I I

'N Comm:nw alth Edis:n I

,/

\\ Braidwood Nuclear Po'<cr Stetion j

(

.x/

/ Routa C1, Box 84

\\

7 Braceville, illinois 00407

\\Ms/ Telephone 815/4584801

)

1 September 10, 1991 DW/91-0736 1

Director, Office of Resource Management United States Nuclear Regulatory Commission Washington, D.C.

20555 AT1H Document Control Desk Gentlemen Enclosed for your information is the Monthly Performance Report covering firaidwood Nuclear Power Station for the period August 1 through August 31, 1991.

Very truly yours, c)- J2+L$

5 K.L.Kofron['l-Station Manager Braidwood Nuclear Station KLK/EWC/cif (227/ZDB5G)

Attachments j

ces A.

B. Davis, NRC, Region III NRC Resident Inspector Braidwood Ill. Dept. of Nuclear Safety H, J. Wallace K. L. Graesser T. J. Kovach Nuclear Fuel Services, PWR Plant Support INPO Records Center Performance Monitoring Group, Tech Staff Draidwood Station Nuclear Group, Tech Staff Braidwood Station ER. Pulsifer - USNRC A. R. Checca D. R. Eggett - Nuclear Engineering Department

/' /' { F' 9109160317 910931 PDR ADOCK 05000456 i\\

R PDR 1

e' s

a BRAIDWOOD NUCLEAR PCWER STATION UNIT 1 AND UNIT 2 MONTIILY PERFORMANCE REPORT COMMONWEALTH EDIS'H COMPANY NRC DOCKET NO. 050-456, LICENSE NO. NPF-72 HRC DOCKET NO. 050-457, LICENSE NO. NPT-77

f. '

I.

Monthly Report for Draldwood Unit 1 A.

Jiwignaly_n fJptIAting_E xperienc e Breldwood Unit 1 entered the month of August in routine operation. On August 4, load was reduced for maintenance on a reactor' coolant pump._ followlng the maintenance the unit returned to normal operations until August 11, when there was a load reduction to clean the condensate stralnors. On August 15, load was again reduced to inspect a water box for tube leakage.

Following the inspection the unit returned to normal operation until August 25, when a load reduction occursed for repairs on a turbine governor valve. Following repairs the unit operated routinely the remainder of the month.

L (227/ZD850)3

B.

OPERA 11HG._ DATA _EIPDRT DOCKET Ho.:

50-456 UNIT Draldwood 1 DATE:

09/10/91 COMPILED BY:

C. E. Pershey TELErilONE:

(815)458-2801 est. 2173 OPERATING STATUS 1.

Reporting Period: August, 1991 Gross llours:

744 2.

Currently Authorized Power Level (MWt):

3411 Design Electrical Rating (MWe-gross):

1175 Design Electrical Rating (MWe-net):

1120

. Max Dependable Capacity (MWe-gross):

1175 Max Dependable Capacity (MWe-not/

1120 3.

Power level to whi,ch restricted (If Any): None 4.

Reasons for restriction (If Any): None I1UBJiQtfIll YR TO DATE._CU){ULhTIVI_

5.

Report period Hours:

7mQ 5011 _.

21000 6.

Ilours Reactor Critical 74(xQ 251111 19.4 & 4__

7.

RX Reserve Shutdown Hours:

0,_Q

_,_Q,D 0

0__,

1 8.

flours Generator on Lines 7&D

___2.5 & B 1914Ll._.

9.

Unit Reserve Shutdown Hours:

010 0_t0 0.0 10.

Gross Thermal Energy (MWH):

2092 8.5 L._ $15112.4 55104111_

11.

Gross E3ec. Energy (MWlOs

_.215A00 21kla20 19111thL__

12.

Het Elec. Energy (MWH):

683514.__.

2110131 _ 18452110

- 13.

Reactor Service Factor 1&Q thS __

71.L 34.

Reactor Availability Tactors 1&Q thS 72.d 15.

Unit Service factort 100.0 4h2 70iL [

16.

Unit Availability Factor 10DtQ (L2 70 L 1

17.

