P A

A t t Ac e,,r-7 2

NUCLEAR ENERGY BUSINESS GROUP

ERRATA And ADDENDA T.1. E. NO.

79NED273 LOCA ANALYSIS REPORT FOR TITLE O

NO.

DRESDEN UNITS 2, 3 AND QUAD September 1982 DATE CITIES 1,2 NUCLEAR POWER STATIONS NOTE: Correct allcopies of the applicable ISSUE DATE April 1979 publication as specified below.

REFERENCES INSTRUCTIONS P RAG APH L NE)

(CORRECTIONS AND ADDITIONS) 1.

Page 4-10 Replace with new page 4-10.

(Change brackets in right-hand margin indicate areas where report has been revised.)

8210250177 821018 1 gg y PDR ADOCK 05000237 PAGE P

PDR

NEDO-24146A Table 4E MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE l

l PLANT: Dresden 2,3/ Quad Cities 1,2 FUEL TYPE: 8D250 Average Planar Exposure MAPLHGR PCT 0xidation (mwd /t)

(kW/ft)

(*F)

Fraction 200 11.2 2106 0.024 1,000 11.3 2109 0.024 5,000 11.9 2169 0.029 10,000 12.1 2179 0.029 15,000 12.2 2198 0.031 20,000 12.0 2199 0.031 25,000 11.5 2148 0.027 30,000 10.6 2020 0.017 35,000 9.6 1888 0.011 40,000 9.0 1808 0.008 Table 4F MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE PLANT: Dresden 2,3/ Quad Cities 1,2 FUEL TYPE: 8D262 Average Planar Exposure MAPLHGR PCT 0xidation (mwd /t)

(kW/ft)

(*F)

Fraction 200 11.1 2104 0.024 1,000 11.3 2107 0.024 5,000 11.9 2166 0.029 10,000 12.1 2175 0.029 15,000 12.2 2199 0.031 l

20,000 12.0 2199 0.032 25,000 11.6 2157 0.028 20,000 10.7 2042 0.019 35,000 9.8 1915 0.012 1

40,000 9.2 1831 0.009 l

4-9 l

NEDO-24146A f

Table 4G MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE PLANT: Dresden 2,3/ Quad Cities 1,2 FUEL TYPE:

8DRB265L Average Planar Exposure FMPLHGR PCT 0xidation

__ mwd /t)

(kW/ft)

(*F)

Fraction

(

200 11.6 2189 0.035-1,000 11.6 2188 0.034 5,000 11.8 2198 0.034 10,000 11.9 2196 0.033 15,000 11.9 2198 0.034 20,000 11.7 2195 0.034 25,000 11.3 2154 0.030 30,000 10.7 2075 0.023 35,000 10.2 2002 0.018 40,000 9.6 1913 0.013 Table 4H MAPLHCR VERSUS AVERAGE PLANAR EXPOSURE PLANT: Quad Cities 1 FUEL TYPE:

Barrier LTA Average Planar Exposure MAPLHGR PCT 0xidation

(!!Wd/ t)

(kW/ft)

(*F)

Fraction 200 11.6 2171 0.032 1,000 11.6 2178 0.033 5,000 12.0 2198 0.034 10,000 12.1 2195 0.033 15,000 12.0 2200 0.033 20,000 11.7 2187 0.032 25,000 11.0 2115 0.056 30,000 10.5 2029 0.042 40,000 9.3 1913 0.013

]

k 4-10