PRESENT TECHNICAL SPECIFICATION CONTAINMENT SYSTEMS 3/4.6.4 COMBUSTIBLE GAS CON-~gt LIMITING CONDITION FOR OPERATION 3.6.4.1 Two independent containment hydrogen analyzers shall be OPERABLE.

APPLICABILITY:

MODES 1 and 2.

ACTION:

With one hydrogen analyzer inoperable, restore the inoperable analyzer to OPERABLE status within 30 days or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

SURVEILLANCE REQUIREMENTS 4.6.4.1 Each hydrogen analyzer shall be demonstrated OPERABLE at least once per 92 days on a STAGGERED TEST BASIS by performing a CHANNEL CALBIBRATION using sample gases containing.

E a.

Zero volume percent hydrogen, balance nitrogen, and b.

Four volume percent (nominal) hyrogen, balance nitrogen.

l ARKANSAS - UNIT 2 3/4 6-22 Amendment No.

C310030340 830927 PDR ADOCK 05000368 P

PDR

PROPOSED TECHNICAL SPECIFICATION CONTAINMENT SYSTEMS 3/4.6.4 COMBUSTIRLE GAS CONTROL LIMITING CONDITION FOR OPERATION 3.6.4.1 Two independent containment hydrogen analyzers shall be OPERABLE.

APPLICABILITY:

MODES 1 and 2.

ACTION:

With one hydrogen analyzer incperable, restore the inoperable analyzer to OPERABLE status within 30 days or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

J SURVEILLANCE REQUIREMENTS 4.6.4.1 Each hydrogen analyzer shall be demonstrated OPERABLE at least once per 92 days on a STAGGERED TEST BASIS by performing a CHANNEL CALBIBRATION using sample gases containing.

a.

Zero volume percent hydrogen, balance nitrogen, and b.

Ten volume percent (nominal) hyrogen, balance nitrogen.

t i

l ARKANSAS - UNIT 2 3/4 6-22 Amendment No.

r l

PRESENT TECHNICAL SPECIFICATION TABLE 3.3-9 REMOTE SHUTDOWN MONITORING INSTRUMENTATION MINIMUM READOUT MEASUREMENT CHANNELS INSTRUMENT LOCATION RANGE OPERABLE

-8 1.

Logarithmic Neutron Channel 2C80 10

- 200%

1 2.

Startup Channel 2C80 1 - 10 cps 1

3.

Reactor Trip Breaker Indication OPEN-CLOSE 1/ trip breaker 4.

Reactor Coolant Cold Leg Temperature 2C80 0 - 600*F 1

5.

Pressurizer Pressure 2C80 0 - 3000 psia 1

6.

Pressurizer Level 2C80 0 - 100%

1 7.

Steam Generator Pressure 2C80 0 - 1200 psia 1/ steam generator 8.

Steam Genertaor Level 2C80 and Local (at EFW Valves Control) 0 -100%

1/ steam generator 9.

Shutdown Cooling Flow Rate 2C80 0 - 100%

1 10.

Condensate Storage Tank Level 2C80 0 - 100%

1 ARKANSAS - UNIT 2 3/4 3-37 Amendment No.

l PROPOSED TECHNICAL SPECIFICATION TABLE 3.3-9 i

REMOTE SHUTDOWN MONITORING INSTRUMENTATION 3

i t

MINIMUM READOUT CHANNELS INSTRUMENT LOCATION OPERABLE i

1.

Logarithmic Neutron Channel 2C80 1

2.

Startup Channel 2C80 1

3.

Reactor Trip Breaker Indication 1/ Trip Breaker 4.

Reactor Coolant Cold Leg Temperature 2C80 1

5.

Pressurizer Pressure 2C80 1

6.

Pressurizer Level 2C80 1

l 7.

Steam Generator Pressure 2C80 1/ Steam Generator 8.

Steam Generator Level 2C80 and Local 1/ Steam Generator (at EFW Valves Control) 9.

Shutdown Cooling Flow Rate 2C80 1

s 10.

Condensate Storage Tank Level 2C80 1

i L

i e

l ARKANSAS - UNIT 2 3/4 3-37 Amendment No.

f L

4

-, _ ~ -,

... _.. - _. -,. ~. -,... -, -. -. - _, -. _....,.. -...... _,

,,_ -. _.. -,. -.. - - - - -.