ML20064H847

From kanterella
Jump to navigation Jump to search
Monthly Operating Rept for Dec 1983
ML20064H847
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 01/10/1983
From: Jackie Cook
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To:
Shared Package
ML20064H833 List:
References
NUDOCS 8301170442
Download: ML20064H847 (10)


Text

.

OPERATING DATA REPORT DOCKETNO. _50-J31 DATE JANUARY 1983 J. COOK COMPLETED TELEPilONE BY(315) 342-384 OPERAllNG STATUS N '*5

1. Unit Name: FITZPATRICK
2. Reporting Period: 821201 - 821231
3. Licensed Thermal Power (MWr):

2436 4, 3,,m ,pgi,. g3 ;ng (cross y w ,): 883

5. Design Electrical Rating (Net MWe):

821

6. Masimum Dependable Capacity (Gross MWe): 830
7. Maximum Dependable Capacity (Net MWe):

810

8. If Changes Occur in Capacity Ratings (Items Number 3 Through 7)Since Last Report, Gise Reasons: ,
9. Power Lese! To Which Restricted. If Any (Mt MWe): NONE
10. Reasons For Restrictions. If Any:

This Month Yr.-to Date Cumulatise 744 8760 65137

11. Ilours in Reporting Period
12. Number Of flours Reactor has Critica! 607.6 6704.5 46255.7
13. Reactor Resene Shutdown llours 0 0 0 I4. Ilours Gencretor On Line 593.5 6571.6 45015.2
15. Unit Resene Shutdown flours 0 0 0
16. Grms Thermal Energy Generated (MWil) 1389144 15122544 93523858 17 Gross Electrical Energy Generated (MWil) 469390 5112300 32434780 Ih Net Electrical Energy Generated (MWill 454650 4959655 30864385
19. Unit Senice Factor 79.8% 75.0% 69.1%
20. Unit Asailabihtv Factor 79.8% 75.0% 69.1%
21. Unit Capacity I acior (Using MDC Neo 75.4% 69.9% 62.6%
22. Unit Capacity Factor (Using DER Neti 74.4% 69.0% 57.7%
23. Unit Forced Outage Ratc 20.2% 7 . 8'4 15.7%
24. Shutdowns Scheduled Oser Nest 6 Months (T3 pe.Date.and Duration of Each t
25. If Shut Down At End Of Report Period. Estimated Date of Startup:
26. Units in lest Status (Prior to Commercial Operationi: I orecast Achiesed INIT IA L CRillCA LI TY INill A L ELEC TRICITY COMMERCl A L OPER AllON 8301170442 830110 PDR ADOCK 05000333 R PDR

AVEft AGE DAILY UNIT POWER LEVEL DocKLINO. .50-333 UNIT JAFNPP DATE JANUARY 19_83 J. COOK COMPLETED SY _

TELErilONE(315) 342-384_0 MDNni DECEMBER 1982 DAY AVERAGE DAILY POWER LEVEL DAY AVER AGE DA LY POWER LEVEL (MWe-Net) (MWe Net) 794 ,7 0

I is 0 2 __ 795 793 19 0 3

20 0 4 79_3 793 21 0

s 6 793 22 21 793 23 404 7

8 793 24 702 790 9 744 25 785 780 26 f 30 755 797

27 795 28 796 12 794 29 795 13 794 30 795 14 794 3, 792 15 16 415

SUMMARY

The FitzPatrick plant operated at near full thermal power during this reporting period with one outage due to main steam isolation valve failure.

E

._ _ _ _ _ _ _ _ _ ._. _ . _ _ _ _ _ . . _ _ _ . _ _ _ _ . ._ _ _ . _ _ . . . _ - . _ . . _ - _ -- ._ _ . . -, . . _ _ . _ . m.-

I i

1 DOCKET NO. 50-333 -

UNITSilUTDOWNS AND POWER REDUCTIONS UNIT N AME JAFNFF 4 DATE JANUARY 1983 -

J. GOOK REPORT MONTil DECEMBER 1982 COMPLETED TELEPilONE BY(315) 342-3840

] w C .

, $? 3 $Y5 Licensee Eg {% Cause & Currective l N '- Date t 5? i 3se Event gy g'3 Action to d :. e 5

< 5 =s Repur a mL o v

Prevent Recurrence i O .

10 821216 F 150.5 A 3 82-057 HB VALVEX "D" inboard MSIV failure due to '

disc separation from system.

Valve repaired and returned to service.

}

i i

I

)

i j i 2 3 4 j F: Forced Reason: Method: Exhibit G Instructions

S: Scheduled A Equipment Failure (Explain) 1 -Manual for Preparation of Data I B Maintenance or Test 2 Manual Scram. Entry Sheets for Licensee C-Refuctin g 3. Automatic Scram. Event Report (LER) File (NUREG-D-Regulatory Restriction 4 Other (Explain) 0161)

E-Operator Training & License Examination F-Ad minist ra tive $

i G.Operationat Error (Explain) Exlubit 1 - Same Source Il-Othe r ( E xplain) -

i .

