m -----lE E!Els O
4=C247445205 10/12/83 ICS IPPMTZZ CSP'PHAB 9147396654 PGP TOPT BLCFANAN'NY 189 10-12 0105P EST g
_ c '5 o
O, e
huCLEAR REGLLATORY COPkISSION ATTN DR fFCPAS MLALEY O
,O aEGIONAL ACRINISTRATOR REGIONiCNE 631 PARK AVE KING OF RRLSSIA PA 19406 g
O e
O CEAR OR klRLEY, O
CN CCTOBER 11, 1983, h!TP THE PLAAf Im TrE CCLD SHUTC0hN CChDITIch, O
IT WAS DETERPINEC TFAT TFE DESIGN CF TFE DRAIN L!hES C A O.1339) CN TFE O
ACCUPULATCRS IS SUCF TFAT A SEIS. HIC AND A NONSE!$FIC LINE ARE CONNECTEC EY A NCRPALLY CPEN, >ANUAL VALVE. THIS PCTENTIALLY CCLLC O
O LEAC TO A LCSS OF FLUIC FRCM TFE SEISMIC LIAE IF TFE NCNSEISHIC LIhE IS ASSUMEC TC FAIL DURING AN EARTFCUAKE. TFIS EVENT FALLS UADER,THE JURISDICTICA 0F TECHNICAL SPECIFICAT!ch 6.9.1.7.I, WHICF ACCRESSES O
O STRUCTURES CR COPPCNENTS REQUIRING CORRECTIVE MEASLRES TO PREVENT CPERATION IN A MANNER LESS CCNSERVATIVE THAh THAT ASSUPED IN TFE ACCIDENT ANALYSIS. THIS CONDITION FAS BEEN Ih!TIALLY OCRRECTED BY O
O REVISION TC CPERATING PRCCEDURES TC HAINTAIN THE VALVE NORPALLY CLCSED DLRING CPERATION. RESIDENT INSPECTOR'T KENNY hA! NCTIFIEC AT 0800 HOURS CN CCTOBER 12, 1983 TFIS TELEGRAF SERVES At THE 24 POUR O
O A0TIFICATICN REGUIRED BY TECHNICAL SPECIFICATION 6.9.1.7 JOSEPH E RUSSELL FOR J0FN C BRONS RESIDENT PANAGER O