ML20064H455

From kanterella
Jump to navigation Jump to search
Rev 2 to VC Summer Charging/Safety Injection Pump Runout Flow Evaluation
ML20064H455
Person / Time
Site: Summer 
Issue date: 03/07/1994
From: Swantner S, Testa D
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To:
Shared Package
ML19304B842 List:
References
NUDOCS 9403170305
Download: ML20064H455 (177)


Text

.

u V. C. SUMMER CHARGING / SAFETY INJECTION PUMP I

RUNOUT FLOW EVALUATION

' t Revision 2 Prepared for SOUTH CAROLINA ELECTRIC & GAS March 7,1994 I

l Prepared by:

-[Y r

td Stephen R. Swantner

./

_.A.

Verified by:

h / 8Ad Damian A. Testa I

Fluid Systems Engineering Westinghouse Electric Corporation t

I MN'81112 N) 1 9403170305 940311

- PDR ADOCK 05000395 4

p PDR 4

m-

V. C. SUS 15fER CilARGING / SAFETY INJECTION PUNIP RUNOUT FLOW EVALUATION (REV. 2) -

TABLE OF CONTENTS 1.0 Execative Summary 2.0 Evaluation Scope 3.0 Runout Test Performance 4.0 Test Data Collection 5.0 Evaluation of Pump Test Results 6,0 Pump Evaluation Summary and Conclusions 7.0 Implementation of Increased Runout Limits 8.0 References TABLE 1: Available NPSH Based on Re.sistance Reduction Factor = 0.6 ATTACilMENTS:

1.

Test Termination Criteria From SCE&G Procedure STP-230.006A '

2.

Average Overall Vibration Analyzer Readings 3.

Detailed Vibration Analyzer Data 4.

CH/SI Pump Performance Curves 5.

"As Found" Pump Head / Flow data 1

Page 2 L R(Call t A03

1 i

V. C. SUMMER CHARGING / SAFETY INJECTION PUMP RUNOUT FLOW EVALUATION (REV. 2) 1.0 EXECUTIVE

SUMMARY

South Carolina Electrie & Gas conducted runout flow verification testing of the Virgil C. Summer Nuclear Station (VCSNS) centrifugal charging / safety injection (CH/SI) pumps in response to the concerns of Westinghouse notification letter CGE-91-152, dated 9/27/91 (Ref.1). The verification testing was performed as part of VCSNS test procedure STP 230.006A & B, which also included system flow balance testing. The test procedure included pump testing at a maximum flow rate of 710 gpm, which bounds the maximum flow that the VCSNS CH/SI pumps will see during any plant normal or accident operating mode. Westinghouse and Ingersoll-Dresser Pumps (IDP) were requested to witness the testing of the CH/S! pumps and to determine the acceptability of pump operation at 710 gpm based on the data and observations from the test.

The test was conducted on VCSNS CH/S! pumps A, B and C. CH/SI pumps A & B were each tested to a maximum runout flow rate of 708 gpm. However, pump C was shut down prior to completion of test procedure STP 230.006A due to light smoke being detected near the inboard bearing housing.

Pump C was operating at 696 gpm at the time it was secured. The inboard bearing housing was later disassembled and inspected. The source of the smoke was determined to be a minor rub of the close-tolerance oil seal battles and not the bearing itself. The problem was resolved by replacement of the oil baffles.

Westinghouse has concluded that CH/S! pumps A & B operated acceptably, under test conditions, at 708 gpm. Westinghouse also concludes that pump C will be acceptable for operatie "mier similar conditions at 708 gpm. The problem encountered with the oil baffles was strictly a mechanical problem which was unrelateo 'o the runout testing. No indications of adverse cavitation were present during the runout testing of Pump C. The pump evaluation, the supporting test data and the bases of the Westinghouse conclusions are presented in this report.

Page 3 utenm:m

V. C. SUMMER CilARGING / SAFETY INJECTION PUNIP RUNOUT FLOW EVALUATION (REV. 2) 2.0 EVALUATION SCOPE The current VCSNS Technical Specification limit for CH/S1 pump runout is 680 gpm. Based upon Westinghouse letter CGE-91-152, SCE&G has administratively limited maximum CH/SI pump flow to -

675 gpm, since the pump vendor does not have sufficient test data to support flow rates higher than 675 gpm. The purpose of the subject pump testing was to verify acceptable pump operation up to 680 gpm and thereby eliminate the need for lower administrative limits, and to demonstrate that the safety injection system can support a higher runout limit. The increased pump runout flow beyond 680 gpm provides additional margin for system operation.

VCSNS CH/SI pumps A, B & C (IDP! Pacific Model 2% inch RL/1) were tested under SCE&G procedure STP 230.OO6A to collect data necessary to evaluate the acceptability of pump operation at now rates up to 710 gpm This tiow rate exceeds the generic 675 gpm flow limitation established in letter CGE-91-152. The 710 gpm was established as a bounding tlow for all pump operating modes including post-LOCA injection and recirculation. The pumps were tested under the injection mode-suction conditions. This is considered to be more critical than the recirculation mode suction conditions, which include a large pressure boost fmm the RHR pumps. The scope of this evaluation is to determine if the pumps operated acceptably during the runout Dow testing. The basis of the evaluation is the pump data and observations that were recorded during the testing.

3.0 RUNOUT TEST PERFORMANCE The charging pump runout testing was performed with suction from the RWST and discharge to the RCS through the cold leg branch lines and the normal charging line. The pump recirculation paths were isolated. The RWST level was between 21-22% and the fluid temperature was approximately 70"F during the test. RWST isolation valve LCV 115B was open and LCV-ll5D was closed. De maximum measured CH/SI pump Dow rate was 708 gpm. Based on pump suction pressure measured by means of a Heise gauge, the available NPSH was calculated to be about 63.5 feet. In addition, the hydraulic head loss was calculated based on the measured RWST level and pump suction pressure.

The measured head loss was approximately 60% of the head loss determined from hydraulic resistances calculated from the piping layout drawings using handbook loss coefficients. This is consistent with observations made in previous comparisons between measured and calculated system ouwm:m Page 4

~

P V. C. SURIN1ER CliARGING / SAFETY INJECTION PUSIP RUNOUT FLOW EVALUATION tREV. 2) head losses. The calculated hydraulic resistance were therefore multiplied by 0.6 to provide l

consistency with test data.

1 The available NPSif is calculated as:

i

.i NPSHa = H

+ Ha sr - H, - AHs,, - H, Where:

H,,

= atmospherie head, it li n,r

= elevation head. It H

= CH/SI pump centerline elevation, it ecy A H u,,,

= hydraulic los.ses between RWST and CH/SI pump, ft Hv,

= equivalent head at vapor pressure, it The values of the above parameters during runout testing are shown in Colum 11 of Table 1.

The CH/SI pumps were operated for the runout thiw test in accordance with the identified test procedure, which was based on Westinghouse letter CGE-92-064 (Referenec 2). The termination eriteria established in the procedure (see Attachment 1) were closely monitored at each 110w point.

The pump 110w, developed head lluctuations, thrust bearing oil temperature, vibration levels, motor amperage and motor amperage fluctuations were monitored in accordance with the test procedure.-

Throughout the duration of the test, each pump's hydraulic noise was carefully monitored for audible signs of cavitation. The suction and 2nd stage areas of the pump are typically the areas where signs of cavitation are first detected. No discernible envitation noises were observed. In fact, all of the monitored parameters stayed within the appropriate termination criteria as identified in Attachment 1.

Since the test termination criteria were not met, pumps A. and 8 were run out to the maximum allowable test llow point (nominally 710 ppm) in accordance with the test procedure. However, pump.

C was sceured prematurely, at a tiow rate of 696 gpm, when light smoke was observed coming from the inboard pump bearing housing, Page 5 1invRIi12m

V. C, SUN 151ER CilARGING / SAFETY INJECTION Pt31P RUNOUT FLOW EVALUATION (REY. 2) 4.0 TEST DATA COLLECTION Cll/S! pump suction pressure, discharge pressure, lube oil temperature, bearing housing vibration (recorded with vibration meter), motor amperage and suction temperature were all recorded per procedure STP.230.(H)6A. The Cil/SI pumps were continuously and carefully monitored during the execution of the test procedure. The procedure required the operation of the pumps at increasing flow rates of approximately 620 gpm,660 gpm,675 gpm,680 gpm,690 gpm,700 ppm and 710 gpm. All critical parameters were monitored at each flow point and the data was scrutinized for development of potendai adverse trends at each flow point.

The pump vibrations were monitored during testing with both a vibration analyzer and a vibration meter. The vibration analyzer '(CS! model 2110) provided vibration spectra and overall velocity readings. The vibration meter (IRD model 306) provided overall velocity and displacement readings.

The vibration meter was the official device used for comparison to the test termination criteria. The analyzer, which is used at VCSNS for predictive maintenance, was used to record supplemental data for use in this evaluation. The vibration analyzer data collected during the runout flow tests is included in Attachments 2 and 3.

The vibration levels in Attachment 2 represent overall velocity readings that were recorded with the vibration analyzer. As recommended by Westinghouse, data was collected twice over an interval of several minutes at each flow rate. No appreciable differences in the two readings were noted. The data tabulated and graphed in Attachment 2 are the averages of the two sets of test readings.

The vibration spectra for each of the official test flow points are included in Attachment 3. The readings were taken with the analyzer probe manually held against each test point (inboard and outboard bearing housings and pump casmg). For pump casing readings (labelled " Piping liigh Freq' in the analyzer output from Attachment 3), the probe was held to the pump casing near the suction nozzle, in a radial orientation, about 30" to 45' above horizontal.

Page 6 E Rwsn t:m

V. C, SU.\\1,\\lER CilARGING / SAFETY INJECTION PIStP RUNOUT FLOW EVALUATION (REV,2) 5.0 EVALUATION OF PUMP TEST RESULTS The specifie llow rates at which each pump was tested are documented in Reference 3 (see ). The nmimum actual test llow rate for pumps A and B is 70S gpm (each). As stated previously, pump C was secured at a maximam tiow rate of 696 gpm, when light smoke was observed coming from the inboard pump bearing housing. No vibration analyzer readings were able to be taken at 646 gpm before pump C was secured. The maximum actual tiow rate at which vibration data was taken was 688 ppm.

All data recorded during the testing was within the allowable values established by the termination criteria. The fact that the termination criteria was satisfied at all flow rates indicated that the there were no significant hydraulic or mechanical mechanisms that could result in short-term damage to the pumps.

1 In general, the overall vibration data for each pump indicate that the increased flow rates did not result f

in signilicantly increased vibration levels. The pump casing readings for pumps A and C do show an i

increase with increased flow, but all readines are well below the termination limit of OA in/sec. The 1

pump B casing vibration increased with tiows up to 673 gpm, but then began decreasing.

The detailed vibration data and response spectra plots in Attachment 3 show general agreement with the trends identified in the overall vibration readings in Attachment 2. All significant vibrations at the bearing housings occurred at discrete frequencies, generally lx,2x,6x and 18x running speed (~80 Hz).

These are mechanically produced vibrations associated with shalt alignment, bearing noise and blade passing noise. These vibrations appear to be unrelated to flow rate.

i l

The response spectra of the pump casings show somewhat broad, low level vibration, generally in the range of 2000 - 3000 Hz. Although the vibration energy increased with increasing flow rate in pumps A and C, no new f requencies developed at the higher llow rates. This may indicate hydraulie noise, low level cavitation, or both. However, since the vibration readings were well below the termination criteria for the runout test, any low level cavitation present would not adversely affect the pumps at the flow rates tested. This vibration pattern had essentially disappeared in pump B by 700 gpm.

Page 7 mwom

V.-C. SUMMER CilARGING / SAFETY INJECTION PUMP i

RUNOUT FLOW EVALUATION (REV.- 2)

. contains performance (developed head vs. flow) curves for each of the three pumps.

Each curve presents an overlay ot runout test data (see Attachment 5) with the applicable vendor shop test curve. For each pump, the runout test performance curve shows a gradual drop in head as the llow ra;e approaches the runout test limit, consi, tent with the slope of the vendor curve. This indicates that little or no cavitation ettcets were present during the runout testing.

4 The vibiation and developed head data clearly demonstrate that, as the flow through each pamp was increased to the maximum test point, there was no significant increase in vibration levels at any sonitorcd frequency. No new frequency responses can be detected at the higher flow rates. Based on this data. it is concluded that there was no detectible or detrimental cavitation at the maximum test flow of 70s gpm.

Additionally, the hydraulic sound in each pump was carefully listened to at each flow point. A long metal rod was used a3 a " stethoscope" to amplify the pump noises and proviiS early detection of abnormal or changing noise patterns. The audible noise energy seemed to increase slightly, but gradually, with increasing tlow tor each pump. However, no definite cavitation noise was detected by human ear in the pump suction nonle, the pump suction cavity and the first several pump stages.

Alter completion of the runout test program, the inboard bearing housing from Pump C was disassembled and inspected. The source of the smoke was determined to be a minor rub of the close-tolerance oil seal battles and not the bearing itself. The problem was resolved by replacement of the oil baffles. This is considered to be strictly a mechanical problem which was unrelated to the runout testing. No indications of adverse cavitation were present during the runout testing of Pump C.

6.0 PUMP EVALUATION

SUMMARY

AND CONCLUSIONS i

The charging pump runout testing was performed with suction from the RWST and discharge to the

i RCS through the cold leg branch lines and the normal charging line. The pump recirculation paths were isolated. The RWST level was between 21-22% and the fluid temperature was approximately.

70"F during the test. RWST isolation valve LCV-Il5B was open and LCV 115D was closed. The Page 8 tu m oan I

o

V, C. SUMMER CilAPGING / SAFETY INJECTION PUMP RUNOUT FLOW EVALUATION (REV,2) maximum measured CH/SI pump flow rate was 708 gpm. Based on pump suction pressure measured by means of a Heise gauge, the available NPSH was calculated to be about 63.5 feet. In addition, the hydraulic head loss was calculated based on the measured RWST level and pump suction pressure.

The measured head loss was approximately 60G of the head loss determined from hydraulic resistances calculated from the piping layout drawings using handbook loss coefficients. This is consistent with observations made in previous comparisons between measured and calculated system head losses. The calculated hydraulie resistance were therefore multiplied by 0.6 to provide consistency with test dat:.

Table 1 provides a summary of the NPSH available to the CH/SI pumps during the test conditions and dunng various postulated post-accident conditions. Four different post-accident conditions were considered; i) failure of an electrical train, ii) tailure of a Cil/SI pump to start, iii) failure of valve LCV-115D to open, and iv) RWST empty alarm reached during switchover sequence. Virgil Summer operating procedure EOP 2.2, Transfer to Cold leg Recirculation, instructs the operator to isolate the containment spray (CS) pump suction trom the RWST before isolating the RHR pump suction from the RWST. After the CS and RHR pumps are isolated from the RWST, the operator aligns the charging pump suction to the RHR pump discharge and isolates the charging pump suction from the RWST. As a result of the switchover sequence, the available NPSH to the charging pumps was calculated at 3 distinct points during each post-accident condition: a) just prior to isolating the CS i

pumps from the RWST, b)just prior to isolating the RHR pumps from the RWST, and c)just prior to j

isolating the CH/SI pumps from the RWST. It was assumed that the CS pumps are isolated from the

)

RWST within 2 minutes after the RWST Isle Trip setpoint (18%), and the RHR pumps and charging pumps are isolated from the RWST in subsequent 1 minute intervals. The final case assumes j

that the RWST empty alarm setpoint is reached before the switchover sequence is completed. Once again, three cases were considered: a) assume CS, RHR, and CH/SI pumps are drawing from RWST when empty alarm is reached, b) assume RHR and CH/S1 pumps are drawing from RWST when empty alarm is reached, and c) assumed only CH/S1 pumps are drawing from RWST when empty alarm h, reached. It was assumed that any pumps operating when the RWST empty alarm is reached

]

are immediately isolated.

Page 9 t rean um

~

V. C. SUhlS1ER CHARGING / SAFETY INJECTION PUNIP RUNOUT FLOW EVALUATION (REV. 2)

. The following observations are made concerning the results reported in Table 1.

1)

The available NPSH to the CH/SI pump during runout testing was 63A feet.

2)

A post accident RWST lluid temperature ot 90"F was assumed. This was the highest RWST temperature measured during Cycle 6 operation. The monthly average temperatures during Cycle 6 varied from a low of 59.5"F (Feb 91) to a high of 87.4"F -

(July, 90).

3)

RWST level measurement uncertainties were not considered in calculating the NPSHa during either test or postulated post accident conditions. Therefore, the le le trip i

setpoint was assumed to occur at 1WX water level and the empty alarm at 6% water level.

4)

As previously discussed, for Cases 2-4 it was assumed that the CS, RHR, and CH/S!

pumps were isolated from the RWST 2,3, and 4 minutes, respectively, alter receipt of the Lo-lo trip.

j 5)

For Case 5 it was assumed that the RWST level variation between receipt of empty alarm and isolation of any operating pumps is negligible.

6)

The minimum NPSHa during postulated post-accident conditions occurred for Case 5a and was 52 feet. This case is very conservative since it assumes the operator does not isolate any of the operating pumps from the RWST before the empty alarm is reached.-

The results of the runout testing, in conjunction with the data in Table 1, were used to establish operating limits for the CH/SI pumps.

