TENNESSEE VALLEY AUTHORITY DOCKET NO. 50-327 SE000YAH NUCLEAR PLANT. UNIT 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 177 License No. DPR-77 1.
The Nuclear Regulatory Commission (the Commission) has found that:
A.
The application for amendment by Tennessee Valley Authority (the licensee) dated January 8, 1993; which was supplemented by submittals dated April 1, May 3, and August 18, 1993; and February 22, 1994, complies with the standards and requirements of the Atomic Energy Act of 1954, as. amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; 8.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.
There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.
The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
9403210089 940315 PDR ADOCK 05000327 P
, 2.
Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment and paragraph 2.C.(2) of Facility Operating License No. DPR-77 is hereby amended to read as follows:
(2) Technical Soecifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No.177, are hereby incorporated in the license.
The licensee shall operate the facility in accordance with the Technical Specifications.
3.
This license amendment is effective as of its date of issuance, to be implemented within 30 days.
FOR E NUCLEAR REGULATORY COMMISSION l
/
c/
W" (
Frederick J. Hebdon, Director Project Directorate II-4 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation
Attachment:
Changes to the Technical Specifications Date of Issuance: March 15,1994 y
aJTACHMENT TO LICENSE AMEN 0 MENT NO. 177 FACILITY OPERATING LICENSE NO. DPR-77 DOCKET NO. 50-327 4
Revise the Appendix A Technical Specifications by removing the page identified below and inserting the enclosed page.
The revised page contains a marginal lines indicating the area of change.
REMOVE
]NSERI 3/4 4-27 3/4 4-27
REACTOR COOLANT SYSTEM 3/4.4.10 STRUCTURAL INTEGRITY ASME CODE CLASS 1. 2 AND 3 COMPONENTS LIMITING CONDITION FOR OPERATION 3.4.10.
The structural integrity of ASME Code Class 1, 2 and 3 components shall be maintained in accordance with Specification 4.4.10.
APPLICABILITY: ALL MODES ACTION:
a.
With the structural integrity of any ASME Code Class 1 component (s) not conforming to the above requirements, restore the structural integrity of the affected component (s) to within its limit or isolate the affected component (s) prior to increasing the Reactor Coolant System temperature more than 50*F above the minimum temperature required by NDT considerations.
b.
With.the structural integrity of any ASME Code Class 2 component (s) not conforming to the above requirements, restore the structural integrity of the affected component (s) to within its limit or isolate the affected component (s) prior to increasing the Reactor Coolant System temperature above 200*F.
c.
With the structural integrity of any ASME Code Class 3 component (s) not conferming to the above requirements, restore the structural integrity of the affected component (s) to within its limit or isolate the affected component (s) from service.
d.
The provisions of Specification 3.0.4 are not applicable.
SURVEILLANCE REQUIREMENTS 4.4.10.
In addition to the requirements of Specification 4.0.5, each Reactor Coolant Pump flywheel shall be inspected per the recommendations of Regulatory Position C 4.b of Regulatory Guide 1.14, Revision 1, August 1975.
SEQUOYAH - UNIT 1 3/4 4-27 Amendment No. 177
Y Olj
[
Ig a l
- '(
S UNITED STATES Sk h!
NUCLEAR REGULATORY COMMISSION j#
t WASHINGTON, D.C. 20555-0001 y
TENNESSEE VALLEY AUTHORITY DOCKET N0. 50-328 SE0V0YAH NUCLEAR PLANT. UNIT 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 168 License No. DPR-79 1.
The Nuclear Regulatory Commission (the Commission) has found that:
A.
The application for amendment by Tennessee Valley Authority (the licensee) dated January 8, 1993; which was supplemented by _
submittals dated April 1, May 3, and August 18, 1993; and February 22, 1994, complies with the standards and requirements of the f. comic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.
There is reasonable u surance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (!i) that such activities will be conducted in compliance with tia Commission's regulations; D.
The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
. 2.
Accordingly, the license is amended by changes to the Ter.hnical Specifications as indicated in the attachment to this license amendment and paragraph 2.C.(2) of Facility Operating License No. DPR-79 is hereby amended to read as follows:
(2) Technical Soecifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No.168, are hereby incorporated in the license.
The licensee shall operate the facility in accordance with the Technical Specifications.
3.
This license amendment is effective as of its date of issuance, to be implemented within 30 days.
FOR THE NUCLEAR REGULATORY COMMISSION 7g Frederick J. Hebdon, Director Project Directorate II-4 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation
Attachment:
Changes to the Technical Specifications Date of Issuance: March 15, 1994
ATTACHMENT TO LICENSE AMENDMENT NO. 168 FACILITY OPERATING LICENSE NO OPR-79.
DOCKET N0. 50-323 Revise the Appendix A Technical Specifications by removing the page identified below and inserting the enclosed page.
The revised page contains a marginal
-lines indicating the area of change.
REMOVE INSERT 3/4 4-32 3/4 4-32
REACTOR COOLANT SYSTEM 3/4.4.10 STRUCTURAL INTEGRITY ASME CODE CLASS 1. 2 and 3 COMPONENTS LIMITING CONDITION FOR OPERATION 3.4.10 The structural integrity of ASME Code Class 1, 2 and 3 components shall
_l be maintained in accordance with Specification 4.4.10.
t APPLICABILITY: All MODES EJ108:
a.
With the structural integrity of any ASME Code Class 1 component (s) not conforming to the above requirements, restore the structural integrity of the affected component (s) to within its limit or isolate the affected component (s) prior to increasing the Reactor Coolant System temperature more than 50*F above the minimum temperature required by NDT considerations.
b.
With the structural integrity of any ASME Code Class 2 component (s) not conforming to the above requirements, restore the structural.
integrity of the affected component (s) to within its limit or isolate the affected component (s) prior to increasing the Reactor Coolant System temperature above 200*F.
c.
With the structural-integrity of any ASME Code Class 3 component (s) not conforming to the above requirements, restore the structural integrity of the affected component (s) to within its limit or isolate the affected component (s) from service, d.
The provisions of Specification 3.0.4 are not applicable.
SVRVElllANCE REOUIREMENTS
-4.4.10 In addition to the requirements of Specification 4.0.5, each Reactor Coolant Pump flywheel shall be inspected per the recommendations of Regulatory Position C.4.b of Regulatory Guide 1.14, Revision 1, August 1975.