Amend 5 to License NPF-11,allowing RCS to Be Demonstrated Capable,Using Test Flow Path Delivering 600 Gpm to Reactor Vessel
ML20069E868
Person / Time
Site: LaSalle 
Issue date: 08/27/1982
From: Schwencer A
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20069E870 List:
References
NUDOCS 8209270064
Download: ML20069E868 (14)


Text

'

C0rtl0NWEALTH EDIS0tl CO'IPANY DOCKET H0. 50-373 LA SALLE COUNTY STATION, UNIT 1 Ar1Eh0 MENT TO FACILITY OPERATING LICENSE License No. NPF-il Amendment No. 5 1.

The Nuclear Regulatory Conmission (the Commission or the NRC) having found that:

A.

The application for amendment by the Connonwealth Edison Company, dated August 11, 1932, complies with the standards and requirements of the Atomic Energy Act of 1954, as acended (the Act), and the Conmission's regulations set forth in 10 CFR Chapter I; 3.

The facility will operate in confornity with the application, the provisions of the Act, and the regulations of the Connission; C.

There is reasonable assurance:

(1) that the activities authorized by this amendaent can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comnission's regulations; D.

The issuance of this anendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this anencnent is in accordance with 10 CFR Part 51 of the Comnission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachnent to this license amendment and paragraph 2.C.(2) of the Facility Operating License No. NPF-ll is hereby acended to read as follows:

(2) The Technical Specifications contained in Appendices A and B, as revised through Arendment No. 5, are hereby incorporated in the license.

The licensee shall operate the facility in accordance with the Technical Speci fications.

8209270064 820827 PDR ADOCK 05000373 P

ppg J.'

i e.,,c.,

ee-m.e>

[

omey l

OFFIClAL RECORD COPY n,mu im_ mm oc roau aia oo-sea nacu oua

i

- 3.

This amendment is effective as of August 13, 1982.

FOR Tile NUCLEAR REGULATORY C0tNISSIO!!

A. Schwencer, Chief Licensing Branch flo. 2 Division of Licensing Attachments:

Changes to the Technical Specifications Date of Issuance:

el,

/

OFFICE) 5 I

.E6yl(ton.:kW.

.Afl0

.i. a..

.Asghwgncer..

..$.CM suamuc h 0/I. /$2 9/.6/.q2

@/M/,@2

'q[g,)/,[.

oarr )

f.RO FORM 313 (10 N) r.RCM C24)

OFFICIAL RECORD COPY

- i m - m vo s

~.

ATTACli!1ENT TO LICENSE AME!JD:!Er!T NO. 5 FACILITY OPERATING LICENSE NO. NPF-ll DOCKET No. 50-373 Replace the following pages of the Appendix "A" Technical Specifications with the enclosed pages. The revised pages are identified by Amendment number and contain vertical lines indicating the area of change.

REHJVE INSERT 3/4 7-8 3/4 7-8 B 3/4 7-1 B 3/4 7-1 3/4 6-120 3/4 6-12a 3/4 7-33 3/4 7-33 3/4 7-35 3/4 7-35 3/4 7-36 3/4 7-36 3/4 7-37 3/4 7-37 3/4 7-40 3/4 7-40 3/4 7-42 3/4 7-42 3/4 7-43 3/4 7-43 3/4 7-45 3/4 7-45 o,nce>

sun ~4ue )

~~

oare >

Lac ronu us oa4a nacu om OFFiClAL RECORD COPY usom vm-mm I

. ~.

A PLANT SYSTEMS

- SURVEILLANCE REQUIREMENTS c.

At least once per 18 months by:

1.

Performing a system functional test,which includes simulated automatic actuation and verifying that each automatic valve in the flow path actuates to its correct position, but may exclude actual injection of coolant into the reactor vessel.

2.

Verifying that the system is capable of providing a flow of greater than or equal to 600 gpm to the reactor vessel when steam is supplied to the turbine at a pressure of 150 1 15 psig using the test flow path.

3.

Performing a CHANNEL CALIBRATION of the discharge line " keep filled" pressure alarm instrumentation and verifying the low pressure setpoint to be > 62 psig.

l d.

By demonstrating MCC-121y and the 250-volt battery ** and charger **

OPERABLE:

1.

At least once per 7 days by verifying that:

a)

MCC-121y is energized, and has correct breaker alignment, indicated power availability from the charger and battery, and voltage on the panel with an overall voltage of greater than or equal to 250 volts.

b)

The electrolyte level of each pilot cell is above the plates, l

c)

The pilot cell specific gravity, corrected to 77 F, is greater than or equal to 1.200, and d)

The overall battery voltage is greater than or equal to 250 volts.

2.

At least once per 92 days by verifying that:

a)

The voltage of each connected battery is greater than or equal to 250 volts under float charge and has not decreased more than 12 volts from the value observed during the original test, b)

The specific gravity, corrected to 77 F, of each connected cell is greater than or equal to 1.195 and has not decreased more than 0.05 from the value observed during the previous test, and c)

The electrolyte level of each connected cell is above the plates.

3.

