Revised Page 17.1-15 to Snupps Design & Const QA Program
ML20072B624
Person / Time
Site: Wolf Creek 
Issue date: 06/10/1983
From:
STANDARDIZED NUCLEAR UNIT POWER PLANT SYSTEM
To:
Shared Package
ML20072B597 List:
References
NUDOCS 8306140240
Download: ML20072B624 (3)


Text

.

11.

Identification of Change Page 17.1-15 of the SNUPPS Standard Plant PSAR Reason for Change The revised page reflects the fact that KG&E has incorporated into the QA Program a commitment to Regulatory Guide 1.146 made in response to NRC Generic Letter 81-01 dated 5/4/81.

Basis for Concluding that Revised Program Satisfies 10CFR50 Appendix B This additional commitment to the program satisfies 10CFR50 Appendix B.

k 8306140240 830610 PDR ADDCK 05000482 A

PDR

i SNUPPS IfjFJ experience may be certified based on documented written examinations and evaluations of actual work proficiency.

h.

NRC Regulatory Guide 1.64'" Quality Assurance Require-ments for the Design of Nuclear Power Plants. " (10/73) i.

NRC Regulatory Guide 1.74 " Quality Assurance Terms and Definitions."- (2/74) j.

NRC Regulatory Guide 1.88 " Collection Storage and Maintenance of Nuclear Power Plant Quality Assurance Records."

(10/.76) m

)(.

ANSI N45.2.5-1974 " Supplementary Quality Assurance Requirements for Installation, Inspection, and Testing of Structural Concrete and Structural Steel During the Construction Phase of Nuclear Power Plants."

The recommendations of this reguladory guide are met, with the exception of Section 5.4(1) of ANSI N45.2.5-1974.

Bolts are tightened using direct tension indicators in accordance with AISC Specifi-cation for Structural Joints Using ASTM A325 or A490 Bolts, approved May 8, 1974.

As a result, the g..

  • r requirement for the acceptance of tightene'd bolt as-

'2 semblies is:

"the length of the bolts shall be such that the point of the bolt will be flush with or out-side of the face of the nut when completely installed."

f~k E.

NRC Regulatory Guide 1.116, " Quality Assurance Require-ments for Installation, Inspection, and Testing of Mechanical Equipment and Systems." (6/76) 1.

sec m s-L n ar.

ANSI N45.2.12 (Draft 3, Rev. 4 - February 22, 1974)

" Requirements for Auditing of Quality Assurance l

Programs for Nuclear Power Plants."

o Hf.

ANSI N45.2.13 (Draft 2, Rev. 4 - April, 1974) " Quality Assurance Requirements for Control of Procurement of l

Items and Services for Nuclear Power Plants," including l

Regulatory staff comments and supplementay guidance, Section D of the " Gray Book" (Guidance on Quality l-Assurance Requirements During Design and Procurement Phase of Nuclear Power Plants, Rev. 1).

Codes, standards, AEC Regulatory Guides, and regulations are considered by the SNUPPS QA Committee to determine their effect on the SNUPPS utilities' quality assurance program and, as appropriate, are incorporated or referenced in the SNUPPS Standard QA Manual.

I l

17.1-15 Rev.

E o

e e

er Insert 1.

NRC Regulatory Guide 1.146 " Qualification of Quality Assurance g g, Program Audit Personnel for Nuclear Power Plants."

(8/80)

-.