OFERATING DATA REFORT DOCrET NO 50-413 DATE hne 15. 1994 l

OPERATING STATUS COMPLETED BY R.A. Willians TELEPHONE 704-392-5346

1. Unit Nase: Catawba 1
2. Reporting Period: flay 1,1994-May 31,1994
3. Licensed Thermal Power (MWt): 3411 1
4. Naseplate Rating (Gross NWe): 13051 Notes fNaseplate Rating  !
5. Design Electrical Rating (Net MWe): 1145 (Bross MWel calculated as
6. Maxieue Dependable Capacity (Gross MWe): 1192 1450.000 MVA r .90 power factor per Page iii, l
7. Maxisus Dependable Capacity (Net MWe): 1129 B. If Changes Occur in Capacity Ratings (itens Nuater 3 Through 7) Since Last NUREG-0020.

Report. Give Reasons:

9. Power Level To Which Restricted, if Any (Net MWe): j
10. Reason For Restrictions, if any:

l i

1 This Month Yr.-to-Datt Cumulative

11. Hours in Reporting Period 744.0 3623.0 78216.0
12. Number Of Hours Reactor Was Critical 744.0 3596.6 59374.6
13. Reactor Reserve Shutdown Hours --0-- --0-- --0--

l 14. Hours Generator Dn-Line 744.0 35B5.1 5B239.5 l --0--

15. Unit Reserve Shutdown Hours --0-- --0--
16. Bross Thermal Energy Generated (MWH) 2518583 11921835 189164371
17. Gross Electrical Energy Generated (MWH) 899056 4266817 66630952
18. Net Electrical Energy Benerated (MWH) 851526 4043715 625B8344
19. Unit Service Factor 100.0 99.0 74.5
20. Unit Availability factor 100.0 99.0 74.5
21. Unit Capacity Factor (Using MDC Net) 101.4 98.9 70.6
22. Unit Capacity Factor (using DER Net) 100.0 97.5 69.9
23. Unit Forced Outage Rate 0.0 1.0 9,8
24. Shutdown Scheduled Over Next 6 Months (Type, Date, and Duration of Eachi:

None

25. If Shut Down At End Of Report Period. Estinated Date of Startup:
26. Units In Test Status (Prior te Cosmercial Operation): Forecast Achieved INITIAL CRITICALITY INITIAL ELECTRICITY ~

COMMERCIAL OFERATICN i

l l 9406210247 940615 l PDR ADOCK 05000413 R PDR

9 OPERATINS DATA REPORT l

l DOCKET ND 50-413 UNIT Catawba 1 DATE June 15. 1994 l

COMPLETED BY R.A. Williams '

TELEPHONE 704-382-5346 l

l A0 NTH May. 1994 -

DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net) (MWe-Net)  ;

1 1135 17 1149 2 1146 18 1150 )

3 1147 19 1151 4 1147 20 1151 5 1147 21 1149 6 1131 22  !!46 7 1144 23 1143 8 114B 24 1140 9 1150 25 1140 1

10 1147 26 1137 l 11 1146 27  !!43 12 1144 2B  !!45 13 1151 29 1141 14 1148 30 1143 15 1141 31 1139 1

16 1142

UliIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO. 50-613 UNIT NAME carawua 1 DATE ue/13/94 REPORT MONTH May 1994 COMPLETED BY x. a. wlbuland TELEPHONE (zug)-asz-o;46 (1) (2 (3) (4) (5)

A)

E ggt _

HOD T A OF LICENSE N Y S SHUT EVENT SYS- CAUSE AND CORRECTIVE O P DURATION O DOWN REPORT TEM COMPONENT ACTION TO

. DATE E HOURS N R/X NO. CODE CODE PREVENT RECURRENCE NO SHUTDOWNS OR REDUCTION S .

