Interim Deficiency Rept,Item M-50 Re Masking of Radiography by Inadequate Surface Preparation.Requests Relaxation of 821112 Order to Show Cause & Order Immediately Suspending Const,To Allow Blend Grinding for Reradiography
ML20076J721
Person / Time
Site: Zimmer
Issue date: 08/29/1983
From: Williams J
CINCINNATI GAS & ELECTRIC CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
10CFR-050.55E, 10CFR-50.55E, CLI-82-33, LQZ-83-0118, LQZ-83-118, NUDOCS 8309070298
Download: ML20076J721 (10)


Text

'-

ar Nw,

TIIE CINCINNATI GAS & ELECTRIC COMPANY CINCINN ATI. OHIO 45201 August 29, 1983 LOZ-83-Oll8 J. WILLIAM S, JR stN80R VICE PRESIDENT NUCLEA R OPERAftCNS Docket No. 50-358 U.S. Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, Illinois 60137 Attention:

Mr. J.G.

Keppler Regional Administrator

Dear Mr. Keppler:

RE:

WM. H. ZIMMER NUCLEAR POWER ETATION - UNIT 1 10CFR50.55 (e), ITEM M-50, MASKING OF RADIOGRAPHY BY INADEQUATE SURFACE PREPARATION W.O. 57300, JOB E-5590, FILE NO. 956C, M-50 This letter requests the relaxation of the NRC November 12, 1982 " Order to show Cause and Order Immediately Suspending Construction", (CLI-8 2-3 3 ), pursuant to Section IV.B (3), to allow the blend grinding of those welds with inadequate surface preparation to be performed at this time so that reradiography may be conducted.

This letter also constitutes an interim report concerning the subject condition reported to the Commission as a reportable deficiency under the requirements of 10CFR50.55(e) and provides the status of the actions being taken to resolve the deficiency.

As indicated in our previous interim report, LOZ-83-0020, dated April 29, 1983, the review of all field weld piping radiographs has been completed.

Of the 3,768 weld radiographs reviewed, 291 welds in nineteen piping systems have been identified as having surface conditions which could potentially mask rejectable discontinuities in the weld.

The affected piping systems, and number of welds within each system, include:

Oh[o!$ojjjg o

PDR E,*)

-L2

,bh

E Mr. J.G.

Keppler Regional Administrator August 29, 1983 LOZ-83-Oll8 Page 2 SYSTEM NO. OF WELDS

  • 1.

Cycled Condensate Storage (CY) 1 2.

Diesel Generator (DG) 1 3.

Fuel Pool Cooling and Cleanup (FC) 8 4.

Feedwater (FW) 35 5.

Feedwater Drains-Turbine Cycle (HD) 1 6.

Primary Containment Combustion and Gas Control (HG) 4 7.

High Pressure Core Spray (HP) 7 8.

Low Pressure Core Spray (LP) 5 9.

Main Steam (;MS) 51

10. Nuclear Boiler (NB) 1

(' G) 3

11. Off Gas O
12. Residual Heat Removal (RH) 49
13. Reactor Building & Control Floor Drains to Radwaste (RF) 1
14. Reactor Core Isolation Cooling (:RI) 8
15. Reactor Water Cleanup (RT) 3
16. Primary Containment Ventilation (VP) 2
17. Reactor Building Closed Cooling Water (WR) 56
18. Service Water (WS) 54
19. Solid Radwaste Reprocessing & Disposal (WX) 1 The attached listing identifies each of the above welds by weli number, PSK drawing number, piping system line number, and applicable Nonconformance Report (NR) number.

Construction Work Authorization Request (CWAR) #192. Revision 4

1, has been prepared by CG&E to blend grind and reradiograph these 291 welds per the Nonconformance Report dispositions.

The overall program to identify and control the blend grinding and reradiography will be accomplished in accordance with approved procedures.

Those welds which fail the reradiographic examination will be identified on Nonconformance Reports for disposition and corrective action.

