s o **:yy

[4

.k L#flTED STATES NUCLE AR REGULATORY COMMiS$10N 5

W A8Hild0 TON, D. C. MM6 GEORGIA POW [R COMPANY OGLETHORPE POWER CORPORATION MUNICIPAL ELECTRIC AUTHORITY OF,dEORGIA CITY OF DALTON, GEORGIA DOCKET NO. 50-424 YOGTLE ELECTRIC GENERATING PLANT, UNIT 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 38 License No. hPT-68 1.

The Nuclear Regulatory Comission (the Comission) hcs found that:

A.

The application-for amendment to the Vogtle Electric Generating Plant, Unit 1 (the f acility) Facility Operating License No. NPF 68 filed by the Georgia Power Company, acting for itself, Oglathorpe Power Corpo-ration, Municipal Electric Authority of Georgia, rd City of Dalton, Georgia (the licensees) dated May 8, 1989, complies with the standards and requirements of the Atemic Energy /ict of 1954, as amended (the Act), and the Comission's rules and renulations set forth in 10 CFR Chapter 11 8.

The facility will operate in conformity with the application, the provisions of the Act, and the. rules and regulations of the Comission C.

There is reasonable ast,urance (i) that the activities au horized by this amendment can be conducted without endangering tbs Aealth and safetyofthepublic,and-(ii)thatsuchactivitieswC1beconducted in compliance with the Comission's regulations set f ath in 10 CrR Chapter It i

The issuance of this license amendment will not be inimical to the D.

.:ommon defense and security or to the health and safety of the public; and E..

The issuance of this amendment is n accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.

pA'5 88n @ "y

9 s

2 2.

Accordingly, the license is hereby amended by page changes to the Technical Specificatier,s as indicated in the attachnient to this licenst amendment and paragr aph 2.C.(2) of f ecility Operating License No. NPT 68 is heret'y aratnded to read 65 follows:

Technical Specifications and Environmental Protection Plan The Technical Specifications contained in Appendix A, as revised through Amendn4nt No. 38, and the Environmental Protection Plan contained in Appendix B, both of which are att6ched hereto, are hereby Incorporated into this license. GPC shall operate the f acility in accctdance with the Technical Specifications and the Environn: ental Protection Plar..

3.

This license amendrncht is effective as of its date cf issuance and shall bt irnplemented within 30 days of issuar.ce.

FOR THE NUCLEAR REGULATORY COMMIS$10N 41 David B. Matthews, Director Project Directorate 11-3 Divisior, of Reactor Projects - 1/11 Office of Nuclear Reactor Regulation

Attachment:

Technical Specification Changes Date of Issuance:

March 18. 1991 l

{

I

i t

go u:

UNITED 8 TATE S

[,.

"n NUCLE AR REGULATORY COMMISSION f'

W ASHlfv0708v, D. C. 7066b P

%, e... *,/

GEORGIA POWER COMPANY OGLETHORPE POWER CORPORATION MUNICIPAL ELECTRIC AUTHORITY OF GEORGIA CITY OF DALTON GEORGIA 4

DOCKE1 i!0. 50 425 V0GTLE ELECTRIC GENERATING PLANT, UNIT 2 AMENDMENT TO TACILITY_ OPERATING LICIHSE i

Amendment No. 18 License No. NPF-81

-1.

The Nuclear Regulatory Commission (the Commission) has found thatt A.

The application for amendment to the Vogtle Electric Generating Plant.

Unit 2 (the facility) Facility Operating Licenso No NPF-81 filed by the Georgia Power Company, acting for itself, Oglethorpe Pcwer Corpo-ration, Municipal Electric Authority of Georgia, and City of Dalton, Georgia (the licensees) dated May 8, 1989, compiles with the standards and requirements of the Atoalic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter 16 B.

The facility will operate in conforr.ity Oith the application, the provisions of the Act, and the rules and regulations of the Commission:

C.

