Forwards List of Class IE Electric Equipment Important to Safety,Per 10CFR50.49.Schedule for Environ Qualification of Remaining Equipment Encl
ML20071H818
Person / Time
Site: Summer South Carolina Electric & Gas Company icon.png
Issue date: 05/17/1983
From: Dixon O
SOUTH CAROLINA ELECTRIC & GAS CO.
To: Harold Denton
Office of Nuclear Reactor Regulation
References
NUDOCS 8305250492
Download: ML20071H818 (30)


Text

)

o SOUTH CAROLINA ELECTRIC & GAS COMPANY POST OPPICE 764 COLuusiA. south CAROLINA 29218

. o. w. oixoN. ;n.

VICE P.E860ENr May 17, 1983

sucana o,Enariou, Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.

20555

Subject:

Virgil C. Summer Nuclear Station Docket No. 50/395 Operating License No. NPF-12 Environmental Qualification of Electric Equipment Important to Safety

Dear Mr. Denton:

As' required by 10CFR50.49 published in the Federal Register / Volume 48, No. 15/ Friday, January 21, 1983, South Carolina Electric and Gas Company (SCE&G) herein submits a list of electric equipment important to safety within the scope of the rule.

In the attachment to our letter of February 19, 1982, SCE&G provided a summary of the qualification information for most of the equipment.

In several letters -since that date SCE&G has provided additional information regarding certain pieces of equipment.

This letter summarizes the information previously submitted and provides SCE&G's schedule for qualification of the remaining pieces of equipment.

IfLyou have any questions, please let us know.

Ve tr y you s, O. W. p xon, r.

CO:NEC:OWD/fjc

Attachment:

cc:

V. C.

Summer C.

A. Price T. C. Nichols, Jr./O. W. Dixon, Jr.

.A.

R. Koon E.'H.

Crews, Jr.

C. L.-Ligon (NSRC)

E.

C. Roberts G. J. Braddick H. N..Cyrus J.

C. Miller J.

P. O'Reilly J.-L. Skolds Group / General Managers J.

B.

Knotts, Jr.

O. S.-Bradham NPCF R. B.-Claryj File (Lic./Eng.)

4 8305250492 830517 PDR ADOCK 05000395 lt40 P

pop __

Page 1 CLASS lE EQUIPMENT

. SUBJECT TO HARSH ENVIRONMENTAL CONDITIONS SYS EQUIPMENT DESCRIPTION MANUFACTURER TYPE / MOD NUMBER TAG NUMBER QUALIFIED AC 6" Motor Operated Gate Valve ROTORK 14NAl XVG7502 1

Operator XVG7503 1

AC 6" Motor Operated Gate Valve ROTORK 14NA2 XVG7501 1

Operator XVG7504 1

AH Limit' Switches for Reactor NAMCO EA-180 XDP0110A l'

Building Cooling Unit HEPA XDP0110B 1

Filter Bypass Dampers XDP0lllA 1

XDP0lllB 1

AH Limit Switch for 36" Purge NAMCO EA-180 XVB0001B 1

-Line Isolation Valve XVB0002B 1

AH

= Limit Switch for Air Damper NAMCO EA-180 XDP0012A 2

XDP0012B 2

XDP0013A 2

XDP0013B 2

AH

. Damper Actuator Solenoid ASCO 206-381-7F XDP0110A 1

Valve for Reactor Building XDP0110B 1

Cooling. Unit HEPA Bypass XDP0lllA 1

Damper XDP0lllB 1

-AH Reactor Building Cooling Unit RELIANCE 5003UCZ MFN0097A 1

Fan Emergency Motor MFN0097B 1

MFN0097C 1

MFN0097D 1

J

c-

-f r

Page 2

' CLASS lE EQUIPMENT SUBJECT TO HARSH ENVIRONMENTAL CONDITIONS

'SYS EQUIPMENT-DESCRIPTION MANUFACTURER TYPE / MOD NUMBER TAG NUMBER QUALIFIED z-AH

.' Solenoid Valve for-36" Purge ASCO NP-8316 XVB0001B 1

-Line-Isolation Valve XVB0002B 1

~AH Solenoid Valves for Air ASCO NP-8320 XDP0012A 2-XDP0012B 2

Dampers XDP0013A 2

XDP0013B 2

BD-3" Air Operated Gate Valve ASCO NP-8316 XVG503A 1

Solenoid XVG503B 1

XVG503C 1

.BD 3" Air Operated Gate Valve

.NAMCO EA-180 XVG503A 1.

Limit Switch XVG503B 1

XVG503C 1

CC '_

8" Motor Operated Gate LIMITORQUE SMB-000-5 XVG9605--

1

~

Valve Operator

'CC 4" Air. Operated Gate ASCO NP-8316 XVG9627A 1

l Valve Solenoid XVG9627B 1

CC 8" Motor Operated Gate LIMITORQUE SMB-000-5 XVG9568 1

Valve Operator XVG9606 1

--CC' 3" Motor Operated Gate LIMITORQUE SMB-000-2 XVG9600 2

Valve Operator CC' 8" Motor' Operated Gate LIMITORQUE SMB-000-5 XVG9625 2

Valve Operator-XVG9626 2

a

Page 3 CLASS lE EQUIPMENT SUBJECT TO HARSH ENVIRONMENTAL CONDITIONS SYS EQUIPMENT DESCRIPTION MANUFACTURER TYPE / MOD NUMBER TAG NUMBER' QUALIFIED CC

'16" Motor. Operated Butterfly LIMITORQUE SMB0005/H2BC XVB9526B 1

Valve. Operator XVB9687B-1"

-XVB9526A 1

'XVB9687A 1'

~

CC.

