-r TENNESSEE VALLEY AUTHORITY CHATTANOOGA TENNESSEE 374ol 400 Chestnut Street Tower II December 19, 1983 BLRD-50-439/83-25 U.S. Nuclear Regulatory Commission Region II Attn:

Mr. James P. O'Reilly, Regional Administrator 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30303

Dear Mr. O'Reilly:

BELLEFONTE NUCLEAR PLANT UNIT 2 - DRAWING DISCREPANCY POR INCORE MONITOR 1

TANK SLEEVES - BLRD-50-439/83 SECOND INTERIM REPORT The subject deficiency was initially reported to NRC-0IE Inspector Linda Watson on April 5,1983 in accordance with 10 CFR 50.55(e) as NCR 2317 This was followed by our interim report dated May 4,1983 Enclosed is our second interim report. We expect to submit our next report by January 23, 1985.

If you have any questions, please get in touch with R. H. Shell at FTS 858-2688.

Very truly yours, TENNESSEE VALLEY AUTHORITY L. M. Mills, anager Nuclear Licensing 4

Enclosure cc:

Mr. Richard C. DeYoung, Director (Enclosure)

Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Records Center (Enclosure)

Institute of Nuclear Power Operations 1100 Circle 75 Parkway, Suite 1500 Atlanta, Saorgia 30339 84010307 PDR ADUCK06 831219 S

05000439 PDR

.6 e,

1983-TVA 50 ANNIVERSARY

  1. 7 An Equal Opportunity Employer g{

L

--a

+

w

.A

=

a Lsw.

m:.,2u, A

-~--


s-1.6.

.~

n ENCLOSURE BELLEFONTE NUCLEAR PLANT UNIT 2 DRAWING DISCREPANCY FOR INCORE MONITOR TANK SLEEVES BLRD-50-439/83-25 i

10 CFR 50.55(e)

NCR 2317 SECOND INTERIM REPORT Description of Deficiency The unit 2 Reactor Building Incore Monitor tank sleeves, for incore piping, (El 639.01 Mark 1 and 2 sleeves) are 18'-2-3/4" and 1'-9-1/2" from the center line of the reactor building. On the unit 1 plan view, the i'

dimensions are 18'-2-3/4" and 2'-3-1/2".

As a result, the unit 2 sleeves in the incore tank are installed 6" west of their intended location.

Interim Progress The nonconformance has been referred to the Division of Engineering Design with a recommended disposition to use the tank sleeves in their present configurations.

Babcock and Wilcox was notitied of this condition and was asked to review the "use-as-is" disposition as it deviates from their acceptance criteria. Babcock and Wilcox recommended that TVA install the sleeves in the correct location.

TVA would prefer the "use-as-is" solution and has purchased " dummies" which, upon delivery, will be inserted in each unit and the insertion and withdrawal forces monitored. TVA will submit the test results to Babcock and Wilcox for their review and approval.