Tot Jancs P. O'Rollly Directorato of Regulatory Operations Region I 631 Park Avenuo King of Prussia, Pennsylvania, 19406 From Jerscy Central Power & Light Company Oyster Czcek Nuc1 car Generating Station Docket 150-219 Forked River, New Jctsey 08731
Subject:
Abnornal Occurrence Report 73-21 Following is a preliminary report being submitted in compliance with the Technical Specifications paragraph G.6.2.
Preliminary Approyal:
0_- [, <!nfr#G.9/10/73
. T. Carroll, Jr. V 'Dato cc Mr. A. Giambusso e
/
~
i
(',
p
/,q}
I b
8305100033 730910 PDR ADOCK 05000219 PDR S
9 e
A
- ~
~
Dato: 9/10/73 Tine: 3:00 a.c.
\\_J
+
6 i
ABNOR!1\\L OCCURRENCE REPORT NO. 73-21
SUBJECT:
Failure of 21 liydraulic Shock and Sway Arrestors on piping systems in the Drywell, including units on both Core Spray and both Isolation Condenser loops.
O This event is considered to be an abnormal occurrence as defined in the Technical Specifications, paragraph 1.15.D.
Notification of this event as required by the Technical Specifications, para-t i
graph 6.6.2.a, was made to AEC Regipn I, Directorate of Regulatory l
l I
Operations, by telephone on Monday, September 10, 1973, at 12:45 p.m., and personally to Mr. E. Greeman on bbnday, September 10, 1973.
SITUATION:
The p1 ant was shutdown on September 8,1973 for the purpose of inspecting the llydraulic Shock and Sway Arrestors located on piping systens throughout the Drywell.
l CAUSE:
The snubbers were made inoperable due to a loss of hydraulic fluid.
REMEDIAL ACTION:
The failed Ilydrauli'c Shock and Sway Arrestors were replaced using snubbers ' rebuilt with seal kits supplied by the Bergen Paterson Pipe Support Company.
The new seals are of'a different type, which according to Bergen Paterson, will provide a longer seal life.
6
x O
Abnomal Occurrence Esport No. 73-21 Srptonber 10, 1973-o SAFE'IY ' SIGNI FI CANCE :
The loss of snubber operability resulted in a reduction in the ability of the plant to safely survive a design bases carthquake.
'Ihc failures were such that they affected both Core Spray and both Emergency Condenser Systems, f
e 0
0 e
e a 4 e
e O
O e
0 6
m 9
e
).
4
~ y e
~
g O.,o/,I/
O t.Me-Date:
9/10/73 Prepared by: [-
/
h
MEMO ROUTE SLIP e.. Mc-,,<%. sin u.swiansi<gn 5:2 => a mi th'..
r.< c.au,,:ac2 r o, tcii.
,,ar,,a4,,,,,a r
,,3,..,,,
r, ia,1,m., ion.
io et m2.ncuan; imiiAt.
traux 5 Licensce:
Jersey Centr E Pow *r & Light Comp;ny H. D. Thornburg, cArc Docket No.:
50-219 Chief, FS&EB Abnomal Occurrence:
AO 73-21 TO (Name and unst)
I"8 fl AA 5 R i u a R,.5 RO:HQ (5)
DR Central Files (1)
The attached report from the subject licensee is DATE Regulatory Standards
- 3)
Dir. of Licensing (13 forwarded in accordance with RO Manual Chanter 1000 i
1O (NI,ne and unit)/
IMllAL$
StMARKS R0 Files v The action taken by the licensee is considered J. Tillou, RO:I oATE appropriate.
Followup will be performed during the next inspection as appropriate.
Copies of r pea e4.m ana ua )
atwAR=s i
the report have been forwarded to the PDR, Local D, L. Caphton, Senior PDR, NSIC, DTIE and State representatives. The Rractor Inspector, BWR Section licensee will submit a 10 day writteti report to FHDN E.04 CATE 9/18/73 Licensing.
USE OTHLR $IDE FOR ADDITION AL REMARKS CPO 19110 - 445-4(9
.S' o
(
I
~ I it.
ija 1
. 7,7 L 5;.
t
, e n
Og'*
ss I$
he e
e
&