The procedures, including the controls to be applied to assure compliance, are available for review by your site representatives.

Mr. J.G. Keppler Regional Administrator August 29, 1983 LOZ-83-0118 Page 3 Completion of these activities will permit CG&E to determine the status of the affected welds and identify those requiring rework.

Accordingly, it is requested that CG&B be permitted to proceed as soon as possible with this blend grinding and reradiography program.

We trust this will be found acceptable as an interim report under 10CFR50.55 (e) and would appreciate your approval of the above request for relaxation of the NRC November 12, 1982 " Order to Show Cause and Order Immediately Suspending Construction" (CLI-8 2-33 ).

Very truly yours, THE CINCINNATI GAS & ELECTRIC COMPANY By

. W LLIAMS,,

t SENIOR VICE PRESIDENT RNT/sfr ATTACHMENT cc:

NRC Office of Inspection & Enforcement Washington, D.C.

20555 NRC Senior Resident Inspector ATTN:

T.P. Gwynn NRC Zimmer Project Inspector, Region III ATTN:

E. R. Schweibinz

OZ-8 0

8 l.

August 29, 1983 Page i of 7 1.

The following welds, identified during the radiographic film review conducted per the corrective actions for 10CFR50.55(e) items M-22 and M-50, have surface indications which could mask rejectable discontinuities.

These welds require blend grinding and reradiography per Construction Work Authorization Request (CWAR) #191, Revision 1.

Weld No.

PSK No.

Line No.

CG&E NR No.

CY-101 1CY-7 1CY03DA16-72 Q-QAD-83-ll20-E DG-K58 1DG-13 1DG14AB8 Q-QAD-83-0390-E FC-6 lFC-14 1FC01B12 Q-QAD-83-0390-E FC-23 1FC-16 1FC02AB8 Q-QAD-83-0390-E FC-29A 1FC-18 1FC02AB8 Q-QAD-83-1998-E FC-2 1FC-14 1FC01CB10 0-QAD-82-4304-E FC-40 1FC-22 1FC09AA8 Q-QAD-83-0390-E FC-41 1FC-22 1FC09B8 Q-QAD-83-ll20-E FC-64A 1FC-24 1FC09AB8-42 CAR 83-25 FC-121 1FC-36 1FC20B10

  • Q-QAD-82-4775-E
  • (Q-QAD-8 3-19 9 8-E)

FW-1 1FW-26 1FW0lDB23.83

  • Q-QAD-83-4763-E
  • (Q-QAD-8 3-2 0 0 8-N }

FW-2 1FW-26 1FW0lDB23 Q-QAD-83-0390-E FS-3 1FW-26 1FW0lCB16.95

  • Q-QAD-82-4772-E
  • (Q-QAD-8 3-20 0 8-N)

FW-5 1FW-26 1FW01DA23.83 Q-QAD-83-2008-N FW-6 1FW-26 1FW0lDA23.83 Q-QAD-83-2008-N FW-7 1FW-26 1FW01DA23.83 Q-QAD-83-2008-N FW-10 1FW-26 1FW01DA23.83

  • Q-QAD-83-4771-E
  • (Q-QAD-8 3-2 0 08-N)

FW-14 1FW-27 1FUOlAB19.3 Q-QAD-83-2008-N FW-15 1FW-27 1FW0 LAB 19 Q-QAD-83-ll20-E FW-16 1FW-27 1FW01AB19 Q-QAD-83-ll20-E FW-22 lFW-27 1FW01AA19.30 Q-QAD-83-ll20-E FW-23 1FW-27 1FW01AA19.30 Q-QAD-83-ll20-E FW-24 1FW-27 1FW01AA19.30 Q-QAD-83-1120-E l

