[ '.

.Y'.., u

..f :

. '(

r.),*n,

'v e

.s

..e.,-

c-O,?.*c.

f.f r.' 5 '.: 'N.-.

.,:W: l4:

..c.

.y.y.._ '

i.r. 7,: ;.

s g[;

' b

)

q,p.

, ? '. ' ;j

r.Ll,

'W'

__.;.3. -

..-4/p..

..A C.

. Q.

i:.

'.?

.0. -

c.

r,;:

~ y,:

.s

.. ~. '.

?.

' ~ :-

.1.*.

. p,..

s,e-g,',? 3 N*-

U,::

,.-llr 33NVIhW 3 ih n5wg

~

T'?'

.4

.WH03 ADRy3.asoiy g g y..:,?.:

r

.y =-

~

.x

. <a.. s,..,

. :w w.;.-

s y

. ~.

  • f.',
  • h*g

, 5 j d,

. ~..

6*

.g*.

.t 03A0333 e

e g

m.

P.mm w -.GWW &S.

_ _ _ _ _ _ _ _ _ _ _ _.