ML20070C112

From kanterella
Jump to navigation Jump to search
Seventh Interim Deficiency Rept Re Miscategorization of Main Feedwater & Containment Isolation Valves.Initially Reported on 810106.Atwood & Morrill Seismic & Stress Rept Re Swing Check Valves Qualification Approved.Next Rept by 830331
ML20070C112
Person / Time
Site: Bellefonte  
Issue date: 12/06/1982
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
10CFR-050.55E, 10CFR-50.55E, NUDOCS 8212140047
Download: ML20070C112 (2)


Text

j'.

~,

w TENNESSEE VALLEY AUTHORITY CH ATTANOOGA. TENNESSEE 374ot 400 Chestnut Street Tower II December 6, 1982 s

BLRD-50-438/81-09 BLRD-50-439/81-09

.3 C

U.S. Nuclear Regulatory Commission h

[, h.

Region II m

'zg Attn:

Mr. James P. O'Reilly, Regional Administrator 3

7.,

101 Marietta Street, Suite 3100 o-ff Atlanta, Georgia 30303

Dear Mr. O'Reilly:

?

BELLEFONTE NUCLEAR PLANT UNITS 1 AND 2 - TAIN FEEDWATER AND CONTAINMENT.c ISOLATION VALVE MISCATEGORIZATION - BLRD-50-438/81-09, BLRD-50-439/81,

SEVENTH INTERIM REPORT The subject deficiency was initially reported to NRC-0IE Inspector M. Thomas on January 6,1981, in accordance with 10 CFR 50.55(e) as NCR BLN BLP 8015. This was followed by our interim reports dated February 5, May 6, August 18, and November 17, 1981 and March 19 and-July 29, 1982. Enclosed is our seventh interim report. We expect to submit our next report by March 31, 1983 If you have any questions concerning this matter, please get in touch with R. H. Shell at FTS 858-2688.

Very truly yours, l

TENUE 3SEE VALLEY AUTHORITY,.

DS W h L. M. Mills, Manager i

Nuclear Licensing n

Enclosure cc:

Mr. Richard C. DeYoung, Director (Enclosure)

J Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, D.C.

20555 l

oyytctabCFL w

B212140047 821206 PDR ADOCK 05000438 l

9 PDR An Equal Opportunity Employcr i

+

f, ENCLOSURE BELLEFONTE NUCLEAR PLANT UNITS 1 AND 2 MAIN EEEDWATER AND CONTAINMEfff ISOLATION VALVE MISCATEGORIZATION NCR BLN BLP 8015 BLRD-50-438/81-09, BLRD-50-439/81-09 10 CFR 50.55(e)

SEVENTH INTERIM REPORT Description of Deficiency The following 20" valves are identified as Seismic Category I (active) by design criteria documents. They were inadvertently specified and purchased as Seismic Category I(L) (i.e., limited seismic requirements).

UNID No.

Mark No.

Item No.

Contract Vendor 1 & 2CF-VKEB-080-U 3BWO401-CF-01 408 77K38-86163-8 Borg-Warner 1 & 2CF-VKEB-031-B 3BWO401-CF-01 408 77K38-86163-8 Borg-Warner 412 76K38-86163-1 Atwood and Morrill 1 & 2CF-VCES-36-N 3BWo401-CF-10 ~ 412 76K38-86163-1 Atwood and Morrill 1 & 2CF-VCEB-87-N 3BWO401-CF-10 The Borg-Warner valves are motor-operated gate valves, and the Atwood and Morrill valves are swing check type.

Interim Progress Atwood and Morrill has submitted to TVA the seismic and stress report for qualification of the swing check valves to Seismi'c Category I (active) requirements. TVA has reviewed and approved this report.

Borg-War.ner has submitted a qualification report on the hydraulic operators for the gate valves. TVA has reviewed the qualification report and returned the report to Borg-Warner requesting clarification on certain items in the report. TVA vill review the revised qualification report when it is submitted by Borg-Warner.

1

'\\

1

~

l i

_ _ _ _ _