FW-28 1FW-26 1FW20A13 Q-QAD-83-ll20-E FW-36 1FW-28 1FW20A13 Q-QAD-83-1120-E FW-37 1FW-28 1FW21AB13 Q-QAD-83-ll20-E FW-43 1FN-31 1FWO3A19.30 Q-QAD-83-il20-E FW-44 lFW-30 1FWO2C23 Q-QAD-83-1120-E FW-48 lFW-29 1FWO2A16 Q-QAD-83-ll20-E FW-65 1FW-29 1FWO2DB16 Q-QAD-83-1120-E FW-79 1FW-31 1FWO2C23 Q-QAD-83-ll20-E FN-80 1FW-31 1FWO2AA23.83 Q-QAD-83-ll20-E FW-81 1FW-31 1FWO2AA23.83 Q-QAD-83-ll20-E FW-83 lFW-31 1FWO2AB23 Q-QAD-83-ll20-E FW-84 1FW-31 1FWO2AB23 Q-QAD-83-ll20-E FW-85 1FW-31 1FW02BB16 Q-QAD-83-ll20-E FW-86 1FW-32 1FWO4ABll Q-QAD-83-0390-E FW-103 1FW-33 1FWO4AAll Q-QAD-83-1120-E FW-109 1FW-34 1FW05AB13.94 Q-QAD-83-1120-E

  • Weld identified on more than one NR.

Attachmant LOZ-83-Oll8 29 1983 Augurt Page 2 of 'l Weld No.

PSK No.

Line No.

CG&E NR No.

FW-113 lFW-34 1FWO5A13 Q-QAD-83-ll20-E FW-ll6A 1FW-34 1FW05A13.94 Q-QAD-83-ll20-E FW-ll6B 1FW-34 1FW05A13.94 Q-QAD-83-ll20-E FW-119 1FW-26 1FWO3A19.30 Q-QAD-83-ll20-E FW-K54 1FW-27 1FW01AA19.3 Q-QAD-83-2008-N FW-K55 1FW-27 1FW01AB19.3 Q-QAD-83-2008-N HG-K43 lHG-10 lHG03A4 Q-QAD-83-0390-E HG-K71 lHG-13 lHG07A4 Q-QAD-83-0390-E HG-K78 lHG-13 lHG07A4 Q-QAD-83-0390-E HG-K210 1HG-13 lHG07A4 Q-QAD-83-0390-E HD-468A lHD-52 lHD20AB18 Q-QAD-83-1120-E HP-5 lHP-1 lHPlE22F002 Q-QAO-83-ll20-E HP-14 lHP-2 lHPlE22F024 Q-QAD-83-1120-E HP-18 lHP-5 lHP03A14 Q-QAD-83-0390-E HP-22 lHP-2 lHP03A14-ll Q-QAD-83-0390-E HP-K24 lHP-7 lHP21A4 Q-QAD-83-0390-E HP-K36 lHP-4 lHPl7B3 Q-QAD-83-ll20-E HP-37 lHP-2 lHP03A14 Q-QAD-83-0390-E LP-2 lLP-3 lLP02B10-1 Q-QAD-83-1120-E LP-3 lLP-3 lLP02B10 Q-QAD-83-0390-E LP-Kll lLP-19 lLP14B3 Q-QAD-83-0390-E LP-12 lLP-ll lLP02Al2 Q-QAD-83-1120-E LP-22 lLP-12 lLP02A12-16 Q-QAD-83-0390-E MS-7 1MS-5 1MS01BB24 Q-QAD-82-4260-E MS-ll 1MS-1 1MS01BA24 Q-QAD-82-0390-E MS-16 1MS-4 1MS0lBA24 Q-QAD-82-0390-E MS-25 1MS-3 1MS01BD24 Q-QAD-83-0390-E MS-34 1MS-2 1MS01BC24 Q-QAD-83-0390-E MS-54 lMS-15 lMS26AB10 Q-CAD-83-0390-E MS-60 1MS-15 1MS26AB10 Q-QAD-83-0390-E MS-61 1MS-15 1MS26AB10 Q-QAD-83-0390-E MS-68 1MS-15 1MS26AB10 Q-QAD-83-0390-E MS-70 1MS-12 1MS26AA10 Q-QAD-83-0390-E MS-71 1MS-12 1MS25AA10 Q-QAD-83-0390-E MS-73A 1MS-12 1MS26AA10 Q-QAD-83-0390-E MS-77 1MS-12 1MS26AA10 Q-QAD-82-4295-E MS-78 1MS-12 1MS26AA10 Q-QAD-82-4296-E MS-99 1MS-10 1MS32AA8 Q-QAD-82-4297-E MS-122 1MS-42 1MS10AA10-87 Q-QAD-83-0390-E MS-123 1MS-42 1MS10AA10 Q-QAD-83-0390-E MS-124 1MS-42 1MS10AA10 Q-QAD-83-0390-E MS-128 1MS-40 1MS08AB10 Q-QAD-83-0390-E MS-131 1MS-34 1MS08AA10 Q-QAD-83-0390-E MS-132 1MS-34 1MS08AA10 Q-QAD-83-0390-E MS-133 1MS-34 1MS08AA10 Q-QAD-83-0390-E MS-136 1MS-39 lMS07AE10 Q-QAD-83-0390-E MS-137 1MS-39 1MS07AB10 Q-QAD-83-0390-E MS-139 1MS-41 1MS09AA10 Q-QAD-83-0390-E MS-139A 1MS-41 1MS09AA10 Q-QAD-83-0390-E MS-140 1MS-41 1MS09AA10 Q-QAD-83-1120-E MS-142 1MS-29 1MS09AA10 0-QAD-83-0390-E