All three V. C. Summer CH/SI pumps operated acceptably during the pump runout flow testing _

performed per procedure STP 230.006A. This conclusion is based upon test results, observations and '

engineering evaluation of the test data. Pumps A and B were each successfully tested at a maximum

. runout flow rate of 708 gpm. Pump C was tested at flow rates up to 696 gpm. The operating Page 10 twnsn u m

m

~ _

V. C. SUMMER CilARGING / SAFETY INJECTION PUMP RUNOUT FLOW EVALUATION (REV. 2) characteristics of pump C were consistent with those of pumps A and B, at similar flow rates, it is therefore concluded that all three CH/SI pumps. can operate at flow rates as high as 708 gpm during the post LOCA injection or recirculation modes with no unusual damage or degradation to the pumps.

This conclusion is justitied as long as the nel positive suction head available (NPSHa) to the operating pump is greater than or equal to the test level of 63.5 feet.

During post-LOCA conditions with two spray pumps,2 RHR pumps, and 1 CH/SI pump operating,-

the available NPSH to the CH/SI pump decreases to 63.5 feet when the RWST level is at 30% due to '

the increased line losses resulting from the high RWST outflow, The available NPSH decreases to 52 feet when the RWST empty alarm (tW) is reached. In order to assess pump runout operation at NPSHa as low as 52 teet, Westinghouse and Ingersoll-Dresser Pumps have reviewed performance data-(horsepower, developed head and NPSH required versus now rate) recorded during shop tests of similar punips. The NPSH required by these pumps increases rapidly as the pump flow approaches -

runout. This means that small changes in NPsH available can have potentially significant impact on pump reliability. Therefore, alter review of available shop and lield test data, the maximum flow rate at which these pumps may be continuou.ly operated is concluded to be 700 gpm at a NPSHa of.

greater than 52 feet.

7.0 (MPLEMENTATION OF INCREASED RUNOUT LIMITS Virgil Summer ECCS technical specilication 4.5.2.h places limits on the Cil/SI system hydraulic characteristics. This is accomplished by placing limits on the minimum and maximum allowed system-1 flow rates during llow balance testing performed following system modifications. The minimum flow limit requires that the sum of the injection line llow rates, excluding the highest How rate, is greater than or equal to 338 gpm. This limit verif'ics that the CHG/SI emergency core cooling Dow rate exceeds the minimum performance assumed in the FSAR accident analyses. The maximum now limit currently requires that the total pump flow rate is less than or equal to 680 ppm. This limit verifies I

that pump runout tiow rate is within component and system limitations.

j The minimum now limit in specilication 4.5.2.h will remain at 338 gpm However, the pump runout limit will be revised to 700 gpm. This revision will increase the band between minimum and I

maximum allowed flow rates and will facilitate system set-up and operability verification. The twnuum Page 11 l

'I

- i 1

-~

... ~

. I

- V. C. SUMSIER CllARGING / SAFETY INJECTION PUNIP RUNOUT FLOW EVALUATION (REV,2) -

justification for this revision is summarized below.

The minimum NPSH available to a single operating Cil/SI pump during post-LOCA operation is 52 lect. W Auxiliary Equipment Engineering and Ingersoll-Dres.ser Pumps have concluded that a Cil/SI pump can operate indefinitely at an NPSHa of 52 feet if the pump flow rate does not exceed 700 gpm.

This conclusion is based on the CH/SI pump runout flow test data documented herein. Therefore, 700 gpm is an acceptable upper limit for CH!SI pump runout flow rate.

A CHiSI pump runout flow rate of 700 gpm is approximately 3'1 higher than the original pump design runout llow rate of 6SO gpm. This slight increase in flow rate is acceptable as regards system performance. System head losses and velocities remain within acceptable limits.

t t

j r

1 4

e nuwo u su Page 12 1

V. C. SUMMER CIIARGING / SAFETY INJECTION PUMP RUNOUT FLOW EVALUATION (REY. 2)-

8.0 REFERENCES

1.

W Letter CGE-91-152,9/27/91, " Emergency Core Cooling System Pump Runout Limit issues" 2.

W Letter CGE-92-064,6/16/92, " Updated Guidelines for St Pump Runout Test" 3.

SCE&G Engineer's Technical Work Record, " Engineering Evaluation for STP 230.006A & B RF 7," Tab 93-10, Serial 251394263, by W. T. Wood, 4/16/93.

4 W Letter CGE-93-0020SGUL,5/17/93, "VCSNS RSG/Uprating: Draf t Report on Charging Pump Flow Test" 5.

IDP Letter to SCE&G,6/14/93, " Steam Generator Project / Cil/SI Pump Runout Evaluation" i

l kO 88 t l244 Page 13

i V. C. StlNihlER CilAHGING / SAFETY IN.IECTION l't! Nil' 4

HtINotrr Fl.OW EVAI.IIATION (Iter. 21 TAllt.E I Asaitalile NI'Sil liased on Resistance Reduction Factor = 0.6 Case 1

2a 21, 2c 3a 3 16 3c Ja 41, 4c Sa 51, 5c l'luid Temp.

7trF 9trF 9trF 9(rF 9trF MrF 90 F

'M r F 9trF wrF 9trF

<x rF virF ltWST Flow -

CSS O

3000 0

0 NNN)

O O

NHMl 0

0 NHH) 0 0

Itlllt 0

45(N) 458HI O

6900 6400 0

6M N) 6'M N )

0 6'M N) 45(H)

O Cil/SI 710 710 710 710 710 710 710 1200 1200 1200 710 710 710 ATSI l'arssuir 34 34 34 34 34 34 34 34 34 34 34 34 34 4

ItWST l.csel 425.7 42235 421.8 421.7 421.2 420.4 4203 421.1 420.2 420.1 417.7 417.7 417.7 CilG/SI Elev.

3913 391.5 391.5 391.5 391.5 391.5 391.5 391.5 391 5 391.5 391.5 391.5 391.5 Ilead less 3.75 5.2 43 3.75 6.6 3.9 2.7 M.8 6.0 4.7 6.6 43 3.75 Vapor l'ress 0.84 1.6 1.6 1.6 1.6 -

1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 NI'Sila 63.6 58.1 58.4 58.8 55.5 57.4 58.5 53 '

45.1 563 52.0 54 3 54.M Cll/SI l'urnp 710

, 710.

710 710 710 710 -

710 NIO NN)

MHI 710 710 710 l'Io n

. Page 14 am 2.m r.-..

V. C. SUS 15f ER Cl{ ARCING / SAF L 1 ) INJECTION P131P RUNOUT FLOW-EVALUATION (Res. 21-TABLE 1 LEGEND CASE No.

DESCRIITION 1 -

Test Conditions 2-Post-Accident - Train Failure 3-Post-Accident - CH/SI Failure 4 -

Post-Accident - LCV-115D Fail to Open 5-Post Accident - RWST at Empty Alarm a -

RWST level prior to isolating CSS from RWST Level = 4:4.1

'"""""H2

""") = L, 9400 gatift b-RWST level prior to isolating RHR from RWST Le v e l = L,

' "" " ""'""* " ' "'"" = L, 9400 galift RWST level prior to isolating CH/S! from.RWST e

Le v e l = L - ("*"""" '"'"'

9400 gal /ft Page 15 ruvun:..

V. C. SU515tER CllARGING / SAFETY INJECTION Pl!S1P RUNOLT FLOW EVALUATION tRes. 2)

ATTACilMENT 1 TEST TER311 NATION CRITERIA FRONI SCE&G PROCEDURE STP 230.006A L

t f h(Yhk} } M

STP 230.006A ATTACHMENT LA PAGE 10F 5 REVISION O STT3d TEST DATA SHEET CHARGING /5l PUMP A RUNOUTTEST INITIAL DATE 6.2.1 Pump Runout testing of XPP0043A. CHARGING /51 PUMP A C. XVG08485A C5, THROTTLED CLOSED 9.75 turns,

/

D. FCV 122, CLOSED

/

E. MVG-8107 and MVG-8108, OSEN

/

6.2.1.F.2 Calculated flow for IFE00122, GPM

6. 2.1. H.11 Flow greater than 100 gpm on Fi-943.

/

6.2.1.H.12 MVT-4109A, CLOSED

/

Charoina/51 Pump Runout Test Termination Criteria To Prevent Pumo Damace:

A.

Flow Total pump flow shall not exceed 710 gpm.

B.

Developed Head No fluctuations greater than 5% while operating at a fixed system resistance.

C.

Thrust bearing temperature Lube oil temperature shall not exceed 155'F at the beanng housing outlet.

D.

Bearing housing vibration Bearing housing displacement shall not exceed 1.5 mils peak-to peak or velocities not to exceed 0.4 in/sec. All values are to be filtered to running speed. The use of overall readings is acceptable.

E.

Motor current Motor current shall not exceed the followmg:

1. At a bus voltage of 6900 V,75 amps.
2. At a bus voltage of 7200V,72 amps.
3. At a busvoltage of 7450V,69.5 amps.

F.

Sound No discemable cavitation " marble

  • noises.

V. C. SUMMER CilARGING / SAFETY INJECTION PUMP RUNOLT FLOW EVALUATION (Ro. 2)

ATTACllMENT 2 AVERAGE OVERALL VIBRATION ANALYZER READINGS Tables and graphs of the overall vibration data that was recorded with the vibration analyzer are included in this attachment.

Note:. The tollowing abbreviations are used in this report to refer to the locations where vibration measurements were recorded:

Pill -

pump inboard bearing. horizontal, in/sec Piv -

pump inboard bearing, vertical, inisec Pol-I -

pump outboard bearing, liorizontal, in,ser POV -

pump outboard bearing, vertical, inisec POA -

pump outboard bearing, axial, in/see CS R -

pump casing at suction nozzle, radial, in7see r

IR&#11 tJ4e l

V.C. SUMMER CH/SI PUMP RUNOUT TEST DATA - PUMP A V.C. SUMMER CH/SI PUMP A AVERAGE OVERALL VIBRATION ANALYZER READINGS 0.4 l

l i

3 0.3 M

l!

l z

i 0 0..

?~

j l

i l

1 M

\\

,A 0.1

^ ' ' ' '

~

P*

i i

0 600 620 640 660 680 700 720 MEASURED FLOW RATE (gpm)

__ PIH

_._ PIV _._. POH + POV POA __ CSR

- LOCATION

+

PlH I

PlV i

POH I

POV POA i

CSR Flow (mm)

AVERAGE OVERALL VIBRATION ANALYZER READINGS (in/sec)

. 629r 1

0.07901 0.04261 -0.08921 0.09041 0.09261 0.0449!

'566i i

0.0778i 0.03791 0.0911i 0.1030!

0.1012i 0.0609i 676!

0.07831 0.0377I 0.08901 0.10991 0.1042:

0.0613i 688I i

0.07871 0.03841 0.08701 0.11251 0.11531 0.0642' 699i j

0.0814i 0.03941 0.0922!

0.1062i 0.1155I 0.0846i 708i t

0.08171 0.0433i 0.09171 0.0992!

0.1425i 0.1137i

... ~

V.C. SUMMER CH/SI PUMP RUNOUT TEST DATA - PUMP B V.C. SUMMER CH/SI PUMP B AVERAGE OVERALL VIBRATION ANALYZER READINGS 0,4 l

}0.3

$^

i i

0

'2 i

E k_

l_FC

' TM

'oi 3;;;

3 r

%/

j 0

600 620 640 660 680 700 720 MEASURED FLOW RATE (gpm)

_._. PIH + PIV

_~ POH + POV POA CSR Y

LOCATION - - - - - >

PlH I

PlV i

POH I

POV POA i

CSR

~ Flow (gpm)

AVERAGE OVERALL VIBRATION ANALYZER READINGS (in/sec) 612' 0.2163i 0.11721 0.0987 j 0.1109i.

0.07241 0.0632:

y 0.22201 0.11651 0.08581 0.09701 0.08231- 0.0565i

')

626 1

644 0.2186i 0.1186I 0.1054i 0.1062j 0.08881 0.1089i 657I-0.2135i 0.10911 0.1111i -0.1095 0.0951!

0.12191

'673i 0.21431 0.1167I 0.11841 0.1137 0.0989i 0.1280!

678!

l 0.2067i- 0.1172j 0.1181{

0.1279I 0.0966i 0.0916l 689-0.20681 0.10911 0.1237I 0.1270}

0.1116I 0.-1023i 698:

i 0.2102i 0.1163I 0.1302l 0.12511 0.1028I 0.0812t 708!

O.20981 0.1218!

0.13661 0.1426I' O.09781 0.0810, e-

  • =

V.C. SUMMER CH/SI PUMP RUNOUT TEST DATA - PUMP C V.C. SUMMER C-1/SI PUMP C AVERAGE OVERALL VIBRATION ANALYZER READINGS 0.4 l

i

}0.3 l

i 5

i z

O 0.2 p

x 0.1

'e

.a

-_ W

~

l i

I j

1 O'

600 620 640 660 680 700 720 AEASURED FLOW RATE (gpm)

_._ PIH

+ PIV POH + POV POA + CSR LOCATION PlH i

PlV I

PCH i

POV i

POA CSR Flow (ggm) i AVERAGE OVERALL VIBRATION ANALYZER READINGS (in/sec)E 622I l

0.1014 0.0489!

0.2706I 0.15261 0.0418i 0.0388; 666!

0.0827 0.0354i 0.2837!

0.0976i O.0371; 0.0663!

6791 0.08351 0.0378!

0.2869I 0.10011 0.0392!

0.0705l 688!

0.0858!

0.0373!

0.29171 0.1043!

0.0386i 0.0781' f

w

.i

V. C. SU.\\l.\\lER Cl{ARGING / SAFETY INJECTION PU.\\tP RUNOUT FLOW EVALUATION (Res. 2)

ATTACil.N!ENT 3 DETAILED VIBRATION ANALYZER DATA The detailed vibration test data recorded under test procedure STP-230.006A is include; in this attachment. Velocity vs. frequency response spectra are included for all three pumps.

?

LRC9'aill249) x - - -

AUXILIARY BUILDING

$PCCTRA FROM NOPC THAN Ort MACHINC on?mn9Sa?---o?

9 9 -,-

0 AP 36 u

PLOT i

d

$ PAN 70g Gpn.Ag.16V l

I I

i 1 '

y 8,060 -

1 J-_

06-APR-93 00836 a

690 GPM-A2-16V g

- l 2 l a

a i '

06-APR-93 00:30 Om

, j 1

pp 9 gg U

1

-AP 45 INIT!AL-A2-16V

- I - - --

  • 1 05-APR-93 21449 F

0 400 800 1200 1600 2000 rREQUENCY IN H2 SPC6s.02132 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

710 GPM-A2-16V PUMP INBD VERTICAL Date/ Time:

06-APR-93 02:36:34 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.73

.0213 1.00 13 769.41

.0032 9.56 2

117.79

.0037 1.46 14 783.89

.0032 9.74 3

146.87

.0050 1.83 15 807.71

.0093 10.04 4

161.48

.0107 2.01 16 814.04

.0031 10.12 5

211.25

.0063 2.63 17 968.69

.0084 12.04 6

221.06

.0073 2.75 18 1372.32

.0065 17.05 7

226.33

.0061 2.81 19 1453.06

.0121 18.06 8

236.17

.0033 2.94 20 1533.75

.0048 19.06 9

242.18

.0066 3.01 21 1614.51

.0039 20.06 10 484.24

.0066 6.02 22 1856.98

.0054 23.08 11 676.03

.0030 8.40 23 1893.78

.0032 23.53 12 726.32

.0049 9.03 24 1937.62

.0099 24.08 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0446

.0028

/

0%

.0295

/ 44%

.0333

/ 56%

P1/ Enter = Accept F2= Paging is ON F7= Title F9= Copy Esc = Quit i

i

AUX 1LIARY BUILDING SPECTRA FROM MORC THMt ONE MACHINE ca 710 GPM-A2-17H gJSmnon-9monnmn9T_99mioa 06-APR-93 02:36 o

PLOT SPAN 1

700 GPM-42-17H g

0.12 <

.h--

1 i

06-APR-93 00:37 r

w I

06-AP 9 -

30 b

680 GPM-A2-17H h

0.

A_

1 06-APR-93 00:11 a

i 675 GPM-A2-17H t _b __,

a 1 05-APR-93 23846 2

IN!T!AL-A2-17H

=

f i -

t 1 05-

-93 21849 0

400 800 1200 1600 2000 ORtRs 1.003 FREQUENCY IN HZ SPC6s.05768 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

710 GPM-A2-17H PUMP INBD HORIZONTAL Date/ Time:

06-APR-93 02:36:48 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.73

.0576 1.00 13 264.01

.0064 3.28 2

131.55

.0063 1.63 14 383.30

.0048 4.76 3

138.41

.0086 1.72 15 707.73

.0052 8.80 4

146.69

.0115 1.82 16 807.18

.0091 10.03 5

153.73

.0048 1.91 17 968.58

.0056 12.04 6

161.38

.0188 2.01 18 1372.27

.0082 17.05 7

191.04

.0100 2.37 19 1453.01

.0183 18.06 8

196.58

.0061 2.44 20 1533.83

.0090 19.06 9

205.74

.0052 2.56 21 1614.56

.0087 20.06 10 220.87

.0053 2.74 22 1776.06

.0140.