At least once per 18 months by verifying that:

a)

The battery shows no visual indication of physical damage or abnormal deterioration, and b)

Battery terminal connections are clean, tight, free of corrosion and coated with anti-corrosion material.

j

  • The provisions of Specification 4.0.4 are not applicably provi-ded the

. surveillance is performed within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after reactor stean pressure is 3

adequate to perform the tests.

    • The Unit 2 RCIC system battery and charger may be in service to supply Unit 1 RCIC system prSvided that they are cemonstrated OPERABLE per Unit 1 T( Snical Specifications.

This footnote shall be deleted upon issuance of an Operating license for Unit 2.

i LA SALLE - UNIT 1 3/4 7-8 Amendment 5 e-w-c.--

.,-,w._....-,-m-.~..

-,_.--+e r, - -.,.,, - -.

.----,-o.

-w e

3/4.7 PLANT SYSTEMS BASES 3/4.7.1 CORE STANDBY COOLING SYSTEM - EQUIPMENT COOLING WATER SYSTEMS The OPERABILITY of the core standby cooling system - equipment cooling water systems and the ultimate heat sink ensure that sufficient cooling capacity is available for continued operation of safety-related equipment during normal and accident conditions.

The redundant cooling capacity of these systems, assuming a single failure, is consistent with the assumptions used in the accident conditions within acceptable limits.

3/4.7.2 CONTROL ROOM AND AUXILIARY ELECTPIC EQUIPMENT ROOM EMERGENCY FILTRATION SYSTEM The OPERABILITY of the control room and auxiliary electric equipment room emergency filtration system ensures that the rooms will remain habitable for operations personnel during and following all design basis accident conditions.

The'0PERABILITY o.f this system in conjunction with room design I ovisions is based on limiting the radiation exposure to personnel occupying the rooms to 5 rem or less whole body, or its equivalent.

This limitation is consistent with the requirements of General Design Criteria 19 of Appendix "A",

10 CFR Part 50.

Cumulative operation of the system with the heaters OPERABLE for 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> over a 31 day period is sufficient to reduce the buildup of moisture on the adsorbers and HEPA filters.

3/4.7.3 REACTOR CORE ISOLATION COOLING SYSTEM The reactor core isolation cooling (RCIC) system is provided to assure adequate core cooling in the event of reactor isolation from its primary heat sink and the loss of feedwater flow to the reactor vessel without requiring actuation of any of the Emergency Core Cooling System equipment.

The RCIC system is conservatively required to be OPERABLE whenever reactor pressure exceeds 150 psig even though the LPCI mode of the the residual heat removal (RHR) system provides adequate core cooling up to 350 psig.

The RCIC system specifications are applicable during OPERATIONAL CONDITIONS 1, 2 and 3 when reactor vessel pressure exceeds 150 psig because RCIC is the primary non-ECCS source of core cooling when the reactor is pressurized.

With the RCIC system inoperable, adequate core cooling is assured by the OPERABILITY of the HPCS system and justifies thu specified 14 day out-of-service period.

i The surveillance requirements provide adequate assurance that RCICS will be OPERABLE when required.

Although all active components are testable'and full flow can be demonstrated by recirculation during reactor operation, a complete functional test requires reactor shutdown.

Initial startup test program data may be used to determine equivalent turbine / pump capabilities between test flow path and the vessel injection flow path.

The pump discharge l

piping is maintained full to prevent water hammer damage and to start cooling at the earliest possible moment.

LA SALLE - UNIT 1 B 3/4 7-1 Amendment 5

Table 4.6.1.5-2 ( ontinued)

TENDON LIFT-OFF FORCE HOOP TENDONS First Year

  • Tendon Number Ends Maximum (kips)

Minimum (kips)