20" Motor Operated Butterfly LIMITORQUE SMB0005/H2BC

-XVB9503A

_1 Valve Operator XVB9503B 1

CC 16" Motor Operated Butterfly LIMITORQUE SMB0005/H2BC XVB9524A

'2

. Valve Operator XVB9524B 2

XVB9525A 2

.XVB9525B 2

CC Component Cooling Water Pump WESTINGHOUSE LRA PAM/3840 Frame

MPP0001A, 1

. Motor MPP0001B 1

MPP0001C 1

CC Component Cooling Water Flow ROSEMOUNT ll53DA4 IFT7263A 2

To Reactor Coolant Pump IFT7263B 2

Bearings CC' Component Cooling Water Surge ROSEMOUNT ll52DP4 ILT7092 1

-Tank Level Transmitters ILT7094 1

CC Component Cooling Water Flow ROSEMOUNT ll53DA4 IFT7273A 2

To Reactor Cooling Pump IFT7273B 2

Thermal Barriers

-J

6 Page 4 CLASS lE EQUIPMENT SUBJECT TO HARSH ENVIRONMENTAL CONDITIONS SYS EQUIPMENT DESCRIPTION MANUFACTURER TYPE / MOD NUMBER TAG NUMBER QUALIFIED 1

. CC-

4" Air Operated Gate Valve NAMCO EA-180

.XVG9627A Limit Switch XVG9627B 1

CI' RTD, Reactor Building PYCO 122-1010 ITE9201 1

Temperature ITE9203 1

CS 2". Globe Valve Motor LIMITORQUE SMB-00-10

.XVT8104 1

' Operator XVT8109A.

1 XVT8109B-1 XVT8109C 1

XVT8100 1

' CS 4" Gate Valve Motor LIMITORQUE SB-00 LCV115C 1-

, Operator LCVll5E 1

CS 8" Gate Valve Motor LIMITORQUE SB-00 LCVll5B 1

Operator LCVll5D 1

CS 1-1/2" Globe Valve Motor LIMITORQUE SMB-00-10 XVT8102A 1

. Operator XVT8102B 1

XVT8102C 1

- CS 8" Gate Valve Motor LIMITORQUE SB-00 XVG8130A 1

Operator XVG8130B 1

XVG8131A 1

XVG8131B 1

4 e

s.

j c
Page. 5 CLASS lE EQUIPMENT SUBJECT TO HARSH ENVIRONMENTAL CONDITIONS SYS EQUIPMENT DESCRIPTION MANUFACTURER TYPE / MOD NUMBER TAG NUMBER -QUALIFIED LIMITORQUE SB-00 XVG8132A 1

-CS 4" Gate Valve-Motor Operator XVG8132B' l

XVG8133A 1

XVGW133B 1

iCS-3"'Ga'te Valve Motor LIMITORQUE SB-00 XVG8106 l'

-Operator XVG8107 1

'/

XVG8108 1

CS' 2". Globe. Valve Motor LIMITORQUE SMB-00-10 XVT8112 1

Operator

<- ' 3" Globe. Valve Solenoid ASCO NP-831654V XVT8152 1

CS CS 2"~ Globe Valve Solenoid ASCO.

NP-831654V XVT8149A 1

./

'?

XVT8149C 1

XVT8149B 1.

M s l p

CS" Stem-Mounted Limit. Switch NAMCO EA-180 XVT8152 1

f:

4,,7 CS. ' Charging' Pump Motor WESTINGHOUSE 6809 XPP0043A 1

XPP0043B 1

XPP0043C 1

LCS Safety Injection Pump TERAC GOULD HPL-C XET2002C 1

~

. Transfer Switch' i

i,

~.

,J W H"a

.,,,)^h,, w,Z

- N

. M;. ' -

u e -.

, p" c,

\\;

^

A L

u g.,

g.q t

.=

p.. ~ 't :

g '-

N' y(

k-9 -

-[ 7. _

J

],,

."- (

y~, 4 s

s s

r-e-

i

, r L

\\'

r yw 4,,_ ;j ';

.(

v Page 6

,O'y w. q, 5

(

1' s->t

^

~

2 a

s... _.s 4

~ ' :s

  • C"-

i-4'