22.07 11 228.49

.0050 2.84 23 1856.4'l

.0063 23.07 12 242.19

.0114 3.01 24 1937.37

.0053 24.08 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0794

.0078

/

1%

.0640

/ 65%

.0464 -/ 34%-

-l F1/ Enter = Accept F2= Paging is ON F7= Title F9_= Copy Esc = Quit' l 1

AUXILIARY BUILDING SPEC

  • IRA FROM NORC THAN ONE MACHINC I

710 GPM-A2-19Y

_o-naanmno-

__'h n_nmm 06-APR-93 02:37 o

PLOT d

SPQtt 700 GPM-A2-19V g

0.14 -

1 06-APR-93 00:38 b

690 GPM-A2-19V g

-___2 06-APR-93 00130 8

h see GPn-A2-tsv h

0- g.

j 06-APR-93 00:11 E

a 67s cen-42-i9v u_

i_

1 gS-Apa-93 23:46 u

INIT!AL-42-19Y dM2 1

05-APR-93 21:48 M

fd 0

400 000 1200 1600 2000 FREQUENCY IN HZ SPC68.62613 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

710 GPM-A2-19V PUMP OUTBD VERTICAL Date/ Time:

06-APR-93 02:37:04 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.48

.0284

.37 13 221.69

.0034 2.76 2

44.07

.0032

.55 24 264.18

.0036 3.28 3

59.02

.0181

.73 15 31.0.88

.0034 3.86 4

73.39

.0277

.91 16 316.06

.0039 3.93 5

80.60

.0261 1.00 17 322.98

.0062 4.01 6

88.12

.0337 1.10 18 473.78

.0032 5.89 7

102.87

.0042 1.28 19 484.07

.0036 6.02 8

118.07

.0453 1.47 20 645.46

.0032 8.02 9

131.43

.0123 1.63 21 707.97

.0034 8.80 10 146.76

.0336 1.82 22 968.48

.0032 12.04 11 161.47

.0308 2.01 23 1452.92

.0207 18.06 12 176.50

.0042 2.19 24 1937.15

.0048 24.07 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0973

.0405

/ 17%

.0419

/ 18%

.0780

/ 64%

Fl/ Enter = Accept F2= Paging is ON F7= Title F9= Copy Esc = Quit 1

l

aux!LIARY BUILDING CPECTRA FROM MORE THM ONE MACH!rt n

1-m _ o

?te GPM-A2-20H I-m-anm----

o0-m 06-APR-93 8233?

a u

PLOT SPM 700 GPM-A2-20H I

06-APR-93 00838 g

0.14 <

5 a

69e GPn-A2-2eH g

.J I-06-APR-93 00430 b

i 680 GPM-42-20H h

el L J - __ -_ i-06-APR-93 00811 2

675 GP M -20H yJ f-05-APR-93 23344 3

INITIAL-A2-20H t

]

I 05-APR-93 21s49 i

$E l 0

0 400 800 1200 1600 2000 FREQUENCY IN HZ

$PC61.06901 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

710 GPM-A2-20H PUMP OUTBOARD HORIZONTAL Date/ Time:

06-APR-93 02:37:19 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.50

.0043

.37 13 190.88

.0065 2.37 2

58.90

.0037

.73 14 308.35

.0034 3.83 3

73.03

.0035

.91 15 322.90

.0031 4.01 4

80.75

.0690 1.00 16 396.49

.0042 4.93 5

98.08

.0102 1.22 17 410.94

.0035 5.11 6

106.27

.0075 1.32 18 478.35

.0053 5.94 7

118.07

.0093 1.47 19 484.34

.0236 6.02 8

131.61

.0056 1.64 20 556.98

.0034 6.92 9

141.11

.0060 1.75 21 707.74

.0051 8.80 10 146.67

.0248 1.82 22 968.65

.0036 12.04 11 161.44

.0380 2.01 23 1452.94

.0046 18.06 12 176.19

.0038 2.19 24 1533.73

.0059 19.06 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0931

.0099

/

1%

.0824

/ 78%

.0423

/ 21%

F1/ Enter = Accept F2= Paging is ON F7= Title F9= Copy Esc = Quit

l AUX!LIARY BUILDING SPECTRA FROM MORE THAN ONE MACHINE n

710 GPM-A2-21A o-m m,mmm n-,._-,Hm-mmmo M-APR-93 02:37 u

PLOT

$ PAN 700 GPM-A2-214 g

0. 20 <

.L -

% -APR-93 00:39 i

b 690 GPM-A2-21A

.L

%-APR-93 00031 h

680 GPM-A2-21A 0,

,L g.gpg.93 00 12 y

675 GPM-A2-21A

.l-OS-APR-93 23 47 I

l INIT!AL-A2-21A

.i-1 05-APR-93 21s49 2

I F

0 400 800 1200 1600 2000 OR FREQWNCY IN HZ SPC64.0bi62 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

710 GPM-A2-21A PUMP OUTBOARD AXIAL Date/ Time:

06-APR-93 02:37:35 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.48

.0127

.37 13 466.23

.0028 5.79 2

59.02

.0077

.73 14 473.46

.0045 5.88 3

73.44

.0051

.91 15 484.22

.0113 6.02 4

80.73

.0316 1.00-16 707.87

.0033 8.80 5

88,19

.0105 1.10 17 726.57

.0035 9.03 6

116.97

.0079 1.45 18 806.98

.0026 10.03 7

131.89

.0031 1.64 19 968.58

.0053 12.04 8

146.92

.0067 1.83 20 1452.88

.1225 18.06 4

161.47

.0154 2.01 21 1533.63

.0066 19.06 10 176.90

.0037 2.20 22 1775.82

.0033 22.07 11 316.11

.0038 3.93 23 1856.14

.0048 23.07 12 321.64

.0033 4.00 24 1937.17

.0119 24.07 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.1337 0224

/

3%

.0546

/ 17%

.1200

/ 81%

F1/ Enter = Accept F2= Paging is ON F7= Title F9= Copy Esc = Quit

Aux 1LIARY BUILDING SPECTRA FROM MORE THAN ONE MACHINE Y

710 GPM-A2-26V

--_a 06-APR-93 82837 o

PLOT d

SPAN 700 GPM-A2-26V g

0.12 -

06-APR-93 00:39 AP 9 31 0

06 9

12 APR 47 J

R9 49 MI 1000 2000 3000 4000 5000

-6000 O

FREQUENCY IN HZ SPC6

.04936 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

710 GPM-A2-26V PIPING HIGH FREQ Date/ Time:

06-APR-93 02:37:57 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

1462.88

.0494 18.06 13 2581.14

.0090 32.08 2

1537.50

.0041 19.11 14 2642.84

.0076 32.84 3

1613.31

.0057 20.05 15 2744.63

.0137 34.11 4

1690.12

.0049 21.00 16 2902.85

.0077 36.08 5

1779.23

.0126 22.11 17 2992.25

.0040 37.19 6

1864.34

.0102 23.17 18 3111.66

.0028 38.67 7

1959.89

.0163 24.36 19 3234.63

.0023 40.20 8

2091.41

.0584 25.99 20 3635.33

.0015 45.18 9

2167.11

.0372 26.93 21 3793.47

.0015 47.14 10 2262.28

.0204 28.11 22 3870.79

.0028 48,10 11 2422.05

.0275 30.10 23 4042.72

.0013 50.24 12 2508.30

.0062 31.17 24 4129.09

.0015 51.31 TOTAL MAG SUBSYNCHRONOUS 8VNCHRONOUS NONSYNCHRONOUS

.1124 Undefined / '0%

Undefined /

0%

Undefined /

0%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

CHRG - CHARG. PUMP A INIT!AL-Al-1V MOTOR OUTBOARD VCRTICAL g g 0$-APR-93 21:36

0. _.

L,en.. in':

=

1?s4.

ug RPS. 29.40 j

0. _.

i t

n

$ 0.004,,o 5

8 E

0.082,

9 (k Yak YE9 no-c',

=

=

FREQUCNCY IN HZ SPEC 3

.00414 s

LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Initial-Al-1V MOTOR OUTBOARD VERTICAL Date/ Time:

05-APR-93 21:36:12 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.51

.0046 1.00 13 206.73

.0015

.7,03 2

59.09

.0025 2.01 14 208.44

.0017 7.09 3

59.51

.0006 2.36 15 239.29

.0006 8.14 4

73.13

.0006 2.49 16 323.20

.0014 10.99 5

80.86

.0009 2.75 17 354.04

.0026 12.04 6

83.35

.0007 2.84 18 359.94

.0032 12.24 7

88.48

.0058 3.01 19 413.03

.0010 14.05 8

94.56

.0005 3.22 20 442.60

.0011 15.06 9

119.75

.0072 4.07 21 471.92

.0007 16.05 10 147.45

.0029 5.02 22 484.36

.0009 16.48 11 161.76

.0007 5.50 23 648.94

.0006 22.08 l

12 178.44

.0019 6.07 24 707.92

.0011 24.08 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0134

.0017

/

2%

.0101

/ 57%

.0086

/ 41%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy

. Esc = Quit l

i

'I

~

CM G - CHARG. PUMP A IMITIAL-Al-2H MOTOR OUTBOARD HORIZONTAL 0.012 i

SPECTRUM DISPLAY 05-APR-93 21836 0.010.

3-PK e

.0161 LOAD = 100.0 R: re:a

+10.000 3

n

~' O.006

  • g 9

5 J

g 0.00<.

a r

f 0.002,

n n

n n

PJ m90 0

0 200

<80 600 000 1000 FREQUENCY IN HZ SPECS.00690 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Initial-Al-2H MOTOR OUTBOARD HORIZONTAL Date/ Tile:

05-APR-93 21:36:48 Amplitude Units:

IN/SEC PK l

PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY

. PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE.

VALUE 1

29.50

.0077 1.00 13 235.99

.0015-i8.03 i

2 45.74

.0010 1.56 14 240.04

.0046 8.17 3

50.43

.0009 1.72 15 265.47

.0009 9.03.

4 53.37

.0006 1.82 16 294.99

.0012 10.04-5 58.99

.0093 2.01 17 324.36

.0013-11.03 6

.69.23

.0010 2.35 18 353.94

.0027 12.04 7

74.44

.0008 2.53 19 359.97

.0053 12.25 8

88.50

.0022 3.01 20 383.48

.0015 13.05-9 119.42

.0024 4.06 21 531.00

.0009 18.06 10 149.53

.0007 5.09 22 560.47

.0009 19.07 11 179.39

.0009 6.10 23 589.90

.0006

-20.07 12 206.47

.0021 7.02 24 707.99

.0024 24.08-TOTAL MAG SUBSYNCHRONOUS

. SYNCHRONOUS NONSYNCHRONOUS

.0161

.0017

/

1%

.3132

/ 68%

.0090

/ 31%.

F1/ Enter = Accept F2= Paging is OFF

.F7= Title

'F9= Copy

Esc = Quit

8 h

?

4

e CHRG - CHARG. PUMP A INIT! L-Ai-3A MOTOR OUTDOARD Ax!AL Om 05-APR-93 21:37 L. in'.*.

e9 0.0 6

,Pn. 17 m

s

.rs e. 0 sy

_n n

5 e.e84 g

5 9

9 15 n

0. 0 2.

n' n

ei g j W

h8 L

I$

((

0 200 400 600 800 1000 op FREQUENCY IN H2 SPEC 8.00261 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Initial-Al-3A MOTOR OUTBOARD AXIAL Date/ Time:

05-APR-93 21:37:04 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.48

.0029 1.00 13 178.00

.0059 6.06 2

59.04

.0016 2.01 14 206.42

.0029 7.02 3

80.81

.0009 2.75 15 237.03

.0011 8.06 4

88.50

.0026 3.01 16 239.46

.0009 8.15 5

95.59

.0010 3.25 17 265.59

.0017 9.03 6

118.02

.0017 4.01 18 295.37

.0010 10.05 7

119.67

.0019 4.07 19 324.61

.0023 11.04 L

147.50

.0050 5.02 20 354.12

.0026 12.05 9

153.41

.0006 5.22 21 359.86

.0014 12.24 10 156.94

.0005 5.34 22 383.36

.0013 13.04 11 161.67

.0010 5.50 23 413.02

.0007 14.05 12 168.01

.0010 5.72 24 707.97

.0006 24.08 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0130

.0040

/ 10%

.0101

/ 61%

.0071

/ 30%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

.s

)

ema - cwdG. PUMP A INITIAL-Al-4v MOTOR INBOARD VERTICAL

0. 0%

j i

05-APR-93 21:37 j

0.030 PK =

.0330 u

LOAD = 100.0 i

RPM

  • 1764

)

O RPS e 39,40 m

s

0. 010.

=

8 9

y 0.01a %g g

g a"

~

is

e. 806.

k "C#P i~

EOT inmoom-O uaJ Ih h2 0

200 400 600 800 1000 op FREQUENCY IN HZ SPECl

.006 %

LIST OF SPECTRAL PEAKS

      • w******************

Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Initial-Al-4V MOTOR INBOARD VERTICAL Date/ Time:

05-APR-93 21:37:48 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.52

.0077 1.00 13 472.01

.0032 16.06-2 59.00

.0071 2.01 14 484.46

.0018 16.48-3 88.53

.0105 3.01 15 531.08

.0031 18.07 4

119.92

.0240 4.08 16 590.13

.0013 20.08 5

149.52

.0018 5.09 17 619.59

.0012 21.08 6

179.10

.0031 6.09 18 646.87

.0017 22.01 7

208.41

.0034 7.09 19 649.08

.0040 22.08 8

324.35

.0016 11.03 20 678.58

.0020 23.08 9

354.06

.0037 12.04 21 708.08

.0099 24.09 10 359.88

.0018 12.24 22 726.71

.0017 24.72 11 383.44

.0012 13.04 23 737.60

.0020 25.09 12 413.06

.0023 14.05 24 767.10

.0014 26.10 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0330

.0031

/

1%

.0203

/ 38%

.0259

/ 62%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

I E

"CMtG - CHARG. PUPF A IMITI Al*"l*%

MOTOR INBOARD HORIZONTAL' 0.

16 SPECTRupt DJsptAy 05-APR-93 21:38 PK *.0200 o

LOAD

  • 100.0 u 9.012.,

RPM

  • 1764.

RPS

  • 29.40 5

R e.ees.

n 8

et n

Y.

g j

~

n n

1.. 4 n

J T W9 C e

i cra: ee recaucNcY IN HZ SPECS

.01 90 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Initial-Al-5H

-->. MOTOR INBOARD HORIZONTAL

.Date/ Time:

05-APR-93 21:38:16 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK

-ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE-

.VALUE 1

29.49

.0121 1.00 13 294.97

.0007 10.03 2

50.66

.0009 1.72 14 323.16

.0023 10.99' 3

58.96

.0085 2.01 15 354.02

.0012-12.04 4

69.71

.0009 2.37 16 360.01

.0025

'12.25 5

80.74

.0008 2.75 17 383.50

.0045 13.05' 6

88.50

.0046 3.01 18 442.59

.0012 15.06 7

119.76

.0055 4.07

.19 471.98

. 0016'-

16.06 8

147.47

.0030 5.02-20 484'.50

.0008 16.48 9

161.47

.0013 5.49 21 531.00

.0018

--18.06 10.

177.05

.0020 6.02 22 589.96

.0015

'20.07 11 206.45

.0043 7.02 23 649.05

.0007-22.08 12 239.84

.0023 8.16 24 708.00

.0021 24.09' TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS.

NONSYNCHRONOUS

.0200

.0026

/

2%

.0177

/ 79%

.0088

/(20%

F1/ Enter = Accept F2= Paging is OFF F7= Title' F9= Copy.

Esc = Quit

CHRG - CHARG. PUMP A INITIAL-et-6A MOTOR IN8oARD AXTAL 05-ArR-93 21830 e

e.e m B

io'.d' M

Os'. ?e o

b

e. eta.

5 o

h e.eee. Y Y

f h r

a e.ee4 Q

f

<Wo o

A

_LvP AN oa -

e r$**ucncy E

[c!.

LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Initial-Al-6A MOTOR INBOARD AXIAL Date/ Time:

05-APR-93 21:38:48 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.48

.0025 1.00 13 178.38

.0035 6.07 2

58.97

.0050 2.01 14 238.08

.0012 8.10 3

80.86

.0015 2.75 15 354.02

.0019 12.04 4

88.51

.0079 3.01 16 359.88

.0012 12.24 5

95.69

.0014 3.26 17 383.43

.0019 13.04 6

98.26

.0010 3.34 18 471.94

.0032 16.05 7

120.00

.0150 4.08 19 484.32

.0010 16.48 8

149.40

.0054 5.08 20 530.90

.0021 18.06 9

161.48

.0022 5.49 21 560.39

.0022 19.06 10 166.65

.0017 5.67 22 565.09

.0011 19.22 11 170.37

.0019 5.80 23 589.80

.0014 20.06 12 174.35

.0011 5.93 24 707.91

.0039 24.08 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0218

.0023

/

1%

.0135

/ 38%

.0170

/ 61%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

CMiG - CHARG. PUMP A

!MITTAL-Al-7v GEAApox tNPUT VERf! CAL 6.812 i

SPECTRUM D!$ PLAY 05-APR-93 21:39 0.010,

PK =.6126 o

LOAD = 10e.0 u

4 RPM

  • 1768.

