9100120213 910006 DR ADOCK 0500 5

TABLE 4.3-1 (Continued)

REACTOR TRIP SYSTEM INSTRUMENTATION SURVEILLANCE REQUIREMENTS TRIP ANALOG ACTUATING MODES FOR c

CHANNEL DEVICE WHICH CHANNEL CHANNEL OPERATIONAL OPERATIONAL ACTUATION SURVEILLANCE FUNCTIONAL UNIT CHECK _ _ALIBRATION TEST TEST LOGIC TEST IS REQUIRED y

r 13.

Steam Generator Water level--

S R

Q N.A.

N.A.

1, 2 Low-Low i

la.

Steam Generator Water Level -

S R

Q N.A.

N.A.

1, 2 Low Coincident with Steam /

Feedwater Flow Mismatch 15.

Undervoltage - Reactor Coolant N.A.

R N.A.

Q N.A.

1 Pumps N

[

16. Underfrequency - Reactor N.A.

R N.A.

Q N.A.

I 4

Coolant Pumps na 17.

Turbine Trip A.

Low Fluid Oil Pressure N.A.

R N.A.

S/U(1, 10)

N.A.

I B.

Turbine Stop Valve N.A.

R N.A.

S/U(1, 10)

N.A.

1 Closure 18.

Safety Injeccion Input from N.A.

N.A.

N.A.

R N.A 1, 2 ESF

[

19.

Reactor Trip System Interlocks E

A.

Intermediate Range N.A.

R(4)

R N.A.

N.A.

2##

5 Neutron Flux, P-6 o

i 8.

Low Power Reactor k

Trips Block, P-7 N.A.

R(4)

R N.A.

N.A.

1 c"

C.

Power Ranoe Neutron S

Flux, P-8~

N.A.

R(4)

R N.A.

N.A.

I

D TABLE 4.3-1 (Continued) m C

h REACTOR TRIP SYSTEM INSTRUMENTATION SURVEILLANCE REQUIREMENTS x

TRIP ANALOG ACTUATING MODES FOR E

CHANNEL DEVICE MiiCH O

CHANNEL CHANNEL OPERATIONAL OPERATIONAL ACTUATION SURVEILLANCE FUNCTIONAL UNIT CHECK CALI5 RATION TEST TEST LOGIC TEST IS REQUIRED y

D.

Low Setpoint Power Range Neutron Flux, P-10 N.A.

R(4)

R N.A.

N.A.

1, 2 E.

Turbine Impulse Chamber Pressure, P-13 N.A.

R R

N.A.

N.A.

1 F.

Lw Power Range Neutron Flux, P-9 N.A.

R(4)

R N.A.

N.A.

I 20.

Reactor Trip Breaker N.A.

N.A.

N.A.

M (7, 12)

N.A.

1, 2, 3*,

4*, 5*

w2 21.

Automatic Trip logic N.A.

N.A.

N.A.

N.A.

M (7) 1, 2, 3*. 4*, 5*

m 22.

Reactor Trip Bypass H.A.

N.A.

N.A.

M(13), R(14)

N.A.

1. 2, 3*, 4*, 5*

l Breaker E

Et an

TABLE 3.3-3 (Continued) 5 g

ENGINEERED SAFETY FEATURE ACTUATION SYSTEll INSTRUMENTATION 9

g MINIMUM TOTAL NO.

CHANNELS CHANNELS APPLICABLE c-FUNCTIONAL UNIT OF CHANNELS TO TRIP OPERABLE MODES ACTION 4.

STEAM LINE ISOLATION a.

Manual i.

One Switch /line 1/ steam line 1/ steam line 1/ operating 1, 2, 3 23 steam line ii.

One Switch /all lines 1

1 1

1,2,3 23 b.

Automatic Actuation 2

2 1,2,3 21 Logic and Actuation Relays c.

Reactor Building Pressure--

3 2

1,2,3 24*

High-2 l

m O

d.

Steam Flow in Two 2/ steam line 1/ steam line 1/ steam line 1, 2, 3 24*

l Steam Lines--High any 2 steam lines COINCIDENT WITH I T,yg any 1T any 1,2,3 24*

l T

--t w-L w 1Tavg/l p

avg avg 2 loops 2 loops Y

51 8

n

. TABLE 3.3-3 (Continued) v,

[

ENGINEERED SAFETY-FEATURE ACTUATION SYSTEM INSTRUMENTATION

' ~ -

.. MINIMUM ~

'g~

TOTAL NO.

CHANNELS CHANNELS APPLICABLE

-Q FUNCTIONAL UNIT OF CHANNELS TO TRIP OPERABLE

' MODES ACTION

~

6.

EMERGENCY.FEEDWATER a.

