Text

e 4

~ . .

m r

PUBLIC SERVICE COMPANY OF COLORADO f P. o. sox e4o . o t w v c m, COLORADO eO201 h OSCAR R. LEE 16805 WCR 19 1/2, Platteville, Colorado 80651 VICE PRES 40E947 December 30, 1983 Fort St. Vrain Unit #1 P-834M*[d@ W/ P M

[

Mr. John T. Collins, Regional A6ninistrator '

Jef - 4 M Region IV Nuclear Regulatory Commission -

S 611 Ryan Plaza Drive Suite 1000 Arlington, TX 76011 Docket No. 50-267

SUBJECT:

Proposed Technical Specification Changes - In . Service Inspection and Testing Requirements

REFERENCE:

P-83195, Brey to Collins, dated June 1, 1983

Dear Mr. Collins:

This letter is to propose changes to the Fort St. Vrain Technical Specifications concerning the In-Service Inspection (ISI) and Testing requirements as outlined in the referenced letter. A summary of the proposed changes is provided in Attachment 1, and the proposed changes themselves are provided in Attachment 2. Please note that due to the insertion of additional requirements in existing specifications, certain pages are included because of page renumbering only.

Attachment 3 contains the safety analysis report for the proposed changes. This report concludes that since the proposed changes do not result from maaifications to plant equipment nor involve reductions in the margins of safety, no unreviewed safety question is raised. Therefore, the proposed changes involve no significant hazards considerations.

'O OI 8401270140 831230 PDR ADOCK 05000267 P PDR 2

r--

Attachment 4 is provided to summarize a detailed review of the adequacy of the applicable Technical Specification Surveillance Requirements for the Fort St. Vrain reactor auxiliary systems important to safety and not addressed in Amendment No. 33 to the Operating License.

In accordance with the provisions of 10 CFR 170, we believe that the proposed changes are for Class III deemed to involve no safety hazards considerations.

A check in the amount of 54000.00 is enclosed for fee payment.

If ' you have any questions, please contact Mr. Don Warembourg at (303)785-2224.

Very truly yours, hhh

0. R. Lee Vice President Electric Production Attachments cc: Albert J. Hazle, Colorado Department of Health ORL/dkh