RPS = 29.46 m

N

~

$ e.ee6. {

8 y e.w4 g

g S

8 e.ee2 n.

e M

3 T* A L

F $l f'g*

j S

e se see ise eee 25e see 3se 4ee FREQUENCY IN HZ gpggg

,gg495 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Initial-Al-7V GEARBOX INPUT VERTICAL Date/ Time:

05-APR-93 21:39:28 Amplitude Units:

IN/SEC. PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

5.80

.0012

.20 13 177.00

.0007 6.01 2

8.83

.0008

.30 14 220.24 3.65E-04 7.47 3

29.50

.0050 1.00 15 236.00

.0005 8.01 4

58.98

.0012 2.00 16 265.50

.0011 9.01

)

5 80.74

.0023 2.74 17 293.59 4.66E-04 9.96 6

88.46 3.83E-04 3.00 18 295.02

.0013 10.01 7

110.24

.0012 3.74 19 300.96 3.86E-04 10.21 l

8 118.01

.0005 4.01 20 322.95

.0057 10.96 9

120.00

.0028 4.07 21 324.52

.0018 11.01 10 147.28

.0006 5.00 22 354 01

.0078 12.01 11 149.52 4.56E-04 5.07 23 360.02

.0008 12.22 12 161.48

.0018 5.48 24 383.52

.0020 13.02 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0126

.0019

/

2%

.0094

/ 55%

.0082

/ 42%

F1/ Enter = Accept' F2= Paging is OFF F7= Title F9= Copy

. Esc = Quit

1 CHRG - CHARG. PUMP A IN:TIAL-A1-OH CEARBOX 1NPUT HOR 120NTAL 0*012 i

SPECTRUM DISPLAY 05-APR-93 21:39 0.010.

PK =

.0100 98 LOAD = 100.0 g

RPM = 1768.

y RPS = 29.46 lI 5

s s

0.006.] g d

8 y 0.004 s

8.0e2.

n o

n nn b

-i? >l 5

A d' s

8

((

((

O 50 100 150 200 250 300 350 400 r

FREQUENCY IN H2 SPECS.00547 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Initial-Al-8H GEARBOX INPUT HORIZONTAL Date/ Time:

05-APR-93 21:39:52 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

5.33

.0057

.18 13 177.02

.0081 6.01 2

7.19

.0018

.24 14 178.98

.0010 6.07 3

29.51

.0055 1.00 15 206.53

.0015

.7.01 4

59.01

.0018 2.00 16 236.00

.0009 8.01 5

80.74

.0062 2.74 17 242.25

.0015 8.22 6

110.27

.0007 3.74 18 265.54

.0014 9.01 7

118.01

.0030 4.01 19 295.06

.0013 10.01 8

120.00

.0010 4.07 20 322.99

.0018 10.96 9

132.12

.0007 4.48 21 354.07

.0018 12.02 10 147.21

.0021 5.00 22 360.10

.0014 12.22 11 149.53

.0014 5.07 23 375.69

.0006 12.75 12 161.50

.0080 5.48 24 383.56

.0052 13.02 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0180

.0062

/ 12%

.0120

/ 44%

.0120

/ 44%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

CHRG ~

iMITif4 -*I'9" dgox

  1. I#

0.016 6

SPECTRUM DISPLA O p.93 218 c.

~.

01,2 s

2"/!**'e m

0. 0i2.

}.

p RPS = 29.46 E

N r

[ 0.908

,o.

2 A

8 b

E' n

d s

g 0.004 b

O t J

a La 1 s t l' D 11 =

[$l f[

0 50 100 150 200 250 300 350 400 FREQUENCY IN HZ SPECL.01160 LIST OF SPECTRAL PEAKS

                    • w***********

Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Initial-Al-9A GEARBOX INPUT AXIAL Date/ Time:

05-APR-93 21:40:36 Amplitude Units:

IN/SEC PK l

PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.50

.0116 1.00 13 177.03

.0016 6.01 2

51.25

.0012 1.74 14 191.05

.0008 6.48 3

59.01

.0054 2.00 15 236.03

.0010 8.01 4

80.75

.0099 2.74 16 242.26

.0012 8.22 5

88.53

.0018 3.00 17 265.56

.0013 9.01-6 110.26

.0042 3.74 18 295.04

.0014 10.01 7

118.03

.0013 4.01 19 323.00

.0015 10.96

{

8 120.02

.0025 4.07 20 324.54

.0008 11.01 9

139.76

.0008 4.74 21 354.07

.0016 12.02 l

10 147.15

.0010 4.99 22 360.08

.0014 12.22 11 149.52

.0006 5.07 23 381.73

.0009 12.96 12 161.51

.0024 5.48 24 383.56

.0058 13.02 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS l

.0192

.0012

/

0%

.0143

/ 55%

.0128

/ 44%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit.

+'

I CHRG - CHARG. PUMP A INITIAL-Al-10V GEARBOX OIL P/P VERTICAL 0.024 SPECTRUM DISPLAY 05-APR-93 21:41 e

PK =.0424 W / M,.a.*

i o 0.Bie.

e y

g

.Ps., 6 s

E

, 0.0:a.

9 8

8 d

A d

I y e.006 1 b

M i

a e

0 1000 2000 3000 4000 FREQUDCY IN HZ 4

LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Initial-Al-10V GEARBOX OIL P/P VERTICAL Date/ Time:

05-APR-93 21:41:12 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.40

.0053 1.00 13 1938.96

.0049 65.81.

2 323.32

.0066 10.97 14 2019.00

.0043 68.52.

3 354.01

.0179 12.01 15 2242.43

.0042 76.11 4

484.88

.0039 16.46 16 2360.74

.0039

'80.12 5

708.17

.0096 24.03 17 2980.22

.0088 101.15 6

1416.49

.0059 48.07 18 3009.71

.0075 102.15 7

1452.40

.0037 49.29 19 3039.12

.0080 103.14 8

1475.45

.0070 50.08 20 3068.64

.0152 104.15 9

1563.90

.0040 53.08 21 3098.18

.0129 105.15 10 1622.73

.0051 55.07 22 3127.78

.0041 106.15 11 1710.80

.0041 58.06 23 3186.47

.0037

'108.15 12 1917.14

.0047 65.07 24 3216.22

.0039 109.16 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS.

.0424 Undefined /

0%

.0405

/ 91%

.0125

/

9%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit i

1

[

CHRG - CHARG. PUMP A INtT!AL-Al-11H GEARBOX 0!L P/P HORIZONTAL OS-APR-93 21:41 L.1:

0.024 O

o

_. i m.

p g

g RPS e 29.46

[

l 5

e.0:e.

E m

E 8 0.012.

d I

E O. _,,

N ', _

i>

A 8

^

=

29 2_

_0 FREQUENCY IN HZ

$PEC:.00199 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Initial-Al-11H GEARBCX OIL P/P' HORIZONTAL Date/ Time:

05-APR-93 21:41:32 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER No.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.60

.0058 2.74 13 1564.46

.0035 53.10 2

176.93

.0050 6.00 14 1622.57

.0046 55.07' 3

354.80

.0067 12.04 15 1938.37

.0036-65.79-4 384.32

.0076 13.04 16 2891.62

.0043 98.14 5

471.72

.0050 16.01 17 2920.92

.0045 99.13 6

678.53

.0044 23.03 18 2950.40

.0052 100.13' 7

708.12

.0196 24.03 19 2980.00

.0148 101.14 8

735.05

.0045 24.95 20 3009.64

.0107 102.14 9

1150.60

.0034 39.05 21 3038.94

.0116 103.14 10 1180.00

.0049 40.05 22 3068.47

.0171 104.14 11 1454.21

.0036 49.35 23' 3097.95

.0117

.105.14~

12 1475.68

.0032 50.08 24

'3216.03

.0035 109.15 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0448 Undefined /

0%

.0428

/ 91%

.0131- /

9%.

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit.-

CHRG - CHARG. Pt,MP A

!N17!AL-Al-12A GErdBOX OIL P/P Ax!AL 0.00

I-SPECTRUM DISPLAY 05-APR 21:41 ex.. On, N

WR 1%*

a.. u.

RPS = 29.46:

S e.es.

E e.04 8 e.as.

Y(..23 C

0.81.

e IM A

L l

0 1000 2000

. 3000 4000 FREQUENCY IN HZ SPEC 8.00730 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Initial-Al-12A. -->

GEARBOX OIL P/P AXIAL Date/ Time:

05-APR-93

'21:41:56 Amplitude Units:

IN/SEC. PK-PEAK FREQUENCY PEAK ORDER PEAK-FREQUENCY.

PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE

'VALUE

.1 -

29."O

.0126 1.00 13

'649.19

.0106 22'.03.

2 59.19

.0050 2.01 14 678.77

.0099 23.04 3

80.56

.0085 2.73 15 708.07

.0612.

24.03-4 115.03

.0053 3.90 16 726.71

.0096 24.66 5

323.04

.0049 10.96 17 735.96

.0098' 24.98 6

353.66

.0117 12.00 18 1453.66

.0053-

'49.34 7

382.40

.0065 12.98 19 1475.00

'0055 50'.06 8

413.19

.0056 14.02 20-1563.56

.0051

,53.07:

9 472.29

.0060 16.03 21 1622.19

.0051 55.06 10 502.54

.0070 17.06' 22 1681.69

.0047 57.08 11 530.66

.0066 18.01 23 3068.82

.0073 104.15' 12 619.65

.0072 21.03 24 3098.35

.0066 105.16 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS-

.0739 Undefined /.

0%

.0720 -/ 95%

.0166

/- 5%

F1/ Enter = Accept-F2= Paging is OFF F7= Title F9= Copy Esc = Quit.

t t

b e-e, a

e-i-%

.=-

m w

t

CHRG - CHARG. PUNP A fN!TIAL-41-13V GEARBOX OUTPUT VERTICAL

0. 0%

3 05-APR-93 21:42 0.030 PK e

.0414 LOAD = 100.0 h

.024,

7 0

g E

0.e18.

g k

5 N

h 0.012,

f f

0.006 o

l 0 (19 d.

!$1 M i MM

[jl 80 0

400 000 1200 1600 2000 FREQUENCY IN H2 SPECS.05302 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Initial-Al-13V GEARBOX OUTPUT VERTICAL Date/ Time:

05-APR-93 21:42:28 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.49

.0043

.37 13 708.14

.0136 8.80 2

80.78

.0032 1.00 14 726.76

.0031 9.03 3

323.21

.0100 4.02 15 737.66

.0034 9.17 4

354.07

.0267 4.40 16 1180.20

.0043 14.67 5

383.49

.7046 4.77 17 1386.75 0033 17.23 6

413.05

.0074 5.13 18 1416.28

.0037 17.60 7

442.59

.0036 5.50 19 1453.50

.0077 18.06 8

472.14

.0089 5.87 20 1534.28

.0028 19.07 9

531.03

.0058 6.60 21 1563.80

.0043 19.43 10 565.37

.0035 7.03 22 1593.17

.0034 19.80 11 648.62

.0036 8.06 23 1622.79

.0031 20.17 12 678.67

.0041 8.43 24 1711.36

.0050 21.27 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0414

.0086

/

4%

.0134

/ 11%

.0382

/ 85%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit l

m

1 CHRG - CHARG. PUMP A INIT!AL-Al-14H GEAEBOX OUTPUT HORI2ONTAL I

SPECTRUM DISPLAY 05-APR-93 21:42 7

PK *.0430

?

W: #*

. 03.

v p

RPS = 80.47 s

s 0.02 5

Y E

e r

0.01..

{

@T i]3 Ri II9hanT4 I W E T-e Ih '

.80 0

400 800 1200 1600 2000 FREQUENCY IN HZ SPEC 8 00567 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Initial-Al-14H GEARBOX OUTPUT HORIZONTAL Date/ Time:

05-APR-93 21:42:44 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

59.01

.0034

.73 13 678.66

.0056 8.43 2

80.79

.0060 1.00 14 708.13

.0300 8.80 3

147.92

.0020 1.84 15 726.71

.0047 9.03 4

177.01

.0046 2.20 16 737.58

.0056 9.17 5

295.18

.0020 3.67 17 796.62

.0022 9.90 6

323.93

.0028 4.03 18 1416.22

.0020 17.60 7

354.00

.0099 4.40 19 1453.49

.0023 18.06 8

383.71

.0055 4.77 20 1475.23

.0047 18.33 9

413.28

.0037 5.14 21 1504.79

.0022 18.70 10 472.34

.0034 5.07 22 1534.12

.0032 19.06 11 484.68

.0028 6.02 23 1593.33

.0029 19.80 12 648.42

.0040 8.06 24 1622.73

.0030 20.16 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0430

.0207

/ 23%

.0103

/

6%

.0363

/ 71%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit l

i

~

CteG - CHARG. PUMP A IMITI Al-Al-!%

GCARBOX OUTPUT AXIAL g

05-APR-93 als43 1'

PK =.0921 0.00.

g LOAD = 100.0

$$ l N'D 0.06,

5 g e.e4 Y

,S

  1. 0.0aDi i

O

d kE I

>=8'kIII E #k:SE M

80 00 0

400 000 1290 1600 2000 FREQUDiCY IN H2 SPEC 4.00006 i

LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Initial-Al-15A' -->

GEARBOX OUTPUT AXIAL Date/ Time: APR-93 21:43:04 Amplitude Units:

IN/SEC' PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE:

l'-

29.52-

.0177

.37 13

'726.75

.0113

'9.03 2

'59.01

.0182

.73 14 737.61

.0219-

-9.17 3

80.75

.0086 1.00 15 796.62

.0089 9.90 4

88.54

.0059 1.10 16 969.00

.0046 12.04:

-5 110,29

.0050 1.37 17 1180.17

.0073

.14.67 6

383.65

.0053 4.77 18 1416.22:

.0056 17.60 7

565.16

.0066 7.02 19 1445.73

.0061

-17.96-8 590.02

.0050 7.33 20 1453.44

.0076 18.06 9

619.62

.0117.

7.70 21 1475.15

.0090 18.33 10 648.85

.0148 8.06 22 1504.70-

.0059 18.70 11 678.60

.0123 8.43 23 1711.22

.0092 21.26 12

'708.11

.0740 8.80 24-1888.25

.0047 23.46 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0921

.0257' /

8%

.0217' /

6%.

.0857

/.87%.

F1/ Enter = Accept F2= Paging'is OFF F7= Title F9= Copy--

Esc = Quit

a C Wa - OGRG. PUMP A IN!T!AL-Al-16V PUMP INBD VERTICAL 0*

05-APR-93 21:43 MD=500 u

0.03.,h RPM e 4829.

RPS = 80.47 s

E

0. 0a.

9 W

4 i

g 0.01,

d 0

L Wmann-9mmno 80s 0

400 800 1200 1600 2000 FREQT NCY IN HZ SPECS.02634 LIST OF SPECTRAL PEAKS

(

Machine:

(CHRG) CHARG. PUMP A

)

Meas. Point:

Initial-Al-16V PUMP INBD VERTICAL Date/ Time:

05-APR-93 21:43:24 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.75

.0279 1.00 13 313.06

.0030 3.89 2

117.99

.0033 1.47 14 321.51

.0035 4.00 3

131.88

.0031 1.64 15 404.23

.0023 5.02 4

147.02

.0030 1.83 16 471.75

.0022 5.86 5

161.47

.0133 2.01 17 484.53

.0117 6.02 6

176.72

.0023 2.20 18 645.84

.0031 8.03 7

198.64

.0027 2.47 19 783.29

.0038 9.73 8

206.50

.0045 2.57 20 803.68

.0025 9.99 9

221.32

.0130 2.75 21 808.28

.0044 10.04 10 242.26

.0045 3.01 22 1372.75

.0039 17.06 11 265.56

.0022 3.30 23 1453.47

.0066 18.06 12 308.63

.0023 3.84 24 1937.85

.0027 24.08 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0444

.0025

/

0%

.0340

/ 58%

.0285

/ 41%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit i

CHRG - CHARG. POMP A IMIT!AL-Al-t?H P W INBD hop!20NTAL g, g 05-APR-93 21343 0.07

.N PK =.0799 LOAD = 100.0 o

0.06 RPM = 4829.

RPS = 80.47 0.05,

E 0.04 c

0.03,

! * $2 -d 2

si 0.01.

n o

0

  1. bi no-mm

'P i-c o t

$8 80 0

400 800 1290 1600 2000 FREGRENCY IN H2 SPEC

.05957 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Initial-Al-17H PUMP INBD HORIZONTAL Date/ Time:

05-APR-93 21:43:40 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.73

.0630 1.00 13 234.79

.0072 2.92 2

126.01

.0032 1.57 14 242.26

.0096 3.01 3

132.06

.0092 1.64 15 249.38

.0059 3.10 4

140.64

.0054 1.75 16 323.11

.0046 4.01 5

147.20

.0110 1.83 17 383.28

.0038 4.76 6

161.49

.0285 2.01 18 403.68

.0038 5.02 7

190.87

.0079 2.37 19 471.67

.0034 5.86 8

198.80

.0040 2.47 20 484.46

.0124 6.02-9 206.31

.0063 2.56 21 645.96

.0077 8.03 10 216.42

.0044 2.69 22 708.03

.0045 8.80 11 221.56

.0044 2.75 23 1372.62

.0093 17.06 12 228.22

.0042 2.84 24 1453.35

.0118 18.06 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0799

.0115

/

2%

.0714

/ 80%

.0339

/ 18%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit l

i 1

CHRG - CHARG. PUMP A INITIAL-Al-18A PUMP IN3D AXIAL gg 05-APR-93 21 44 0.029.