(il (2) (3) (4) r Forced Reason

  • Method: Exhibit G - Instructions S Scheduled A-Equipment Failure (Explain) 1-Manual for Prenaration of, Data B-Maintenance or test 2-Manual Scram Entry Sheets For Licensee C-Refueling 3-Automatic Scram (LER D-Regulatory Restriction , ,

4-Other (Explain) Event File Report (NUREG-0361))

E-Operator Training & License Examination F-Administrative (5)

G-Operator Error Exhibit I - Same Source H-Other (Explain) (Explain)

4 DOCITf: 50-413 UNIT: Catawba 1 Date: 06/15/94 NARRATIVE

SUMMARY

Mor m l: May 1994 Catawba Unit 1 began the month of May operating at 100% full power. 'Ibe unit operated at or near 100% full power for the entire month.

1 Prepared by: R. A. Williams Telephone: (704)-382-5346

l

. \

1 l

MONTHLY REFUELING INFORMATION REQUEST j l

1. Facility name: Catawba, Unit 1  ;

i

2. Scheduled next refueling shutdown: February 1995 l
3. Scheduled restart following refueling: April 1995 THE PROJECT MANAGER HAS BEEN ADVISED BY SEPARATE COMMUNICATION OF ANY T.S. CHANGE OR LICENSE AMENDMENT. THEREFORE, QUESTIONS 4 THROUGH 6 WILL NO LONGER BE MAINTAINED IN THIS REPORT.
4. Will refueling or resumption of operation thereafter require a technical specification change or other licence amendment?

If yes, what will these be?

If no, has reload design and core configuration been reviewed by Safety Review Committee regarding unreviewed safety questions?

5. Scheduled date(s) for submitting proposed licensing action and supporting information.
6. Important licensing considerations (new or different design or supplier, unreviewed design or performance analysis methods, significant changes in design or new operating procedures).
7. Number of Fuel assemblies (a) in the core: 193 (b) in the spent fuel pool: 484
8. Present licensed fuel pool capacity: 1418 Size of requested or planned increase: ---
9. Projected date of last refueling which can be accommodated by present licensed capacity: September 2009 DUKE POWER COMPANY DATE: June 15, 1994 Name of

Contact:

R. A. Williams Phone: (704)-382-5346 l l

l 1

OPERATING DATA REPORT DOCKET ND 50-414 DATE June 15, 1994 OPERATING STATUS COMPLETED BY R.A. Willians TELEPHONE 704-382-5346

1. Unit Name: Catawba 2
2. Reporting Period: May 1, 1994-May 31, 1994
3. Licensed Thermal Power (MWt): 3411
4. Naseplate Rating (Bross MWe): 1305f Notes eNaseplateFating
5. Design Electrical Rating (Net MWe): 1145 (Gross MWel calculated as
6. Baximus Dependable Capacity (Bross MWe): 1192 1450.000 MVA .90 power
7. Razieus Dependable Capacity (Net MWe):  !!29 factor per Page iii, B. If Changes Occur in Capacity Ratings (Itess Number 3 Through 7) Since Last NUREG-0020.

Report. Give Reasons:

, i l

9. Pcwer Level To Which Restricted, If Any (Net MWe):  !

l 10. Reason for Restrictions, if any: i l

l l

This Month- Yr.-to-Date Cumulative l

11. Hours In Reporting Period 744.0 3623.0 68232.0
12. Number Of Hours Reactor Was Critical 0.0 2854.2 52795.1
13. Reactor Reserve Shutdown Hours --0-- --0-- --0--
14. Hours Generator On-Line 0.0 2818.8 51898.3
15. Unit Reserve Shutdown Hours --0-- --0-- --0--
16. Bross Thersal Energy Generated (MWH) 0 9140659 166029698
17. Gross Electrical Energy Generated IMWH) 0 3290126 $8857395
12. Net Electrical Erergy Benerated (MWH) -5092 3104507 55394564 l
19. Unit Service Factor 0.0 77.B 76.1
20. Unit Availability Fatter 0.0 77.0 76.1
21. Unit Capacity Fatter (Usirg MDC Net) 0.0 75.9 71.7 l 22. Unit Capacity Factor (Using DER Net) 0.0 74.6 70.9 l 23. Unit Forced Outage Rate 0.0 1.2 9.2 l 24. Shutdown Scheduled Over Next 6 Months (Type, Date, and Duration of Each):

