ML20065M772

From kanterella
Jump to navigation Jump to search
Submits Results of Radiochemical Analysis of Spiked Samples in Accordance W/Nrc Confirmatory Measurements Program. Radionuclide Concentrations Given for H-3,Sr-89,Sr-90 & Fe-55
ML20065M772
Person / Time
Site: Sequoyah  
Issue date: 12/07/1990
From: Wallace E
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9012110205
Download: ML20065M772 (2)


Text

..

A

=

TENNESSEE VALLEY AUTHORITY 5B Lookout Place Chattanooga, Tennessee 37402-2801 December 7, 1990 U.S. Nucicar Regulatory Commission ATTN Document Control Desk Washington, D.C.

20555 Gentlement In the Matter of

)

Docket Nos. 50-327 Tennessee Valley Authority

)

50-328 SEQUOYAll NUCLEAR PLANT (SQN) - RESULTS OF TVA'S RADI0 CHEMICAL ANALYSIS OF SPIKED SAMPLES IN ACCORDANCE WITil NRC CONFIRMATORY MEASUREMENTS PROGRAM

Reference:

B. A. Wilson's letter to 0. D. Kingsley, Jr., dated October 12, 1990 " Docket Nos. 50-327 and 50-328" Below are the results of the radiochemical analysis performed on the NRC cross-check samples in compliance with SQN's participation in NRC's confirmatory measurements program for 1990.

The samples arrived at the plant cite on October 11, 1990.

The iron and strontium analyses were performed by TVA's vendor laboratory, and the tritium was analyt.ed by SQN's chemistry laboratory.

Radionuclide Concentration (uCi/ml)

Tritium 113 4.10E-5 Strontium 89 Sr89 5.69E-5 Strontium 90 Sr90 2.6PE-6 Iron Fe55 7.43E-5 If you have any questions concerning this submittal, please telephone M. A. Cooper at (615) 863-6422.

Very truly yours.

TENNESSEE VALLEY AUTHORITY Ofm 9012110205 901207 f[NuclearLicensingand E. G. Wallace, Managt-f,DR ADOCK 05000327 PDC Regulatory Affairs

/d cc: See page 2 g;[gg

((

/

.r634 An Equal Opportunity Employer J[d

,a U.S. Nuclear Regulatory Commission December 7, 1990 cc Ms. S. C. Black, Deputy Director Project Directorate II-4 U.S. Nuclear Regulatory Commission One White Flint, North 11555 Rockville Pike Rockville, Maryland 20B52 Mr. J. N. Donohew, Project Manager U.S. Nuclear Regulatory Commission One White Flint, North 11555 Rockville Pike Rockville, Maryland 20852 NRC Resident Inspector Sequoyah Nuclear Plant 2600 Igou Terry Road Soddy Daisy, Tennessee 37379 Mr. B. A. Wilson, Project Cl.ief U.S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323

....