PK =

.0502 o

LOAD = 100.0 y0.0i.

i s

  • : :: b y

g I

e

[ 0.012.

n g 0.000 E

9.084 n

I G

e 80 0

400 000 1200 1600 2000 FREQUCNCY IN H2 SPEC 1.01312 -

LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A.

Meas. Point:. Initial-Al-18A PUMP INBD AXIAL Date/ Time:

05-APR-93 21:44:12 Amplitude Units:

IN/SEC 'PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

_VALUE VALUE

'NO.

(Hz)

VALUE VALUE i

1 80.73

.0139

.1.00 13 1588.89

.0047-19.74 2

132.04

.0038 1.64. 1615.48

.0062 20.07 3

146.93

.0150 1.83 15 1649.00

.0042 20.49 4

161.47.

.0176 2.01 16 1686.46

.0053

'20.96 5

484.08

.0039 6.02 17 1698.65

.0066 21.11 6

726.58

.0045.

9.03 18 1714.08

.0044 21.30 7

1372.56

.0151 17.06 19 1723.37

.0044 21.41 8

1453.33

.0137 18.06 20 1743.39

.0044 21.66 9

1534.06

.0106 19.06 21 1746.33

.0040 21.70 10 1566.34

.0037 19.46 22 1776.60

.0039 22.08.

11 1575.75

.0038 19.58 23 1857.01

.0043 23.08 12 1583.35

.0041 19.68 24 1937.71

.0104 24.08 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0502

.0080

/

3%

.0270

/ '29%

.0416

/.69%'

F1/ Enter = Accept' F2= Paging is OFF F7= Title F9= Copy Esc = Quit' 1

CHRG - CHARG. PUMP A IN!T!c(-Al-19v PUMP OUTBD VESTICAL OE 05-APR-93 21:44 0.04 70Ao".1e00 88 g

a

": ::'n 0.03,,

s I

ci'

?"

y 0.e2,

Y 0.01.

O t WDJ n?"m Di

- 9 T I

F 0

400 800 1200 1600 2000 OR i

FREQUENCY IN H2 SPEC

.02799 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Initial-Al-19V PUMP OUTBD VERTICAL Date/ Time:

05-APR-93 21:44:32 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER No.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.46

.0189

.37 13 161.52

.0316 2.01 2

43.54

.0028

.54 14 219.16

.0035 2.72 3

51.09

.0026

.63 15 228.47

.0036 2.84 4

58.98

.0200

.73 16 234.33

.0047 2.91 5

73.37

.0215

.91 17 242.84

.0033 3.02 6

80.75

.0297 1.00 18 323.01

.0082 4.01 7

88.19

.0354 1.10 19 471.25

.0028 5.86 8

102.42

.0061 1.27 20 484.59

.0115 6.02 9

117.93

.0341 1.47 21 646.12

.0032 8.03 10 126.22

.0063 1.57 22 707.08

.0029 8.79 11 131.95

.0236 1.64 23 726.76

.0031 9.03 12 146.97

.0394 1.83 24 1453.65

.0065 18.06 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0926

.0328

/ 13%

.0456

/ 24%

.0736

/ 63%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

m.

i-CHRG - CHARG. PUMP A -

INITTAL-Al-20H PUPP OUTBOARD HORIZONTAL 0.00 i

SPCCTRUM DISPLAY 05-APR-93 21144 0.07 m 9 PK =-.9943 LOAD = 100.0 o

0.06 m,,

RPM = 4929.

y RPS = 80.47 h

8.05,

z 0.04,

h

_n 8-0.03 d

y 4

r 0.02 e

n

+

0.01,

8

  • M Y""---"'cT 0'

400 000 1200 1680 2000

~ 00 4

FREQUENCY IN H2

$PCCI.05970 a

LIST OF-SPECTRAL PEAKS.

Machine:

(CHRG) CHARG. PUMP A-Meas. Point:

Initial-Al-20H PUMP OUTBOARD HORIZONTAL Date/ Time:-

05-APR-93 21:44:52 Amplitude Units:

IN/SEC 'PK

- PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

.(Hz)

VALUE VALUE 1

58.95

.0032

.73 13-242.02

.0044 3.01 2-80.77

.0635 1.00 14 322.98

.0055

'4.01 3

86.37

.0078 1.07 15 440.39

.0027 5.47 4

96.71

.0114 1.20 16 484.24

. 0182 6.02 5

103.14

.0055 1.28 17 543.34

.0034 6.75 6

117.84

.0058 1.46 18 550.99

.0034 6.85 7

121.36

.0042 1.51 19 646.14

.0042 8.03-

.8 132.14

.0236 1.64 20 708.09

.0050 8.80 9

146.92

.0370 1.83 21 726.64

.0033 9.03 10 161.43

. 0408 2.01 22 807.44

.0026 10.03 11 168.88

.0025 2.10 23 1453.40.

.0047-18.06 12 205.63

.0032 2.56 24 1534.08

.0055 19.06 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0943

.0074

/- 1%

.0780

/ 68%

.0524 -/ 31%

F1/ Enter = Accept' F2= Paging is OFF F7= Title F9= Copy Esc = Quit' r

-. +.,

m.

~,

._c o CHRG - CHARG. PUNP A

'! NIT!AL-Al-21A PUPP OUTBOARD Ax!AL g,3, 05-APR-93 21:45 PM =

.0907 0.06.

Q LOAD = 100.0 u

v RPM = 4829.

RPS e.80.47 5

e. 86.

.5 b

E e.e4 a p'

8'n w

g 0.02,, <!d 3

lC E

0

  • b IEb 9-~~~c O-"

F 00 00 g j'.02879 e

400 000 1200 -

1686 2000 g94 FREQUENCY IN H2 SPEC 8 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP-A Meas. Point:

Initial-Al-21A PUMP OUTBOARD AXIAL-Date/ Time:

05-APR-93 21:45:12 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK

' ORDER PEAK FREQUENCY-PEAK ORDER-NO.

(Hz)

VALUE VALUE NO.

(Hz).

VALUE.

VALUE.

1 29.54

.0097

.37 13 322.99

. 0045.

4.'01 2

59.03

.0079

.73 14 330.58~'

.0022-

'4.11 3

73.47

.0046-

.91 15-463.27.

.0026

'5.76 4

80.75

.0305 1.00 16 471.71

.0050 5.86

~

5 88.32

.0105 1.10 17

'484.36

.0136 6.02 6

103.33

.0025 1.28 18 501.30

.0024 6.23' 7

111.18

.0061 1.38 19 646.22

.0052 8.03 8

116.95

.0080 1.45 20 708.11

.0024' 8.80 9

132.02

.0061 1.64 21 726.64

.0028 9.03 10 147.02

.0067 1.83 22 1453.50'

.0765 18.06 11 161.47

.0137 2.01 23 1534.30

.0072 19.07 12 177.01

.0036 2.20 24 1938.26

.0071-24.09 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0907

.0152

/

3%

.0399

/ 19%

.0801

/-78%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit 1

=

f) j e.

s CHRG - CMARG. PUMP A INIT!4L-Al-22V OIL PUNP VERTICAL 05-APR-93 21:45 i

L. i:28;

.. 4 8

u RPM e 4829.

g RPS e 80.47 h

e.es,. *. ' '

5 R

i E

~

n g e.sa.

Y l

0.01, 1

m m c - - e, 9

om 9T g

I 88 %

0 400 800 1290 1600 2000 FREQUENCY IN H2 SPEC 8.91009 j

LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Initial-Al-22V OIL PUMP VERTICAL Date/ Time:

05-APR-93 21:45:52 Amplitude Units:

IN/SEC PK PEAK FREQUENCY-PEAK ORDER PEAK FREQUENCY PEAK-ORDER:

NO.

(Hz)

VALUE VALUE NO.

(Hz).

VALUE VALUE 1

29.53

.0191

.37 13 228.45

.0041 2.84 2

59.02

.0191

.73 14 234.00

.0052 2.91 3

73.37

.0276

.91 15 278.95

.0054 3.47 4

80.79

.0193 1.00 16 293.64

.0098 3.65 5

88.21

.0341 1.10 17 300.63

.0070~

3.74 6

103.49

.0092 1.29 18 308.33

.0188 3.83 7

118.01

.0358 1.47 19 323.35

.0245

4.02 8

123.99

.0058 1.54 20 329.15

.0058 4.09' 9

131.95

.0190 1.64 21

-381.87

.0051 4.75 10 146.85

.0332 1.82 22 483.71

.0079 6.01 11 161.50

.0344 2.01 23 646.15

.0059 8.03 12 220.33

.0069 2.74 24 1453.57

.0066

-18.06 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS.

.0984

.0351

/ 13%

.0482

/ 24%

.0782'./ 63%

'F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit 4

5 i

- ~ -

l 1

CHRG - CHARG, PUMP A IMITIAL-Al-23H O!L PUNP HORI20NTAL

'. e%

e 4

SPECTRUM D!$ PLAY e5-APR-93 211 %

.)

e.eM.

PK =

.eS47 2"/ m;'

a

~

ge.e,4 {i ae$ - a *'

5 to e.ete.

g g

g j

Q.

[=

2 1

y

e. eta'.

n e.ees.

M

'L e

.2 me~m-e

~I F Ejl J

8e g e

4ee see seee 16ee esee g

m outNcy IN H2 SPCCI.eE29e LIST OF SPECTRAL PEAKS 1

Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Initial-Al-23H OIL PUMP HORIZONTAL Date/ Time:

05-APR-93 21:46:20 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY-PEAK ORDER NO..

(Hz)

VALUE VALUE NO.

(Hz)

VALUE

-VALUE.

1 80.74

.0243 1.00 13 242.31

.0072-3.01" 2

88.35

.0039 1.10 14 279.24

.0046 3.47 3

96.35

.0041 1.20 15 293.73

.0091 3.65 4

103.08

.0068 1.28 16 323.09

.0096.

4.01 5

117.42

.0152 1.46 17 396.90

.0033 4.93-6 132.21

.0146 1.64 18 484.57

.0130 6.02 7

147.21

.0036 1.83 19 646.06

.0044 8.03 8

161.51

.0040 2.01 20 1372.84

.0084 17.06 9

205.51

.0039 2.55 21 1453.54

.0080 18.06 10 220.20

.0071 2.74 22 1534.35

.0141:

19.07 11 228.25

.0036 2.84 23 1857.22

.0040 23.08 12 235.09

.0085 2.92 24 1938.08

.0038 24.08 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0547

.0210,/ 15%

.0321 -/ 34%

F1/ Enter = Accept F2= Paging is OFF F7= Title-

.0390

/ 51%:

F9= Copy EscaQuit; i

.2 e1 i

CHRG - CHARG. PUMP A INITIAL-Al-24A O!L PUMP Ax!AL 9.10 i

SPCCTRUM DISPLAY 05-APR-93 21:46 9.00,

ogy.i 4;

y VA ;. *ll'b a

8. 06.

1 3

.s' t

h 0.04 in d

0.0a..

  1. mm_,x _e 0

0 400 See 1290 1680 2000. I, 80 00 o

94 FREQUENCY IN HZ SPECS.02959 t

LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Initial-Al-24A OIL PUMP AXIAL Date/ Time:

05-APR-93 21:46:36 Amplitude Units:

.IN/SEC-PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK

' ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)'

VALUE

VALUE 1

-73.49

.0101

.91 13 396.40

.00311

-4.93' 2

80.74

.0218 1.00 14 471.42-

.0037 5.86 3

88.15

.0134 1.10 15 484.60

.0044

.6.02 4

118.03

.0088 1.47 16 646.14

.0051 8.03 5

132.22

.0146 1.64 17 708.11

.0042 8.80 6

146.88

.0288

-1.83 18 726.64

.0046.

9.03' 7

161.49

.0282 2.01 19 807.64

.0049-10.04

-)

8 176.84

.0029 2.20 20 969.26

.0031 12.04-9 293.67

.0028 3.65 21 1372.75

.0034 17.06 10 308.37

.0035 3.83 22 1453.53

.0801 18.06-11 322.97

.0088 4.01 23 1534;26

.0081 19.07 12 381.74

.0043 4.74 24 1937.96

.0043' 24.08 l

TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0996

.0102

/

1%

.0409

/ 17%

.0902'./-82%

i F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy.

Esc = Quit j 1

l i

?

,l l

CHRG - CHARG. PUMP A 1NITIAL-Al-25A GCARBOX INLf7 AXtAL HIGH FPCQ-0'87 i

SPECTRUM DISPLAY 05-APR-93.Ett47

.. w a

e L D i,,,

Px t

g.. 5.

A : i;'h

.4 g

9.83.

I,.

8.82,

r 0.01, a e

Jh e'

[jEll.etg seee 2ees seee 4eee n

FREQUENCY IN H2 SPEC

.01071 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A

. Meas. Point:

Initial-Al-25A GEARBOX INLET AXIAL HIGH.FREQ.

3 Date/ Time:

05-APR-93 21:47:04 Amplitude Units:-

IN/SEC.PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK'

' ORDER:

No.

(Hz).

VALUE VALUE NO.

-(Hz)

VALUE

-- VALUE.

1 29.54

.0120 1.00 13 796.82

.0043 27.04.

2 59.60

.0047 2.02 14 1888.01

.0045

-64.08 3

80.49

.0108~

2.73 15-2018.31

.0044 68.50' 4

110.40

.0046 3.75 16 2097.24

.0084 71.18 5

383.82

.0074 13.03 17 2891.20

.0059 98.12 6

471.19

.0053 15.99 18 2950.00

.0063 100.12:

7 485.48

.0043 16.48 19 2979.63

.0185

-101.13 8

619.81

.0052 21.04 20 3009.23

.0144 102.13 1

9 647.88

.0094 21.99

.21 3038.65'

.0165 103.13 10 678.78

.0103 23.04 22 3068.24

.0325 104.13 11 708.03

.0503 24.03 23 3097.58

.0207 105.13

]

12 737.30

.0158 25.02 24*

3127.18

.0053

~106.13 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS-

.0799 Undefined /

0%

.0775' / 94%

.0165

/

4%

F1/ Enter = Accept F2= Paging;is OFF F7= Title

.F9= Copy Esc = Quit J

q 1

1 I

.l

CMKi - CHARG. PUMP A I~

0.05 SPECTRUM DISPLAY eS-APR-93 21847 L. i' *:

4

e. 4 m

RPM e 4829.

u RPS = 80.47 I

e. e3.

5 Q e.e2.

i

~

W 4p

... e 6

I

-- u A IM 3

1000 2000 3000 4000 5000 FREQUENCY IN HZ SPECS.83192 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Initial-Al-26V PIPING HIGH FREQ Date/ Time:

05-APR-93 21:47:36 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE-1 1377.90

.0028 17.12 13 2420.16

.0054 30.07 2

1453.09

.0322 18.06 14 2505.80

.0014 31.14-3 1615.07

.0035 20.07 15 2586.14

.0013 32.14 4

1710.84

.0021 21.26 16 2742.79

.0018 34.08-5 1786.86

.0021 22.20 17 2820.17

.0016 35.04 6

1860.98

.0020 23.12 18 2906.70

.0036 36.12 7

1937.29

.0065 24.07 19 2988.80

.0021 37.14 8

2035.84

.0067 25.30 20 3390.68

.0012 42.13-9 2090.08

.0092 25.97 21 3713.35

.0010 46.14 10 2137.98

.0057 26.57 22 3877.54

.0013 48.18 11 2262.87

.0073 28,12 23 4279.79

.0010 53.18 12 2341.66

.0176 29.10 24 4359.37

.0017 54.17 TOTAL MAG SUBSYNCHRONOUS-SYNCHRONOUS NONSYNCHRONOUS

.0420 Undefined /

0%

Undefined /

0%

Undefined /

0%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

i t-CHRG - CHARG. PUMP A r!NAL-Al -tv MOTOR OtJTSOARD VERTICAL 0.010 l

SPECTRUM DISPLAY i

06-APR*93 02838

'l 0.0 0 9

W. s ';

9 g!

A : i;':a h"

0.006.

5-9 h

N0.0048 8

l 5

.j

e. 0e2.

c si ci n

O \\

L E

% -h --

d a

0 290 408 680 BP4 1000 FREQUENCY IN H2 SPEC 8.99532 j

LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Final-Al

-1V MOTOR OUTBOARD VERTICAL Date/ Time:

06-APR-93 02:38:16 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

-(Hz)

VALUE VALUE-1 9.35

.0006

.32 13 295.10

. 0008 10.04 s

2 29.49

.0059 1.00 14 323.24

.'0014 11.00 3

59.00

.0031 2.01 15 353.89

.0022 12.04-4 80.76

.0011 2.75 16 359.81

.0031 12.24 5

88.50

.0064 3.01 17 412.91-

.0008

-14.05 6

119.95

.0069 4.08 18 442.27

.0009 15.05-7 147.70

.0026 5.'02 19 454.59

.0006 15.46 8

161.73

.0007 5.50 20 471.89

.0006 16.05 9

179.00

.0016 6.09 21

.484.27

.0009 16.47 10 208.13

.0019 7.08 22 530.82

.0006 18.06-11 236.62

.0008 8.05 23 648.78

.0005 22.07 12 239.46

.0006 8.15 24 707.83

.0011 24.08 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0137

.0011

/

1%

.0108

/ 63%

.0083

/ 37%

-F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit' i

CHRG - CHARG. PutP A r!NAL-Al

-2H MOTOR OUTBOARD HORIZONTAL 0.012 i

SPECTRUM DISPLAY 06-APR-93 02:38 0.010.