Unit Capacity Factor (MDC net):

8210 _

Jh8

_hQi9 I

18.

Unit Capacity Factor (DER net):

01 0 32.41 60.9 f

19.

Unit Forced Outage. Rate:

0.Q 3h2 1.3. 2 20.

Unit Forced Oucage Hours:

OQ

_142h1 290hL [

t 21.

. Shutdowns Scheduled Over Next 6 Months: None

' 22.-

If Shutdown at End of Report Period, i

Estimated Date of Startups i

i i

l-( 227/ZC'85G) 4 I

.yv e-.-

rv y

.e.e-,--_..

- - =

s -

.er--

,-cvm-mr v*

> + --e

-- -i w

  • -w e--

---eo

=

+

F - -' ' - * - ' -

.-______._..___.--_..__.__..-__.____.___.____._.m._.,

i

~

C.

MIR AGI_DAILLUli1LR ELIMIILLIVIL_ LOG DOCKET No.

50-456 UNIT Draidwood 1 DATE:

09/10/91 COMPILED BY C. E. Pershey TELEPil0NE:

(015)458-2001 ext. 2173 MONTils August, 1991 1.

950 17.

6$2 2.

929-18.

All 3.

796 19, 91 2 4.

417 20.

1002__ _ _

5.

608 21.

1006

6..

961 22.

_373 7,

971 23.

979 8.

935 24.

83 1 9

10A1 25.

7Aji 10.

1027 2 6. -

1Q94 11.

B.Q 6 27.

1109 12.

913 28.

1107 13.

1A12 29.

11.06 14.

1&Q2 30.

1105 15.

652 31.

1Q15 116.

6 5)_

INSTRUCTIONS On _this form list the ave" age daily unit power level in MWe-Net for each day in the reporting month. Compute to the nearest whole megawatt.

These figures'will be used to plot a graph'for each reporting month.-

Note that when maximum dependable capacity is used for~the net electrical rating of_the unit there may be occasions when the daily average power level exceeds the 100% line (or the restricted power level line).

In such cases the average daily unit power output sheet should be footnoted to explain the apparent anomaly.

(227/ZD85G)5-

[-

D.

ETIT "M 35/ REDUCTIONS DOCKET NO.: 50-455 UNIT: Braidwood 1 DATE: 09/10/91 COMPILED BY: C. E. Pershey TELEPHONE: (815)458-2801,

ext. 2173 REPORT PERIOD: August, 1991

_b'2-QA"3 1T73 HRLIRS FIA_ERt! liUERR IJE_FJM3IR SYSTEM COMPCNENT CAUSE & CORPJCTIVE ACTIC!i T3 FE N RECUFRFI{CE 9

910804 F 0.0 A

5 N/A AB P

Reduced, load for lubrication of the 1A reactor coolant pump lower bearing.

10 910811 F 0.0 B

5 N/A SD MO Reduced load to clean the condensate / condensate booster strainers.

11 910815 F 0.0' B

5 N/A KE CCND Reduced load for condenser water box tube inspection. No leaking tubes were identified.

12 910325 F 0.0 A.

5 N/A TB FLT Redsted load to repair a turbine ganerator governor valve. Replaced a blocked internal filter on the valve.

SUMMARY

TIPE REASON METHOD 52W_ & COMPOtENT F-Forced A-Equipment Failure 1 - Manual Exhibit F & H S-Scheduled B-Maint or Test 2 - Manual Scram Instructions for Preparation of C-Refueling 3 - Auto Scram Data Entry Sheet

.D-Regulatory Restriction 4 - Continued Licensee Event Report E-Operator Training & License Examination 5 - Reduced Load (LER) File (NUREG-0161)

F-Administration 9 - Other G-Oper Error H-Other (227/ZDBSG)6

1jiI1l

,1

,ljj ll<!!

'lll1\\i l

I

)i

~

+

NO I i T

a P

r I

v.

R r.

~

C SF EC D

NC IT TI ND AN LO PC M

I CD t

O i

s EN mO o

n n

U o

I t

T i

t A

s a

L e

r I

g n

e.