> CLASS 1E EQUIPMENT A

w7

,.Stia.7ECT TO~ HARSH ENVIRONMENTAL CONDITIONS 6

'3,,,+i

'Q 5 ' p n

-3 t,

e SYS EQUIPMENT DESCRIPTION

+ MANUFACTORER TYPE / MOD NUMBER TAG NUMBER QUALIFIED

~-

4 CS-Boric Acid Tank Level' BARTON 752 ILT106 2

' Transmitter ILT108 2

ILT161 2

ILT163 2

EF 6" Motor Operated Gate LIMITORQUE SMB-00-5 XVG1001A 1

Valve Operator-XVG1001B 1

EF 8" Motor Operated Gate LIMITORQUE SMB-000-5 XVG1002 1

Valve Operator XVG1008 1

XVG1037A 1

1 XVG1037B 1

b, EF Emergency Feedwater Pump ASCO WP-HVA-206-IFV3531 1

Flow Control Valve Solenoid 381-3RVU IFV3536 1

IFV3541 1

IFV3546 1

IFV3551 1

IFV3556 1

EF 4" Swing Check Valve ASCO 206-381-3F XVC1009A 2

Solenoid XVC1009B 2

XVC1009C 2

EF Emergency Feedwater Pump GENERAL ELECTRIC K Horizontal MPP0021A 1

Motor Frame 8311Z MPP0021B 1

5K831155C7 SK831155C8 es a

s Page 7 CLASS lE EQUIPMENT SUBJECT TO HARSH ENVIRONMENTAL CONDITIONS SYS EQUIPMENT DESCRIPTION MANUFACTURER TYPE / MOD NUMBER TAG NUMBER QUALIFIED EF Motor Driven Emergency ROSEMOUNT ll53DA5 IFT3531 1

Feedwater Pump Discharge IFT3551

-1 Header Flow IFT3541 1

EF Emergency Feedwater to ROSEMOUNT ll53DA4 IFT3561 1

Steam Generator Flow IFT3571 1

IFT3581 1

4 EF Emergency Feedwater to ROSEMOUNT ll53DA5 IFT35SlA 1

Steam Generator.A Flow EF Emergency Feedwater to ROSEMOUNT ll53DA5 IFT3571A 1

Steam Generator B Flow EF Emergency Feedwater to ROSEMOUNT ll53DA5 IFT3581A 1

Steam Generator C Flow ES Motor Control Center SQUARE D Model 4 XMClDA2Y 2

ES Valve Canister Pentration D.G. O'BRIEN Valve Container, XRP0100A 1

l-lSC #4 XRP0100B 1

XRP0101A 1

XRP0101B 1

ES Outside Containment Plugs D.G. O'BRIEN T/Model XRP0100A 1

C-32 Plugs XRP0100B 1

Valve Canister XRP0101A 1

Penetrator XRP0lOlB 1

g w

c-

t Page ' 8 -

CLASS'lE EQUIPMENT SUBJECT TO HARSH ENVIRONMENTAL ~ CONDITIONS

. SYS EQUIPMENT DESCRIPTION MANUFACTURER TYPE / MOD NUMBER TAG NUMBER. QUALIFIED ES Electrical Penetration D.G. O'BRIEN Low Voltage.

XRP0007 1

Power / Control XRP0010 1

Components XRP00ll 1

With Exception XRP0014 1

of C-32 Plugs XRP0017 1

XRP0028 1

XRP0030 1

ES Electrical Penetration D.G. O'BRIEN Instrumentation XRP0035 1

Components XRP0036 1

With Exception XRP0043 1

4 of C-32 Plugs XRP0044 1

XRP0045 1

XRP0046 1

XRP0048 1

i XRP0051 1

' ES' Electrical Penetration D.G. O'BRIEN C-32 Plugs XRP0010 1

Plugs Outside Containment Low Voltage XRP00ll 1

Power Control-XRP0017 1

XRP0028 1

XRP0030 1

Electrical' Penetration.

D.G. O'BRIEN C-32 Plugs XRP0035 1

ES-

' Plugs Outside Containment Instrumentation XRP0036 1

4' XRP0043 1

XRP0044 1

XRP0045 1

XRP0046 l'

XRP0048-1 XRP0051 1

i l

ve

- ~

~,

Page 9 CLASS lE EQUIPMENT SUBJECT TO HARSH ENVIRONMENTAL CONDITIONS SYS EQUIPMENT DESCRIPTION MANUFACTURER TYPE / MOD NUMBER TAG NUMBER QUALIFIED

'ES Electrical Penetration Triax D.G. O'BRIEN Triax Connector XRP0043 2

Connectors Module M06 XRP0044 2

Plug R191010G04 XRP0045 2

XRP0046 2

D.G. O'BRIEN Triax Connector XRP0051A 4

(Victoreen High Range Monitor)

ES Power Transfer and Motor FIELD FABRICATED XPN0040 2

Control Panel for Charging Pump C Auxiliaries ET.

