Forwards Table 2 Inadvertently Omitted from 830114 Tech Spec Change Request 105.All Actuated Equipment Associated W/Esf Actuation Sys Testing Reviewed,Per 830117 Request
ML20070N030
Person / Time
Site: Crystal River 
Issue date: 01/20/1983
From: Westafer G
FLORIDA POWER CORP.
To: Harold Denton, Stolz J
Office of Nuclear Reactor Regulation
Shared Package
ML20070N034 List:
References
3F-0183-19, 3F-183-19, TAC-49356, NUDOCS 8301250403
Download: ML20070N030 (2)


Text

..

e cs h &+D9

(?) ?:p

%Qs.f}d[

JD4 9 E:cac*

Florida Power COAPOmafense January 20,1983 3F-0183-19 Mr. H. R. Denton, Director Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Attention:

John F. Stoltz, Citief Operating Reactors Branch #4

Subject:

Crystal River Unit 3 Docket No. 50-302 Operating License No. DPR-72 Technical Specification Change Request No.105

Dear Mr. Denton:

This supplements my letter of January 14, 1983 which submitted Technical Specification Change Request No.105. Table 2, which was inadvertantly not included in the Technical Specification submittal, is attached. As requested by your Staff, during our meeting on January 17,1983, we have reviewed all the " actuated equipment associated" with the ESFAS testing addressed by the Change Request to identify the last time their operability was verified by means other than the subject test and at what frequency they were thus tested.

The results are as follows:

(1)

All pumps are tested monthly.

(2)

All but four of the valves were tested in either December or January. Those tested in December (approximately 25% of the total) are tested every cold shutdown of sufficient duration.

Those tested in January are tested on a quarterly basis and will continue to be. BSV-Il and 12 have been deleted from ESFAS as part of the resolution of the Moderator Dilution Concerns (see Amendment 17 to the CR-3 Operating License dated January 4,1979). BSV-36 and 37 are tested on a Refueling frequency due to concerns with regard to Sodium Hydroxide introduction into the RCS.

fDl S

h l

B301250403 830120 DR ADOCK 05000 General Office 32ci Tn.rty-tourtn street soutn. P O. Box 14042. St Petersburg. Florida 33733 e 813-866-5151

8 3F-0183-19 Page,

l l

(3)

The following other equipment also is actuated by the subject ESFAS Functional I

Units.

l a.

EDG-A Emergency Diesel Generator A Tested - Monthly b.

AHF-1 A RB Normal and Emergency Tested - Refueling

-l AHF-1B Cooling Fans Tested - Refueling AHF-lC Tested - Refueling c.

AHF-15A DCP-1A Fan Cooler Units Tested - Monthly AHF-15B Tested - Monthly d.

UVLO Undervoltage Lockout (ES Bus A) Tested - Refueling e.

3ESAR Control Complex Cooling System Recirculation Lineup Tested - Refueling We have reviewed your proposed interim resolution of the testing concern (a footnote temporarily exempting FPC from the subject testing requirements until Refuel IV) and concur with that approach. We look forward to further dialogue on the long term resolution.

l Sincerely, s/

, $ c'N l

G. R. Westafer Manager Nuclear Licensing and Fuel Management KRW/ mig Attachment 1