Y1 Y2 48AC A

N/A 647.00 N/A 4.500 B

N/A 647.00 N/A 4.500 3BA A

N/A 656.46 N/A 4.226 8

N/A 656.46 N/A 4.226 12BA A

N/A 637.48 N/A 6.173 B

N/A 637.48 N/A 6.173 21CB A

N/A 637.48 N/A 6.173 8

N/A 637.48 N/A 6.173 23BA A

N/A 629.71 N/A 6.173 B

N/A 629.71 N/A 6.173 38CB A

N/A 631.76 N/A 5.437 B

N/A 631.76 N/A 5.437 49AC A

N/A 647.00 N/A 4.500 B

N/A 647.00 N/A 4.500 68B A

N/A 655.39 N/A 4.332 B

N/A 655.39 N/A 4.332 4BA A

N/A 651.16 N/A 4.226 B

N/A 651.16 N/A 4.226 41CB A

N/A 644.51 N/A 4.975 B

N/A 644.51 N/A 4.975 50AC A

N/A 650.35 N/A 4.500 B

N/A 650.35 N/A 4.500 50CB A

N/A 650.35 N/A 4.500 B

N/A 650.35 N/A 4.500 53BA A

N/A 649.82 N/A 4.538 8

N/A 649.82 N/A 4.538 57AC A

N/A 650.14 N/A 4.862 8

N/A 650.14 N/A 4.852 39CB A

N/A 644.69 N/A 5.437 B

N/A 644.69 N/A 5.437 49BA A

N/A 647.00 N/A 4.500 B

N/A 647.00 N/A 4.500 710 A

N/A 645.20 N/A 4.332 B

N/A 645.20 N/A 4.332 1BA A

N/A 655.82 N/A 3.914 B

N/A 655.82 N/A 3.914 47AC A-N/A 644.51 N/A 4.975 B

N/A 644.51 N/A 4.975 57BA A

N/A 650.18 N/A 4.852 B

N/A 650.18 N/A 4.662 48CB A

N/A 646.48 N/A 4.507 B

N/A 646.48 N/A 4.537 51AC A

N/A 653.75 N/A 4.507 B

N/A 653.75 N/A 4.537

  • First Inspection LA SALLE - UNIT 1 3/4 6-12a Amendment 1

Table 3.7.9-2 (Continued)

~

Snubber System snubber installed on Snubber System snubber installed No.

location and elev.

No.

on location and elev.

HP02-15245 HP Containment 690 LC01-1057S LC Auxiliary 681 HP02-18005 HP

-Reactor 686 LC01-10585 LC Auxiliary 681 HP08-10095 HP Reactor 704 LC01-10595 LC Auxiliary 706 HP08-1024S HP Reactor 699 LC01-10655 LC Auxiliary 722 HP08-10265 HP Reactor 700 LC01-1066S LC Auxiliary 706 HP08-1028S HP Reactor 699 LC01-10685 LC Auxiliary 722 HP08-1029S HP Containment 703 LC01-10695 LC Auxiliary 722 HP09-10135 HP Reactor 688 LC01-10705 LC Auxiliary 721 HP09-1036S HP Reactor 693 LC01-10895 LC Auxiliary 732 HP14-10035 HP Reactor 681 LC01-10965 LC Auxiliary' 733 HP22-10035 HP Reactor 768 LC01-11065 LC Auxiliary 731 HP75-1003S HP

_ Diesel Generator 735 LC01-11205 LC Auxiliary 732 HP75-1005S HP Diesel Generator

/46 LC01-1121S LC Auxiliary 732 LC01-1002S LC Auxiliary 707 LC01-11235 LC Auxiliary 732 LC01-1003S_

LC Auxiliary 707 LC01-1126S LC Auxiliary 73'2 LC01-1004S LC Auxiliary 706 LC01-18075 LC Reactor 680 i

LC01-10055 LC

-Auxiliary 706 LC01-1808S LC Reactor 680 LC01-10075 LC Auxiliary 707 LC01-18095 LC Reactor 680 LC01-1008S LC Auxiliary 707 LC01-18105 LC Reactor 680 LC01-10135 LC Auxiliary 706 LC03-1817S LC Reactor 680 LC01-1014S LC Auxiliary 706 LC03-18205 LC Reactor 680 LC01-10155 LC Auxiliary 690 LC03-18235 LC Reactor 680 LC01-10195 LC Auxiliary 706 LC03-1826S LC Reactor 680 LC01-1021S LC Auxiliary 681-LC09-1001S LC Reactor 681 LC01-10225 LC Auxiliary 706 LC09-10135 LC Auxiliary 679 LC09-10185 LC Auxiliary 681 M500-10155 MS Containment 780 LC09-10315 LC Auxiliary 702 MS00-10165 MS Containment 780 LC09-10365 LC Auxiliary 702 M500-1017S MS Containment 775 LC09-10495 LC Auxiliary 681 M500-10195 MS Containment 763 LC09-10505 LC Auxiliary 681 MS00-10205 MS Containment 743

'LC09-10525 LC Auxiliary 681 M500-10215 MS Containment' 743 LC09 ~0535 LC Auxiliary 737 MS00-1022S-MS Containment 743 LP01-10145 LP Reactor 681 MS00-1023S MS Containment 769 LP02-1013S LP Containment 778 MS00-10245 MS Containment 786 LP02-10155 LP Containment 774 M500-1025S MS Containment 787 LP02-10165 LP Containment 774 MS00-10265 MS Containment 780 LP02-10175 LP Containment 774 MS00-1029S MS Containment 743 LP02-10185 LP Containment 774 MS00-10305 MS Containment 772 LP02-10195 LP Containment

/74 M500-10315 MS Containment 785 LP02-1020S LP Reactor 777 MS00-10325 MS Containment 790 LP02-10255 LP Reactor 703 MS00-10335 MS Containment 790

.LP02-10545 LP Reactor 777 MS00-1034S MS Containment 780 LP02-10555 LP Reactor 777 M500-10385 MS Containment 743 LP02-10575 LP Reactor 777 MS00-1039S MS Containment 743 LP02-10595.

LP Reactor 777 MS00-1040S MS Containment 772 LP02-1062S LP Reactor 689 M500-10415 MS Containment 786 LP02-10675 LP Containment 788 MS00-10425 MS Containment 790 LP19-1011S LP Reactor 763 M500-10435 MS Containment 790 LP20-10255 LP Reactor 733 M500-10445 MS Containment 780

' LA'SALLE - UNIT 1 3/4 7-33 Amendment 1 4

Table 3.7.9-2 (Continued)

Snubber System snubber installed on Snubber System snubber installed No.

location and elev.

