ML20069D478

From kanterella
Jump to navigation Jump to search
First Interim Deficiency Rept Re Johnson Machine Works Welds on Auxiliary Feedwater Pump Doors.Initially Reported on 830210.Util Analyzing Welds to Determine Performance During Secondary Safety Function.Also Reportable Per Part 21
ML20069D478
Person / Time
Site: Bellefonte  
Issue date: 03/09/1983
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
REF-PT21-83 10CFR-050.55E, 10CFR-50.55E, NCR-2221, NUDOCS 8303180383
Download: ML20069D478 (2)


Text

.

g-.

N'g

  • -er TENNESSEE VALLEY AUTHORITY CH ATTANOOGA. TEN k G795iGION P 400 Chestnut Street Toke *E.IIE Ut 95 March 9, 1983 83 MAR 15 AiU. 43 BLRD-50-438/83-20 BLRD-50-439/83-16 U.S. Nuclear Regulatory Cormnission Region II Attn:

Mr. James P. O'Reilly, Regional Administrator 101 Marietta Street,. Suite 2900 Atlanta, Georgia 30303

Dear Mr. O'Reilly:

BELLEFONTE NUCLEAR PLANT UNITS 1 AND 2 - DEFICIENT JOHNSON MACHINE WORKS WELDS ON AFW PUMP ROOM DOORS - BLRD-50-438/83-20, BLRD-50-439/83 FIRST INTERIM REPORT The subject deficiency was initially reported to NRC-0IE Inspector Linda Watson on February 10, 1983 in accordance with 10 CFR 50.55(e) as NCR 2221. Enclosed is our first interim report. We expect to submit our next report by July 13, 1983 We consider 10 CFR Part 21 applicable to this deficiency.

If you have any questions concerning this matter, please get in touch with R. H. Shell at FTS 858-2688.

Very truly yours, TENNESSEE VALLEY AUTHORITY Q^81.YlaJ L. M. Mills,IManager l

Nuclear Licensing l

Enclosure cc:

Mr. Richard C. DeYoung, Director (Enclosure)

Office of Inspection and Enforcement l

U.S. Nuclear Regulatory Commission l

Washington, D.C.

20555 I

l i

l i

OFFlWOW 8303180383 830309 PDR ADOCK 05000438 y

ff S

PDR gg

/

An Equal Opportunity Employer

ENCLOSURE BELLEFONTE NUCLEAR PLANT UNITS 1 AND 2 DEFICIENT JOHNSON MACHINE WORKS WELDS ON AFW PUMP ROOM DOORS NCR 2221 BLRD-50-438/83-20, BLRD-50-439/83-16 10 CFR 50.55(e)

FIRST INTERIM REPORT l

j Description of Deficiency The auxiliary feedwater (AFW) pump room personnel access doors exhibit weld quality not in conformance with American Welding Society (AWS) D1.1 acceptance criteria. This is contrary to the requirements stipulated in TVA's Procurement Specification 3294, Section 23 The documented weld deficiencies include undersized, overlapped, and undercut welds, craters and slag. Undersize welds are present in a high proportion of the assemblies. The doors were fabricated by Johnson Machine Works, Chariton, Iowa.

Nonreportable nonconformance report (NCR) 1463 and reportable NCRs 1630 and 1929 were previously initiated to document similar deficiencies with Johnson Machine Works supplied items. This NCR and NCR 1929 were issued as a result of significant conditions adverse to quality documented on the earlier NCRs and a subsequent investigation to determine if a generic condition adverse to quality with respect to Johnson Machine Works products exists.

Interim Progress TVA is analyzing the subject welds to determine if they will perform their intended secondary safety function in their present condition. TVA will provide an cdditional report upon completion and review of this analysis.

_ _ _ _ _ _ _. _ _. _ - - - - - - -. - -