Currentlv Refitol 4no

25. If Shut Down At End Of Report Period. Estiaated Date of Startup: June 27. 1994
26. Units in Test Status (Prior to Ceasercial Operation): Forecast Achieved INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OFERATION I

r

a OPERATING DATA REPORT DOCKET ND 50-414 UNIT Catawba P l

DATE June 15,1994 l

COMPLETED BY R.A. Williaris )

TELEPHONE 704-382-5346 MONTH May, 1994 D61 AVERASE DAILY F0WER LEVEL pal AVERABE DAILY' POWER LEVEL' ,,

(MWe-Net) (MWe-Net) l e 1 0 17 0

?

2 0 18 0 3 0 19 0 4 0 20 0 5 0 21 0 6 0 32 0 1

7. 0 23 0 I B 0 24 0 9 0 25 0 l

10 0 26 0 11 0 27 0 i

12 0 28 0 13 0 29 0 14 0 30 0 15 0 31 0 16 0 l

l l

l I

1

. . _ , , _ , _ , . . , . . _ , . . ._..,_.,,__..,.,....-_,,,,,.,a

UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO. 50-414 UNIT NAME carawna z DATE ub/lo/94 REPORT MONTH May 1994 COMPLETED BY x. a. widoland TELEPHONE ( / v 4 ) 5 62-o.5 4 o (1) (2 (31 (4) (5)

A)

E MEI-HOD T A OF LICENSE N Y S SHUT EVENT SYS- CAUSE AND CORRECTIVE O P DURATION O DOWN REPORT TEM COMPONENT ACTION TO

. DATE E HOURS N R/X NO. CODE CODE PREVENT RECURRENCE 2 94 1 S 744.00 C --

RC FUELXX END-OF-CYCLE 6 REFUELING OUTAGE (1) (2) (3) (4)

F Forced Reason- Method: Exhibit G - Instructions

, S Scheduled A-Equipment Failure (Explain) 1-Manual for Preparation of, Data

! B-Maintenance or test 2-Manual Scram Entry Sheets For Licensee C-Refueling 3-Automatic Scram Event Report (LER D-Regulatory Restriction 4-Other (Explain) File (NUREG-0161))

E-Operator Training & License Examination i F-Administrative (5) l G-Operator Error Exhibit I - Same Source I H-Other (Explain) (Explain)

j .

DOQGT: 50-414 UNIT: Catawba 2 Date: 06/15/94 NARRATIVE SUIEARY I MONIN: May 1994 l

l Catawba Unit 2 began the month of May in end-of-cycle 6 refueling outage. 'Ihe unit l

t was in the refueling outage for the entire month.

I t

l l

l l

Prepared by: R. A. Williams Telephone: (704)-382-5346

l , .

MONTHLY REFUELING INFORMATION REOUEST

1. Facility name: Catawba, [1. nit 2
2. Scheduled next refueling shutdown: Currently Refuelina
3. Scheduled restart following refueling: June 1994 THE PROJECT MANAGER HAS BEEN ADVISED BY SEPARATE COMMUNICATION OF ANY T.S. CHANGE OR LICENSE AMENDMENT. THEREFORE, QUESTIONS 4 THROUGH 6 WILL NO LONGER BE MAINTAINED IN THIS REPORT.
4. Will refueling or resumption of operation thereafter require a technical specification change or other licence amendment?

If yes, what will these be?

l If no, has reload design and core configuration been reviewed by Safety Review Committee regarding unreviewed safety questions?

i

5. Scheduled date(s) for submitting proposed licensing action and supporting information.
6. Important licensing considerations (new or different design or supplier, unreviewed design or performance analysis methods,

[ significant changes in design or new operating procedures).

7. Number of Fuel assemblies (a) in the core: 193 (b) in the spent fuel pool: 444
8. Present licensed fuel pool capacity: 1418 Size of requested or planned increase: ---
9. Projected date of last refueling which can be accommodated by present licensed capacity: September 2011 DUKE POWER COMPANY DATE: June 15, 1994 Name of

Contact:

R. A. Williams Phone: (704)-382-5346 i