No.

on location and elev.

MSO4-1245S '

MS Containment 780 MSO4-12985 MS Containment 761 MSO4-12465 MS Containment 779 MSO4-12995

~ MS Containment 770 MSO4-12485 MS Containment 752 M504-13005 MS Containment 772 MSO4-12495 MS Containment 752 MSO4-1301S MS Containment 772 MSO4-1250S MS Containment 771 M504-1302S MS Containment 781 M504-1251S MS Containment 771 MS04-1304S MS Containment 781 M504-12525 MS Containment 771 M504-13055 MS Containment 774 M504-12535 MS Containment 778 MSO4-1307S MS Containment 771 MSO4-1256S MS Containment 766 MSO4-13085 MS Containment 773 MS04-12585 MS Containment 761 MSO4-13205 MS Containment 746 MS04-12595 MS Containment 780 MSO4-1321S MS Containment 768 MSO4-12615 MS Containment 774 MSO4-1322S MS Containment 766 MSO4-1262S MS Containment 748 MSO4-13235 MS Containment 766 MS04-12655 MS Containment 745 M504-1324S MS Containment 749 MSO4-12665 MS Containment 764 MS04-13255 MS Containment 766 M504-1267S MS Containment 767 MS04-13285 MS Containment 751 MS04-1269S MS Containment 790 MSO4-13295 MS Containment 772 MSO4-1270S MS Containment 781 MSO4-1330S MS Containment 772 MSO4-1271S MS Containment 747 MSO4-1331S MS Containment 774 MS04-1272S MS Containment 747 MSO4-1332S MS Containment 745 MSO4-12745 MS Containment 769 M504-1333S MS Containment 748 MSO4-1275S MS Containment 769 MSO4-1334S MS Containment 774 MS04-1276S MS Containment 772

!!SO4-1337S MS Containment 749 MSO4-12775 MS Containment 773 MSO4-1341S MS Containment 748 MSO4-12785 MS Containment 773 M504-1344S MS Containment 782 MSO4-12795 MS Containment 780 MSO4-13455 MS Containment 743 MS04-12815 MS Containment 773 MSO4-13465 MS Containment 743 MSO4-12825 MS Containment 753 MSO4-13475 MS Containment 757 MSO4-1283S MS Containment 751 MSO4-13495 MS Containment 742 MS04-12885 MS Containment 770 MS04-1350S MS Containment 759 MS04-12895 MS Containment 773 MS04-1351S MS Containment 758 MSO4-12905 MS Containment 772 MSO4-13535 MS Containment 749 MSO4-12915 MS Containment 780 MS04-13545 MS Containment 749 M504-12935 MS Containment 781 M504-13555 MS Containment 759 MS04-12945 MS Containment 744 MSO4-13565 MS Containment 766 MS04-1358S MS Containment 775 MSO4-15465 MS Containment 760 MSO4-13595 MS i.ontainment 780 MSO4-1549S MS Containment 760 MSO4-13625 MS Containment 751 MSO4-15505 MS Containment 760 MS04-13635 MS Containment 759 MSO4-1551S MS Containment 781 M504-13645 MS Containment 759 MSO4-15535 MS Containment 748 MSO4-13665 MS Containment 757 M504-16835 MS Containment 769 MS04-13675 MS Containment 775 M504-17055 MS Containment 751 MS04-13685 MS Containment 743 MS05-1002S MS Containment 810 MSO4-13695 MS Containment 779 MS05-1004S MS Containment 804 MSO4-1371$

MS Containment 783 MS05-10055 MS Containment 804 MSO4-13725 fiS Containment 749 MS05-10085 MS Containment 804 MSO4-13735 MS Containment 766 MS05-10105 MS Containment 804 l

M504-13765 MS

. Containment 745

!!S06-1006S MS Containment 787 MSO4-13785 MS Containment 761 MS06-1016S MS Containment 776 i

M504-13795 MS Containment 760 MS06-1017S MS Containment 779 LA SALLE - UNIT 1 3/4 7-35 Amendment 1

~

Table 3.7.9-2 (Continued)

Snubber System snubber installed on Snubber System snubber installed No.

location and elev.

No.

on location and elev.

MSO4-1384S MS Containment 749 MS10-1002S MS Containment 761 MSO4-13905 MS Containment 783 MS10-1007S MS Containment 761 MS04-13915 MS Containment 783 MS10-1013S MS Containment 759 MSO4-13925 MS Containment 783 MS14-1030S MS Containment 738 MSO4-13935 MS Containment 783 MS14-10315 MS Containment ~

