0M8 N Commonwealth Edison
) ons Fu'sf N1tional PlusJhicago, Ilhnois C
O ] Address Reply to: Poi,t Office Box 767 j Chicago, Illinois 60690 June 1, 1983 Mr. James G. Keppler, Regional Administrator
- Region III U.S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, IL 60137
Subject:
Byron Generating Station Units 1 and 2 Braidwood Generating Station Units 1 and 2 Barton Instrument Accuracy NRC Docket Nos. 50-454, 50-455, 50-456, and 50-457 References (a):
January 28, 1983, letter from T. R.
Tramm to J. G. Keppler.
(b):
March 28, 1983, letter from T. R. Tramm to J. G. Keppler.
Dear Mr. Keppler:
References (a) and (b) provided interim reports on a deficiency reportable pursuant to 10 CFR 50.55(e) regarding the accuracy of Barton electronic instrument transmitters being installed at Byron and Braidwood stations.
This letter provides a third interim report.
For your tracking purposes this deficiency is numbered 82-11 for Byron and 82-12 for Braidwood.
As described in reference (b) instrument accuracy is not within specifications at elevated temperatures.
Transmitter design changes are being investigated.
In addition, changes in the allowable accuracy of these transmitters are being evaluated for each transmitter application.
A final report on this deficiency is expected to be available by August 31, 1983.
Please address *urther questions regarding this matter to the office.
Very truly yuurs,
/
i T. R.
Tramm Nuclear Licensing Administrator 1m 8306100236 830601 WN 61983 gff DR ADOCK 05000
}