Attachm:nt LOZ-83-0118 Auguxt 29, 1983 Page 3 of 7 Weld No.

PSK No.

Line No.

CG&E NR No.

RH-2,'

1RH-42 1RH04AA14 Q-QAD-83-0390-E RH-239 1RH-42 1RH04AA14 Q-QAD-83-0390-E RH-251 1RH-60 1RH04AB14 Q-QAD-83-0390-E RH-252 1RH-60 1RH04AB14 Q-QAD-83-0390-E RH-25 4 1RH-60 1RH04AB14-148 Q-QAD-83-0390-E RH-257 1RH-61 1RH04AB14 Q-QAD-83-0390-E RH-258 1RH-14 1RH04ABl4 Q-QAD-83-0390-E RH-258A 1RH-61 1RH04AB14 Q-QAD-83-0390-E RH-259 1RH-61 1RH04AB14 Q-QAD-83-0390-E RH-269 1RH-14 1RH09B10-158 Q-QAD-83-0390-E RH-276 1RH-46 1RH09A14 Q-QAD-83-0390-E RH-277 1RH-46 1RH09A14 Q-QAD-83-1120-E RH-278A 1RH-46 1RH09A14 Q-QAD-83-0390-E RH-279 1RH-46 1RH09A14 Q-QAD-83-0390-E RH-284 1RH-45 1RH09A14 Q-QAD-83-0390-E RH-286 1RH-45 1RH09A14 Q-QAD-83-0390-E RH-370 1RH-54 1RH53Al2 Q-QAD-83-0390-E RH-376 1RH-31 1RH15AA10 Q-QAD-83-0390-E RH-385 1RH-55 1RH33A~.2 Q-QAD-83-0390-E RH-386 1RH-55 1RH38Al2 Q-QAD-83-0390-E RH-390 1RH-55 1RH38A12 Q-QAD-83-0390-E RH-391 1RH-34 1RH06AB14 Q-QAD-83-0390-E RH-393B 1RH-56 1RH69B4 Q-QAD-83-0390-E RH-439 1RH-30 1RH06AA14 Q-QAD-83-0390-E RH-K283 1RH-45 1RH17B4 Q-QAD-83-ll20-E RH-K269 1RH-27 1RH50A3 Q-QAD-83-ll20-E RF-K80 1RF-1 1RF20D3 Q-QAD-83-1998-E RI-K14 1RI-5 1RIOlB4 Q-QAD-82-4311-E RI-22 1RI-2 1RI20A6 Q-QAD-83-0390-E RI-22A 1RI-21 1RI20A6-19 Q-QAD-83-0390-E RI-38 1RI-13 1RI19A6 Q-QAD-83-0390-E RI-39 1RI-10 1RIl9A6-13 Q-QAD-83-0390-E RI-43 1RI-3 1RIl8A6 Q-QAD-83-0390-E RI-46 1RI-4 1RIO2A8 Q-QAD-83-ll20-E RI-47 1RI-ll 1RI20C4 Q-QAD-83-0390-E RT-K21 1RT-6 1RT633B001 0-QAD-83-0390-E RT-K22 1RT-6 1RT633B001 0-QAD-83-0390-E RT-57 1RT-6 1RT02B4 Q-QAD-83-0390-E VP-K241 lVP-2 lVP03CB8 Q-QAD-83-0390-E VP-K250 lVP-3 lVP02BA8 Q-QAD-83-0390-E WR-K32 LWR-35 LWR 08A8 Q-QAD-83-0390-E a