738 MSO4-1394S MS Containment 751 MS14-1034S MS Containment 738 MS04-13955 MS Containment 751 MS14-1037S MS Containment 739 MS04-13965 MS Containment 747 MS14-1038S MS Containmer.t 738 MSO4-13975 MS Containment 744 MS14-10395 MS Contain:nent 739 MSO4-13985 MS Containment 758 M514-10445 MS Containment 739 MSO4-13995 MS Containment 760 MS14-1047S MS Containment 740 MSO4-1502S MS Containment 760 MS14-1048S MS Containment 741 MSO4-1503S MS Containment 763 MS14-10505 MS Containment 739 MS04-1504S MS Containment 771 MS14-10515 MS Containment 740 M504-15055 MS Containment 770 MS14-1052S MS Containment 741 MSO4-1506S MS Containment 758 MS14-10545 MS Containment 741 MSO4-15085 MS Containment 748 MS14-1055S MS Containment 741 MSO4-15095 MS Containment 756 MS14-1056S MS Containment 741 MSO4-15105 MS Containment 749 MS14-10585 MS Containment 741 M504-15115 MS Containment 760 MS14-1059S MS Containment 741 MS04-1513S MS Containment 761 M514-1063S MS Containment 739 MS14-10665 MS Containment 741 NB15-10025 NB Containment 830 NB15-10055-i4B Containment 828 MS25-1023S MS Auxiliary 689 NB15-10085 NB Containment 827 MS25-10615 MS Auxiliary 689 NB16-10025 NB Containment 810 MS88-1005$

MS Containment 787 NB16-10055 NB Containment 810

.MS88-10065 MS Containment 787 NB16-1006S NB Containment 809 MSB8-10115 MS Reactor 740 NB23-10035 f4B Containment 808 MSB8-10125 MS Reactor 740 NB25-10025 NB Containment 808 MSB8-10135 MS Reactor 740 PC01-10145 PC P.eactor 741 MSB8-1015S MS Reactor 740 PC01-10155 PC Reactor 741 MSB8-10205 MS Reactor 740 PC01-10165 PC Reactor 741 MSC6-10035 MS Containment 761 PC01-10175 PC Reactor 741 MSC6-10045 MS Reactor 761 PC01-10195 PC Reactor 747 MSC6-10055 MS Containment 760 PC01-10205 PC Reactor 747 MSC6-10065 MS Reactor 761 PC01-18005 PC Reactor 751 MSC6-10095 MS Containment 761 RG10-00145 RG Auxiliary 795 MSC6-10135 MS Containment 760 RG21-00125 RG Auxiliary 797 l

~MSC6-10155 MS Containment 760 Rh01-1005S RH Reactor 675 l

MSC6-10165 MS Containment 761 RH01-1006S RH Reactor 675 MSC6-10185 MS Containment 760 RH01-10085 RH Reactor 681 MSC6-1G215 MS Containment 760 RH01-10135 RH Reactor 681 MSC6-1024S MS Containment 761 RH01-10175 RH Reactor 681 MSD1-10015 MS Containment 787 RH01-10185 RH Reactor 681 MSF9-2,0025 MS-Containment 785 RH01-10255 RH Reactor 678 MSF9-1004E MS Containment 784 RH02-10305 RH Reactor 705 MSF9-1006S MS Containment 787 RH02-10125 RH Reactor 6C6 1

~ LA SALLE - UNIT 1 3/4 7 Amendment 1

Table 3.7.9-2 (Continued)

Snubber System snubber installed on Snubber System snubber installed No.

location and elev.

No.

on location and elev.

MSF9-1007S MS Containment 788 RH02-1017S RH Reactor 732 NB11-10035 NB Containment 808 RH02-10185 RH Reactor 686 NB13-10015 NB Containment 832 RH02-10195 RH Reactor 686 NB13-10025 NB Containment 832 RH02-10245 RH Reactor 735 NB13-10045 NB Containment 829 RH02-10255 RH Reactor 695 NB13-10065 NB Containment 828 RH02-1026S RH Reactor 703 NB13-1025S NB Containment 813 RH02-10275 RH Reactor 695 NB13-1027S NB Containment 811 RH02-1043S RH Reactor 735 NB13-10285 NB Containment 814 RH02-10475 RH Reactor 725 NB13-1031S NB Containment 811 RH02-10485 RH Reactor 722 RH02-1051S RH Reactor 732 RH03-1517S RH Containment 741 RH02-1052S RH Reactor 712 RH03-15245 RH Reactor 733 RH02-1056S RH Reactor 710 RH03-1525S RH Reactor 736 RH02-1057S RH Reactor 696 RH03-15265 RH Reactor 736 RH02-10585 RH Reactor 686 RH03-15275 RH Reactor 700 RH02-10605 RH Reactor 710 RH03-15285 RH Reactor 730 RH02-10625 RH Reactor 715 RH03-1530S RH Reactor 736 RH02-1063S RH Reactor 727 RH03-15325 RH Reactor 736 RH02-1064S RH Reactor 696 RH03-1533S RH Reactor 715 RH02-10G55 RH Reactor 685 RH03-15345 RH Reactor 736 RH02-10675 RH Reactor 683 RH03-15375 RH Rea'ctor 734 RH03-10345 RH Reactor 729 RH03-15405 RH Reactor 718 RH03-10355 RH Reactor 733 RH03-15415 RH Reactor 700 RH03-1036S RH Reactor 719 RH03-1544S RH Containment 738 RH03-1037S RH Reactor 717 RH04-10205 RH Reactor 682 RH03-1038S RH Reactor 718 RH04-10215 RH Reactor 681 RH03-10445 RH Reactor 734 RH04-10225 RH Reactor 700 RH03-1046S RH Reactor 703 RH04-10235 RH Reactor 703 RH03-10475 RH Reactor 736 RH04-10245 RH Reactor 703 RH03-10495 RH Reactor 700 RH04-1025S RH Reactor 703-