Manual Initiation 1 per pump 1 per pump 1 per pump.

1, 2,. 3 22 b.

Automatic' Actuation Logic ~and Actuation Relays-2-

1 2

1,2,3 21 c.

Sta. Gen.' Water Level-tow-Low

i. ' Start Motor-Driven Pumps 3/stm. gen.

2/stm. gen.

2/stm. gen.

1,2,3 24*

'c.,

any stm gen l

y ii.

Start Turbine-3 Driven Pemp 3/stm. gen.

2/sta. gen.

2/sta. gen 1, 2, 3 24*

l any 2 stm. gen.

d.

Undervoltage-both ESF Busses l

Start Turbine-Driven Pump 2-1/ bus

'2 2

1,2,3 19 3

e.

S.I.

Start Motor-g Driven'Pumos See'I above (al1 S.I. initiating functions and requirements)

. E f.

Undervoltage-one ESF bus E

Start Motor-Driven 4

E Pumps 1/ bus 1

2 1, 2 22 g

g.

Trip of Main Feedwater Pumps N

Start Motor-

-Driven-Pump.

3-1/ pump 3-1/ pump 3-1/ pump 1, 2 19 E$

h.

Suction Transfer on

' Low Pressure 4

2 3

1,2,3 16 4

i.

r l

' TABLE 3.3-3'(Continued).,

ENGINEERED SAFE 1Y FEATURE ACTUATION SYSTEM INSTRUMENTATION e

i c_

MINIMUM 55 TOTAL-NO.

CHANNEL $

CHANNELS APPLICABLE

((

FUNCTIONAL UNIT-0F. CHANNELS T0 TRIP _

OPERABLE

_ MODES-ACTION 7.

LOSS OF POWER-4

.a.

7.2 kv Emergency Bus Undervoltage.

(Loss of. Voltage) 2-1/ bus

'l 2

1,2,3,4 18 i

i b.

7.2 kv Emergency' Bus Undervoltage.

18.

(Degraded. Voltage) 2-1/ bus 1

2 1, 2,'3, 4 8.

AUTOMATIC SWITCHOVER TO CONTAINMENT SUMP

. ss a.

RWST level' low-low 4

2 3

1,2,3-16' E$

b.

~ Automatic Actuation

-Logic and Actuation 1

Relays 2

1 2

1,2,3 21 l_

9.

ENGINEERED SAFETY FEATURE 4

c ACTUATION SYSTEM INTERLOCKS i.

a.

Pressurizer Pressure, 3

2 2

1,2,3 20 P-Il b.

Low-Low Tavg, P-12 3

2 2

1,2,3 20-

)

a c.

Reactor Trip, P-4 2

2 2

1,2,3 22 5

. ~

m J TABLE 4.3-2 (Continued)

ENGINEERED SAFETY FEATURE ACTUATION SYSTEM INSTRUMENTATION SURVEILLANCE REQUIREMENTS x

i g

TRIP q

ANALOG ACTUATING MODES FOR CHANNEL DEVICE MASTER SLAVE WHICH g

CHANNEL CHANNEL OPERATIONAL OPERATIONAL ACTUATION RELAY RELAY SURVEILLANCE FUNCTIONAL UNIT CHECK CALIBRATION TEST TEST LOGIC TEST TEST TEST 15 REQUIRED EMERGENCY FEEDWATER (Continued) d.

Undervoltage - Both ESF-N.A.

R N.A.

R N.A.

N.A.

N.A.

1, 2, 3 Busses e.

Safety Injection See 1 above for all Safety Injection Surveillance Requirements f.

Undervoltage - One N.A.

R N.A R

N.A N.A N.A.

1, 2, 3 l

ESF Bus g.

Trip of Main Feedwater N.A.

N.A.

N.A.

R N.A.

N.A.

N.A.

1, 2 l

Pumps m.

E h.

Suction transfer on 5

R Q

N.A.

N. A.

N.A.

N.A.

1,2,3 low pressure 7.

LOSS OF POWER a.

7.2 kV Emergency Bus.

N.A.

R N.A.

R N.A.

N.A.

N.A.

1, 2, 3, 4 Ur.demoltage (Loss of Voltage) b.

7.2 kV Emergency Bus N.A.

R N.A.

R N.A.

N.A.

N.A.

1, 2, 3, 4 Undervoltage (Degraded g

Voltage) o E 8.

AUTOMATIC SWITCH 0VER TO CONTAINMENT SUMP y

a.

RWST level low-low 5

R Q

N.A.

N.A.

N.A.

N.A.

1, 2, 3 9

b.

Automatic Actuation N.A.

N.A.

N.A.

N.A.

M(1)

M(1)

Q 1,2,3 S

Logic and Actuation Relays