l

Attachm:nt E-LOZ-83-Oll8 Auguat 29, 1983 Page 4 of 7 Weld No.

PSK No.

Line No.

CG&E NR No.

MS-143 1MS-43 1MS07AA10 Q-QAD-83-0390-E MS-144 1MS-43 1MS07AA10 Q-QAD-83-0390-E MS-146 1MS-33 1MS08AC10 Q-QAD-83-0390-E MS-147 1MS-33 1MS08AC10 Q-QAD-83-0390-E MS-148 1MS-33 1MS08AC10 Q-QAD-83-ll20-E MS-150 1MS-35 1MS07AD10 Q-QAD-83-0390-E MS-150A 1MS-35 1MS07AD10 Q-QAD-83-0390-E MS-154A 1MS-36 1MS08AD10 Q-QAD-83-0390-E MS-155 1MS-36 1MS08AD10 Q-QAD-82-4300-E MS-157 1MS-45 1MS07AC10 Q-QAD-83-0390-E MS-157A 1MS-45 lMS07AC10 0-QAD-83-0390-E MS-158 1MS-45 1MS07AC10 Q-QAD-83-0390-E MS-161A 1MS-44 1MS10AB10 Q-QAD-83-0390-E MS-162 1MS-44 1MS10AB10 Q-QAD-83-0390-E MS-164 1MS-40 1MS09AB10 Q-QAD-83-0390-E MS-164A 1MS-38 1MS09AB10 Q-QAD-83-0390-E MS-165 1MS-38 1MS09AB10 Q-QAD-83-0390-E MS-168 1MS-37 1MSilA10 Q-QAD-83-0390-E MS-168A 1MS-37 1MSilA10 Q-QAD-83-0390-E MS-198 1MS-20A 1MS07AA10 Q-QAD-83-0390-E MS-375A6 1MS-375 1MS40AA1.5 Q-QAD-83-0390-E MS-K457 1MS-26A 1MS08BAl2 Q-QAD-83-1120-E MS-K483 1MS-43 1MS07AA10 Q-QAD-83-ll20-E NB-34J4 lNB-34 1NB02A2 Q-QAD-83-1120-E OG-12 LOG-3 LOG 04A4 Q-QAD-83-0390-E OG-22 LOG-3 LOG 03AA4 Q-QAD-83-0390-E OG-23 LOG-4 LOG 04A4 Q-QAD-83-0390-E RH-28 1RH-24 1RH01DB16 Q-QAD-83-0390-E RH-29 1RH-24 1RH01DB16 Q-QAD-83-0390-E RH-40 1RH-26 1RH02BA20 Q-QAD-82-4309-E RH-43 1RH-26 1RH01C18 Q-QAD-83-0390-E RH-88 1RH-65 1RH07AAll2 Q-QAD-83-0390-E RH-89 1RH-57 1RH06AA14 Q-QAD-83-0390-E RH-91 1RH-30 1RH06AA14 Q-QAD-83-0390-E RH-K34 1RH-10 1RH10AA4 Q-QAD-83-ll20-E RH-lll 1RH-31 1RH09AA10 Q-QAD-83-0390-E RH-ll4 1RH-31 1RH08AA10 Q-QAD-83-0390-E RH-ll4A 1RH-31 1RH08AA10 Q-QAD-83-0390-E RH-145 1RH-13 1RH07BB10 Q-QAD-83-0390-E RH-146 1RH-13 1RH07BB14 Q-QAD-83-1998-E RH-151 1RH-34 1RH06AB14 Q-QAD-83-0390-E RH-153 1RH-34 1RH06AB14 Q-QAD-83-0390-E RH-157 1RH-34 1RH06AB14 Q-QAD-83-0390-E P