'RH03-10515 RH Reactor 729 RH04-10275 RH Reactor 703 RH03-15005 RH Containment 738 RH04-1028S RH Reactor 703 RH03-1502S RH Containment 738 RH04-10295 RH Reactor 703 RH03-1503S RH Containment 738 RH04-10315 RH Reactor 703 RH03-1504S RH Containment 738 RH04-10325 RH Reactor 703 RH03-1505S RH Cont inment 740 RH04-10335 RH Reactor 703 RH03-1506S RH Containment 742 RH04-10355 RH Reactor 700 RH03-15075 RH Containment 738 RH04-10365 RH Reactor 692 RH03-15085 RH Containment 738 RH04-10385 RH Reactor 688 RH03-15095 RH Containment 738 RH04-10395 RH Reactor 688 RH03-15115 RH Containment 738 RH04-10405 RH Reactor 688

-RH03-1512S RH-Containment 738 RH04-10445 RH Reactor 682 RH03-15135 RH Containment 738 RH04-10455 RH Reactor 682 RH03-1514S RH Containment 738 RH04-10465 RH Reactor 688 RH03-15155 RH Containment 741 RH04-10515 RH Reactor 682 RH03-15165 RH Containment 741 RH04-14165 RH Containment 738 RH04-14185 RH Containment 738 RH12-10715 RH Reactor 688 RH04-14205 RH

, Containment 738 RH12-10725 RH Reactor 697 RH04-15005 RH Containment 738 RH12-10775 RH Reactor 6S2 LA SALLE - UNIT 1 3/4 7-37 Amendment 1

l Table 3.7.9-2 (Continued)

Snubber System snubber installed on Snubber System snubber installed No.

location and elev.

No.

on location and elev.

RH40-1560S RH Containment 794 RH53-15745 RH Reactor 771 RH40-1561S RH Containment 799 RH53-15755 RH Reactor 771 RH40-15725 RH Reactor 734 RH56-1003S RH Reactor 688 RH40-1573S RH Reactor 728 RH56-10075 RH Reactor 688 RH41-10915 RH Reactor 708 RH59-1030S RH Reactor 762 RH42-1032S RH Reactor 705 RH59-1031S RH Reactor 762 RH42-1033S RH Reactor 706 RH59-10485 RH Reactor 758 RH42-1037S RH Reactor 735 RH59-10495 RH Reactor 738 RH59-10525 RH Reactor 758 RIO1-10725 RI Reactor 702 RH59-10565 RH Reactor 754 RIO1-10735 RI Reactor 701 RH82-1030S RH Reactor 708 RI01-1074S RI Reactor 701 RH82-1037S RH Reactor 687 RI01-10765 RI Reactor 692 RH82-10385 RH Reactor 686 RIO1-10775 RI Reactor 693 RH82-10405 RH Reactor 686 RI01-10805 RI Reactor 685 RH82-10415 RH Reactor 687 RI01-10815 RI Reactor 685 RH82-10465 RH Reactor 695 RIO1-1083S RI Reactor 676 RH82-10685 RH Auxiliary 698 RI01-10845 RI Reactor 678 RH82-10745 RH Auxiliary 698 RI01-10855 RI Reactor 678 RH83-10115 RH Reactor 689 RIO1-1088S RI Reactor 679 RH83-1014S RH Reactor 689 RI01-10895 RI Reactor 683 RH83-10155 RH Reactor 689 RIO1-10905 RI Reactor 683 RH83-10165 RH Reactor 684 RIO1-10915 RI.

Reactor 683 RH83-1017S RH Reactor 684 RIO1-10925 RI Reactor 677

.RH83-1018S RH Reactor 684 RIO1-10935 RI Reactor 678 RH83-10375 RH Reactor 689 RIO1-11015 RI Containment 718 RHA6-1003S RH Reactor 715 RIO1-1102S RI Containment 718 RHB4-1002S RH Containment 738 RI01-11035 RI Containment 750 RHB4-10055 RH Containment 738 RIO1-11065 RI Containment 776 I

RHB4-10075 RH Containment 742 RIO1-11085 RI Containment 779 RHB4-10085 RH Containment 742 RIO2-10075 RI Reactor 680 RHB4-1011S RH Containment 745 RIO2-10095 RI.

