TABLE 1A PAGE 5 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT (1982)

GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES UNIT 3RD 4TH EST. TOTAL QUARTER QUARTER ERROR, %

A.

FISSION & ACTIVATION GASES 1.

TOTAL RELEASE CI 1.27E+01 1.61E+02 2.00E+01 2.

AVERAGE RELEASE RATE FOR PERIOD UCI/SEC 1.60E+00 2.03E+01 1

  • 3.

PERCENT OF TECHNICAL SPECIFICATION LIMIT 2.08E-02 2.45E-01 B.

10 DINES 1.

IODINE - 131 CI 1.86E-05 7.10E-04 2.00E+01 2.

AVERAGE RELEASE RATE FOR PERIOD UCI/SEC 2.34E-06' 8.93E-05

    • 3.

PERCENT OF TECHNICAL SPECIFICATION LIMIT 9.31E-04 3.55E-02 C.

PARTICULATES 1.

PARTICULATES WITH HALF-LIVES > 8 DAYS CI 0.00E-01 3.06E-05 2.00E+01 2.

AVERAGE RELEASE RATE FOR PERIOD UCI/SEC 0.00E-01 3.85E-06

      • 3.

PERCENT OF TECHNICAL SPECIFICATION LIMIT 0.00E-01 2.17E-02 4.

GROSS ALPHA RADIO-ACTIVITY CI 1.26E-05 6.66E-06 D.

TRITIUM 1.

TOTAL RELEASE CI 5.67E+00 2.46E+01 2.00E+01 2.

AVERAGE RELEASE RATE FOR PERIOD UCI/SEC 7.13E-01 3.10E+00

        • 3.

PERCENT OF TECHNICAL SPECIFICATION LIMIT 1.49E-03 6.46E-03

  • BASED ON ENVIRONMENTAL TECHNICAL SPECIFICATION (ETS) 2.4.3.B(1) FOR QUARTERLY BETA FRACTION DOSE FROM NOBLE GASES.

i

    • BASED ON ETS 2.4.3.B(5) FOR THE QUARTERLY DOSE FROM I-131; 2 CI PER CALENDAR QUARTER I
      • BASED ON ETS 2.4.3.B(3) FOR THE QUARTERLY DOSE FROM ALL RADI0 IODINES AND RADIOACTIVE MATERIALS IN PARTICULATE FORM VITH HALF-LIVES GREATER THAN EIGHT DAYS.
        • BASED ON 10CFR20, APPENDIX B, TABLE II, COLUMN 1 USING 2 E-7 UCI/CC FOR HYDROGEN-3 AND ANNUAL AVERAGE X/Q OF 4.17 E-6 SEC/CU.M FROM THE FSAR.

8704010556 830323 PDR ADOCK 05000346 R

pop l

TABLE 1B Page 6 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT (1982)

GASEOUS EFFLUENTS-ELEVATED RELEASE

  • Nuclides Released Unit SE$E 9Ejj" 9{$f Qy$[~

1.

Fission gases krypton-85 Ci I E

E E'

E krypton-85m Ci E

E E

E krypton-87 Ci EI E

E E

krypton-88 Ci El E

E I.

E xenon-133 Ci E

E E l.

E xenon-135 Ci E

E E

E xenon-135m Ci E

E E

E xenon-138 Ci E

E E

E l

Others (specify)

Ci E

E E

E l

Ci E

E E

E Ci E

E E

E unidentified Ci E

E E

E Total for period Ci E

E E

E I

2.

Iodines l

iodine-131 Ci E

E E

E l l

iodine-133 Ci E

E E

E iodine-135 Ci E

E E

E E

Total for period Ci E

E E

3.

Particulates strontium-89 Ci E

E E

E strontium-90 Ci E

E E

E cesium-134 Ci E

E E

E cesium-137 Ci E

E E

E barium-lanthanum-140 Ci E

E E

E Others (specify)

Cf E

E E

E Ci E

E E

E Ci E

E E

E unidentified Ci E l.

