M Y NIAGARA RuMOHAWK NIAGARA MOHAWK POWER CORPORATION /300 ERIE BOULEVARD WEST, SYRACUSE, N.Y.13202/ TELEPHONE (315) 474-1511 October 18, 1983 (7573)

Mr. R. W. Starostecki, Director U.S. Nuclear Regulatory Commission Region I Division of Project and Resident Programs 631 Park Avenue King of Prussia, PA 19406 Re: Nine Mile Point Unit 2 Docket No. 50-410

Dear Mr. Starostecki:

Enclosed is a final report in accordance with 10CFR50.55(e) for the problem concerning environmental and/or seismic qualification documentation of certain control room equipment.

This condition was reported by telephone to Mr. W. Baunack of your staff on September 21, 1982 and was followed by an interim report on October 15, 1982 and July 11, 1983.

Very truly yours, Vice President Nuclear Engineering & Licensing CVM/TL:ja Enclosure xc: Director of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, DC 20555 i

Mr. R. Gramm, Resident Inspector I

8311010380 831018 PDR ADOCK 05000410 S

PDR x

jhN}

NIAGARA MOHAWK POWER CORPORATION NINE MILE POINT UNIT 2 DOCKET NO. 50-410 Final Report for a Problem Concerning Environmental and/or Seismic Qualification Documentation of Certain Control Room Eculpment Description of the Deficiency A Niagara Mohawk Power Corporation Quality Assurance review of design record files at General Electric Company revealed that sufficient supporting environmental and/or seismic qualification documentation did not exist for certain control room equipment.

The control room equipment is as follows:

1. GE Type 185 Position Indicator (Environmental & Seismic)
2. GE Type CR28208 Relay (Environmantal)
3. Eagle Signal Cycle Flex Timer (Seismic)
4. GE CR105D Contactor (Environmental)
5. Cutler Hammer Type 10250T Control Switch (Environmental)
6. Master Specialties Switch & Light Unit (Seismic)
7. Bailey Type 701 Controller (Environmental)
8. Bailey Type 701 Square Root Extraitor (Environmental)
9. Bailey Type 701 Summer (Environmental)
10. Bailey Type 701 Alarm Unit (Environmental)
11. Bailey Type 701 Flow Controller (Environmental)
12. Riley Temperature Switch (Environmental)
13. GE Range Switch (Environmental)
14. Automatic Electric Series BQA Relay (Environmental & Seismic)
15. Eagle Signal Multipulse Timer (Environmental & Seismic)
16. Westronics Recorder (Environmental & Seismic)
17. GE Vertical Meter Type 180 (Environmental)

Corrective Actions Since the reporting of this problem, General Electric has provided sufficient supporting documentation to quality items 1 through 13 of the above equipment to IEEE 323-1971 and/or IEEE 344-1971. This documentation is in the design record files at General Electric in California for review.

Items 14 and 15, which were not originally scheduled by General Electric for eauipment qualification, have been placed in the B0P Active Device Qualification Program to close these items.

In the July 11, 1983 interim report,-it was stated that the qualification-documentation for items 16 and 17 was under review by General Electric. Since that time, General Electric has provided sufficient supporting documentation to qualify the remaining items 16 and 17.

This documentation is in the design record files at General Electric in California for review.