Reactor 687 RIO1-10065 RI Containment 753 RIO9-1005S RI Containment 742 l

RIO1-10075 RI Containment 771 RIO9-10075 RI Containment 742 RI01-1008S RI Containment 769 RIO9-10085 RI Containment 747 RIO1-10095 RI Containment 769 RIO9-10095 RI Containment 747 RIO1-10105 RI Containment 775 RIO9-1011S RI Containment 743 RIO1-1011S RI Containment 775 RIO9-10165 RI Containment 743 RIO1-10125 RI Containment 774 RIO9-10215 RI Containment 743 RIO1-10635 RI Reactor 743 RIO9-10245 RI Containment 747 RIO1-10645 RI Reactor 743 RIO9-10255 RI Containment 746 l

RI01-10655 RI Reactor 744 RIO9-10265 RI Containment 747 RIO1-10675 RI Reactor 740 RIO9-10275 RI Containment 743 RI01-10695 RI Reactor 736 RI16-10165 RI Reactor 688 RIO1-10705 RI Reactor 736 RI16-10225 RI Reactor 683 RI16-10235.

RI' Reactor 683 RI41-10675 RI Reactor 703 RI16-10255 RI Reactor 687 RI41-10685 RI Reactor 703 RI24-10155 RI Containment 793 RI41-10895 RI Reactor 703 RI24-10165 RI Containment 793 RI41-10925 RI Reactor 711 LA SALLE - UNIT 1 3/4 7-40 Ame'rdnent 1 i

Table 3.7.9-2 (Continued)

Snubber System snubber installed on Snubber System snubber installed No.

location and elev.

No.

on location and elev.

RR00-10575 RR Containment 765 SC02-1027S SC Reactor 781 RR00-10585 RR Containment 739 SC02-10365 SC Containment 774 RR00-10595 RR Containment 743 SC02-10385 SC Containment

'770 RR00-1060S RR Containment 746 SC02-10475 SC Containment 757 RR00-10615 RR Containment 746 SC02-1055S SC Containment 750 RR00-10625 RR Containment 748 VG01-0001S VG Reactor 831 RR01-10325 RR Containment 743 VG01-0005S VG Reactor 831 RR07-14325 RR Containment 738 VG01-00065 VG Reactor 831 RR17-1001S RR Containment 738 VG01-00085 VG Reactor 831 RR17-1002S RR Containment 737 VG01-0010S VG Reactor 831 RR17-1003S RR Containment 737 VG02-10045 VG Reactor 794 RR17-1004S RR Containment 737 VG02-10055 VG Reactor 794 RR17-1005S RR Containment 737 VG02-18005 VG Reactor 802 RR17-1006S RR Containment 737 VG04-1003S VG Reactor 821 RR17-1007S RR Containment 737 VG04-1005S VG Reactor 809 RR17-1008S RR Containment 737 VG04-10115 VG Reactor 794 RR28.1007S RR Containment.

756 VG04-10145 VG Reactor 794 RR28-10125.

RR Containment 750 VG04-10155 VG Reactor 798 RR28-10155 RR Containment 741 VG04-10195 VG Reactor 798 VQ02-10355 VQ Reactor 805 LP-25-H04S LP VQ02-10405 VQ Reactor 810 N.P. 30A RR-59 VQ05-10015 VQ Reactor 733 RR68-H-4 RR VQ05-10095 VQ Reactor 738 RR68-H-6 RR N.P. 83 RR-59 N.P. 85 RR-59 RR69-H-4 RR N.P. 164 RR-59 FHP1204-H02 HP N.P. 170 RR-59 FHP1204-H03 HP N.P. 175 RR-59 FHP1204-H02 HP N.P. 180 RR-59

'FHP1204-H03 HP N.P. 240 RR-59 N.P. 28B MS-51A HG-08-H035 HG N.P. 38 MS-51A HG-08-H085 HG N.P. 41 MS-51A HG-08-H07S HG

'I.P.

48A MS-51A N.P. 114 HG-61 F P. 296B MS-51A N.P. 115 HG-61

  • .P.

336B MS-51A N.P. 116 HG-61 N.P. 376B MS-51A HG21-H04 HG N.P. B55 MS-51A FRH1213-H15 RH N.P. C43 MS-51A FRH1213-H14 RH NB-125-H075 RH FRH1213-H12 RH N.P. 465 VG-03 FRH1213-H11 RH N.P. 475-X VG-03 FRH1213-H09 RH N.P. 475-Z VG-03 FRH1213-H07 RH N.P. 30B RH-75A FRH1213-H08 RH.

N.P. 30A RH-76 FRH1213-H06 RH N.P. 30B RH-76 FRH1213-H03 RH N.P. 135B RH-76,

FRH1213-H02 RH N.P. 112 HG-61 FRH1213-H01 RH LA SALLE - UNIT 1 3/4 7-42 Amendment 1

Table 3.7.9-2 (Continued)

Snubber System snubber installed on Snubber System snubber installed No.

location and elev.

No.

on location and elev.