9 PK =.0153 e

LOAD = 100.0 h

.000,,

=

0 g0 0.006,

9 3

0

)

~

8

~

n g 0.004 9.

I O

e.002.

n c

Ik P~

-h me>~, h 0

e

$l 6

200 400 600 800 1000 FRE N IN H2

$PEC1.00635 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Final-Al

-2H MOTOR OUTBOARD HORIZONTAL Date/ Time:

06-APR-93 02:38:34 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAX ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1-29.50

.0071 1.00 13 235.89

.0017 8.02 2

44.30

.0007 1.51 14 239.84

.0046 8.16 3

51.73

.0009 1.76 15 265.51

.0008 9.03 4

59.01

.0090 2.01 16 294.81

.0010 10.03 5

69.21

.0010 2.35 17 324.38

.0013 11.04 6

74.04

.0008 2.52 18 353.88

.0019 12.04 7

88.50

.0024 3.01 19 359.84

.0041 12.24 8

118.09

.0024 4.02 20 383.41

.0014 13.04 9

119.56

.0027 4.07 21 484.35

.0009 16.48 10 149.47

.0008 5.08 22 530.90

.0009 18.06 11 179.19

.0008 6.10 23 560.39

.0010 19.06 12 206.48

.0019 7.02 24 707.88

.0022 24.08 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0153

.0028

/

3%

.0126

/ 68%

.0083

/ 29%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit l

~

, ~.

l f

i OeG -- CHARG. PUPP A FINAL-Al

-3A' MOTOR OUTBOARD AXIAL 0.000 i

SPECTRUM DISPLAY 06-APR-93 02 38 PK e.0138

>%": In u.. s bl

/

RPS = 29,40 w

s

-j t

c ' *** -

f n

n E3 g 0.002.

EB El n

n k

d'"

O biboesh -

a m

I 8

296 400 680 See lese OR FREQUENCY IN H2 SPECS. 004r)

LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Final-Al

-3A MOTOR OUTBOARD AXIAL

.Date/ Time:

06-APR-93 02:38:49 Amplitude Units:

IN/SEC PK-PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY-PEAK ORDER-NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE a

1 9.40

.0006

.32 13 206.44

.0038.

7.02-2

-29.49

.0048 1.00 14 213.20-

.0007 7.25:

3 59.03

.0016 2.01 15 236.93

.0011 8.06.

4 80.63

.0008 2.74 16 265.51

.00191 9.03 5

89.17

.0030 3.03.

17 295.34

.0013-10.05' 6

94.61

.0008 3.22 18 324.43

.0019 11.04 7

119.60

.0028 4.07 19 346.94

.0005 11.80 8

147.57

.0045 5.02 20 353.96

.0033 12.04 M

9 161.92

.0016 5.51 21 359.70

.0012 12.24 10 168.16

.0007 5.72 22 383.48

.0013:

13.05-11 171.89

.0008 5.85 23 412.96

.0006

-14.05 12 178.17

.0053 6.06 24 707.89

.0007 24.08 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0138

.0033

/

6%

.0110

/ 63%

.0076 !/ 31%

- F1/ Enter = Accept F2= Paging is OFF F7= Title.

F9= Copy Esc = Quit'

)

J 1

, ~..

~.

.~.

=

1 C W - CHMtG. PUMP A

)

rtNAL-Al

-4V MOTOR INBOARD VE*TICAL -

0*O

.{

I SPECTRUM DISPLAY e6-APR-93 82:39

-g PK *.e337

e. e24,

LOAD = tee.e o'

RPM = 1764 g

RPS = 29.4e N

e.ets.

-E na g e.e:2 43 g

q y

g" t

g n

i e.ee6 t

ci n

n M

'P M L E'PEm=

e 1

[j[jl_ 3e g e

2ee 4ee see see sees rRcoucncy In Hz secC

.ete4e j

LIST OF SPECTRAL PEAKS 5

1 Machine:

(CHRG) CHARG. PUMP A i

Meas. Point:

Final-Al

-4V MOTOR INBOARD VERTICAL Date/ Time:

06-APR-93 02:39:08 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

10.59

.0038

.36 13 412.91

.0019

.14.05 2

29.48

.0116 1.00 14 471.92

.0030 16.05=

3 58.98

.0078 2.01 15 484.29

.0059 16.'47 4

88.45

.0109 3.01 16 501.41

.0011 17.06 5

119.85

.0222 4.08 17 530.91.

.0032 18;06

,i 6

149.40

.0017 5.08 18 619.37

.0013 21.07 7

178.94

.0027 6.09

-19 648.86

.0037 22.07-8 208.42

.0028 7.09 20 678.38

.0016 23.08-9 294.86

.0011 10.03 21 707.84'

.0095 24.08 10 323.16

. 0019-10.99 22 726.49

.0023-24.71.

-11 353.96

.0051 12.04 23 737.33

.0015-25.08 12 383.30

.0011 13.04 24

.766.83

.0013 26.09 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS'

.0337

.0045

/

2%.

.0226

/ 45%

.~0245

/ 53%

-F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy-Esc = Quit t

..m

'5 CHRG - CHARG. PUMP A r1NAL-A1

-5H m0 TOR INBOARD HORIZONTAL I

SPECTRUM DISPLAY e6-APR-93 e2s39 e.ei..

L. ;:e'$:

u o

. RPM = 1764.

g p

RPs - 29.4e b

e.e a,

E Q e.ees.Q

~

n N

$$ *(

g.

n e.ee4 e l E

'il 79 P9-6Rgos. gay e

ese 4ee see see sees m oucNcy in wz sPcci.esers LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Final-A1. -5H MOTOR INBOARD HORIZONTAL Date/ Time:

06-APR-93 02:39:30 Amplitude Units:,IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER' NO.

(Hz)

VALUE VALUE NO.

- (Hz).

VALUE

.VALUE 1

5.64

.0014

.19 13 353.93

.0020 12.04~

2 29.49

.0142 1.00 14 359'.79 0019 12.24 3

51.88

.0008 1.76 15 383.42

.0042

.13.04=

4-59.07

.0078 2.01 16 412.87

.0009 14.05 5

88.45

.0054 3.01 17 442.16

.0010 15.04 6

119.86

.0053 4.08 18 454.88

.0010 15.47 7

147.54

.0034 5.02 19 471.85

.0017-16.05 8

161.37

.0014 5.49 20 484.29

.0016 16.47' 9

176.93

.0013 6.02 21 530.85

.0018

'18.06-10 206.82

.0045 7.04 22 589.80

.0018 20.06 11 239.74

.0023 8.16 23 707.79

.0024 24.08 12 323.29

.0018 11.00 24 726.43

.0008 24.71 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS-NONSYNCHRONOUS

.0214

.0018

/

1%

.0192

/ 81%

.0092./.19%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy.

Esc = Quit w

CHRG = CHARG. PUMP A FINAL-Al

-6A MOTOR INBOARD AxfAL 0.0M 3

06-4PR-93 02:39

)

.6212 PK =

m LOAD = 100.0 0.012.

m.

iu4.

m RPS e 29.40 S

r

?

[ 0.000.

E

=

9" m

E d

5 y

n g e.ee< ~),

P c

n rf' n

g (

\\,,'

k

?.

$h

((

0' 200 400 600 000 1000 FPX aCNCY IN H2 SPCC:.00371 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Mcas. Point:

Final-Al

-6A MOTOR INBOARD AXIAL Date/ Time:

06-APR-93 02:39:57 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.48

.0041 1.00 13 239.67

.0011 8.15 2

58.97

.0055 2.01 14 353.90

.0020 12.04 3

80.60

.0016 2.74 15 383.33

.0025 13.04 4

88.51

.0076 3.01 16 471.88

.0031 16.05 5

94.57

.0015 3.22 17 484.31

.0053 16.48 6

119.99

.0116 4.08 18 530.86

.0023 18.06 7

149.29

.0051 5.08 19 560.31

.0025 19.06 8

161.55

.0026 5.50 20 565.03

.0017 19.22 9

167.96

.0010 5.71 21 589.73

.0016 20.06 I

10 178.21

.0035 6.06 22 648.75

.0011 22.07 11 206.16

.0011 7.01 23 707.80

.0048 24.08 12 235.88~

.0016 3.02 24 726.43

.0010 24.71 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0212

.0013

/

0%

.0143

/ 45%

.0156

/ 54%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit I

1

CHRG - CHARG. W "

r!NA-41

-7v CEARBOX INPUT YERTICAL 0.012 1

06 #e-93 02t40 0.010,

PK e.0134

{

LOAD = 100.0 u

RPM = 1768.

g RPS

  • 29.46

)

d CD b.

N 0.

h 9

h

8. 004,

7.

3 n

U N

0.002 o

k Mh'8 9

CL

'1 --

$h

^^

J 0

G 50 100 1 *A 200 250 300 3*A 400 FREQUENCY IN H2 SPECS.06436 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Final-Al

-7V GEARBOX INPUT VERTICAL Dat O/ Time:

06-APR-93 02:40:29 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(.iz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

5.69

.0005

.19 13 147.34

.0007 5.00 2

6.74

.0006

.23 14 149.41 4.75E-04 5.07 3

7.68

.0007

.26 15 161.42

.0018 5.48 4

8.28

.0007

.28 16 235.87 4.67E-04 8.01 5

10.74 5.00E-04

.36 17 242.13

.0008 8.22.

6 12.15

.0009

.41 18 265.37

.0008 9.01-7 29.49

.0044 1.00 19 294.89

.0011 10.01 8

58.99

.0010 2.00 20 322.83

.0063 10.96 9

80.71

.0019 2.74 21 324.38

.0020 11.01 10 110.20

.0009 3.74 22 353.87

.0088 12.01 11 117.94

.0005 4.00 23 359.80

.0008 12.21 12 119.94

.0031 4.07 24 383.35

.0025 13.01 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0134

.0019

/

2%

.0103

/ 59%

.0084

/ 39%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit-

i=

CHRG - CHARG. PUMP A FINAL-Al

-8H GEARBOX INPUT HORI2ONTAL 0.012 3

SPECTRtM DISPLAY 06-APR-93 02:40 0.010,

.PK

=.8168-g

J LOAD = 100.0 o

.eN RPM =' 1768.

RPS

  • 29.46 8.006,

's l.

5 A

ci g

g A

e.e86,

n 8

=

h 0.004,

d r

e i

. e.See,

n o

"n n

i.m@m l

Ad

-- d[

g L_

I t

FREQt 29.58 9

SG 100 156 298 250 300 350 480 "gpg h

FREQUENCY IN HZ

,j LIST.OF SPECTRAL PEAKS

                              • =******

Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Final-Al

-8H GEARBOX INPUT HORIZONTAL Date/ Time:

06-APR-93 02:40:47 Amplitude Units:.

IN/SEC PK l

PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK

' ORDER NO.

(Hz)

VALUE VALUE NO. _

(Hz)

VALUE-VALUE 1

'7.19

.0016

.24 13 206.43

.0017 7.01 2

29.50

.0016 1.00 14 235.94

.0008 8.01, 3

58.99

.0015-2.00 15 242.13

.0021 8.22 4

80.71

.0060 2.74 16

-265.41

.0017 9.01 5

117.95

.0031 4.00 17 294.87

.0013 10.01 6

119.96

.0011 4.07 18 322.83

.0012 10.96 7

147.28

.0024 5.00 19 353.90

.0011 12.01-1 8

149.44

.0015 5.07 20 360.06

.0007 12.22 9

161.42

.0082 5.48 21 380.20

.0009 12.90.

10 176.93

.0082 6.01 22 381.55

.0010 12.95 11 178.87

.001C 6.07 23 383.39

.0057

-13.01 12 190.78

.0009 6.47 24 385.67

.0008

-13.09 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0168

.0036

/

5%

.0112

/ 45%

.0119. /,50%

4 F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit j

y 3

o a

1

'CHRG ~

FtNAL*Al

    • A oks T#

0.012 i

SPCCTRUMDI%2 M -AFp.93 0 8.010 -

pg

.6t55' 3,

. 100.0 u

y 0.000.

ppg. 9

[ 0.0a.

g G

O n

v 9.084 -

N 0.042.

n o

n n n

' a 1*

.hhW e

1

_I l

t i

2 F

9 50 100 - 150 200 250 300 350 400 OR s FREQUEf1CY IN H2 SPCC:.00077 iI LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHAF PUMP A Meas. Point:

Final-Al si GEARBOX INPUT AXIAL Date/ Time:

06-APR-93 02:41:03 Amplitude Units:

IN/SEC PK m

PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER.

NO.

(Hz)

VALUE VALUE.

NO.

(Hz)

'VALUE

'. VALUE 1

5.'79

.0012

.20 13 176.94

. 0016 6.01-

-. i 2

8.22

.0009

.28 14 178.88

.. 0008' 6.07 v

3 29.49

.0088 1.00 15 235.94 0010 8.01' 4

58.98

.0047 2.00 16 242.14 0016 8'.22 5

80.71

.0057 2.74 17 265.42

.. 0013 9.01

'6 88.43

.0017 3.00 18 294.90 0014 10.~01 7

110.21

.0028 3.74 19 324.41 0009 11.01 8

117.95

.0017 4.00 20 353.87 0015.

12.01i 9

119.95

.0027 4.07 21 359.84 0011 12.21 t

10 139.71

.0012 4.74 22 381.70 0009 12.95' 11 146.74

.0009 4.98 23

-383.40 0059 13.01.

12 161.43

.0029 5.48 24 385.16 0008 13.07 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS-

.0155

.0021

/

2%

.0121' -/ 61%

.0094. / 37%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit.

i I

w.

w

,wr-e -

m -

o,yq

CW G - CHARG. PUMP A r t re:4.-A l

-10V GEARBOX O!L pep VERTICAL e

PK =

.0455 0.018,

k 8

E 9e

)

0. 012.

g O

R 8

N hI e 0.0u,,

l b8 L

0 0

1000 2000 3000 4000 FREQUENCY IN HZ SPEC 8

.00306 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Final-Al

-10V GEARBOX OIL P/P VERTICAL Date/ Time:

06-APR-93 02:41:25 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

322.80

.0056 10.96 13 2016.79

.0055 68.45 2

353.92

.0185 12.01 14 2095.46

.0041 71.12 3

412.64

.0039 14.00 15 2241.17

.0054 76.06 4

484.25

.0118 16.44 16 2359.11

.0048 80.07 5

707.85

.0104 24.02 17 2420.81

.0035 82.16 6

726.49

.0038 24.66 18 2978.95

.0089 101.10 7

1415.93

.0060 48.06 19 3008.41

.0077 102.10 8

1451.85

.0053 49.27 20 3037.76

.0085 103.10 9

1474.53

.0063 50.04 21 3067.28

.0165 104.10 10 1563.18

.0039 53.05 22 3096.82

.0135 105.10 11 1622.72

.0042 55.07 23 3126.30

.0051 106.10 12 1938.44

.0066 65.79 24 3214.81

.0036 109.11 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0455 Undefined /

0%

.0424

/ 87%

.0164

/ 13%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

_ ~..

A I

cHRo - cHARG. PUMP A FINAL-Al

-11H CEARBOX OIL pep HORIZONTAL I

SPECTRUM DISPLAY 06-APR-93 02:41 u.

. 04n k

8.03.

=

ug R

RPS = 29,46 s

s e.02 y

w

~

g e.e.

0 lE u

~

fI[

d 1000 2000 3000 4000 M NCY IN HZ SPEC 3

.00404 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A

. Meas. Point:

Final-Al

-11H GEARBOX OIL P/P HORIZONTAL l

Date/ Time:

06-APR-93 02:41:42 Amplitude Units:

IN/SEC PK PEAK FREQUENCY "EAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

'.,U E VALUE NO.

(Hz)

VALUE VALUE.

- i 1

29.40

.0043 1.00 13 1452.27

.0077 49.29 2

58.48

.0034 1.98 14 1474.54

.0054 50.04 3

80.77

.0064 2.74 15 1503.65'

-.0032 51.03-4 176.65

.0055 6.00 16 1533.45

.0074 52'04

- )

5 353'.98

.0064~

12.01 17 1563.55

.0034 53.07.

6 383.18

.0070 13.00 18 2919.95

.0035 99.10 7

410.78

.0047 13.94 19 2949.36

.0038.

