DESIGN FEATURES 5.3 REACTOR CORE FUEL ASSEMBLIES 5.3.1 The core shall contain 157 fuel assemblies. Each fuel assembly shall consist of 264 Zircaloy-4 or ZIRLO( ) clad fuel rods with an initial composition of uranium dioxide with a maximum nominal enrichment of 5.0 weight percent U-235 as fuel material. Limited substitutions of Zircaloy-4, ZIRLO( )

and/or stainless steel filler rods for fuel rods, ifjustified by a cycle specific reload analysis using an NRC-approved methodology, may be used. Fuel assembly configurations shall be limited to those designs that have been analyzed with applicable NRC staff-approved codes and methods, and shown by tests or cycle-specific reload analyses to comply with all fuel safety design bases. Reload fuel shall contain sufficient integral fuel burnable absorbers such that the requirements of Specifications 5.6.1 la.2 and 5.6.1.2.b are met.

A limited number oflead test assemblies that have not completed representative testing may be placed in non-limiting core locations.

CONTROL ROD ASSEMBLIES 5.3.2 The reactor core shall contain 48 fulllength control rod assemblies.

The fulllength control rod assemblies shall contain a nominal 142 inches of absorber material. The nominal values of absorber material shall be 80 mercent silver,15 percent indium and 5 percent cadmium. All control rods shall E ye clad with stainless steel tubing.

5.4 RE ACTOR COOLANT SYSTEM DESIGN PRESSURE AND TEMPERATURE 5.4.1 The reactor coolant system is designed and shall be maintained:

a.

In accordance with the code requirements specified in Section5.2 of the FSAR, with allowance for normal degradation pursuant to the applicable Surveillance Requirements, b.

For a pressure of 2485 psig, and c.

For a temperature of 650 F, except for the pressurizer which is 680 F.

I VOLUME 5.4.2 The total water and steam volume of the reactor coolant system is 9914 100 cubic feet at an indicated Tavg of 587.4*F.

l 5.5 METEOROLOGICAL TOWER LOCATION 5.5.1 The meteorological tower shall be located as shown on Figure 5.1-1.

SUMMER - UNIT 1 5-6 Amendment No. 27, 55, 02, 9410260159 941020 74,105,11 C, PDR ADOCK 05000395 l

P PDR