Ro:Design Changes Planned to Modify Total Number of Hydraulic & Mechanical Snubbers in Tech Specs,Including Rerouting Auxiliary Steam Drains Containing Valves 1SA56 & 59 & Disconnecting Boron Injection Tank from Piping
ML20083B471
Person / Time
Site: McGuire, Mcguire  
Issue date: 12/12/1983
From: Tucker H
DUKE POWER CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
NUDOCS 8312210167
Download: ML20083B471 (2)


Text

- - - ____-________-

Duxc POWER GoxPAxy

' P.o. nox 33189 CIIAHLoTTE. N.C. 28242 II AL 15. TUCKER Tra.zenosz vu.m recommwr (704) 373-4531 2b'ece"mblz912Nd85 0

"" * ' ~ "*"

Mr. James P. O'Reilly, Regional Administrator U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30303 Re: McGuire Nuclear Station Docket Nos. 50-369, 50-370

Dear Mr. O'Reilly:

This letter is a Special Report submitted as required by McGuire Nuclear Station Technical Specification 3.7.8.

Duke Power Company has design changes planned which modify the total number of hydraulic and mechanical snubbers in the Technical Specifications. A description of each of the planned changes follows.

Modification No. MG-888 (Unit 1)

This modification will involve rerouting the auxiliary steam (SA) drains containing valves 1SA56 and ISA59 which currently drain the Auxiliary Feedwater Pump Turbine Exhaust to the "B" and "C" Main Steam line drains. The new one inch drain lines will be Class B piping and will tie into the Main Steam System (SM) on the two inch drain lines containing valves 1SM89 and 1SM95.

This modification involves the addition of five mechanical snubbers to the SA system.

l Modification No MG-20033 (Unit 2) l l

This modification involves rerouting the Reactor Makeup Water Storage Tank overflow piping to the inlet header for Recycle Holdup Tanks A and B.

As a result of this change, six mechanical snubbers in the Chemical and Volume Control System will be deleted.

Modification No. MG-880 (Unit 1)

This modification disconnects the Boron Injection Tank from the piping in the Chemical and Volume Control System and Safety Injection Systems. As a result, two hydraulic snubbers will be deleted and one mechanical snubber will be added.

A revision to Technical Specification 3.7.8 to reflect the above modifications will be submitted with the next license amendment request.

OifiG M. ropy Z623 8312210167 831212 f

PDRADOCK05000g

//d S

Lt

.Mr. James P. O'Reilly, Regional Administrator December 12, 1983 Page 2~

Please advise if there are any questions regarding this matter.

Very truly yours, c& l k

Hal B. Tucker GAC/php cc:

-Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Attention:

Ms. E. G. Adensam, Chief Licensing Branch No. 4 i

j.

Mr.- W. T. Orders NRC Resident Inspector McGuire Nuclear Station 4

i s

F 1