100.10 8

484.27

.0152 16.44 20 2978.78

.0112 101.10~

9 678.08

.0061 23.01 21 3008.21

.0078 102.10:

I 10 707.88

.0271 24.02 22 3037.79

.0085 103.10 11 727.73

.0071 24.70 23 3067.23

.0123-104.10-12 1179.63

.0035 40.04 24

_3096.76

.0093

-105.10

~

TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS-NONSYNCHRONOUS-j

.0473 Undefined /

0%

.0435

/ 84%-

.0185

/ 15%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy' Esc = Quit.

i 1

.,=1 r

e y

,e y

CHpG - CHARG. PUMP A FM-H

  • t2A CEARBOX (!L P/P AXIAL 0.10 gy qg (pst-93 02t42 0.00 9

OAD=$

a R

=: Wh S

0.06 E

e 8

0.44 j

N n

e m

O L

U^'-

L f,I[

0 1000 2000 3000 4000 FREQUENCY IN HZ SPEC 8

.00010 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Final-Al

-12A GEARBOX OIL P/P AXIAL Date/ Time:

06-APR-93 02:42:00 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.64

.0085 1.01 13 678.13

.0102 23.01 2

59.33

.0043 2.01 14 707.78

.0701 24.02 3

80.21

.0040 2.72 15 726.88

.0167 24.67 4

322.91

.0046 10.96 16 734.52

.0145 24.93 5

354.04

.0114 12.02 17 767.01

.0043 26.03 6

412.50

.0068 14.00 18 1452.47

.0062 49.30 7

483.87

.0348 16.42 19 1563.00

.0049 53.05 8

510.09

.0046 17.31 20 1622.07

.0056 55.05 9

530.30

.0049 18.00 21 1798.65

.0039 61.04 10 563.69

.0039 19.13 22' 2978.61

.0049 101.09 11 619.92

.0079 21.04 23 3067.05

.0074 104.09 12 648.32

.0135 22.00 24 3096.52

.0063 105.09 TOTAL MAG SUBSY.NCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0892 Undefined /

0%

.0805

/ 81%-

.0384

/ 19%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

~

.. ~...... ~....

-. ~

1

'I CHRG - CHARG. PUMP A r!NAL-Al -13V GEARBOX OUTPUT VERT! CAL 0.04 i

SPECTRUM DISPLAY 06-APR-93 02:42 5

PK =.0447 h="/ 247 o.. 3.

u a

m.

S s

e. e2,

e y

s e

ci 15 'l g

0.01,

{ {

n

!i 9,

dLa&

'I 8

400 See 1298 1600 2988 ORIR!

  • h*

FREQUENCY IM HZ SPECI.00173 I

LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Final-Al

-13V GEARBOX OUTPUT VERTICAL Date/ Time:

06-APR-93 02:42:30 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY-PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

'(Hz)

VALUE VALUE 1

29.46

.0032

.37 13 726.44

.0046 9.03 2

323.01

.0098 4.01 14 737.34'

.0036

'9.16 3

353.90

.0293 4.40 15 807.21

.0030

-10.03 4

412.92

.0080 5.13 16 1179.62

.0042 14.66 5

442.28

.0034 5,50 17 1386.13

.0037 17.22 6

471.96

.0079 5.86 18 1415.54

.0045 17.59 7

484.30

.0081 6.02 19 1452.87

.0109 18.05 i

8 530.88

.0059 6.60 20 1533.59

.0064 19.06 9

564.77

.0040 7.02 21 1563.09

.0041' 19.42 10 648.58

.0037 8.06 22 1592.68

.0033 19.79 11 678.37

.0041 8.43 23 1710.56

.0041 21.26-12 707.81

.0146 8.80 24 1937.13

.0035 24.07 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0447

.0045

/

1%

.0168- / 14%

.0412

/ 85%

F1/ Enter = Accept F2= Paging'is OFF F7= Title F9= Copy Esc = Quit i

e

)

C OG - CHARG. Ptm A I

r!NAL-Al

-14H GEARBOX OUTPUT HORIZONTAL i

SFCCTRUM D!$ PLAY 06-APR-93 02 42 m

Pt(..0458 0.64 LOAD e 100.0 Ren - 4829.

a s

y RPS = 60 47 h

- 0.03.

E 5

g 0.02.

y e

e 0.01,wu au a O

I

(

0 400 000 1200 1600 2000 np FREQUENCY IN HZ

$PECe.00584 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Final-Al

-14H GEARBOX OUTPUT HORIZONTAL Date/ Time:

06-APR-93 02:42:42 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.53

.0039

.37 13 648.46

.0039 8.06 2

58.98

.0034

.73 14 678.29

.0063 8.43 3

80.72

.0062 1.00 15 707.76

.0352 8.79 I

4 148.04

.0027 1.84 16 726.35

.0075 9.03 5

176.95

.0053 2.20 17 737.28

.0061 9.16 6

323.37

.0025 4.02 18 796.36

.0024 9.90 7

353.92

.0082 4.40 19 807.16

.0025 10.03 8

383.59

.0058 4.77 20 1474.50

.0040 18.32 9

403.69

.0026 5.02 21 1533.55

.0046 19.06 10 412.67

.0036 5.13 22 1592.38

.0041 19.79 11 472.02

.0039 5.87 23 1621.93

.0032 20.15 12 484.24

.0125 6.02 24 1937.04

.0028 24.07 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0458

.0109

/

6%

.0174

/ 14%

.0409

/ 80%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit.

.. ~ ~.-

. ~. - -.-

CHRG - CHARG. PUMP A

~I 9.12 4

SPECTRUM DISPLAY 96-APR-93 02:43 0.10.

N

. PK - =.1035 i

s' LOAD = 100.8 l

u R

RPM =

4829..

RPS = 80.47 5

e. 86.

y e.e4 y

j 0.02,

[s lL9 a-1m9 oL9.fl L melm 4f e

90 6

400 -

900 1298 1600 2900 l

FREQlENCY IN HZ SPECS.00457 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Final-Al

-15A GEARBOX OUTPUT AXIAL Date/ Time:

06-APR-93 02:43:30 Amplitude Units:

IN/SEC PK.

.-J PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.50

.0117

.37 13 737.23

.0193 9.16 2

58.98

.0162

.73

.14 766.89

.0051 9.53-3 80.75

.0048 1.00 15 796.21

.0085 9.89 4

88.48

.0060 1.10 16 1179.58

.0071 14.66-5 383.49

.0053 4.77 17 1371.98

.0050 17.05 6

484.33

.0212 6.02 18 1415.57

.0076 17.59 7

564.84

.0092 7.02 19 1444.86

.0059 17.95 8

619.18

.0127 7.69 20 1452.67.

.0093 18.05 9

648.75

.0188 8.06 21 1474.43

.0094 18.32-10 678.22

.0160 8.43 22 1710.35

.0070 21.25 11 707.74

.0841 8.79 23

< 1887.10

.0050 23.45 12 726.36

.0168 9.03.

24 1936.99

.0049 24.07 TOTAL MAG SUBSYNCHRONOUS-SYNCHRONOUS-

.NONSYNCHRONOUS

.1035

.0204

/

4%

.0335

/ 10%

.0958

/ 86%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit..

t v

+.w, r er

m

.m..

4 4

C W - CWAG. PUNP A FINAL-41 -16v PUMP IN3D VERTICAL gg, 06-APR-93 02:43 PK =.0400 S

LOAD = 100.0

" '" i

: O s

s

].

0.012,

ejv 8

}

n h

n g 0.006,

2 n

n 8 b "El -

"8 I

80 00 800 1200 1600 2000 op 4

0 400

.FRECNENCY IN HZ SPEC 8 0$675 1

LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Final-Al

-16V PUMP INBD VERTICAL Date/ Time:

06-APR-93 02:43:52 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

.VALUE VALUE 1

80.71

.0177 1.00 13 311.39

.0035 3.87 2

118.13

.0034 1.47 14 316.54

.0032 3.93' 3

-132.13

.0029 1.64 15 321.77.

.0034 4.00 4

146.69

.0047

.1.82 16 484.14

.0072 6.02 5

161.32L

.0121 2.00-17

-806.93

.0064 10.03:

6 177.35

.0031 2.20 18 968.47

.0087 12.03.

'7 201.12

.0038 2.50 19 1372.02

.0055 17.05 8

204.22

.0043 2.54

-20 1452.83

.0095 18.05 9

221.07

.0110 2.75 21 1533.40

.0029 19.05 10 234.20

.0056 2.91 22 1614.13

.0031'

'20.06 11 242.24-

.0064 3.01 23 1856.17

.0037

.23.07..

12 293.92

.0042 3.65 24 1936.82

.0050.

24.07 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS.

.0400

.0027

/

0%

.0267 l/ 44%

.0297

/ 55%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit.

i 1

L r

p r-ppe 4

,e Se

-m.-g, fy E

=,s r

CHRG - CHARG. PUMP A II * *di

-17H PUNP INBD HORIZONTAL 6.08 CPECTRLRt DispLgy 06-APR-93 02:44 0.07,

PK =.0795 LOAD = 100.0 u 6.06.

Ren - 4829.

M PPS

  • 00.47 as g

s 0.04 d

0.03,

h E

y 0.02

{

~

I-n n

n n n 0./

ut L eL v. i_-

. - 91'i' e h

0 400 000 1200 1600 2000 FREQUENCY IN HZ SPECS.05429 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Final-Al

-17H PUMP INBD HORIZONTAL Date/ Time:

06-APR-93 02:44:05 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.71

.0572 1.00 13 242.24

.0079 3.01 2

126.09

.0040 1.57 14 38?.54

.0044 4.77 3

133.47

.0071 1.66 15 403.87

.0040 5.02 4

138.80

.0070 1.72 16 707.84

.0050 8.80 5

146.75

.0120 1.82 17 807.04

.0090 10.03 6

161.39

.0241 2.01 18 968.54

.0056 12.04 7

171.03

.0042 2.13 19 1372.14

.0088 17.05 l

8 190.60

.0094 2.37 20 1452.86

.0188 18.05 9

198.02

.0066 2.46 21 1533.59

.0103 19.06 10 205.95

.0068 2.56 22 1614.02

.0089 20.06 11 219.13

.0069 2.72 23 1775.85

.0108 22.07 12 234.58

.0087 2.91 24 1856.39

.0052 23.07 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0795

.0075

/

1%

.0651

/ 67%

.0450

/ 32%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit l

l

.~.

_. ~

t' CM G.- CHARG. PUPF A FINAL-A1

-t8A PUMP IMBD Ax!AL

0. H j

M-APR-93 02:44 d

LOAD =5 o

p : ;0 b

0. ie.

i r 0.00,

G 0.

i 0.04.

2

.g_

g o

.Gt 0.02.

ro, m_ EMIT n9mmn9 8.-

W g

I 8* h**

9 400 '

800 1200 1600 2000 OR FREQUENCY IN H2 SPEC

.05023 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas.. Point:

Final-Al

-18A PUMP.INBD AXIAL Date/ Time:

06-APR-93 02:44:18 Amplitude Units:

IN/SEC PK.

PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK.

ORDER NO. -

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.72

.0108 1.00 13

-1659.18

.0071 20,62 2

146.81

.0118 1.82 14 1684.03

. 0084 20.93.

3 161.40

.0148 2.01 15 1694.00

.0084 21.05 4

483.95

.0082 6.01 16 1699.22

.0082 21.11

~5 645.68

.0076 8.02 17 1710.93-

.0085

.21.26 6

806.97

.0096 10.03 18 1718.40

.0070

~ 21.35 7

1372.14

.0123.

17.05 19 1775.42

.0156 22.06 8

1452.74

.0967 18.05 20 1846.36~

.'0075

'22.94 9

1533.43

.0137 19.05 21 1856.00-

.0149 23.06 10 1614.31

.0382 20.06 22 1866.28

.0078 23.19 11-1624.55

.0069 20.19 23 1878.82.

.0072 23.35.

-12

-1653.64

.0075 20.55 24 1937.13

.0208 24.07

.. TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.1249

.0052- / -0%

.0522 '/.17%

.1134- /.82%

F1/ Enter = Accept F2= Paging isOFF.

F7= Title F9= Copy

' Esc = Quit.

1

l

~l

... ~

.. ~

CHRG - CHARG. PUMP A FINAL-Al

-19V PUNP OUTBD VERTICAL e.M i

SPECTRtm DISPLAY e6-APR-93 e2:44 e.e5.

PK e

.1e23 e

LOAD e lee.e o

J RPM e 4829.

pf, RPS =. ee.47 d

a s

E

e. e3.

y ci y

e.82.

e.es.

cm I

9 T I-I "' I" e c181 ' t' 9 " P I

ee' 4ee see 12ee 16ee 2eee Wl eeg FREQUDtCY IN HZ SPECS.e246e LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Final-Al

-19V PUMP OUTBD VERTICAL Date/ Time:

06-APR-93 02:44:35 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER' NO.

(Hz)

VALUE VALUE NO.

(Hz).

VALUE VALUE 1

29.52

.0277

.37 13 176.64

.0052 2.20 2

58.94

.0235

.73 14 220.69

.0051 2.74 3

73.46

.0244

.91 15 233.94

.0049 2.91 4

80.79

.0263 1.00 16

.322.87

.0078 4.01 5

88.15

.0363 1.10 17 484.07

.0040 6.02 6

102.75

.0073 1.28 18 645.95

.0040 8.03 7

110.99

.0157 1.38 19 707.28

.0036 8.79 8

117.79

.0341 1.46 20 968.53

.0035 12.04 9

131.93

.0232 1.64 21 1452.78

.0298 18.05 10 139.31

.0093 1.73 22 1775.66

.0037 22.06 11 146.91

.0405 1.83 23 1856.23

.0047' 23.07 12 161.37

.0341 2.01 24 1936.87

.0054 24.07 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.1023

.0413

/ 16%

.0458 - / 20%

.0816

/ 64%'

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy' Esc = Quit'

p.

CHRG - CHARG. PUNP A r!NAL-Al

-20H PUMP OUTBOARD HORIZONTAL 0.10 i

SPECTRUM DISPLAY 06-APR-93 02:44 -

Pt<

=.1920 8.90,,S, LOAD = 100.O u

l}

RPM e 4829.

RPS = 09.47 b

0.06.

r e

5 g 0.04,

Y 9

m g

a, 0.02.

3'ou p al:rsrm 9 m - - $ f me

= _

N gL M

OS e

400 See 1200 1640 2000 FREQUENCY IN HZ SPEC 8.05953.

1 LIST OF SPECTRAL PEAKS Machine:

.(CHRG) CHARG. PUMP A 3

Meas. Point:

Final-Al

-20H PUMP OUTBOARD HORIZONTAL Date/ Time:

06-APR-93 02:44:47 Amplitude Units:

IN/SEC 'PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.44

.0041

.37 13 191.02-

.0032 2.37' 2

58.90

.0030

.73 14 293.68

.0030 3.65 3

80.71

.0733 1.00 15 322.65

.0037, 4.01 4

101.06

.0072 1.26 16 475.94

.0044' 5.91 5

103.77

.0068 1.29 17 484.21

.0225 6.02 l

6 113.33

.0066 1.41 18 536.02

.0032 6.66

}i 7

116.54

.0063 1.45 19 551.10

.0040 6.85 I

8 126.07

.0053 1.57 20 558.29

.0038 6.94 9

131.96

.0232 1.64 21

.563.96:

.0032 7.01 j

10 140.96-

.0044 1.75 22 707.65

.0054 879~

11 146.86

.0329 1.82 23, 1452.72

.0060 18.05 j

12 161.40

.0428 2.01 24 1533.45

.0070' 19.05'

')

TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS' NONSYNCHRONOUS-

.1020

.0098- /

1%

.0878 '/ 74%

.0510./ 25%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy'

. Esc = Quit 1

s a

CHRG - CHARG. PUMP A FINAL-At -2tA PUNP OUTBOAAD AXTAL 0 29 i

06-APR-93 02:45 PK e

,1444 6.16,

M LOAD = 100.0 Q

RPM = 4829.

o p

RPS e 80.47

-a 0.12,

5

~.

0. 8e.

g d

r n

8.04 M3 b

9m n9 Pen 9, E-noo" 0

n_n-8 I

8 400 000 1200 1600 2000 OR 5

FREQUENCY IN H2 SPEC 1.62877 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Final-Al

-21A PUMP OUTBOARD AXIAL Date/ Time:

06-APR-93 02:45:03 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.46

.0140

.37 13 468.59

.0032 5.82 2

58.93

.0103

.73 14 472.01

.0040 5.87 3

73.42

.0058

.91 15 484.19

.0122 6.02 4

80.72

.0304 1.00 16 646.09

.0045 8.03 5

88.24

.0123 1.10 17 707.81

.0034 8.80 6

103.80

.0031 1.29 18 726.33

.0045 9.03 7

117.7C

.0095 1.46 19 968.55

.0047 12.04 8

132.20

.0076 1.64 20 1452.69

.1347 18.05 9

146.92

.0068 1.83 21 1533.38

.0091 19.05 10 161.35

.0146 2.00 22 1775.45

.0035 22.06 11 176.95

.0033 2.20 23 1856.30

.0041 23.07 12 323.04

.0044 4.01 24 1936.80

.0063 24.07 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.1444

.0190

/

2%

.0618

/ 18%

.1291

/ 80%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

)

CHRG - CHARG. PUMP A r !WA -Al

-22v OIL PUMP VERTICtt g,g I

$PECTRt#1 DISPLAY 06-APR-93 02:45 0.05 pg.,g877 9

LOAD = 100.0 u

.' e A

RPM e 4829.