E E

E

  • Not applicable; all releases are classified as mixed mode releases.

l l

_, ~.... - - _

e TABLE 1C PAGE 7 REVISION 1 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT (1982) MARCH 23,1983 GASEOUS EFFLUENTS MIXED MODE RELEASES CONTINUOUS MODE BATCH MODE UNIT 3RD 4TH 3RD 4TH QUARTER QUARTER QUARTER QUARTER 1.

FISSION GASES KR-85 CI 0.00E-01 0.00E-01 7.02E-01 2.18E-01 XE131M CI 0.00E-01 0.00E-01 0.00E-01 2.26E-01 XE133M CI 0.00E-01 0.00E-01 0.00E-01 1.17E-02 XE-133 CI 1.11EMI 1.42E+02 0.00E-01 1.23E+01 1

XE-135 CI 8.80E-01 6.45E+00 0.00E-01 0.00E-01 TOTAL FOR PERIOD CI 1.20 E+01 1.48E+02 7.02E-01 1.28E+01 2.

10 DINES I-131 CI 1.86E-05 7.10E-04 0.00E-01 0.00E-01 I-133 CI 0.00E-01 1.37E-04 0.00E-01 0.00E-01 TOTAL FOR PERIOD CI 1.86E-05 8.47E-04 0.00E-01 0.00E-01 3.

PARTICULATES H-3 CI 5.67E+00 2.46E+01 2.08E-03 1.42E-02 SR-89 CI 0.00E-01 1.15E-05 0.00E-01 0.00E-01 SR-90 CI 0.00E-01 1.91E-05 0.00E-01 0.00E-01 TOTAL FOR PERIOD CI 5.67E+00 2.46E+01 2.08E-03 1.42E-02

-i I

~ _.

i i

TABLE 2A I

PAGE 8 I

I i EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT (1982) l I

LIGUID EFFLUENTS - SUMMATION OF ALL RELcnocs e

i i

UNIT 3RD 4TH EST. TOTAL GUARTER GUARTER ERROR, %

A.

FISSION & ACTIVATION PRODUCTS 1.

TOTAL RELEASE (WITHOUT TRITIUM, GASES, ALPHA)

CI 2.91E-02 1.72E-03 2.00E+01

2. AVERAGE DILUTED CONCEN-TRATION DURING PERIOD UCI/ML 3.24E-07 2.40E-08
3. PERCENT OF TECHNICAL SPEC. LIMIT, 10 CI 2.91E-01 1.72E-02
  • 4.

PERCENT OF 10 CFR 20 LIMIT 5.66E-01 2.54E+00 B.

TRITIUM 1.

TOTAL RELEASE CI 1.77E+00 1.23E+01 2.00E+01

2. AVERAGE DILUTED CONCEN-TRATION DURING PERIOD UCI/ML 1.22E-05 1.55E-04
  • 3.

PERCENT OF 10 CFR 20 LIMIT 4.08E-01 5.16E+00 C.

DISSOLVED & ENTRAINED GASES 1.

TOTAL RELEASE CI 2.08E-03 3.82E-03 2.00E+61 2.

AVERAGE DILUTED CONCEN-TRATION DURING PERIOD UCI/ML 2.31E-08 5.32E-08 l

  • 3. PERCENT OF 4 E-5 UCI/CC LIMIT 5.77E-02 1.33E-01 D.

GROSS ALPHA RADI0 ACTIVITY l

l l

1. TOTAL RELEASE CI 4.73E-05 0.00E-01 2.(XIE+01 E. VOLUME OF WASTE RELEASED (PRIOR TO DILUTION)

LITERS 5.45E+05 5.24E+05 2.00E+01 F.

VOLUME OF DILUTION WATER L

i

1. DURING THE TIME OF I

RELEASES LITERS 1.44E+08 7.87E+07 2.00E+01 l

l l

l I

  • BASED ON DILUTION DURING THE TIME OF RELEASES ONLY.

l

n.

