DUKE POWER GOMPm j
P.O. BOX 33180 CHARLOTTE, N.O. 28242 HALB. TUCKER TELEPHOVE
- =
17 Pj2 : tl 5 April 9, 1984 dir. James P. O'Reilly, Regional Administrator U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30303 Re: McGuire Nuclear Station 50-370[
Docket Nos.
Dear Mr. O'Reilly:
This letter is a Special Report submitted as required by McGuire Nuclear Station Technical Specification 3.7.8.
Duke Power Company has a design change planned which modifies the total number of mechanical snubbers identified in the Technical Specifications. A description of the planned change follows.
Modification No. MG-10880 (Unit 1)
This modification deletes one mechanical snubber in a portion of the Safety Injection (NI) System. This snubber is being deleted as part of the Boron Injection Tank (BIT) removal. A License Amendment request was submitted on December 12, 1983 to delete the Technical Specifications associated with the BIT. A revised stress analysis has been performed without the deleted snubber which showed that stresses are within acceptable values.
A revision to Technical Specification 3.7.8 to reflect the above modification will be submitted with the next license amendment request.
Please advise if there arc any questions regarding this matter.
Very truly yours, Cgb'a Hal B. Tucker CAC:glb cc:
Mr. Harold R. Denton, Director Mr. W. T.' Orders Office of Nuclear Reactor Regulation NRC Resident Inspector U. S. Nuclear Regulatory Commission-McGuire Nuclear Station Washington, D. C. 20555 Attention:
Ms. E. G. Adensam, Chief Licensing Branch.No. 4 8405070123 840409 PDR ADOCK 05000369 A
S PDR ifF
-