POWER AUTHORITY OF THE STATE OF NEW YORK JAMES A. FITZPATRICK NUCLEAR POWER PLANT NARRATIVE

SUMMARY

OF OPERATING EXPERIENCE DECEMBER, 1982 The unit operated at near full thermal power for the first fifteen days of the reporting period. On 821216 the unit tripped due to failure of the "D" inboard main steam isolation valve. The unit returned to service on 821222.

At the end of the reporting period the unit is operating at approximately 792 Mwe.

j I

i i

~ - - - .- , ,--. c-y ,, _

POWER AUTHORITY OF THE STATE OF NEW YORK JAMES A. FITZPATRICK NUCLEAR POWER PLANT j SAFETY RELATED ELECTRICAL & MECHANICAL MAINTENANCE

SUMMARY

DECEMBER 1982 E O ES DATE SYSTEM HOW DETECTED CAUSE OF MALFUNCTION ACTION TAKEN TO PRECLUDE RECURRENCE T EN L2/1 71 22204 VISUAL Permanent label not Engraved and installed permanent 4 MCC-163 installed on LPCI label breakers ,

L2/10 71 14887 N/A N/A Charged cell in preparation for 32 Stationary test discharge ,

, battery L2/9 10 17869 OPS Dried out packing Adjusted packing 1 MOV-27B L2/8 71 19454 S.T. Cell 166 will not Jumpered cell #166 6 Battery 3B charge L2/19 02 17880 OPS Faulty accoustic Replaced cables 9 RV 71J monitor cables L2/17 02 16379 OPS Leaking pilot valve Replaced pilot assembly 24 RV 71D Faulty IRM/APRM L2/18 07 18765 OPS Replaced switch 16 7A-S3C recorder switch 12/18 07 17310 OPS Faulty SRM selector Replaced switch 4 7A-S2 switch 12/20 07 19340 OPS Faulty SRM selector Replaced switch 6

7A-S1 switch 12/18 12 19401 DRYWELL Worn packing Replaced valve 6 MOV-15 LEAKAGE 12/16 13 22185 VISUAL Ground water leaking Cleaned out sleeve, packed with 16 RCIC line through sleeve Oakum and grouted

POWER AUTHORITY OF THE STATE OF NEW YORK JAMES A. FITZPATRICK NUCLEAR POWER PLANT SAFETY RELATED ELECTRICAL a MECHANICAL MAINTENANCE

SUMMARY

DECEMBER 1982 DATE SYSTEM OR O EST HOW DETECTED CAUSE OF MALFUNCTION ACTION TAKEN TO PRECLUDE RECURRENCE T l'2/19 14 15229 MODIFICATION No failure Installed cable tags 2 Cable tags 12/8 17 15106 MODIFICATION No failure Installed high range effluent 100 RE 53A & B monitors 12/16 70 16299 NOISY Wear Overhauled 120 RWC-2B 4

L2/16 71 17943 LOGIC FAILURE Electronic circuitry Replaced A8 logic board 8 INV-3A TRIP L2/21 71 14826 S.T. See WRED 71/14825 Installed new cell #8 8 Station

, battery L2/18 72 19500 S.T. Disconnected wire Re-connected wire 20 Battery caused erroneous ventilation indication L2/19 23 18996 VISUAL Erroded pipe fitting Replaced 90 el. 16 HPCI drain line i

12/18 29 16384 OPS Loose limit switch Tightened limit switch 6 AOV-80A 12/22 23 15839 OPS Steam cut on valve Replaced bonnet gasket with 40 A0V-53 body graphoil 12/22 29 17990 OPS Limit switch out of Readjusted 3 AOV-80D adjustment L2/22 29 16386 VISUAL Grounded limit switch Lifted lead-will replace switch 18 A0V-86B at a later date

POWER AUTHORITY OF THE STATE OF NEW YORK JAMES A. FITZPATRICK NUCLEAR POWER PLANT SAFETY RELATED ELECTRICAL & MECHANICAL MAINTENANCE

SUMMARY

DECEMBER 1982 DATE SYSTEM OR O EST HOW DETECTED CAUSE OF MALFUNCTION ACTION TAKEN TO PRECLUDE RECURRENCE T 12/19 34 20402 OPS Broken limit switch Replaced limit switch 10 NRV-lllA 12/28 29 17947 MALFUNCTION Main disc separated Double pinned with greater 446 AOV-86D CAUSED PLANT from piston penetration A0V-80D SHUTDOWN 12/21 10 17982 OPS Defective charging Replaced charging motor - 13 10620 motor 10PlB failed to adjusted drive and latch pawls start 12/18 23 17946 OPS Torque switch bypass Adjusted bypass contact 24 MOV-24 contact out of adjustment 12/22 02 18003 VISUAL Packing wear Adjusted packing 3 MOV-54B 12/22 23 18002 VISUAL Packing wear Adjusted packin; 3 MOV-15 12/20 10 17952 OPS Valve failed to close Tightened bolts 60 RHR-42C due to loose hanger mounting bolts

POWER AUTHORITY OF THE STATE OF NEW YORK JAMES A. FITZPATRICK NUCLEAR POWER PLANT .

