F s$,i -
G%Wid:Shb(h LILEY AUTHORITY ARMMArrAsOOGA. TENNESSEE 374ot
"~
^
400 Chestn t Street Tower II B3 M N July 14,-1983 BLRD-50-438/81-64 BLRD-50-439/81-62 U.S. Nuclear Regulatory Commission Region II Attn:
Mr. James P. O'Reilly, Regional Administrator 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30303
Dear Mr. O'Reilly:
BELLEFONTE NUCLEAR PLANT UNITS 1 AND 2 - BOLTS AND NUTS FAIL TO MEET ASTM SPECIFICATIONS - BLRD-50-433/81-64, BLRD-50-439/81 EIGHTH INTERIM REPORT f
The cabject deficiency uns initially reported to NP.C-0IE Inspector R. V. Crlenjak on Septezber 24, ;961 in accordsnce with 10 CFK 50.5S(e) as NCR's 1597 and 1598. This was followed by our interk reports dated October 22 and DecemNP 2,1981; February 19,. Tune 29, and September 27, 1932; cad Jc.nuey 7, and April 25, 1983 Enclosed is our eignth interim report. We expect to submit cur ne::t report by November 18, 1983 We consider 10 CFR Pnet 21 epplicab36 to this deficiency.
If y6u have any qu3stions concerning ti;is matter, please get in touch with R. H. Shall at FTS 858-2688.
Very truly yours, TENNESSEE VALLEY AUTHORITY
.hA$
L. M. Millst Manager Nuclear Licensings, Enclosure cc:
Mr. Richard C. DeYoung, Director (Enclosure)
Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, D.C.
20555 Records Center (Enclosure)
Institute of Nuclear Power Operations 1100 Circle 75 Parkway, Suite 1500 Atlanta, Georgia 30339
'gCIALCOPY,
4 '7 8307220169 830714
/
PDR ADOCK 05000438 An Equal Opportunity Employer JJ
'l'
m t'
l' Y
a
. -- /
ENCLOSURE BELLEFONTE NUCLEAR PLANT UNITS 1 AND 2
'~
~
BOLTS AND NUTS FAIL TO MEET ASTM SPECIFICATIONS NCR'Si tS97 AND 1598 BLRD-50-438/81-64, BLRD-50-439/81-62 _,
EIGHTH INTERIM REPORT Description of Deficiency 10,000, 3/4" stainless steel nuts (furnished by Chattanooga Bolt and Screw, Chattanooga, Tennessee) and 10,600, 3/4" x 3-1/2" stainless steel bolts (furnished by Challenge Enterprises, Chattanooga, Tennessee),were received not marked in accordance with ASTM specifications. Subsequent testing of e
the subject material by Singleton Materials Engineering Laboratory revealed the material failed to meet ASTM specifications. The associated r
documentation received with the material erroneously indicated that the nuts and bolts do meet ASTM specifications. Approximately 450 of these bolts and 1300 nuts have been issusd to the field for installation.
Nonconformanco report (NCR) 1597 pertains,to the bolts and NCR 1598
~ ~~
portaina to the nuts.
i Interim Pro 3ress TVA is currently reviewing the results of the Eingleten Laboratory analyeis of tha bclting material. The test results will be discussed upon coupletion cf the subject review.
L I
h b
I '
.aint b
4 n-e
.., _ _