Amend 21 to License NPF-12,changing Tech Specs to Transfer Surveillance Requirements from Svc Water Sys to Reactor Cooling Water Sys
ML20080L866
Person / Time
Site: Summer South Carolina Electric & Gas Company icon.png
Issue date: 02/03/1984
From: Adensam E
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20080L869 List:
References
NUDOCS 8402170075
Download: ML20080L866 (6)


Text

,.

f* " "'*I UNITED STATES g.

4, NUCLEAR REGULATORY COMMISSION j

W ASHINGTON, D. C. 20555 a-e

(...../

SOUTH CAROLINA ELECTRIC & GAS COMPANY SOUTH CAROLINA PUBLIC SERVICE AUTHORITY DOCKET NO. 50-395 VIRGIL C. SUMMER NUCLEAR STATION, UNIT NO. 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 21 License No. NPF-12 1.

The Nuclear Regulatory Comission (the Comission) has found that:

A.

The application for amendment to the Virgil C. Sumer Nuclear Station, Unit No. 1 (the facility) Facility Operating License No. NPF-12 filed by the South Carolina Electric & Gas Company acting for itself and South Carolina Public Service Authority (the licensees), dated July 22, 1983, and amended September 20, 1983, complies with the standards and reouirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's regulations as set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, as amended, the provisions of the Act, and the regulations of the Commission; C.

There is reasonable assurance: (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations set forth in 10 CFR Chapter I; D.

The issuance of this license amendment will not be inimical to the commen defense and security or to the health and safety of the public; 9

E.

The issuance of this license amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is hereby amended by page changes to the Technical Specifications as indicated in the attachments to this license amendment and paragraph 2.C(2) of Facility Operating License No. NPF-12 is hereby amended to read as follows:

(2). Technical Specifications The Technical Specifications contained in Appendix A, as revised through Amendment No. 21, are hereby incorporated into this license.

South Carolina Electric & Gas Company shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

8402170075 840203 PDR ADOCK 05000395 P

PDR

a 3.

This license amendment-is effective as of its date of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION (h

Elinor G. Adensam, Chief Licensing Branch No. 4 Division of Licensing

Enclosure:

Technical Specification Changes Date ofsIssuance: February 3, 1984

.C;ffkt0 Ldk:D[

' LQ#jggk LB#, L-MDunpan:eb JHopk1ns 1.2,./rM1 EAdelsam T ovak 1/J(o/84 1/g /84~

1/g//P4 1/ l /84 pM84 0

ATTACHMENT TO LICENSE AMENDMENT NO.

21 FACILITY OPERATING LICENSE NO. NPF-12 DOCKET NO. 50-395 Replace the following pages of the Appendix "A" Technical Specifications with the enclosed pages. The revised pages are identified by Amendment number and contain vertical lines indicating the area of change. The corresponding over-leaf pages are also provided to maintain document completeness.

Amended Overleaf Page Page 3/4 6-14a(new page) 3/4 7-12 3/4 7-11 t

_ =

CONTAINMENT SYSTEMS SURVEILLANCE REQUIREMENTS (Continued) 3.

At least once per 18 months during shutdown, by verifying that each automatic valve servicing safety related equipment actuates to its correct position on a simulated SI test signal or on an ESFLS, as applicable.

4.

At least once per 18 months, by verifying that each service water system booster pump starts automatically on a safety injection signal.

4 1

i 150MMER - UNIT 1 3/4 6-14a Amendment No. 21

~

PLANT SYSTEMS 3/4.7.4-SERVICE WATER SYSTEM LIMITING CONDITION FOR OPERATION 3.7.4 At least two independent service water loops shall be OPERABLE.

APPLICABILITY:

MODES 1, 2, 3 and 4.

ACTION:

With only one service water loop OPERABLE, restore at least two loops to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTOOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

SURVEILLANCE REQUIREMENTS 4.7.4 At least two service water loops shall be demonstrated OPERABLE:

a.

At.least once per 31 days by verifying that each valve (manual, power operated or automatic) servicing safety related equipment that is not locked, sealed, or otherwise secured in position, is in its correct position.

SUMMER - UNIT 1 3/4 7-12 Amendment No. 21

PLANT SYSTEMS 3/4.T.3 COMPONENT COOLING WATER SYSTEM LIMITING CONDITION FOR OPERATION 3.7.3 At least two independent component cooling water loops shall be OPERABLE.

APPLICABILITY:

MODES 1, 2, 3 and 4.

ACTION:

With only one component cooling water loop OPERABLE, restore at least two loops to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

SURVEILLANCE REQUIREMENTS 4.7.3 At least two component cooling water loops shall be demonstrated OPERABLE:

a.

At least once per 31 days by verifying that each valve (manual, power operated or automatic) servicing safety related equipment that is not locked, sealed, or otherwise secured in position, is in its correct position.

SUMMER - UNIT 1 3/4 7-11

,.