RH-181A 1RH-60 1RH05AB14 Q-QAD-83-0390-E RH-184 1RH-35 1RH12A8 Q-QAD-83-0390-E RH-196B 1RH-36 1RH12A8 Q-QAD-83-0390-E RH-196C 1RH-36 1RH12A8 Q-QAD-83-0390-E RH-197 1RH-35 1RH12A8 Q-QAD-83-0390-E RH-233 1RH-43 1RH04AA14 Q-QAD-83-0390-E RH-234 1RH-43 1RH04AA14 Q-QAD-83-1998-E

i..

a&

AttEchm:nt LOZ-83-0118 August 29, 1983 Page 5 of 7 Weld No.

PSK No.

Line No.

CG&E NR No.

WR-K35 LWR-35 LWR 08A8 Q-QAD-83-0390-E WR-K37 LWR-35 LWR 08A8 Q-QAD-83-0390-E WR-K38 LWR-35 LWR 08k8 Q-QAD-83-0390-E WR-K69 LWR-13 LWR 20C8 Q-QAD-83-0390-E WR-75 LWR-6 LWR 54Cl2 Q-QAD-83-0390-E WR-78 LWR-ll LWR 54Cl2-53 Q-QAD-83-0390-E WR-80 LWR-ll LWR 54EA14 Q-QAD-83-0390-E WR-K80 LWR-14 LWR 20C8 Q-QAD-83-0390-E WR-81 LWR-ll 1WR54FB12 Q-QAD-83-0390-E WR-82 LWR-ll LWR 54EA14 Q-QAD-83-0390-E WR-83 LWR-ll LWR 54FB12 Q-QAD-83-0390-E WR-ll8A LWR-1 LWR 73D6 Q-QAD-83-0390-E WR-195A LWR-28 LWR 02AB12-144 Q-QAD-83-0390-E WR-196 LWR-28 LWR 02AB12 Q-QAD-83-0390-E WR-197 LWR-28 LWR 02AB12 Q-QAD-83-0390-E WR-198 LWR-28 LWR 02AAl2

  • Q-QAD-8 3-03 9 0-E * (Q-QAD WR-199 LWR-28 LWR 02AAl2 Q-QAD-83-0390-E ll20-E)

