E NUCI98r GPU Nuclear Corporation One Upper Pond Road Parsippany, New Jersey 07054 201-316-7000 TE LEX 136-482 Writer's Direct Dial Number.

November 3, 1994 5000-94-0044 C321-94-2290 U. S. Nuclear Regulatory Commission Att: Document Control Desk Washington, DC 20555 Gentlemen:

Subject:

Oyster Creek Nuclear Generating Station (OCNuS)

Docket No. 50-219 Facility Operating License No. DPR-16 Core Spray Sparger - 15R Outage' Inspections The Oyster Creek Nuclear Generating Station Technical Specifications, Append;x A, para. 6.9.3.e, and the Facility Operating License para. 2.C.(5), require that a special report presenting the.results of the inservice inspection of the core spray spargers during each refueling outage be provided for review and that authorization be obtained from the Commission's staff before the plant is restarted from each refueling outage.

Topacal Report No. TR-098, which is enclosed for your review, is the core spray sparger inspection report for the Cycle 15 refueling outage.

It describes the nondestructive examinations that were performed on the core spray spargers and the associated in-vessel annulus piping. The sparger assemblies and in-vessel annulus piping were inspected utilizing a remote visual (camera) examination supplemented with an optional air test.

The report documents that no new relevant indications or anomalies were found and no change in pre-existing conditions were noted since the prior Cycle 14 refueling outage inspection.

If you have any questions or comments on this submittal, please contact Mr. Michael Laggart, Manager, Corporate Nuclear Licensing at (201) 316-7968.

Vergtrul yjurs,p f

M (.,

R. W.

.e ten Vice President and Director Technical Functions RWK/RTZ/ pip c: Administrator, Region 1 Oyster Creek NRC Project Manager

,[(p li Senior Resident Inspector p

9411090214 941103

\\

PDR ADOCK 05000219

\\

090L32 GPU Nuclear Corporation is a subsidiary of General Pubhc Utilities Corporation

-