ML20073A103

From kanterella
Jump to navigation Jump to search
Proposed App a Tech Spec Changes Re Limiting Safety Sys Setting,Rcs Integrity & Operating Limit Max Critical Power Ratio Values
ML20073A103
Person / Time
Site: Pilgrim
Issue date: 04/05/1983
From:
BOSTON EDISON CO.
To:
Shared Package
ML20073A090 List:
References
NUDOCS 8304110661
Download: ML20073A103 (2)


Text

..

1.2 SAFETY LIMIT 2.2 ' LIMITING SAFETY SYSTEM SETTING 1.2 REACTOR COOLANT SYSTEM INTEGRITY 2.2 REACTOR COOLANT SYSTEM INTEGRITY Applicability:

Applicability:

Applies to limits on reactor Applies to trip settings of the in-i coolant system pressure.

struments and devices which are pro-vided to prevent the reactor system safety limits from being exceeded.

Objective:

Objective:

l To establish a limit below which To define the level of the process the integrity of the reactor cool-variables at which automatic pro-ant system is not threatened due tective action is initiated to to an overpressure condition.

prevent the pressure safety limit from being exceeded.

i i

Specification:

Specification:

l i

The reactor vessel dome pressure The limiting safety system settings shall not exceed 1325 psig at any shall be as specified below:

time when irradiated fuel is pre-i sent in the reactor vessel.

l Limiting Safety Protective Action System Setting A.

Scram on Re-1085 psig l

actor Vessel l

high pressure B.

Relief / Safety Nominal setpoint valve settings will be selected be-tween 1095 and 1115 psig. All valves shall be set at this nominal setpoint +

11 psi.

C.

Safety valve 1240 psig + 13 psi settings t

1 Amendment No.

22 8304110661 830405 PDR ADDCK 05000293 P

PDR

TABLE 3.I1-1 OPERATING LIMIT MCPR VAttTS MCPR Operating Limit f

aus I!Wl1 1.0 1.41 1,44 0 to.1 1.42 1.45

.1 to.2 1.42 1.45

.2 to.3 1.43 1.46

.3 to.4 1.43 1.46

.4 to.5 1.44 1.47

.5 to.6 1.44 1.47

. 6 to.7 1.45 1.48

.7 to.8 1.45 1.48

.8 to.9 1.46 1.49

.9 to 1.0 1,46 1,49 e

Amendment No..

2053-2

-