OL n

p.

NA a

ea o

h E

e iM c

R v

d I

l e

U a

t O

v D

a E

E r

R f,

ST e

e EA n

G i

VU E

e e

N l

LT N

g n

I e

AC O.

o T

R VA N

e N

H

/

e C

y s

P t

n E

e e

R f

c a

i 7

E S

L

)

U G.

I M

O 5

8 I.

M, D

1 2

Z.

/.

7

. 2 2

E

(

j.

l g

5 s

,i eii ti

!id-ij 5I

'ikll

sfi 1'

4i; 4f 191 I<;(

, i

.l

i j

r t

r.

LICENSEE EVENT _BItQRIS.UR12.3

?

The following is a tabular summary of all Licensee Event Reports i

submitted during the reportlog period, August I through August 31, 1991.

This Information is provided pursuant to the reportable occurrence reporting requirements as set forth in 10 CFR $0.73.

I Licensee Event Report Reppl.LXumher_.

Date Iltle_cLOccurrence

{

I 91-007-08-14-91 Rod Control System failure causes-shutdown bank control rods to be in I

a condition prohibited by Technical Specifications.

F 91-008 08-28-91 Scaling deficiency of Over

{

Temperature Delta Temperature 6ue l

to preservice design error.

t k

A P

I l

l I

i

?

I i

- I t

r b

I

{

I r

I 4

i

?

i 1

(227/ZD85G)8 I

?

?

.. -. -. _ =,,, _ _. _

-____,,.-.-~_m,

- _. _ -. :-~.-..-

-. - _ _ -. _ _, _ ~..

~ _

J l

8 a

l 6

I.

Monthly Report for Braldwood Unit 2 l

EWnatary of O Ataling.lzpadence j

A.

P Braldwood Unit 2 tilppeu on August 1, due to a failure in j

the conttol rod drive systitm.

Following repairs the unit was returned to service on August 5.

The remainder of the i

month the unit operated in a routine coast down in preparation for a scheduled September, 1991 tofuel outage.

l t

t 1

i 4 4 (227/ZD85G)9

i 9

11.

OPIRAT1HGJATA EEPDRI DOCKET Ho.:

50-457 UNITS Braidwood 2 DATE:

09/10/91 COMPILED I:Y:

C. E. Pershey TELEPil0NE:

(815)458-2001 ext. 2173 OPERATING STATUS 1.

Reporting Period: August, 1991 Gross llours:

744 2.

Currently Authorized Power Level (MWL):

3411 Design Electrical Rating (MWe-gross):

1175 Design Electrical Rating (MWe-net):

1120 Max Dependable Capacity (MWe-gross):

1175 Max Dependable Capacity (MWe-net):

11LO 3.

Power level-to which restracted (if Any): None i

4.

Reasons for restriction (If Any): l lone

{

IlllS_MONTil YR..IRJATE CUMULAT1YE-i f

5.

. Report perAod Hours:

711,4 5831

_ _ 25152 _

6.

Ilours Reactor Critical:

09%)

55DLS 21h20 A l

l 7.

RX Reserve Shutdown Hours:

0.D Q.i.Q Q4D

8..

Hours Generator on Line 65L3 Sh11t4

__.21 tit 1 f

9.

Unit Reserve Shutdown llours:

0,0 Q,9 0.0 j

10.

Gross Thermal Energy (MWil):

_1186212.._ 17220526 _ 626D0511 _ j 11.

Gross Elec. Energy (MWH):

__511115 -

53151D8_._. 2 1 12 0 k R _.

I 12.

Net Elec. Energy (MWH):

_537.157 5661242_

2Q1912.22 13.

Reactor Service factor 9LL E l.

Bh3 -f 14.

Reactor Avallability Factorn 914L 95.7 BLS j

15.

Unit Service factor 8 8.L R.2 8542 16-Unit Availability Tactor 00.tL 91 S 15.2 1

17.

Unit Capacity Factor (MDC net):

hiiL Jima 72d f

18.

Unit Capacity ractor (DER net):

___ Di.L ES 72d 19.

Unit Forced Outage Rate:

1116 51 it1 k

1

-20.