Isolation Fuses In Heat GOULD/SHAWMUT N/A XPN2005 1

Tracing Panels FUSES XPN2006 1

XPN2007 1

XPN2008 1

XPN2009 1

XPN2010 1

ET l Isolation Fuse Blocks in BRYANT 1917 XPN2005 4

Heat Tracing' Panels ELECTRIC 3929 XPN2006 4

XPN2007 4

XPN2008 4

XPN2009 4

XPN2010 4

~

~

\\

T Page 10; P

4 oCLASS lE EQUIPMENT SUBJECT TO HARSH ENVIRONMENTAL CONDITIONS

-SYS EQUIPMENT DESCRIPTION MANUFACTURER TYPE / MOD NUMBER TAG NUMBER QUALIFIED:

.FS' 4" Motor Operated Gate LIMITORQUE SMB-000-5 XVG6797 2

Valve Operator,

FWL Feedwater-Flow DP. Transmitter BARTON 752 IFT0476 2-IFT0477 2

IFT0486-2 IFT0487-2 IFT0496 2

IFT0497 2

FW 3" Air. Operated Globe Valve ASCO NP-8316 XVT1678A 1

Solenoid '

XVT1678B 1

XVT1678C 1

' ~

-FW 1-1/2". Motor Operated Valve LIMITORQUE SMB-00 XVT1633A 1

Operator XVT1633B-2 XVT1633C 2

FW

'18"I Air-Hydraulic Globe SKINNER V5H61 XVG1611A 1

' Valve Solenoid XVG1611B 1

XVG1611C 1

FW.

3" Air Operated Globe Valve NAMCO EA-180 XVT1678A 1

Limit' Switch XVT1678B 1

XVT1678C 1

-FW 18" Air-Hydraulic Globe NAMCO EA-180 XVG1611A 1

Valve Limit Switch XVG1611B 1

XVG1611C 1

i

-.~.

r

~

Page 11 CLASS lE EQUIPMENT SUBJECT TO HARSH ENVIRONMENTAL CONDITIONS-

'SYS EQUIPMENT DESCRIPTION MANUFACTURER TYPE / MOD NUMBER TAG NUMBER QUALIFIED HR' Hydrogen Recombiner WESTINGHOUSE XHR0004A 1

XHR0004B 1

XPN0049A 2

HR '.

Hydrogen Recombiner Control WESTINGHOUSE Panels and'. Power Supply XPN0049B 2

XPN0050A 2

XPN0050B 2

'HR-6" Air Operated Gate ASCO NP-8316 XVG6056 1-Valve' Solenoid' HR-6"' Purge Isolation ASCO NP-8316 XVG6066 1

Valve Solenoid XVG6067 1

HR.

' Post Accident Hydrogen VALCOR V526-5292-20 XVX6050A 1

-Removal System Isolation XVX6050B 1

Solenoid valves XVX6051A 1

XVX6051B 1

XVX6051C-1 t

XVX6052A 1

t XVX6053A 1

XVX6054 1

HR Reactor: Building Wide Range ROSEMOUNT 1152AP7 IPT0954A 1

Pressure HR Narrow Range Containment BARTON 752 IPT950 2

Pressure Transmitter IPT953 2

t Page 12 CLASS 1E EQUIPMENT SUBJECT TO HARSH ENVIRONMENTAL CONDITIONS SYS EQUIPMENT DESCRIPTION MANUFACTURER TYPE / MOD NUMBER TAG NUMBER. QUALIFIED HR 6" Air' Operated Gate NAMCO EA-180 XVG6056 1

Valve Limit Switch HR 6" Purge Isolation Valve NAMCO EA-180 XVG6066 1

. Limit Switch XVG6067 1

HR Reactor Building Hydrogen COMSIP, INC.

KIII XPN7215A 2

Analyzer Panel and Remote XPN7258A 2

Control Panel XPN72588 2

- IA 6" Air Operated Globe Valve ASCO NP-8316 XPN2662B 1

Solenoid XPN2662A 1

IA 2" Air Operated Globe Valve ASCO NP-8323 XV'r2660 1

Solenoid IA 6" Air Operated Globe Valve NAMCO EA-180 XVT2662B 1

~

Limit Switch XVT2662A 1

IA 2" Air Operted Glove Valve NAMCO EA-180 XVT2660 1

Limit. Switch LD Electronic Transmitter, ROSEMOUNT 01153-0022-0001 ILT1969 1

Reactor Building RHR.

ILT1970 1

Sump Level LD

. Electronic Transmitter, ROSEMOUNT 01153-0022-0001 ILT1975 1

Reactor Building Level ILT1976 1

x - _. _

U

.=.

Page 13 CL7p'i lE EQUIPMENT SUBJECT TO HARS.1 ENVIRONMENTAL CONDITIONS

. S,YS - EQUIPMENT DESCRIPTION MANUFACTURER TYPE / MOD NUMBER TAG NUMBER QUALIFIED MS Steam' Generator Level BARTON ILT0474 1

Narrow Range DP ILT0475 1

Trnasmitters ILT0476 1

ILT0484 1

ILT0485 1

ILT0486 1

ILT0494 1

ILT0495 1

ILT0496 1

MS First Stage Turbine BARTON 752 IPT446 2

Pressure Transmitter IPT447 2

MS Steam Flow DP Transmitter BARTON IFT0474 2

IPT0475 2

IFT0484 2

IFT0485 2

IFT0494 2

IFT0495 2

Page 14 CLASS lE EQUIPMENT SUBJECT TO HARSH ENVIRONMENTAL CONDITIONS SYS EQUIPMENT DESCRIPTION MANUFACTURER TYPE / MOD NUMBER TAG NUMBER QUALIFIED MS Steam Pressure Transmitter BARTON IPT0474 1

IPT0475 1

IPT0476 1

IPT0484 1

IPT0485 1

IPT0486 1

IPT0494 1

IPT0495 1

IPT0496 1

MS Control Solenoid.

