Suppls & Clarifies Util Intent to Have Qualified Personnel Available to Operate post-accident Sampling Sys. Sys Will Be Staffed Only W/Chemistry Technicians in Long Term
ML20073L772
Person / Time
Site: San Onofre  Southern California Edison icon.png
Issue date: 04/19/1983
From: Baskin K
SOUTHERN CALIFORNIA EDISON CO.
To: Harold Denton
Office of Nuclear Reactor Regulation
References
NUDOCS 8304210247
Download: ML20073L772 (2)


Text

.

Southern California Edison Company gE P. O. SOX 800 2244 WALNUT GROVE AVENUE ROSEM E AD. C ALIFORNI A 91770 K. P. B AS KIN retspuo~g

" " "".'.",7 '.'~'o' ","c Cl~~ " " '"

H. R. Denton Director Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D.C.

20555 Gentlemen:

Subject:

Docket Nos. 50-361 and 50-362 San Onofre Nucleer Generating Station Units 2 and 3

Reference:

Letter from R. Dietch (SCE) to H. R. Denton (NRC) dated April 14,1983 The purpose of this letter is to supplement the reference letter and to clarify SCE's intent to have qualified personnel available to operate the Post Accident Sampling System (PASS) in the event of an accident at San Onofre Nuclear Generating Station, l' nits 2 and 3 (SONGS 2 and 3). The final Post Accident-Sampling Program (PAS Program) for SONGS 2 and 3 will include a definition of staffing requirements which are consistent with the PASS function.

At the present time there are 6 SCE chemistry technicians, 15 SCE aseistant chemistry technicians and 17 contractor chemistry technicians Igned to SONGS 2 and 3.

The staffing level is intended to be all SCE sistry technicians in the long term.

It is SCE's intent to train all

..GS 2 and 3 chemistry technicians to operate the PASS.

Clearly, it is SCE's intent to have adequate personnel available at all times that are qualified to operate the PASS. Despite any shift manning requirements, SCE would normally have qualified personnel on site to operate the PASS. Even if the personnel were not on site, given the number of chenistry technicians that will be trained, SCE would be able to call people to the site in a timely manner to respond to an emergency.

o so 8304210247 830419 PDR ADOCK 05000361 P

PDR

~

JS Mr. H. R. Denton April 19, 1983 We hope that this information satisfactorily addresses SCE's intent to have an adequate number of personnel trained and available to operate the PASS.

If you have any questions regarding this matter, please call me.

Very truly yours, cc:

J. B. Martin, Regional Administrator, Region V H. Rood (To be opened by addressee only) l

-J

_._.,___.r.

Page 1 This report addresses the following items defined in Supplement 1 to NUREG-0737.

o Safety Parameter Display System (SPDS).

o Detailed Control Room Design Review (DCRDR).

o' Regulatory Guide 1.97.

o Emergency Operating Procedures.

o Emergency Response Facilities.

Integrated Training Plan o

6 9

Pags 2 SAFETY PARAMETER DISPLAY SYSTEM

'Information Provided:

o

_ Current - Status of the SPDS Design.

Date-for submitting parameter selection safety analysis.

o o

Date when SPDS will-be operable and operators trained, o

Type of NRC review requested.

o'

' Proposed integration schedule.

Discussions:

Perry's Safety' Parameter Display System (SPDS)'is part of a package purchased from General Electric known as the Emergcacy Response Information. System (ERIS). ERISfis a two part, basic and enhanced, information package. The basic portion of the system will implement the Critical Safety Functions (CSF'S) to support an SPDS.

The basic ERIS design is approximately 75% complete. Construction of the system,has started and the system will be operable before fuel load. Operator training on the use of the SPDS will also be completed prior to fuel load.

An-NRC audit to perform a post implementation review of the SPDS is requested by the owner i

The safety analysis used to implement and select the SPDS parameters was part of our Emergency Procedure Guidelines (EPGs).

Since the Plant Emergency In-structions (PEls) are consistent with the EPGs, it then follows that the EPGs are an appropriate basis for the selection of SPDS parameters. Additional information-describing the basis for parameter selection and verification and O

Page 3 validation of the SPDS will be supplied to the NRC.six (6) months prior to fuel load.

A complete description of the SPDS can be found in a submittal forwarded to the NRC in a letter M. R. Edelman to B. J. Youngblood dated March 31, 1983.

The'SPDS will be integrated with the other NUREG-0737, Supplement l' require-monts prior to fuel load.

Paga 4 DETAILED CONTROL ROOM DESIGN REVIEW Information Provided:

o Current status of DCRDR.

o Program Plan submittal.

o Date for submittal of summary report.

Discussion:

Perry has been actively involved with the BWR Owners Group for Control Room l

Human Factors Review. A Human Factors Control Room Survey was conducted on September 21-25, 1981 in accordance with the BWR Owners Group program.