MAINTENANCE

SUMMARY

I&C DECEMBER 1982 WORK REQUEST # CAUSE OF RESULTS OF ACTION TAKEN REPAIR 1 DATE SYSTEM HOW DETECTED TO PRECLUDE TlME COMPONENT # MALFUNCTION MALFUNCTION RECURRENCE HOURS 17879 Out of Repair and Performed 12/19 02 RV-71D replace i

JIC calibration . IMP-2.6 3 I i

acoustic monitor 18904 Transducer is Replaced Defective I 12/19 02 VMR-Oll OPS amplifier not amplifier 8 +

operating 19301 Functional Functional Performed 12/19 02 SRV JIC check check IMP-2.6 1 17876 Defective Will not work Replaced and 12/21 02-3 LIS-101D JIC instrument calibrated 41 18999 Functional Signal level Performed 12/17 02-3 SRV-H OPS check erratic. ST-22I 6

~

17967 Defective Rod 22-15 will Replaced '

12/20 03 22-15 OPS switch not select switch 12  ;

12/17 07 OPS Defective Pen will not Replaced amp amplifier read at all and calibrated 6 17963 Oil residue on Doesn't drive Replaced and 12/19 07 SRM-D OPS switch in and blows performed 32 fuses IMP-7 Check full out Performed *'

17966 limit f functional 12/19 07 IRM-H JIC None detect check 8 '

17991 Defective Dry indicator Replaced i 12/22 10 LS-103B OPS amplifier light is on amplifier 8

enrd when wet card 17788 MOV-94 was Reads > control Calibrated 12/10 20 FQX-550 OPS leaking

] cation FQX-550 10 C _- .._ _ __

- - .- _-= - _ _ . - ..

POWER AUTHORITY OF THE STATE OF NEW YORK JAMES A. FITZPATRICK NUCLEAR POWER PLANT ,

MAINTENANCE 911MMARY .

I&C DECEMBER 1982 DATE WORK REQUEST # CAUSE OF RESULTS OF ACTION TAKEN REPAIR 1 SYSTEM HOW DETECTED TO PRECLUDE '

COMPONENT # MALFUNCTION MALFUNCTION TIME RECURRENCE HOURS ,

17949 Loose Integrator Tightened loose i 12/17 20 FQX-527 OPS connection changing connection 2 17793 Switch won't Back flushed

  • 4 Dirty 12/13 23 DPIS-76 & 77 OPS snubbers trip-76 and and cleaned 14 vent-77 snubber i 19080 Didn't have Analyzer won't Made a proper {

12/03 27 MAZ-101B JIC proper ground calibrate ground 200 ,

21845 MOD-103 had a Restore temp broken flapper control in Had MOD-103 12/09 70 HVAC - JIC relay room repaired 64 18910 Defectiv Repair as Repaired boards 12/13 6 ZH-30 JIC

( m rter required nd calibrated 50 1

) i I

t

f POWER AUTHORITY OF THE STATE OF NEW YORK JAMES A. FITZPATRICK NUCLEAR POWER PLANT .

MAINTENANCE

SUMMARY

I&C DECEMBER 1982 DATE WORK REQUEST # CAUSE OF RESULTS 0:'

1 ACTION TAKEN ' REPAlR '

SYSTEM D TECTED T P9 E T COMPONENT # MALFUNCTION MALFUNCTION ,

R U 17916 Defective Picture fades Replaced  !

12/27 99 CCTV Cam 2 SECURITY resistor in and out monitor and 4 4 vonnited 17918 Defective Will not allow Replaced i 12/27 99 C.R. #125 -

SECURITY card reader any entry card reader 2 '

17919 Defective Replaced 12/28 99 X-ray monitor SECURITY pot / switch Not working pot / switch 5 '

19054 Defective Replaced 12/09 99 Camera 2 SECURITY transistor and No picture transistor and coil coil 24 19408 Broken wire Doesn't accept CR-125 SECURITY 2.n card card for Repaired broken 12/07 99 reader entry wire 1 19409 Alarm 513 SECURITY Out of Will not Adjusted 12/14 99 calibration alarm sensitivity 2 19411 Defective Replaced camera No clear l 12/14 99 CCTV Cam 6 SECURITY Power cord and picture 6 with 8

vidilon another Install cable .

12/18 99 p ter SECURITY None None sec 4

i i i I

I i