ASCO WP-HVA-206-381-IFV2030 1

3RVU MS 32" Air Operated Isolation ALLIED 321X-21 XVM2801A 1

Valve Solenoid XVM2801B-1 XVM2801C 1

MS 4" Air Operated Globe Valve ASCO NP-8316 XVT2869A 1

Solenoid XVT2869B 1

XVT2869C 1

MS

<4" Motor Operated Gate Valve LIMITORQUE SMB-00 XVG2802A 1

. Operator XVG2802B 1

-MS 1-1/2" Air Operated Globe ASCO NP-8323 XVT2843A 1

Valve Solenoid XVT2843B 1

XVT2843C 1

XVT2877A 1

XVT2877B 1

y p,o.

4 r

i y,-

i e

4 L

(

Page 15 5

CLASS lE EQUIPMENT SUBJECT-TO HARSH ENVIRONMENTAL CONDITIONS.

-SYS EQUIPMENT DESCRIPTION-MANUFACTURER-TYPE / MOD NUMBER TAG NUMBER QUALIFIED.

. MS-Steam Generator' Power.

ASCO

'WP-HVA-206-381-IPV2000 1

Relief Control Solenoid Valve 3RVU.

IPV2010 1

h IPV2020 1

6

. MS.

32". Air-. Operated.; Isolation NAMCO EA-740 XVM2801A 1-I

-Valve Limit Switch

-XVM2801B-1 XVM2801C 1

' MS 4"1 Air-' Operated Glove Valve NAMCO.

EA-180

.XVT2869A 1.

Limit Switch XVT2869B 1-XVT2869C 1-

...1-1/2" Air Operated Globe..

NAMCO EA-180-XVT2843A

~ 1

. MS-Valve. Limit-Switch XVT2843B 1

XVT2843C 1-XVT2877A 1

XVT2877B 1

1 l

.ND 3" Air Operated Diaphragm ASCO 206-381-3RFV XVD6242A 1

Valve Solenoid NP-1 XVD6242B l

ND 3" Air ~ Operated. Diaphragm NAMCO EA-180 XVD6242A 1

l

-Valve: Limit Switch XVD6242B 1

1:

4 NI Power R'ange Neutron Detector WESTINGHOUSE Dual Section NC-41 2

Ionization NC-42 2

Chamber NC-43 2

4-NC-44 2

1 4.

L - -

-s

Page 16 CLASS lE EQUIPMENT SUBJECT TO HARSH ENVIRONMENTAL CONDITIONS SYS EQUIPMENT DESCRIPTION MANUFACTURER TYPE / MOD NUMBER TAG NUMBER QUALIFIED RC

. Narrow Range Resistance RdF ITE0412A 5._

Temperature Detector.

ITE0412B 5

ITE0412C 5

ITE0412D 5

ITE0422A

5 ITE0422B-5 ITE0422C 5

ITE0422D 5

-ITE0432A 5

ITE0432B 5

ITE0432C 5-ITE0432D 5

. :RC Wide Range Resistance PYCO 122-3006 ITE0410/

Temperature Detector 0410A 1

ITE0413/

0413A 1

ITE0420/

0420A 1

ITE0423/

0423A 1

ITE0430/

0430A 1-ITE0433/

0433A 1

g, s>-

7 Page 17; CLASS lE EQUIPMENT SUBJECT TO HARSH ENVIRONMENTAL CONDITIONS SYS EQUIPMENT DESCRIPTION MANUFACTURER-TYPE / MOD NUMBER TAG NUMBER QUALIFIED

'RC

' Reactor Coolant Flow'DP BARTON 752 IFT0414-2

.Transmiter IFT0415 2

IFT0416-2

IFT0424, 2

IFT0425 2-IFT0426 2

IFT0434 2

IFT0435 2

IFT0436 2

'. RC - - Pressurizer Pressure BARTON IPT0455 1

Transmitter IPT0456 1

IPT0457.

1 RC Pressurizer Level DP BARTON IPT0459 1

Transmitter IPT0460 1

IPT0461 1

RC-

.. Reactor l Coolant System BARTON IPT0402~

l

' Wide Range Pressure Transmitter

.RC-Reactor Coolant. System VERITRAK IPT0403 3

Wide. Range' Pressure 4

-Transmitter

. RC.

'1" Diaphragm Valve-Limit NAMCO EA-180 XVD8047:

1 Switch 5

j

Page 18 CLASS lE EQUIPMENT SUBJECT TO HARSH ENVIRONMENTAL CONDITIONS SYS EQUIPMENT DESCRIPTION MANUFACTURER TYPE / MOD NUMBER TAG NUMBER QUALIFIED RC 1" Diaphagm. Valve Solen'.sid ASCO NP-831654V XVD8047 1

RC-Diaphragm Valve Solenoid ASCO.

