CharCO C. Jackson Vce Pres' dent Consohdated Edison Company of New York. Inc, lod.an Point Station Broadway & Bleakiey Ave.

Buchanan, NY 10511 Teiephone (914) 737-8116 November 9, 1982 Re:

Indian Point Unit No. 2 Docket No. 50-247 Mr. Ronald C. Haynes, Regional Administrator Region I U.S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, Pennsylvania 19406

Dear Mr. Haynes:

In accordance with the Technical Specifications of Facility Operating License No. DPR-26, the following confirms notification on November 8, 1982 to Mr. Peter Koltay of your office, by Mr. Michael Blatt of Consolidated Edison of a Reportable Occurrence LER 82-045.

This event is the type defined in Technical Specification, Section 6.9.1.7.1.c.

The Cycle 5/6 spent fuel inspection program includes a video examination of fuel assemblies scheduled to be returned to the core for Cycle 6.

As a result of the review of videotapes of fuel assembly F-44, Con Edison was informed by Westinghouse at 3:25 p.m. on November 8 that an upper end plug from one fuel rod was observed to be lodged betwe(~ the upper end plugs of adjacent fuel rods within this assembly. The end spring for the affected fuel rod was visible, extending cut of the top of the rod, indicating that the fuel pellets remained contained inside the rod.

No other significant anomalies were observed for this assembly.

The affected assembly will not be returned to the core for Cycle 6.

Consolidated Edison believes that this report also satisfies the requirements l

of 10 CFR Part 21.

Very truly your /

/

cc:

Mr. William Mcdonald, Director (2 copies)

Office of Management Information and Program Control c/o Distribution Services Branch, DDC, ADM U.S. Nuclear Regulatory Commission Washington, D. C.

20555 Mr. T. Foley, Senior Resident Inspector U.S. Nuclear Regulatory Commission P. O. Box 28 Buchanan, New York 10511 8211230043 821109 PDR ADOCK 05000247 S

PDR

-[6 Y

.. - - - -