TABLE 1 PAGE 11 REVISION 1 SEMIANNUAL MAXIMUM INDIVIDUAL DOSE TABLE (CASE 0US) MARCH 23, 1983 JULY 1, 1982 THROUGH DECEMBER 31, 1982 DOSE DUE TO RELEASE OF NOBLE GAS WHOLE BODY DOSE (MREM)

CRITICAL CRITICAL CRITICAL CRITICAL CRITICAL SECTOR DISTANCE ACE ORGAN DOSE THIRD QUARTER SW 1148.(M)

NA W BODY 3.08E-06 FOURTH QUARTER NNE 966.(M)

NA W BODY 8.14E-03 1

SEMIANNUAL TOTAL NNE 966.(M)

NA W BODY 8.14E-03 SKIN DOSES (MREM)

CRITICAL CRITICAL CRITICAL CRITICAL CRITICAL SECTOR DISTANCE AGE ORGAN DOSE THIRD QUARTER SW l148.(M)

NA SKIN 3.69E-04 FOURTH QUARTER NNE 966.(M)

NA SKIN 2.32E-02 1

SEMIANNUAL TOTAL NNE 966.(M)

NA SKIN 2.36E-02 i -

I $

i t

f

TABLE 2 PAGE 12 SEMIANNUAL MAXIMUM INDIVIDUAL DOSE TABLE (GASEQUS)

JULY 1, 1982 THROUGH DEC. 31,1982 DCSE DUE TO RELEASE OF H3e C14, AND RADIGIODINES AND FARTICULATES WHOLE BODY DOSE (MREM)

CRITICAL CRITICAL CRITICAL CRITICAL CRITICAL SECTOR DISTANCE AGE ORGAN DOSE THIRD QUARTER SSE 1931.(M)

CHILD W BODY 7.87E-04 FOURTH QUARTER NNW 1287.(M)

CHILD W BODY 9.53E-03 GEMIANNUAL TOTAL NNW 1287.(M)

CHILD W BODY 9.97E-03 SIGNIFICANT ORGAN DOSES (MREM)

CRITICAL CRITICAL CRITICAL CRITICAL CRITICAL SECTOR DISTANCE AGE ORGAN DOSE THIRD QUARTER SSE 1931.(M)

CHILD THYROID 1.03E-03 FOURTH QUARTER SSE 8689.(M)

INFANT THYROID 1.06E-01 CEMIANNUAL TOTAL SSE 8689.(M)

INFANT THYROID 1.07E-01

0-l TABLE 3 PAGE 13 i

REVISION 1 SEMIANNUAL POPULATION DOSE TABLE (GASEOUS)

MARCH 23, 1983 JULY 1, 1982 THROUGH DECEMBER 31, 1982 DOSE DUE TO RELEASE OF NOBLE GAS i

TOTAL INTEGRATED AVERAGE DOSE TO INDIVIDUALS POPULATION DOSE (MANREM)

IN POPULATION (MREM) t WHOLE BODY WHOLE BODY I

l THIRD QUARTER 3.04E-05 1.37E-08 4

FOURTH QUARTER 9.38E-04 4.22E-07 1

SEMIANNUAL TOTAL 9.68E-04 4.36E-07 l

4

!j i

e t

~

0 i

,.m

-,m v

-,,w


+----------eve

- ---- - - -w

TABLE 4 PAGE 14 SEMIANNUAL POPULATION DOSE TABLE (GASEOUS)

JULY 1, 1982 THROUGH DEC. 31 1982 DOSE DUE TO RELEASE OF H3, C14, AND RADIGIODINES AND PARTICULATES TOTAL INTEGRATED AVERAGE DOSE TO INDIVIDUALS POPULATION DOSE (MANREM)

IN POPULATIDH (MREM)

WHOLE BODY WHOLE BODY THIRD QUARTER 1.73E-03 7.78E-07 FOURTH GUARTER 8.27E-03 3.72E-06 SEMIANNUAL TOTAL 1.00E-02 4.49E-06 A

.-