NP-831654V XVD8033 1

XVD8028 1

4 RC' 2" Motor Operated Globe LIMITORQUE SMB-00 XVT8095A 1

Valve Operator XVT8095B 1

XVT8096A 1

XVT8096B 1

RC Stem Mounted Limit Switch NAMCO EA-180 XVD8033 1

XVD8028 1

RC 3" Diaphragm Valve Limit.

NAMCO EA-180 PCV444B 1

Switch PCV445A 1

PCV445B 1

1 RC 3"' Diaphragm Valve Solenoid ASCO NP-831654V PCV444B 1

PCV445A 1

PCV445B 1

RH 8" Gate' Valve Motor Operator LIMITORQUE SB-00 XVG8706A 1

XVG8706B 1

i

)

.s

+

Page 19 CLASS lE EQUIPMENT SUBJECT TO HARSH ENVIRONMENTAL CONDITIONS SYS EQUIPMENT DESCRIPTION MANUFACTURER TYPE / MOD NUMBER TAG NUMBER QUALITIED

'RH

.2" Globe Valve Motor LIMITORQUE SMB-00-10 FCV602A.

1 Operator FCV602B l'

RH-12". Gate Valve Operator LIMITORQUE SB-2 XVG8701A

'1 XVG8701B 1

XVGP702A 1

XVG8702B 1

'RH RHR Pump Motor WESTINGHOUSE 5008 XPP0031A 1

XPP0031B 1

RH-Stem Mounted Limit Switch NAMCO EA-180 XVG8706A 1

XVG8706B 1

RH 12" Gate Valve Limit Switch NAMCO EA-180 XVG8701B 1

XVG8702A 1

RM Containment High. Range Area.

VICTOREEN 877-1 With RMG0018 1

Monitor Detector Connector and Cable SI 3" Gate Valve Motor LIMITORQUE SB-00.

XVG8884 1

~ Operator XVG8885 1

XVG8886 1

i

Paga 20

+

CLASS lE EQUIPMENT SUBJECT TO HARSH ENVIRONMENTAL CONDITIONS SYS EQUIPMENT DESCRIPTION MANUFACTURER TYPE / MOD NUMBER TAG NUMBER QUALIFIED SI 14" Gate Valve Motor LIMITORQUE SB-2 XVG8811A 1

Operator XVG8811B 1

XVG8812A 1

XVG8812B l-XVG8809A 1

XVG8809B 1

SI 12" Gate Valve LIMITORQUE SBD-3 XVG8808A 2

Motor Operators XVG8808B 2

XVG8808C 2

SI 10" Gate Valve Motor LIMITORQUE SB-1 XVG8887A 1

Operator XVG8887B 1

SI 10" Gate Valve Motor LIMITORQUE SBD-3 XVG8888A 1

Operator XVG8888B 1

XVG8889 1

SI 3" Gate Valve Motor LIMITORQUE SB-00 XVG8801A 1

Operated XVG8801B 1

XVG8803A 1

XVG8803B 1

SI 3/d" Globe Valve Solenoid ASCO NP-831654V XVT8871 1

SI 1" Globe Valve Solenoid ASCO NP-331654v XVT8880 1

XVT8860 1

Page 21 CLASS lE EQUIPMENT SUBJECT TO HARSH ENVIRONMENTAL CONDITIONS SYS EQUIPMENT DESCRIPTION MANUFACTURER TYPE / MOD NUMBER TAG NUMBER QUALIFIED SI 14" Gate Valve Limit Switch NAMCO EA-180 XVG8809A 1

XVG8809B 1

SI 3/4" Globe Valve ASCO NP-831654V XVT8961 1

SI Stem Mounted Limit Switch NAMCO EA-180 XVT8880 1

XVT8860 1

XVT8961 1

SI 3/4" Glove Valve Limit NAMCO EA-180 XVT8871 1

Switch SP 10" Motor Operated Gate LIMITORQUE SMB-00-15 XVG3003A 1

Valve Operator XVG3003B 1

SP 12" Motor Operated Gate LIMITORQUE SMB-005-10 XVG3001A 1

Valve Operator XVG3001B 1

SP 3" Motor Operated Gate LIMITORQUE SMB-000-2 XVG3002A 1

l 1

Valve Operator XVG3002B 1

SP 12" Motor Operated Gate LIMITORQUE SMB-00-5 XVG3004A 1

Valve Operator XVG3004B 1

XVG3005A 1

XVG3005B 1

SP Reactor Building Spray GENERAL ELECTRIC K Horizontal MPP0038A 1

Pump Motor Frame 8210S MPP0038B 1

SK 821055C44

--i 1

s

,c

~Page-22 CLASS lE EQUIPMENT.

~

SUBJECT TO HARSH ENVIRONMENTAL CONDITIONS SYS ~ EQUIPMENT DESCRIPTION MANUFACTURER TYPE / MOD NUMBER TAG NUMBER -QUALIFIED ROSEMOUNT ll53DA4 IFT7368-1-

- SP;-

-Reactor Building Spray' IFT7378

.1

. Pump. Discharge Flow

~

SE.

1" Air' Operated Ball ASCO.

NP832lA5E-XVA9311A-1.

