I June 14, 1974

/

(M j JUN18197(. > /ElMs238%

cs;

'XR;r w.c w.= m n,. s; y

w

t i't. sy,

?.

'Q Eld 42.ks

,{

Mr. John _F. O' Leary, Director TN Directorate of Licensin6 l

Office of Regulation 50-259 U.S. Atomic Energy Ccamission Washington,_DC 20545

Dear I/r. O' Leary:

tem 1ESSEE VALLEY AUTHCRITY - EROWNS FERRY HUCLEAR PIAIIT UNIT 1 -

DOCKET I 0. 50-259 - FACILITY OPERATING LICENSE DPR ABHORI?AL OCCURREI:CE REPORT EFAO-743c74 The enclosed report is to provide details concerning a main steamline isolation valve malfunction and is submitted in accordance

[

with Appendix A to Regulatory Guide 1.16, Revision 1, Octcber 1973 This event occurred on Ercuns Ferry I!uclear Plant unit 1 on June 6, h

197 Very truly yours, TEMESSEE VALLEY AUTHCPlTY

/

E. F. Thomas Director of Power Prcduction Enclosure CC(Enclosure):

Mr. Norman C. Moceley, Director Region II Regulatcry Operations Office, USAEC 230 Peachtree Street,174., Suite 818 Atlanta, Georgia 3C303 V

'b' L

/

&j( (f,/

8305040581 740614

~

4 PDR ADDCK 05000259 S

PDR g

COPY SENT REGION b

c --

u g

i

+

t.

O O

i ABI RMAL CCURREIICE RSPORT l

r f

Report No.:

BFAO-7438W Report Date: June 14, 1974 Occurrence Date:

June 6, 1974

(

Facility: Browns Ferry nuclear Plant unit 1 Identification of Occurrence

~

d On June 6,1974, main steonline "B" outboard isolation valve FCV l-27 closed

)

in 1.7. seconds. The required closing time for this volve is not less than 3 1

cr more than 5 seconds.

y Conditions Prior to Occurrence The reactor was at approximately 70-percent power.

3IV startup test No. 25 x

was in pro 6ress.

j f

Designation of Arnarent Cause of Occurrence An inspection of the ISIV revealed hydraulic fluid leaking past the lower seals on the velve dashpot cylinder. This resulted in a low fluid level in the dashpot cylinder permitting the valve to close too fast. The cause of the lecking fluid was determined to be a denaged seal.

Analysis of Occu*rence All of the !3IV's vere tested at this time and found to close within the 3-to second range except for the "3" outboerd isolation valve FCV l-27.

A review of the transient trace nunber 137 showed the powcr increese experienced with the

?

slightAy faster closure of FCV 1-27 was appro::ime.te17.3,0 percent.

This was the h

same increase experienced by the closure of the other'ESIV's. Therefore, there i

was no unsafe operating condition.

L Hn Corrective Action l}

-Immediate corrective action was to shut the in* board isolation velve in the "B" steamline.

At about 1,800 hours0.00926 days <br />0.222 hours <br />0.00132 weeks <br />3.044e-4 months <br /> on-June 6, a steen tunnel entry was made and the dashpot on f

131V FCV l-27 was filled with E. F. Ecu~.hton Co. SJ.FE :')620 oil ed the velv

)

reset to close in L.7 seconds. This interin corrective e.ction rs to permh several hours of testing to be accon:plished before scheduled roretor trip after which percanent corrective action would be taken. At 2,301 hours0.00348 days <br />0.0836 hours <br />4.976852e-4 weeks <br />1.145305e-4 months <br /> on June 6, the reactor tripped as a result of a startup test.

(

i On June 7,new seals were instc11cd in the dachpot cylinder. The cylinder was j

refilled and the valve adjusted to closc s 4.8~ seconds.

(

i

+

1

r,

(~'.(N

. V' J

'v' fd Failure Data

~

See the following previous abnor.al occurrence reports:

l 1.

Report No. u?AO-742U--Two main steam isolation valves (FCV 1-26 and j

FCV l-51) failed to meet the 3-to-5-second closing time on January 8, 1974, on unit 1.

2.

Report No. 3FAO-7hl2W--:hin steam isolation velve FCV l-27 failed to meet the 3-to-5-second closing time on !.hrch 8, 1974, on unit 1.

l J

Valve Data:

a 1.

3/4" auto-panent flou control valve, knob-type; auto-ponent drawing Ho. FK-750.

2.

26" main steam isolation valve:

s Manufa:turer: Atrood and :7.orrill Concary Salen, Massachusetts l

Valve Drawing Ho.:

20351-E, Sheets 1 and 2.

)

1\\