,4 TEST RESULTS REPORT

[

{-

PROCEDURE NO._

91HF-1RC01 PROCE6URE IITLE RCS Expansion Measurements REVISION AT THE ColiMENCEMENT OF TESTING _

0 DATO 4-6-83 REVISION AT COMPLETION OF TESTIN'G 0

DATE 4-6-83

+

LATEST TEST CILO'CE NOTICE NO.

08 DATE 6-25-83 DATES OF TEST PERFOR)%NCE 4-11 7-15-83 PAGE 1 OF 3

f Review and Approval of Test Results PREPARED BY:

jy e

DATE: 7 83 TECHNICAL REVIEW gh DATE: ~/- 26~- 83 GROUP SUPERVISO REVIEV:

2, DATE: 7-17-8,3 v-TEST WORKI:C CROUP MEETING NO!EER:

DATE:

PLANT REVIEW BOARD MEETII:G NC1BER:

DATE:

QUALITY ASSURANCE REVIEW:

DATE:

(Required for Test Respits Reports not reviewed by TUG)

STARTUP 1% NAGER APPROVAL:

DATE:

8402080123 831116 e

PDR FDIA 54-b7Y GARDE 83-609 PDR

---,e w

e

--m

,e--

n m

w-r-o-

--g,

-s

~

91hi-Ikt01 A. TEST PURPOSE AND SCOPE:

O

~

Esv. O TCN 8 Pag 2 2 cf 3 Tha purpora of this test w s to demonstrate the unobstructed freedom of the RCS to expand and contract verify correct sizing of various RCS support shims.during plant heatup and cooldo

(

included in this test were all cajor RCS components including RCS piping B. COMPLEMENTARY TESTS:

90HF-12201 Precore Hot Functional test C. TEST DESCRIPTION:

At the various test plateaus RCS components were observed for even expansion by:

a.) visual observation b.) go no-go measurements c.) measurements at predetermined locations These measurements were compared to the original cold ambient measure-ments and also against each other to assure that no component was locked up.

Feeler gages, vernier calipers, used.to obtain the measuremente. tape measures and similar hand tools were Cr;.pacitance probes were used on an lower lateral supports. experimental basis to measure the gaps at the Reactor Ve Additionally, thermo couples were installed to measure temperature at the top and bottom of the Reactor support column.

C. TEST EVENTS:

(

Prerequisite sign offs were started April 11, 1983 and were completed on 05-09-83.

Initial ambient measurements were started on 05-09-83 and final ambient measurements were completed 07-13-83.

Throughout the heatup and cooldown to major problems were observed.

was minor interference with insulation being deformed at There the Steam Generator key areas and at the top of the Pressurizer, and some of the small piping coming off the RCPs was' restricted from moving.

Additional problems were bolts on pressurizer key shims. interference of RCP 2A motor cooler with a the above problems:

The following SFRs were written to document SFR #

DESCRIPTIO_N 1RC-092 RCP 2A motor cooler IRC-105 RCP IRC-106 1B bleed of piping RCP IRC-110 2A pump casing drain IRC-111 pressurizer mirror insulation IRC-115 miss'ing bolts on pressurizer shim plate 1RC-120 pressurizer #2 keyway RCP 1RC-122 2B bleed off piping RCP IRC-121 2B casing vent RCP ISG-137 2A bleed off piping S/G #1 mirror insulation ISG-138 S/G #2 mirror insulation All required measuremen's were obtained to facilitate sizing final shims.

for the steam generato. sliding base cross stops and for the lower RV

, lateral supports.

any new 91HF-1RC01

-[

Rev. O TCN 8 4

Pags 3 of 3 t

,(

D. TEST EVENTS (cont'd):

.Due'to the unscheduled cooldowns and subsequent heatups it was found acceptable to delete the 460 and 260 F cooldown plateaus. TCN 08 reflects this change in the procedure. During the above mentioned cooldowns and heatups the RCS was closely monitored visualIy and by actual' measurements.

'Ihese measurements are documented as part of. the test Icg. The procedure performed-very well in achieving its. goals and mostly only minor changes were required.; A total of 8 TCNs were required and are listed below.

TCN #

Scope /Non Scope Description 01 scope change snubber acceptance criteria 02 scope add additional appendices 03 non scope delete note with regard to 24 hr. time period prior to start of test 04 non scope interchange of available control room instrumentation 05 non scope add additional measuring tools 06 scope add Reactor Coolant Pumps "V" dimensions 07 non scope to correct saveral tgpos 08 scope delete 460 F and 260 F cooldown plateaus.

E. TEST RESULTS:

Obtained measurements fell well within the required acceptance criteria with the exception of dimension 'LL' of the #2 pressurizer key at the 565 F plateaus which has been documented by TERs 01 and 02 and SFR-1RC-115.* The system responded well and repeatability thru the various heatup / cooldown cycles was excellent. One of the installed capacitance probes failed at the final ambient plateau (TER03). This was only for supplemental data and had no

'effect on the test results.

l; I

F. CONCLUSION:

'As installed the RCS expanded as was expected with no binding or sticking of the major components. Movements were as expected and after cooldown all components returned.to their starting position within a 1/16". The system as installed will perform as designed.

1 C. REComCNDATIONS:

Based on the results of the test, no retesting of the system is required with the exception of areas where additional shims will be installed and which will be tested in accordance with Post-Core Hot Functional procedure 73HF-1RC07. The procedure as written and the methods employed to obtain the measurements were more than adequate and no changes are recommended. Based on the above approval of the test results is recommended.

Retest will be conducted during Post-Core Hot Functional Testing.