Valve Solenoid XVA9312A ~

1-XVA9311B 1-XVA9312B 1

. SS-

. Nuclear-Sampling System VALCOR V526-5293-6 XVX9356A

-1

-Isolation Solenoid valves XVX9356B l-XVX9339 1

XVX9364B 1

XVX9364C 1-XVX9357 1

XVX9365B 1

XVX9365C' l

XVX9387 1.

XVX9398A 1

~XVX9398B

.1 XVX9398C 1

i SS 1" Air Operated Ball Valve NAMCO EA-180 XVA9311A 1.

. Limit-Switch XVA9312A 1

.)

XVA9311B 1

XVA9312B 1

9

Page 23 CLASS lE EQUIPMENT SUBJECT TO HARSH ENVIRONMENTAL CONDITIONS SYS -EQUIPMENT DESCRIPTION MANUFACTURER TYPE / MOD NUMBER TAG NUMBER QUALIFIED SW

'16". Motor Operated Gate LIMITORQUE SMB-00-15 XVG3103A 1

Valve Operator XVG3107A 1

SW 12" Motor' Operated Gate LIMITORQUE SMB-00-10 XVG3111A 1

Valve Operator XVG3112A 1

SW 2" Air Operated Globe ASCO NP8323 XVT3164 1

Valve Solenoid XVT3165 1

XVT3169 1

SW 16" Motor Operated Butterfly LIMITORQUE SMB002/H2BC XVB3100A 1

Valve Operator SW 12" Motor Operated Butterfly LIMITORQUE SMB0002/H0BC XVB3110A 1

Valve Operator SW Service Water Booster Pump LOUIS ALLIS COG 5B/449TS MPP0045A 2

Motor Frame MPP0045B 2

SW

.RTD, Service Water PYCO 122-4030-ITE4467 1

Temperature Out Of Reactor Building Cooling Units SW-Service Water Booster Pump ROSEMOUNT ll53DA4 IFT4466 1

Discharge Flow IFT4496 1

SW 2" Air Operated Globe Valve NAMCO EA-180 XVT3164 1

Limit Switch XVT3165 1

XVT3169 1

4

4 Page 24 CLASS lE EQUIPMENT SUBJECT TO HARSH ENVIRONMENTAL CONDITIONS SYS EQUIPMENT DESCRIPTION MANUFACTURER TYPE / MOD NUMBER TAG NUMBER QUALIFIED VL Emergency Feedwater Pump RELIANCE TEAO XFN0083A 2

Area Coolig Unit Fan Motor XFN0083B 2

VL Service Water Booster Pump RELIANCE TEAO XFN0081A 2

Area Cooling Unit Fan XFN0081B 2

VL RHR/ Spray Pump From Cooling RELIANCE TEAO XFN0049A 1

Unit Fan Motor XFN0049B 1

VL Charging Pump Room Cooling RELIANCE TEAO XFN0046A 1

Unit Fan Motor XFN0046B 1

XFN0047 1

VL Auxiliary Building Motor RELIANCE TEAO XFN0132 2

Control Center and Switch-gear Air Handling Unit Fan Motor VU 2" Air Operated Globe ASCO NP8323 XVT6384A 1

Valve Solenoid XVT6384B 1

XVT6385A 1

XVT6385B 1

VU Air Operated Globe NAMCO EA-180 XVT6384A 1

Valve Limit Switches XVT6384B 1

XVT6385A 1

XVT6385B 1

O.

e Page 25 CLASS lE EQUIPMENT SUBJECT TO HARSH ENVIRONMENTAL CONDITIONS SYS EQUIPMENT DESCRIPTION MANUFACTURER-TYPE / MOD NUMBER TAG NUMBER-QUALIFIED WL 3" Globe Valve Solenoid ASCO 206-381-6RVU LCV1003 1

NP-831654V XVD7136 1

WL 3/4" Globe Valve Solenoid ASCO NP-831654V XVD7126 1

XVD7150 1

WL

'3/4" Globe Valve Limit NAMCO EA-180 XVD7126 1

Switch XVD7150 1

WL 3" Globe Valve Limit NAMCO EA-180 XVD7136 1

Switch 600 Volt Control Cable ROCKBESTOS Firewall III EK-B3(*)

1 600 volt Control Cable KERITE FR-FR EK-Bl(*)

1 600 Volt Power Cable KERITE HT-FR EK-A2(*)

1 EK-A3(*)

1

'Special Instrument Cable OKONITE Okozel EK-C6,A,B, C,(*)

1 Instrument Cable SAMUEL MOORE EPDM - HYPALON EK-Cl(*)

1 (3D and 3J) 6 8 KV Power Cable OKONITE EPR - HYPALON EK-Al(*)

1 Triaxial Cable BOSTON XLPE-TEFZEL EK-C2A(*)

2 INSULATED WIRE XLPE-HYPALON EK-C2B(*)

2

-Page.26 CLASS lE EQUIPMENT SUBJECT TO HARSH ENVIRONMENTAL CONDITIONS SYS EQUIPMENT DESCRI FION-MANUFACTURER TYPE / MOD NUMBER TAG NUMBER QUALIFIED Switchboard Wire ROCKBESTOS Firewall SIS EK-J9(*)

