t TENNESSEE VALLEY AUTHORITY CHATTANOOGA. TENNESSEE 374ol 400 Chestnut Street Tower II

-4C

-w July 19, 1983 Q

r-go ry:

BLRD-50-438/81-30

.,in BLRD-50-439/81-33 35 Yd c:a oo U.S. Nuclear Regulatory Commission f'U O

Region II Attn: Mr. James P. O'Reilly, Regional Administrator 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30303

Dear Mr. O'Reilly:

BELLEFONTE NUCLEAR PLANT UNITS 1 AND 2 - GENERIC IMPLICATIONS OF FAILURE TO IMPLEMENT DESIGN CRITERIA IN DESIGN DRAWINGS - BLRD-50-438/81-30, BLRD-50-439/81 SIITH INTERIM REPORT The subject deficiency was initially reported to NRC-0IE Inspector R. V. Celenjak on April 1, 1981, in accordance with 10 CFR 50.55(e) as NCR BLN QAB 8101. This was followed by our interim reports dated May 1 and October 22, 1981, January 22, and July 7, 1982, and January 14, 1983 TVA is still evaluating the subject deficiencies. TVA has completed the review of functional control logio diagrams. As a result of this review, NCRs BLN BLP 8101, 06,10,18, and 19, BLN BLP 8222 and 35, and BLN BLP -

8312, and 21 have been initiated. However, additional investigations of other deswings must be performed before the subject nonconformance (BLN QAB 8101) can be resolved. We expect to submit our next report by October 21, 1983 If you have any questions, please get in touch with R. H. Shell at FTS 858-2688.

Very truly yours, TENNESSEE VALLEY AUTHORITY L. M. Mills, kanager Nuclear Licensing oc: Mr. Rich rd C. DeYoang, Director Office of Inspection and Enforcement 1

U.S. Nuclear Regulatory Commission i

Washington, D.c.

20555 Records Center Institute of Nuclear Power Operations 1100 Circle 75 Parkway, Suite 1500 fo?T Atlanta, Georgia 30339 Tyy1CN 8307260503 830719 DR ADOCK 05000 3-TVA SOTH ANNIVERSARY g

\\D An Equal Opportunity Employer