There is reasonable assurance (1) that the activities authorized by this amendment can be condur.ted without endangering the health and safety of the public, and (ii) that such activities will be conducted in comp'iiance with the Commission's regulations set forth in 10 CfR Chapter Il D.

The issuance of this license amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuanr* ** this amendment is in accordance with 10 CFR Part 51 of the CL

. u,n's regulations and'all applicable requirerents have been satisfied.

2 t

2.

Accordingly, the license is hereby anithded by page changes to the Technical Specifications es indicated in the attachtrent to this license amendment and paragraph 2.C.(2) of Facility Operating License No. NPT 81 is heri:by ataended to read as follows:

Technical Specificetions and Er.vironmental Protecticn Plan The Technical Specifications contained in Appendix A, as revised through /vnendn.ent No. 18, and the Environn. ental Protection Plen conteined in Appendix B, both of which are t.ttached hereto, are hereby incorporated into this license.

GPC shall operate the facility in acccrdefece with the Technical Specifications and the Environn: ental Protection Plan.

3.

This license amendment is effective as of its date of issuance and shall be impleniented within 30 days of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION Sff Jur Davio B. Matthews, Director Project Directorate 11-3 Division of Reactor Projects - 1/11 Office of Nuclear Reactor Regulation

Attachment:

Technical Specification Changes Date of Issuance:

March 18, 1991

ATTACHMENT TO LICENSE AME,NDMENT NO. 38 FACILITY OPERAT!hG LICENSE NO. NPF-68 AND LICENSE AMENDMENT N0.18 FACILITY OPERATING LICENSE NO. NPF-81

_ DOCKET NOS. 50-424 AND 50-425 Replace the following page of the Appendix 'A" Technical Specifications with the enclosed page. The revised page is identified by Amendment number and contains vertical lines indicating the areas of change.

Remove Page Insert Page 3/4 3-28 3/4 3-28 I

1 1

1 TABLE 3.3-3 h

ENGINEERED SAFETY FEATURES ACTUATION SYSTEM INSTRUMENTATION TRIP SETPOINTS TOTAL SENSOR m

ALLOWANCE ERROR E

C FUNCTIONAL UNIT (TA)

Z (S)

TRIP SETPOINT ALLOWABLE VALUE 7

1.

Safety Injection (Reactor Trip, Feedwater Isolation, Component y

Cooling Water, Control Room Emergency Filtration System Actuation, Start m

Diesel Generators, Containment Cooling Fans, Nuclear Service Cooling Water, Containment Isolation, Containment Ventilation Isolation, and Auxiliary Feedwater Motor-Driven Pumps) a.

Manual Initiation N.A.

N.A.

N.A.

N.A.

N.A.

l b.

Automatic Actuation Logic N.A.

N.A.

N.A.

N.A.

N.A.

w}

and Actuation Relays y

c.

Containrent Pressure--High 1 2.7 0.71 1.67

$ 3.8 psig

-< 4.4 psig g

(PI-0934, PI-0935. PI-0936) d.

Pressurizer Pressure--Low 21.25 18.36 1.67 1 1870 psig 1 1856 psig I

(PI-0455A,B&C, PI-0456 & PI-0456A, PI-0457 & PI-0457A, PI-0458 &

PI-0458A) e.

Steam Line Pressure--Low 13.0 10.71 1.67 3 585 psig*

2 570 psig (LOOP 1 LOOP 2 LOOP 3 LOOP 4 PI-0514A,0&C PI-0524A&B PI-LW34A&B PI-0544A,B&C PI-0515A PI-0525A PI-0535A PI-0545A PI-0516A PI-0526A PI-0536A PI-0546A) 2.

Containment Spray a.

Manual Initiation N.A.

N.A.

N.A.

N.A.

N.A.

b.

Automatic Actuation Logic N.A.

N.A.

N.A.

N.A.

N.A.

and Actuation Relays c.

Containment Pressure--High-3 3.1 0.71 1.67

$ 21.5 psig

$ 22.4 psig (PI-0934, PI-0935, PI-0936 PI-0937)