WR-200 LWR-28 LWR 02B14 Q-QAD-83-0390-E WR-203 LWR-28 LWR 02B14-Q-QAD-83-0390-E WR-207A LWR-28 LWR 02B14-151 Q-QAD-83-0390-E WR-208 LWR-27 LWR 01B14 Q-QAD-83-0390-E WR-210 1WR-27 LWR 01B14 0-OAD-83-0390-E WR-211 LWR-27 LWR 01B14 Q-QAD-83-0390-E WR-215 LWR-27 LWR 01B14 Q-QAD-83-0390-E WR-219 LWR-26 LWR 01AB12 Q-QAD-83-0390-E WR-221 LWR-26 LWR 01AB12 Q-QAD-83-0390-E WR-223 LWR-26 LWR 01AAl2 Q-QAD-82-4314-E WR-225 LWR-26 LWR 01AAl2 Q-QAD-82-0390-E WR-230 LWR-26 LWR 03A14 Q-QAD-83-0390-E WR-235 LWR-27 LWR 04A14 Q-QAD-83-0390-E WR-236 LWR-31 LWR 06A14 Q-QAD-83-0390-E WR-236A LWR-31 LWR 06A14 Q-QAD-83-0390-E WR-238 LWR-31 LWR 06A14 Q-QAD-83-0390-E WR-265 LWR-31 LWR 07A14 Q-QAD-83-0390-E WR-268 LWR-31 LWR 07A14 Q-QAD-83-0390-E WR-271 LWR-33 LWR 02A14 Q-QAD-83-0390-E WR-275A LWR-34 LWR 07A14 Q-QAD-93-0390-E WR-276 LWR-34 LWR 07A14 Q-QAD-83-0390-E WR-277 LWR-34 LWR 07A14 Q-QAD-83-0390-E WR-287 LWR-34 LWR 40B12 0-QAD-83-4315-E WR-295 LWR-33 LWR 07A14 Q-QAD-83-0390-E WR-K317 LWR-35 LWR 08A8 Q-QAD-83-0390-E WR-337 LWR-42 LWR 05A14-249 CAR 83-25 WR-338 LWR-42 LWR 05A14 Q-QAD-83-0390-E WR-339 LWR-42 LWR 05A14 Q-QAD-83-0390-E WR-350 LWR-42 LWR 05D10 Q-QAD-83-0390-E WR-390 INR-44 lWRllD14 Q-QAD-83-0390-E WR-391 LWR-44 lWRllEB12-283 Q-QAD-83-0390-E WR-392 LWR-44 lWRllD14 Q-QAD-83-0390-E WR-392A LWR-44 lWRllDA14 Q-QAD-83-0390-E WR-393 LWR-44 lWRllEAl2 Q-QAD-83-0390-E WR-407B IWR-44 lWRllD14 Q-QAD-83-0390-E WR-K489 IWR-1 LWR 73C6 Q-QAD-83-0390-E

  • Weld identified on more than one NR.

f Attachm nt LOZ-83-0118 August 29, 1983 Page - 6 of 7 Weld No.

PSK No.

Line No.

CG&E NR No.