HP-12-H02S HP FRH1213-H18 Ri1 HP-12-H045 HP FRHI209-H03 RH N.P. 125 RR-59 FRH1209-H04 RH N.P. 135 RR-59 FRH1209-H05 RH HG-06-H125 HG fi.P. 116 RH-20 FRH1209-H06 RH N.P. 52 RH-68 FRH1231-H02 RI N.P. 63 RH-68 FRH1207-H02 RH N.P. 95 RH-68 FRH1207-H05 RH RH52-H07 RH FRI1210-H07 RI RH52-H08 RH FRI1209-H05 RI RH52-H09 RH FRH1232-H10 RI RH52-H06 RH FRH1232-H08 RI RH52-H05 RH FRH1232-H06 RI RH52-H02 RH N.P. 23 LC-71 RH52-H03 RH N.P. A34 LC-71 N.P. 133 RH-68 FRH1206-H21 RH FR;11211-H01 RH FRH1206-H16 RH FRH1211-H04 P,H N.P. 303 LC-62 FRH1211-H03 RH N.P. 18-X LC-63 FRH42-1037 RH N.P. 18-Z LC-63 H-4RH-87 RH N.P. 23 LC-64 H-2RH-88 RH N.i 23-Z LC-65 N.P. 120 RH-69 N.P. 23-X LC-65 N.P. 135 RH-69 FRI1207-H01 RI FRH1214-H-125 CS 1RIO7B-2-1-H08 RI FRH1230-H07 RH 1PIO78-2-1-H06 RI FRH1230-H06 RH 1RIO78-2-1-H05 RI FRH1230-H05 RH 1RIO78-2-1-H16 RI FRH1230-H03 RH N.P. 53 RH-21 FRH1230-H02 RH N.P. 90 RH-21 FRH1230-H01 RH N. P. 100 RH-21 FRH1206-H03 RH N.P. 125 RH-21 FRH123?-H05 RI MS-52-H065 MS FRH1233-H04 RI MS-53-H065 MS FRH42-1031 RH f15-53-H055 MS FRH42-1032 RH MS-50-H025 MS FRH42-1033 RH MS-50-H045 MS N.P. 135 RH-16 MS-51-H055 MS FRH1231-H09 RI RT-33-H085 MS FRH1231-H06 RI RT-33-H095 MS FRH1231-H04 RI RT-33-H105 MS RH25-H01 RH N.P. 50 RH-C3 RH25-H02 RH N.P. 52 RH-C3 RH25-H04 RH M-1302-22-109 RH RH25-H03 RH M-1302-22-110 RH RH25-H05 RH M-1302-22-112 RH RH25-H06 RH f1-1302-22-113 RH HG-04-H045 HG fi-1302-23-96 MS N. P. 117 HG-61 N.P. 60A RH-C3

' LA SALLE - UNIT 1 3/4 7-43 Amendment 1

~

Table 3.7.9-2 (Continued)

Snubber System snubber installed on Snubber System snubber installed No.

location and elev.

No.

on location and elev.

M-1302-22-83 RR M-1302-22-33 RR M-1302-22-127 RR M-1302-24-110 RR M-1302-24-111 RR M-1302-24-106 RR M-1302-24-107-RR M-1302-24-103 RR M-1302-21-183 MS M-1302-21-181 MS N.P. 85B MS-C1 N.P. 65-Z MS-C2 N.P. 65-Y MS-C2 M-1302-21-162 MS M-1302-21-163 MS M-1302-21-74 MS M-1302-21-189 MS HP75-20095 HP Diesel Generator 749 2HG-24-H02 2HG-62 HP75-20145 HP Diesel Generator 735 2HG-16-H01 2HG-62

-HP75-2017S HP Diesel Generator 747 RH-27H-H035 2HG-61 HP75-28005 HP Diesel Generator 743 RH-27H-H06S 2HG-61 RH83-2006S RH Reactor 684 2HG-4H-H10S 2HG-61 RH83-2007S RH Reactor 689 2HG-15H-H03S 2HG-61 RH83-2009S RH Reactor 684 2HG-15-H05S 2HG-61 RH83-2012S RH Reactor 689 2HG-15H-H01S 2HG-61 RH83-2013S RH Reactor 684 2DG-66-H03 2CS-75 RH83-2016S RH Reactor 689 2HG23-H06 2HG-70 SC02-29675 SC Reactor 782 2HG23-H09 2HG-70 VG01-00155 VG Reactor 831 2VQ-10-H02 2VG-03 VG01-00165 VG Reactor 831 2VQ-10-H04 2VG-03 VG01-20195 VG Reactor 830 2VQ-11-H01 2VG-03 VG01-20215 VG Reactor 803 2VQ-11-H03 2VG-03 VG02-0012S VG Reactor 831 2VQ-11-H06 2VG-03 VG02-2019S VG Reactor 803 2VQ-11-H04 2VG-03 VG02-20215 VG Reactor 831 VG02-20225 VG Reactor 794 VG02-2023$

VG Reactor 826 VG02-20245 VG Reactor 831 VG03-2001S VG Reactor 794 VQ04-20195 VQ Reactor 738 VQ04-2020S VQ Reactor 733 VQ05-20235 VQ-Reactor 762 VQ05-20245 VQ Reactor 762 VQ05-20255 VQ Reactor 787 VQ05-20265 VQ Reactor 732 VQ05-2031S VQ Reactor 733 VQ04-28005 VQ Reactor 733 VQ06-20025 VQ

, Auxiliary 810 LA SALLE - UNIT 1 3/4 7-45 Amendment 1

. - -