1 2/C #18 Twinax Cable BRAND REX TCD95285 EK-Cl2B(*)

1 ROCKBESTOS RSS-6-ll2 EK-J9C(*)

2 Switchboard Wire RAYCHEM Flamtrol EK-J2(*)

1 Heat Tracing RAYCHEM 10PTV1 EK-Hl(*)

1 Miscellaneous Connectors D.G. O'BRIEN C39P0001-G01 EL-44AA(*)

1 C42P5008G-G01 1

Low Voltage Power Terminations Sleeve RAYCHEM WCSF-N EK-I9A, 20A, 21A(*)

1 Motor Termination Kit RAYCHEM N-MCK EK-121B, 21C(*)

1 Kerite Splice KERITE S-2NS-NUC EK-I4B(*)

1 EK-I8A(*)

1 EK-ISA(*)

1 EK-I4C(*)

1 Terminal Blocks STATES ZWM EN-6 (*)

1 EN-74(*)

1

Page 27 CLASS lE EQUIPMENT SUBJECT TO HARSH ENVIRONMENTAL CONDITIONS SYS EQUIPMENT DESCRIPTION MANUFACTURER TYPE / MOD NUMBER TAG NUMBER QUALIFIED 8 KV Cable Terminations Terminal Insulating Material

. Insulating Tape OKONITE T95 EKI3A9(*)

1 Jacketing Tape OKONITE T35 EKI3B(*)

1 Cement OKONITE 604-45-8104 EKI3C(*)

1 8'KV Cable Terminations For Component Cooling RAYCHEM Thermofit EKI2E(*)

1 Water Pump Motor HVT-CBN

or Charging Pump Motor RAYCHEM Thermofit EKI2E(*)

1 and Transfer Switch HVT-CBN For Emergency Feedwater Pump RAYCHEM Thermofit EKI2E(*)

1 HVT-CBN For Spray Pump Motor RAYCHEM Thermofit EKI2E(*)

1 HVT-CBN

Page 28 CLASS lE EQUIPMENT SUBJECT TO HARSH ENVIRONMENTAL CONDITIONS SYS EQUIPMENT DESCRIPTION MANUFACTURER TYPE / MOD NUMBER TAG NUMBER QUALIFIED Control Cable Terminations RAYCHEM WCSF-N EKI9A (*1 1

Splicing Sleeve EK120A(*)

1 Cable Breakout Type V RAYCHEM 302A812-52 EK19B (*)

1 Stube Connection Splice Kits RAYCHEM.

NPKV EK-I20B, 1

20C(*)

1 AMP Connectors AMP 36906 EK-J1(*)

1 321280 Terminal Blocks

' STATES ZWM EN-6 (*)

1 EN-74(*)

1 Instrument Cable Terminations RAYCHEM WCSF-N EK-19A(*)

1 EK-I20A(*)

1 EK-I21A(*)

1

  • Bill of Material. Number 1.

. Qualified.

See Revision 4 of Virgil C.

Summer Nuclear Station, Environmental Qualification of Safety Related Electrical Equipment per NUREG 0588 provided February 19, 1982.

2.

Exempt from Qualification.

See document described in (1) above.

3.

Qualified.

Information provided November 3, 1982.

4.

Qualified.

Information provided September 29, 1982.

5.

Qualified.

Information provided July 23, 1982.

o EQUIPMENT WHOSE QUALIFICATION IS INCOMPLETE 1.

Reactor Vessel Level Indication System (RVLIS)

As discussed in our letter of March 8, 1983, the Westinghouse RVLIS system installed has been approved by the Staf f as documented in Generic Letter 82-28.

Westinghouse has recently provided South Carolina Electric and Gas Company (SCE&G) the_ test reports documenting the IEEE 323-1974 harsh environment qualification for the Barton Model 581 Hydraulic Isolators, the Barton Model 353 High Volume Sensors and the MINCO Model S8809 and S8810 RTDs which are installed.

The review, acceptance and placement of the test reports in the equipment qualification file will be complete by the end of the second refueling outage after March 31, 1982 or by March 31, 1985 whichever is earlier.

2.

Pressurizer Safety Valve Position Indication Switches As discussed in our letter of September 29, 1982, prototype switches have successfully completed all phases of environmental qualification testing up to the LOCA/MSLB.

The vendor, Crosby Valve, is develop-ing a retest schedule.

The retest and submittal of the test report by the vendor and the review, accep-tance and placement of the documentation in the equipment qualification file by SCE&G will be complete by the end of the second refueling outage after March 31, 1982 or by March 31, 1985 whichever is earlier.

-3.

Core'Subcooling Monitor System As discussed in our letter of March 8, 1983, avail-ability of qualified incore thermocouple connectors, cable and other required hardware is being investi-gated.

Hardware procurement and delivery limitations prohibit installation prior to our estimated first refueling outage.

When the equipment is procured, the qualification documentation will be obtained, reviewed, approved and placed in the equipment qualification file.

This will be complete by the end of the second refueling outage after March 31, 1982 or by March 31, 1985 whichever is earlier.

_.