Advises That Design Max Temp of Standby Nuclear Svc Water Pond Raised from 95 F to 100 F,In Response to Sser 1,Open Item 2.Info Will Be Incorporated in Fsar,Rev 8
ML20078K607
Person / Time
Site: Catawba  
Issue date: 10/13/1983
From: Tucker H
DUKE POWER CO.
To: Adensam E, Harold Denton
Office of Nuclear Reactor Regulation
References
NUDOCS 8310190165
Download: ML20078K607 (3)


Text

f DUKE POWER GOMPANY -

P.O. box 33180 CHARLOTTE, N.C. 28242 '

"^':.";.5.'."""

    1. A"1A October 13, 1983

= = - =

Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Attention: Ms. E. G. Adensam, Chief Licensing Branch No. 4 Re: Catawba Nuclear Station Docket Nos. 50-413 and 50-414

Dear Mr. Denton:

Section 2.4.4.2 of Supplement 1 to the Catawba Safety Evaluation Report discusses Open Item 2, Pe-fonnance of the SNSW Pond,using NUREG-0693. As noted therein the Staff's prediction of the maximum Standby Nuclear Service Water (SNSW) pond temperature (98.4 F) exceeded the temperature (96 F) given in FSAR Section 9.2.5.3.1.

In order to resolve this issue Duke had previously agreed to requalify any equipment that would be affected by the higher SNSW pond temperature calculated by the Staff.

The design maximum temperature of the SNSW pond and associated pipe in the Nuclear Service Water System has been raised from 95 F to 100 F.

This change is reflected in the attached FSAR page which will be included in Revision 8.

Very truly yours,

\\c M

Hal B. Tucker ROS/php Attachment cc: Mr. James P. O'Reilly, Regional Administrator U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30303 NRC Resident Inspector Catawba Nuclear Station Palmetto Alliance 21351 Devine Street i

e (

Columbia, South Carolina 29205

^'B3101903$5 g33og3

{DRADOCK 05000413 PDR

C Mr. Harold-R. Denton, Director October 13, 1983 Page 2 cc: Mr. -Robert Guild, Esq.

Attorney-at-Law P. O. Box 12097 Charleston, South Carolina 29412 Mr. Jesse L. Riley_

Carolina Environmental Study Group 854 Henley Place Charlotte, North C..olina 28207 i

J l

i l

l i

i

CNS a.

Remove residual and sensible heat from the Reactor Coolant System via the Residual Heat Removal System, during plant shutdown and startup.

4 b.

Cool the letdown flow to the Chemical and Volume Control System during power operation.

c.

Cool the spent fuel pool water.

d.

Provide cooling to dissipate waste heat from various other primary plant components.

e.

Provide cooling to engineered safeguards loads after an accident.

The Component Cooling System serves as an intermediate system and a second boundary between the Reactor Coolant System and the Nuclear Service Water System.

This double barrier arrangement reduces the probability of leakage of radioactivity to the environment.

The Component Cooling System design is based on maximum heat sink temperatures (supplied by the Nuclear Service Water System) of 90*F (normal) and 100*F (following a LOCA).

During normal operating conditions, the maximum temperature of the component cooling water supplied to the components and reactor coolant pumps is 100*F.

During a fast unit shutdown in 14 hours1.62037e-4 days <br />0.00389 hours <br />2.314815e-5 weeks <br />5.327e-6 months <br /> the temperature of the component cooling water will approach 120*F.

This will occur during the initia-tion of residual heat removal at the fourth hour of the shutdown.

The tempera-ture of the component cooling water will also exceed 100*F following a LOCA.

Active system components considered vital to the cooling function are redundant.

Such redundancy of components prohibits a single failure from preventing safe shutdown in any essential system served by the Component Cooling System. Any single passive failure in this system does not prevent the system from per-forming its design function due to double isolation valves on every crossover between safety trains.

The design provides means for the detection of radioactivity entering the system from the Reactor Coolant System and its associated auxiliary systems, and includes provision for isolation of system components.

9.2.2.2

System Description

l The Component Cooling System normally functions as two independent subsystems.

One subsystem for Unit 1 and one subsystem for Unit 2.

Unit 1 flow diagrams are shown in Figures 9.2.2-1 through 9.2.2-10.

The two units are identical except cooling water supplied to shared equipment is contained in the Unit I subsystem.

Crossovers are provided between the two subsystems so that cooling water can be supplied to shared equipment from either unit.

Such sharing of l

components does not degrade the performance or reliability of the essential portion of the Component Cooling System, as crossovers and non-essential shared components are isolated on Engineered Safeguards Actuation Signals.

The Component Cooling System consists of eight (four per unit) component 9.2-12 Rev. 8 4