Unit forced Outage Hours:

01d._ __ _,2SL5 91L2 I

f 21.

Shutdowns Scheduled Over Next 6 Months September 1991 - Refuel Outage j

22.

If Shutdown at End of Report Period,

[

Estimated Date of Startups i

t i

. (227/ZD85G)10

-,n,

,n

..n,-c,,n.-.,,,,m, n...-....

,,... + -,,

-.--,,,..-....-n-,w.c.,

i C.

AVER.* GLDMLL1!1111 H ELI'OME R_LEVIL_ LOC DOCKET Ho.t 50-457 UNIT:

liraidwood 2 DATE:

09/10/91 COMPILED IiY:

C. E. Pershey TELEPiloNE :

(B15)458-2801 ext. 2173 MONTH:

August, 1991 1.

961 17.

OffL 2.

- 1) _

18.

DB2 3.

-15 19.

111 4.

-15 20.

0.57 5.

50 21.

B17 _

6.

(AL 22.

BA1._

7.

691 23.

S30 8.

_B7] _.

24.

013 _

9.

931_.

25.

60L 10.

933 26.

194 _

11.

332 27

_ ___._210. __._

12.

__214 28.

713 13.

891 29.

757 14.

_350 30.

__129 lb.

63 5 31.

719 16.

. 0M INSTRUCTIONS On this form list the average daily unit power level in MWe-Net for e..ch day in the reportlag month. Compute to the nearest whole megewett.

These figures will b3 used to plot a graph for each reporting month.

Note that when maximum dependable capacity is used for the net electrical rating of the unit there may be occasions when the daily average power level exceeds the 100% line (or the restricted power 'evel line).

In such cases the average daily unit power output sheet should be footnoted to explain the apparent anomaly.

(227/ZD85G)11

s

  • D.

133IT SEiME/_ rep _UCTIONS DOCKET NO.: 50-457 UNIT: Braidwood 2 DATS: 09/10/91 COMPILED BT: C.

E. Pershey TELEFHONE: (815)458-2801 ext. 2173

-REPORT PERIOD:

August, 1991

_.HQ._

DAIE 2XPI li m REAS.RH METHOD LEILEMBIR SXSIDi CCMECRICfI CAUSE & CORRECTIVE ACTICN._TO PREVENT RECHERENCE 8

910801 F 86.1 A

3 91-003 AA CTR Reactor trip occurred due to a rapid power decrease brought on by the failure of the control rod drive system which resulted in numerous control rods being inserted into the core.

The cause was the failure of the 2 BD slave cycler binary counter circuit board which was replaced.

SUMMARY

ee***************

TTPE REASON METHOD ST N COMPONENT F-Forced-J.-Equipment Failure 1 - Manual Exhibit F & H S-Scheduled B-Maint or Test 2 - Manual' Scram Instructions for Preparation of C-Refueling 3 - Auto Scram Data Entry Sheet D-Regulatory Restriction 4 - Continued Licensee Event Report E-Operator Trainino & License Examination 5 - Reduced Load (LER) File (NUREG-0161)

{

F-Administration 9 - Other G-Oper Error H-Other (227/ZD85G)12

g..

t 2

+

E.-

UNIOUE EEPORTING REOUIREMENTS'- UNIT 2 j j 1.

Safety / Relief valve operations.

4'

}

VALVES NO & TYPE PLANT DESCRIPTION

[:

M ACUATED ACTUATIDH CCNDITION

QF EVENT il

{

None 2.

Licensee generated. chang 7s'to GDCH.

None (227/ZD85G)13

I e

i j

+

r.

LICL11SEE EVINLREPDRTS._ _LMIL2 The following is a tabular summary of all Licensee Event. Reports submitted during the reporting period, August I through August 30, 1991.

[

This information is provided pursuant to the reportable occurrence l

reportlng requirements ao set forth in 10 CPR 50.73.

l k

Licensee Event Report l

ReparLNwnhet.

Date Iltle_nL0ccurrence i

91-003 06-28-91 Reactor Trip caused by rod control system failure.

E F