Subsequent to this, the NRC conducted their own review on August 9-13, 1982.

The NRC report from this review was issued on November 12, 1982. We are presently in the process of evaluating the NRC report and expect to issue a response to these findings shortly.

At this time, no physical control room changes for human factors have been implemented. This process is expected to begin upon completion of the response to the NRC findings. Nicholson Nuclear Science and Engineering has been retained to provide human factors expertise. A supplemental survey is being planned for late 1983 to complete the DCRDR.

The Perry Human Factors program plan was submitted to the NRC's Mr.

A. Schwencer on June 7, 1982.

As stated in the Program Plan submittal, the summary' report will be submitted' approximately six months prior to fuel' load.

~

~ -

Paga 5'

-REGULATORY GUIDE 1.97 Information Provided:

-o

.Date for implementing Regulatory Guide 1.97.

Discussion:

The variables and associated requirements of NRC Regulatory Guide 1.97, Rev.-2, have:been reviewed and utilized as guidance in CEI's plans to provide instrumentation.to assess plant and environs conditions during and following-an accident. These plans will be described in an upcoming FSAR-amendment.

Tho' installation of those items committed to for Regulatory Guide 1.97, Revision 2, as described in the. upcoming FSAR amendment, will be accomplished

-for PNPP by fuel loading except for fuel zone reactor water level.

Instrumen-tation for this variable will be installed during PNPP's Unit 1 first scheduled fuel outage.

i

'Pagn 6

+

t EMERGENCY OPERATING PROCEDURES Information Provided:

o Current status of E0P development.

o Status of generic technical guidelines.

' Date for submittal' of procedures generation package.

o o

Date for implementing E0Ps.

i -

Discussion:

The generic Emergency. Procedure Guidelines'for BWRs has been submitted to the NRC. These guidelines have been reviewed and an SER has been issued. The

-Emergency Operating Perry specific Plant Emergency Instructions will be based on the BWR EPGs. Procedures at Perry are identified as the Plant Emergency Instructions (PEIs).

The_PEIs are currently in draft form'and will be completed in enough. detail to.

support operator cold license training currently scheduled to begin May 1, 1983. The final approved PEIs will be, ready for implementation at fuel load.

The procedures' generation package will be submitted to the NRC twelve months

- prior to fuel load.

Pago 7-EMERGENCY RESPONSE FACILITIES Information Provided:

o

'Date for fully functional Technical Support Center (TSC)

Operations Support Center (OSC)'

Emergency Operations Facility (EOF)

Discussion:

The TSC, OSC, and EOF will be fully functional by fuel load of Unit 1.

A detailed description of those facilities has been submitted to the NRC staff in a letter M. R. Edelman to B. J. Youngblood dated March 31, 1983.

9 9

Pags 8 INTEGRATED TRAINING PLAN Information Provided:

o Date for completion of training plan.

Discussion:

Training of operators and other utility and site personnel has been in pro-gress for many years. Control room operator training has intensified as the initial operator cold license examinations are to be given in August 1983.

Operators are trained in the use of procedures and equipment which are effec-tive or installed as of the date of the examination.

Changes to procedures or equipment are included in the requalification training programs. For use with the August operator examinations, Plant Emergency Instructions (PEIs) shall be available and the operator trained to be proficient in their use.

Ilowever, the submission of the Procedures Generation Package will be delayed until after the initial operator licensing but prior to fuel load. This will allow revision and updating of the PEIs prior to actual fuel load. -Revisions to the PEIs will be incorporated into the requalification and initial licensing training programs and the operators trained to be proficient in their use prior to actual fuel load.

SPDS equipment, DCRDR installations, and other revisions to the Perry Plant shall generally be incorporated into the Perry Control Room Simulator and the operator trained to be prcficient-in their use prior to fuel load. Where installation into the simulator is not feasible or desirable, then revisions and additions to the Perry Plant which affect the realm of operators will be

,r-,_

Pags 9 o

included in the requalification and initial operator licensing programs prior to fuel load.

Training of operators and other site personnel in the use of Emergency Response Facility equipment'and' associated procedures shall occur prior to the Emergency Preparedness Appraisal.. Training objectives and materials are currently under development. The adequacy of ERF training shall be judged by successful completion of the Emergency Preparedness appraisal and exercise prior to actual fuel load.

Training plans for operators are currently available. Where practical, training for plant equipment and revisions shall occur prior to equipment activation. However, prior to actual fuel load, completion of user training shall not be a prerequisite for equipment installation or activation.

Revi-sions to these training programs shall be a continuous procedure occurring in due process. Stable control room operator training plans in support of NUREG-0737 Supplement I will be implemented on or before the submittal of the Procedures Generation Package. Training plans for ERF personnel shall be available as necessary to support the Emergency Preparedness appraisal.

DW63/H/9/es