From: Fiedler P
GENERAL PUBLIC UTILITIES CORP.
To: Jordan E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
References
REF-SSINS-6820 IEB-81-03, IEB-81-3, NUDOCS 8302280213
Download: ML20071B385 (2)


Text

a GPU Nuclear NQQIg7 P.O. Box 388 Forked River, New Jersey 08731 609-693-6000 Writer's Direct Dial Number February 24, 1983 Edward L. Jordan, Director gO Division of Eugineering and Quality Assurance Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, D.C.

20555

Dear Mr. Jordan:

Subj ect: Oyster Creek Nuclear Generating Station IE Bulletin No. 81-03, Request for Additional Information On May 29, 1981, GPU Nuclear Corporation submitted it's response to IE Bulletin No. 81-03 Flow Blockage of Cooling Water to Safety Components by Corbicuin sp. (Asiatic Clam) and hytilus sp. (Mussel). Subsequently, on December 23, 1982, GPU Nuclear Corporation received your letter dated December 20, 1983, requesting additional information concerning the subject bulletin.

While CPUN has initiated appropriate action to respond to your request; because of the dedication of ef fort required to adequately and completely address these questions and the concurrent requirement of personnel devoted, prior to, and during the present refueling and maintenance outage, CPUN will submit it's response by August 19, 1983.

This is based upon the following considerations:

(1) it will be necessary to develop a program of inspection and a method to more ef fectively monitor the condition of the heat exchangers, and (2) develop and execute a program of study to evalute alternative methods to control biofouling. This evaluation will be based upon the technical adequacy of each design and current environmental considerations, such as the recent U.S. Environmental Protection Agency ruling for chlorine minimization, to reduce the af feet on the receiving waters.

In closing, it is our opinion that such an extention is not excessim, given the magnitude of the aformentioned undertaking.

t 0302280213 830224 PDR ADOCK 05000219 Q

PDR GPU Nuclear is a part of the General Public Utihties System

If you require additional information, or have any questions please do not hesitate to contact Mr. Douglas Moore of our Licensing and Regulatory Af fairs Department at (609) 971-4630.

Very truly yours, 4