ML20079G344

From kanterella
Jump to navigation Jump to search
Final Deficiency Rept Re Use of Uncertified Computer Program to Analyze Rock Movement,Initially Reported 820426.Job- Specific Certification of MARC-CDC Computer Program Performed.Test Runs Showed Satisfactory Results
ML20079G344
Person / Time
Site: Nine Mile Point Constellation icon.png
Issue date: 05/26/1982
From: Rhode G
NIAGARA MOHAWK POWER CORP.
To: Starostecki R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
10CFR-050.55E, 10CFR-50.55E, NUDOCS 8206080407
Download: ML20079G344 (2)


Text

.. .

Y NIAGARA NuMOHAWK NIAGARA MOHAWK POWER CORPORATION /300 ER!E BOULEVARD WEST, SYRACUSE. N.Y 13202/ TELEPHONE (315) 474-1511 May 26, 1982 U.S. Nuclear Regulatory Commission Region I Attention: Mr. R. W. Starostecki, Director Division of Resident and Project Inspection 631 Park Avenue King of Prussia, PA 19406 Re: Nine Mile Point Unit 2 Docket No. 50-410

Dear Mr. Starostecki:

Enclosed is a final report in accordance with 10 CFR 50.55(e) for the potentially reportable deficiency regarding the use of an uncertified computer program used to analyze for rock movement. This condition was reported by telephone to Mr. H. Kister, of your staff, on April 26, 1982.

Very truly yours, NIAGARA M0 HAWK POWER CORPORATION O, s /:' 9

/ h ., & & N S D

_ J erald K. ode Senior Vice Presi ent PEF:ja Enclosure xt: Director of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Mr. R. D. Schulz, Resident Inspector 8206080407 820526 PDR ADOCK 05000410 S PDR I

NI AGARA M0 HAWK POWER CORPORATION Nine Mile Point Unit 2 Docket No. 50-410 Final Report for a Potentially Reportable Deficiency Under 10 CFR 50.55(e)

Regarding an Uncertified Computer Program

(

Description of the Deficiency During cn audit of our geologic consultant, Dames and Moore, dccumentation was not available to verify that the MARC-CDC computer program as modified by them was certified in accordance with their Quality Assurance Program requirements. Since the modified Marc-CDC computer program was used to analyze rock movement for the design of a safety related turbine building wall (the 12 line wall), it was believed that this condition may have adversely af fected the safety of operations of the plant if it had remained uncorrected.

Analysis of Safety Implications As indicated below, the MARC-CDC computer program as' modified by Dames and Moore has been certified. Therefore, this condition would not have adversely affected the safety of operations of the plant if it were to have remained uncorrected.

I Corrective Action A job-specific certification of the MARC-CDC computer program as modified by Dames and Moore has been performed. All test cases run showed satisfactory results and the certification of the computer program is completed.

(

1 l

l I

l l

l l

l L_-_________-______-_