WR-K616 LWR-17 LWR 76E6 Q-QAD-83-0390-E WR-K816 LWR-34 LWR 44A6 Q-QAD-83-0390-E WS-K5 lWS-42 lWS01AA30 Q-QAD-82-4323-E WS-K6 lWS-42 1WS01AB30 Q-QAD-82-4324-E WS-K7 lWS-43 lWS01AC30 Q-QAD-82-4325-E WS-K8 1WS-43 lWS01AB30 Q-QAD-82-4292-E WS-15A lWS-35 lWS13Bl4 Q-QAD-83-0390-E WS-16 1WS-37 lWS09HB2 Q-QAD-83-0390-E WS-K16 lWS-92 lWS39B18 Q-QAD-83-0390-E WS-20 1WS-36 lWS02J14 Q-QAD-83-0390-E WS-21 1WS-27 lWS12A14 Q-QAD-83-0390-E WS-18 lWS-37 lWS09HA24 Q-QAD-83-ll20-E WS-24 lWS-27 lWS02J14 Q-QAD-83-0390-E WS-30 lWS-27 lWS02H18 Q-QAD-83-0390-E WS-31 lWS-29 lWS02H18 Q-QAD-83-0390-E WS-34 lWS-28 lWS02H18 Q-QAD-83-0390-E WS-43 lWS-34 lWS15D24 Q-QAD-83-0390-E WS-43A lWS-34 lWS15E24 Q-QAD-83-0390-E WS-44 lWS-34 1WS15D24 Q-QAD-83-0390-E WS-45 lWS-31 lWS15E24 Q-QAD-83-0390-E WS-47 lWS-31 lWS15A18 Q-QAD-83-0390-E WS-53A 1WS-31 lWS15A18 Q-QAD-83-0390-E WS-57 IWS-26 lWS16A14 Q-QAD-83-0390-E WS-58 lWS-26 lWS16A14 Q-QAD-83-0390-E WS-60 lWS-32 lWS17A18 Q-QAD-83-0390-E WS-62A lWS-32 lWS17A18 Q-QAD-83-0390-E WS-63C lWS-32 lWS17A18 Q-QAD-83-0390-E WS-63D lWS-32 lWS17A18 Q-QAD-83-0390-E WS-63H lWS-32 1WS17A18 Q-QAD-83-0390-E WS-64B lWS-32 lWS17A18 Q-QAD-83-0390-E WS-68B 1WS-33 lWS13AA14 Q-QAD-83-0390-E WS-314 1WS-26 lWS16A14 Q-QAD-83-0390-E WS-315 lWS-30 lWS18A18 Q-QAD-83-0390-E WS-316 lWS-29 lWS02CA24 Q-QAD-83-0390-E WS-316A 1WS-29 lWS02CA24 Q-QAD-83-0390-E WS-500 lWS-44 lWS40A24 Q-QAD-83-0390-E WS-503 lWS-42 lWS02BA30 Q-QAD-83-0390-E WS-505 lWS-42 lWS02BA30 Q-QAD-83-0390-E WS-506 lWS-40 lWS02BA30 Q-QAD-82-4317-E WS-507 lWS-41 lWS02BB30 Q-QAD-82-4318-E WS-508 lWS-43 lWS02BB30 Q-QAD-82-4319-E WS-508A 1WS-43 lWS02AD24 Q-QAD-83-0390-E WS-508B lWS-43 lWS02BB30 Q-QAD-82-4320-E WS-510 1WS-43 lWS02BB30 Q-QAD-83-0390-E WS-510A 1WS-43 lWS02AC24 Q-QAD-83-0390-E WS-510B lWS-43 lWS02MC16 Q-QAD-83-0390-E WS-Sll lWS-41 lWS02BB30 Q-QAD-83-0390-E WS-512 lWS-41 lWS02CB30 Q-QAD-83-0390-E WS-514A lWS-42 lWS02AB24 Q-QAD-83-0390-E WS-514B lWS-42 lWS02MB16 Q-QAD-83-0390-E WS-515 lWS-41 lWS02KB30 Q-QAD-83-0390-E

\\~

Attachm nt LOZ-83-0118 Augurt 29, 1983 Page 7 of 7 Weld No.

PSK No.

Line No.

CG&E NR No.

WS-538 lWS-40 lWS02CA30 0-QAD-83-0390-E WS-520A lWS-42 lWS02AA24 Q-QAD-83-0390-E WS-520B lWS-42 lWS02MA16 Q-QAD-83-0390-E WS-521 lWS-40 1WS02KA30 Q-QAD-83-0390-E WS-589A lWS-40 1WS02BA30 Q-QAD-83-0390-E WX-K315 IWX-42 IWX95A4 Q-QAD-83-2008-N 2.

The following provides a summary, by system, of the welds requiring blend grinding and reradiography par CWAR #191, Revision 1.

System No. of Welds Cycled Condensate Storage (CY) 1 Diesel Generator (DG) 1 Fuel Pool Cooling and Cleanup (FC) 8 Feedwater (FW) 35 Feedwater Drains - Turbine Cycle (HD) 1 Primary Ccntainment Combustion and Gas 4

Control (HG)

High Pressure Core Spray (HP) 7 Low Pressure Core Spray (LP) 5 Main Steam (MS) 51 Nuclear Boiler (NB) 1 Off Gas (OG) 3 Residual Heat Removal (RH) 49 Reactor Building and Control Floor 1

Drains to Radwaste (RF)

Reactor Core Isolation Cooling (RI) 8 Reactor Water Cleanup (RT) 3 Primary Containment Ventilation (VP) 2 Reactor Building Closed Cooling Water ('WR) 56 Service Water (WS) 54 Solid Radwaste Reprocessing and Disposal 1

(WX)

Totals:

Systems - 19; No. of Welds - 291 ic fr