DOCKET NO. 50 - 277

==-

__=-

DATE AUGUST 22, 1983 Rgvistd 8/26/83 COBPLETED BY PHILADELPHIA ELECTRIC COMPANY

)

W.H.ALDEN ENGINEER-IN-CHARGE LICENSING SECTION GENERATION DIVISION-NUCLEAR TELEPHONE (215) 841-5022 OPERATING STATUS

1. UNIT NAME: PEACH BOTTOM UNIT 2 l NOTES: UNIT 2 EXPERIENCED l

g g

2. REPORTING PERIOD:

JULY, 1983 l

ONE FORCED l

g

3. LICENSED THERNAL POWER (BUT) :

3293 i

SHUTDOWN.

l l

l

4. N15EPLATE RATING (GROSS HWE) :

1152 l

l g

g

5. DESIGN ELECTRICAL RATING (NET MWE):

1065 l

l g

g

6. M11IK05 DEPENDABLE CAPACITY (GROSS BRE) : 1098 3

l g

7. 51I15U5 DEPENDABLE CAPACITY (NET BWE):

1051 l

l

8. IF CH ANGES OCCUR IN CAPACITY BATINGS (ITEMS NUMBER 3 THROUGH 7) SINCE LAST REPORT, GIVE REASONS:
9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET BWE) :
10. REASONS FOR RESTRICTIONS, IF ANY:

THIS EONTH YB-TO-DATE CUMULATITE

11. HOURS IH REPORTING PERIOD 744 5,087 79,535
12. NUMBER OF HOURS REACTOR WAS CRITICAL 93.3 3,918.1 59,007.8
13. REACTOR RESERTE SHUTDOWN HOURS 0.0 0.0 0.0
14. HOURS GENERATOR ON-LINE 91.0 3,834.8 57,383.7
15. UNIT RESERTE SHUTDOWN HOURS 0.0 0.0 0.0
16. GROSS THERMAL ENERGY GENERATED (MWH) 274,704 12,187,155 168,696,127
17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 96,800 4,029,130 55,549,640
18. NET ELECTRICAL ENERGY GENERATED (MWB) 86,990 3,879,972 53,265,121
19. UNIT SERVICE FACTOR 12.2 75.4 72.1
20. UNIT AVAILABILITY FACTOR 12.2 75.4 72.1
21. UDIT CAPACITY FACTOR (USING MDC NET) 11.1 72.6 63.7
22. UNIT CAPACITY. FACTOR (USING DER NET).

_ 11.0

.71.6-.

62.9

23. UNIT FORCED OUTAGE RATE 87.8 21.3 8.7

_=-_

24. SHUTDOWNS SCHEDULED OVER NEIT 6 MONTHS (TYPE, DATE, AND DURATION OF EACH) :

REFUELING-MAINTEN ANCE OUTAGE BEGINNING 2/04/84 FOR 13 WEEKS.

25. IF S30TDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP: 9/12/83
26. UNITS IN TEST STATUS (PRIOR TO COMMERCIAL OPERATION):

FORECLST ACHIEVED INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION 8310200263 831013 PDR ADOCK 05000277 R

PDR

s b

s

)

UNIT SHUTDONNS AND PONER REDUCTIONS DOCKET NO. 50 - 277 UNIT MARE PEACH BOTT05 UNIT 2 DATE AUGUST 22, 1983 Revised 8/26/83 REPORT MONTH JULY, 1983 COMPLETED BY PHILADELPHIA ELECTRIC COEPANY l

E.H.ALDEN ENGINEER-IN-CHARGE LICENSING SECTION GENERATION DIVISION-NUCLEAR TELEPHONE (215) 841-5022 l

l l

l l

l l NETHOD OF l LICENSEE l SYSTEM lCORPONENTI CAUSE AND CORRECTIVE l

ITYPEl DURATION l REASON l SHUTTING DOWNl EVENT l CODE I CODE I ACTION TO N3.l DATE l (1) l (HOURS) [

g2) l REACTOR (3) l BEPORT # l (4) l (5) l PREVENT RECURRENCE 1

I I

i 1

1 I

l i

18 l 830704 i F l 653.0 l

B l 1

l NA l CF l PIPEXX l BULLETIN 83-02 IGSCC PIPE IhSPECTION l

l l

l l

l l

l l AND REPAIR IMPLEMENTATION.

I 1

l l

1 I

i 1

l I

1 l 653.0 l

l l

l 1

l (1)

(2)

(3)

(4)

F - FORCED REASON METHOD EIHIBIT C - INSTRUCTIONS S - SCHEDULED A - EQUIPMENT FAILURE (EIPLAIN) 1 - MANUAL FOR PREPARATION OF DATA B - HAINTENANCE OR TEST 2 - MANUAL SCRAM.

ENTRY SHEETS FOR LICENSEE C - REFUELING 3 - ARTonATIC SCRAR.

EVENT REPORT (LER)

D - REGULATORY RESTRICTION 4 - OTHER (EIPLAIN)

FILE (NUR EG-0161)

E - OPER& TOR TRAINING + LICENSE EIAMINATION F - ADMINISTRATIVE (5)

G - OPERATIONAL ERROR (EIPLAIN)

H - OTHER (EIPLAIN)

EIBIBIT I - SAME SOURCE wI

- - - - - - -