1 y,,,

3 g

ees - 80.47 b

d ra 5

83 0.e3 g

b

0. 0a..

t 0.01.

i en 0

1 n o n 9 - et, m 9 PDPI I

84 00 O

400 000 1200 1600 2000 hp y

FRE N IN H2 Spgg

,gj812 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Final-Al

-22V OIL PUMP VERTICAL Date/ Time:

06-APR-93 02:45:19 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.46

.0274

.37 13 234.42

.0066 2.91 2

59.00

.0165

.73 14 298.94

.0102 3.71 3

73.41

. 0." A 3

.91 15 313.68

.0143 3.90 4

80.72

. 0.

1 1.00 16 322.71

.0367 4.01 5

88.11

.0325 1.09 17 381.43

.0061 4.74 6

103.38

.0094 1.28 18 476.12

.0060 5.92 l

7 118.14

.0372 1.47 19 483.94

.0116 6.01 8

131.94

.0213 1.64 20 491.45

.0048 6.11 9

146.81

.0417 1.82 21 645.35

.0056 8.02 10 161.25

.0353 2.00 22 1452.33

.0060 18.05 11 176.43

.0058 2.19 23 1533.09

.0051 19.05 12 219.33

.0082 2.73 24 1936.69

.0076 24.07 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.1077

.0394

/ 13%

.0569

/ 28%

.0826

/ 59%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit 1

l i

i rgegd_-Al 3H 9.64 6

spgg7Rurt DISPLAY 06-APR*93 02845 D

PK =

.0633 3

\\

u.. 3 RPS e 80.47 s

a 0.02.

o g

5 j

j 9

7 g

0.01.

n

>o o

n on e LA 69 bE zW A I

FRC 8

0 400 000 1200 1600 2000 FREQUENCY IN HZ SPECS.02991 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Final-Al

-23H OIL PUMP HORIZONTAL Date/ Time:

06-APR-93 02:45:34 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.65

.0313 1.00 13 968.29

.0041 12.03 2

101.56

.0071 1.26 14 1371.68

.0083 17.04 3

117.69

.0142 1.46 15 1452.33

.0069 18.05 4

132.00

.0130 1.64 16 1533.08

.0180 19.05 5

147.36

.0041 1.83 17 1613.84

.0069 20.05 6

220.18

.0083 2.74 18 1828.89

.0048 22.73 7

234.78

.0088 2.92 19 1855.94

.0064 23.06 8

242.15

.0064 3.01 20 1908.94

.0042 23.72 9

278.84

.0060 3.46 21 1921.32

.0052 23.87 10 293.47

.0060 3.65 22 1936.36

.0074 24.06 11 322.95

.0063 4.01 23 1961.28

.0047 24,37 12 484.24

.0141 6.02 24 1974.23

.0048 24.53 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0633

.0234

/ 14%

.0403

/ 41%

.0428

/ 46%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

CHRG - CHARG. PUNP A 0.18

~ "

I WCCTRW MM 06 APR-93 02:45 g, g ex..i272 a"-

0 F#/12;'

RPS = 80.47 r

0.10.

w b

0.00,

8

{ 0.06,

f-t

0. 04 0.02,,

YomETY-e

' n i e D -4 ab=c5on mo 88 %

0 400 800 1200 1600 2000 l

4 FREQUENCY IN K2 SPECS. d 4'52 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Final-Al

-24A OIL PUMP AXIAL Date/ Time:

06-APR-93 02:45:47 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER.

NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

73.45

.0089

.91 13 484.03

.0044 6.01 2

80.67

.0257 1.00 14 707.76

.0059 8.79 3

88.11

.0126 1.09 15 726.29

.0031 9.03 4

117.14

.0052 1.4G 16 796.52

.0032 9.90 5

132.02

.0130 1.64 17 806.91

.0031 10.03 6

146.79

.0253 1,82 18 968.56

.0034 12.04 7

161.44

.0257 2.01 19 1452.46

.1234 18.05 8

176.77

.0034 2.20 20 1533.13

.0075 19.05 9

322.75

.0077 4.01 21 1775.19

.0074 22.06 10 381.55

.0054 4.74 22 1855.90

.0081 23.06 11 396,12

.0031 4.92 23 1878.75

.0031 23.35 12 471.16

.0031 5.85 24 1936.39

.0084 24.06 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.1372

.0122. /

1%

.0648

/ 22%

.1204

/ 77%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit 1

l CHtG

  • CH4tG. PUNP A l

O'O' r1NAL-Al -25A GEARBOX INLET AX!AL HIGH FREQ

.j I

SPECTRUN DISPLAY J

06-APR-93 02:46 0.05,

N PK a.0044 L.OAD.= 100.0 N

rN i760.

o RPS e 29.47 E

I.

0.03.

3O 8

h 0.02.

r 0.0i lE'

L L' ')

0 3

-[p3 '.l0609 0

1000 2006 -

3000 4000 FREQUENCY IN HZ SPECS 0

LIST OF' SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Final-Al

-25A GEARBOX INLET AXIAL HIGH FREQ Date/ Time:

06-APR-93 02:46:10 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.46

.0091 1.00 13 796.64

.0052 27.04 2

82.27

.0062 2.79 14 1452.48

.0084 49.30 3

382.84

.0055 12.99 15 2096.88

.0099 71.16 4

469.01

.0050 15.92 16' 2889.87

.0060 98.08 5

484.38

.0150 16.44 17 2919.69

.0050-99.09 6

619.78

.0051 21.03 18 2948.60'

.0076' 100.07 7

648.98

.0062 22.03 19 2978.30

.0224

'101.08 8

678.13

.0081 23.01 20 3007.75

.0160 102.08 9

707.73

.0471 24.02 21 3037.16

.0192 103.08-10 727.73

.0124 24.70 22 3066.64

.0374 104.08 11 735.73

.0141 24.97 23 3096.18'

.0243

~105.08 12 766.41

.0054 26.01 24 3125.73

.0069 106.08 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS'

.0844 Undefined /

0%

.0810

/ 92%

.0204

/

6%

F1/ Enter = Accept.

F2= Paging is OFF F7= Title F9= Copy Esc = Quit t

e e,r4-w

i l

~

r t Nct.-Al

~26V P!'PINF HIGH FREQ i

SPECTRUN DISPLAY l

06-APR-93 02:46 PK e

.12%

LOAD = 100.0

)

~~

=: ;0 b

!"0.05 ?

s.

r A

NX 8

0.03.

r 0.0a.

l 0.01.

0 mI bs__ __

I

$ IM 1000 2000 3000 4000 5000 FREQUENCY IN H2 SPECS.04535 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP A Meas. Point:

Final-Al

-26V PIPING HIGH FREQ Date/ Time:

06-APR-93 02:46:32 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

1379.29

.0017 17.14 13 2589.50

.0127 32.18 2

1452.58

.0456 18.05 14 2637.96

.0108 32.78 3

1535.71

.0036 19.08 15 2739.46

.0169 34.04 4

1611.97

.0048 20.03 16 2813.33

.0076 34.96 5

1768.99

.0126 21.98 17 2905.43

.0088 36.10 6

1857.31

.0098 23.08 18 2988.63

.0039 37.14 7

1918.24

.0132 23.84 19 3140.45

.0026 39.02 8

2035.62

.0190 25.30 20 3232.79

.0026 40.17 9

2104.22

.0599 26.15 21 3709.85

.0019

-46.10 10 2178.20

.0435 27.07 22 3874.72

.0035 48.15 11 2334.24

.0410 29.01 23 4034.56

.0015 50.13 12 2417.75

.0327 30.04 24.

4114.94

.0016 51.13 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.1206 Undefined /

0%

Undefined /

0%

Undefined /

0%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

=

i AUXILIARY BUILDING

, SPECTRA FROM MORE THAN OPE MACHINC b

710 GPN-B2-16V 999eonam9------nc-~~

-e 01-APR-93 16:51 f*"

700 GPM-82-16V o

f PLOT

~

I~

~'

2 SPAN 690 GPM-82-16V 9.24<

12 a 01-APR-93 16s19 b

680 GPN-B2-16V 01-APR-93 15:59 1m 0~

tr 9 31 660 GPM-B2-16V g

12 - -

01-APR-93 14:50 640 GPM-B2-16V 11 01-APR-93 14:30 620 GPN-D2-16V 01-APR-93 13:30 1a i I[

[

0 400 800 1200 1600 2000 FREQUENCY IN H2 SPC88

.104 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

710 GPM-B2-16V PUMP INBD VERTICAL Date/ Time:

01-APR-93 16:51:32 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.71

.1044 1.00 13 471.52

.0044 5.86 2

146.78

.0080 1.82 14 484.12

.0113 6.02 3

161.42

.0231 2.01 15 645.56

.0066 8.02 4

176.91

.0073 2.20 16 706.88

.0044 8.78 j

5 206.10

.0070 2.56 17 726.13

.0112 9.02 6

223.71

.0071 2.78 18 761.12

.0042 9.46 7

226.53

.0076 2.81 19 806.94

.0298 10.03 8

235.89

.0057 2.93 20 1371.82

.0056 17.05 9

242.01

.0180 3.01 21 1452.57

.0135 18.05 10 322.89

.0194 4.01 22 1921.20

.0040 23.87 11 354.16

.0046 4.40 23 1923.93

.0041 23.91 12 403.55

.0088 5.01 24 1936.93

.0090 24.07 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.1233

.0035

/

0%

.1158

/ 88%

.0422

/ 12%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9=Cnoy Esc = Quit i

l 1

l l

1 l

i

m AUX 1L1ARY BUILDING SPECTRA FROM NORE THAN ONE MACHINE o

710 GPM-82-17H m oo n n.,-

-n nm m

- en o -n nn_n_

01-APR-93 16:51 700 GPM-B2-17H h

01-h93 16 03 PLOT g

$ PAN 690 GFM-B2-17H 9.40-i 01-APR-93 16119 5

680 GPM-B2-17H g

01-APR-93 15:59 y

675 GPM-D2-17H 0-2 i-01-APR-93 15832 660 GPM-B2-17H

-2 01-APR-93 14850 g

640 GPM-B2-17H 01-APR-93 14 31

-i 620 GPM-32-17H 01-APR-93 13:39

- 1

[h 0

400 000 1200 1600 2000 FREQUENCY IN HZ SPC88

.199 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

710 GPM-B2-17H PUMP INBD HORIZONTAL Date/ Time:

01-APR-93 16:51:46 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.71

.1983 1.00 13 484.09

.0109 6.02 2

139.00

.0083 1.73 14 806.73

.0058 10.03 3

146.69

.0224 1.82 15 1372.02

.0167 17.05 4

161.56

.0087 2.01 16 1452.64

.0128 18.05 5

176.18

.0061 2.19 17 1533.48

.0145 19.06 6

188.89

.0085 2.35 18 1775.94

.0059 22.07 7

198.96

.0059 2.47 19 1829.01

.0052 22.73 8

205.99

.0078 2.56 20 1845.56

.0078 22.94 9

219.71

.0050 2.73 21 1853.89

.0085 23.04 10 242.27

.0184 3.01 22 1865.86

.0069 23.19 11 322.86

.0240 4.01 23 1913.22

.0057 23.78 12 403.54

.0087 5.01 24 1936.14

.0073 24.06 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.2108

.0181

/

1%

.2021

/ 92%

.0573

/

7%

.F1/ Enter = Accept F2= Paging is OFF F7= Title

'F9= Copy Esc = Quit-i i

i

e AUWILIARY BUILDING SPECTRA FROM MORE THAN ONE MACHINC EB 9

710 GPM-B2*i9V

,Jpanfnnnnmmm---no-n-nnn 8t-APR-93 16852 700 GPM-82-19V f

'I' I'

PLOT SPAN 690 GPM-BP-19V

0. 20 <

_I

-J 1

01-APR-93 16819 2

5 600 GPM-82-19V c _1 1

01-APR-93 16:00 g

0,,

1 Ap 9 32 2

1 660 GPM-B2-19V g

11 01-APR-93 14 51 e

i 640 GPM-82-19V

,_11 1

1 01-APR-93 14:32 i

i 620 GPM--B2-19V A.

01-R-93 13 3,9 0

400 000 1200 1600 2000 ORDRs 1.003 FREQUENCY IN HZ SPC8s.09920 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

710 GPM-B2-19V PUMP OUTBD VERTICAL Date/ Time:

01-APR-93 16:52:06 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.50

.0066

.37 13 236.08

.0033' 2.93 2

58.99

.0101

.73 14 241.95

.0109 3,01 3

66.05

.0056

.82 15 278.98

.0033 3.47 4

80.71

.0992 1.00 16 293.33

.0051 3.65 5

88.33

.0379 1.10 17 308.13

.0041 3.83 6

98.54

.0038 1.22 18 323.01

.0122 4.01 7

116.50

.0057 1.45 19 171.64

.0069 5.86 8

131.82

.0190 1.64 20 484.20

.0305 6.02 9

146.87

.0452 1.83 21 616.55

.0041 7.66 10 161.55

.0603 2.01 22 631.10

.0034 7.84 11 176.72

.0103 2.20 23 645.86

.0048 8.03 12 205.87

.0044 2.56 24 1452.69

.0110 18.05 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.1418

.0144

/

1%

.1206

/ 72%

.0733

/ 27%

i F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit 1

x o

s AUXILIARY BUILDING SPECTRA FROM MORC THAN Ort MACHINC si 1p m 9 m a m m m - - - - m n a o - -.- - m710 GPM-E2-20H 01-APR-93 16 52 700 GPM-B2-20H g

u 01-APR-93 16 34 L,f t.

i Of 3

SPAN 1

690 GPM-B2-20H 2

-- i 01-APR-93 16:20 0.20 '

1 N

600 GPM-B2-20H g

m{A t

m a

OL-APR-93 16 00

~

675 GPM-B2-20H u

0, J

01-APR-93 15:32 a

L 660 GPM-B2-20H g

E -

t 01-APR-93 14t31 fd 640 GPM-B2-20H 01-APR-93 14 32 620 GPM-BR-20H I

E 1

01-R-93 1384,0 0

400 000 1200 1600 2000 oppa 3,g83 FREQUENCY IN HZ

$PC8:.09007 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

710 GPM-D2-20H PUMP OUTBOARD HORIZONTAL Date/ Time:

01-APR-93 16:52:20 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.73

.0981 1.00 13 428.25

.0037 5.32 2

103.66

.0065 1.29 14 484.20

.0219 6.02 3

111.39

.0115 1.38 15 513.37

.0033 6.38 4

131.69

.0069 1.64 16 571.19

.0033 7.10 5

146.73

.0377 1.82 17 618.03

.0047 7.68 6

161.42

.0751 2.01 18 645.49

.0059 8.02 7

176.58

.0067 2.19 19 726.20

.0039 9.02 8

205.70

.0037 2.56 20 796.28

.0038 9.90 9

219.52

.0036 2.73 21 806.84

.0075 10.03 10 242.14

.0113 3.01 22 1452.59

.0082 18.05 11 322.93

.0056 4.01 23 1533.27

.0081 19.05 12 423.28

.0034 5.26 24 1936.75

.0036 24.07 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.1378

.0104

/

1%

.1259

/ 84%

.0549

/ 16%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit L

aux!LIARY BUILDING

$PECTRA FROM MORE THAN ONE MACHINE I

l Y

710 GPM-B2-21A o9nn,.9 ocn-m----

Aom 01-APR-93 16:52

{

700 GPM-B2-21A h

PLOT 01-

-93 16:34 2

3 WAN 690 GPM-B2-214

^ -

01-APR-93 16:20 0.24<

b l

680 GPM-B2-21A 01-APR-93 16:00 g

n-m e

U l

675 GPM-B2-21A 8-01-APR-93 15:32 660 GPM-B2-21A g

01-APR-93 14:51 a_

i

=

m l

640 GPH-B2-21A 01-APR-93 14:32 620 GPM-B2-21A~

Im __ __

1 01-APR-93 13:40

((

I 0

400 000 1200 1600 2000 FREQUENCY IN HZ SPC8:.01222 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

710 GPM-B2-21A PUMP OUTBOARD AXIAL Date/ Time:

01-APR-93 16:52:34 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.68

.0122 1.00 13 645.49

.0123 8.02 2

88.52

.0082 1.10 14 707.07

.0050 8.79 3

146.67

.0059 1,82 15 726.23

.0075 9.03-4 161.32

.0222 2.00 16 806.65

.0028 10.02 5

177.07

.0039 2.20 17 968.40

.0030 12.03 6

206.35

.0045 2.56 18 1452.51

.0871 18.05 7

242.18

.0053 3.01 19 1533.23

.0120 19.05 8

322.93

.0059 4.01 20 1779.31

.0028 22.~11 9

412.63

.0042 5.13 21 1868.92

.0031 23.23 10 471.53

.0068 5.86 22 1876.31

.0032 23.32 11 484,10

.0198 6.02 23 1923.65

.0027 23.91 12 618.62

.0029 7.69 24 1936.37

.0061' 24.06 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.1003 0125

/

2%

.0512

/ 26%

.0853

/'72%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

4 AUXILIARY BUILDING

,SPECteA FROM MORE THAN ONE MACHINC 710 GPM-B2-26V Ol-APR-93 16:52 t.",e M

= r i:re0 PLOT

-AP 9

01 f 33 0-

-AP g

9 52 640 GPM-92-26V 01-APR-93 14s33 3-

_A 0 -AP 9

40 I

$ INN 1000 2000 3000 4000 5000 6000 FREQUENCY IN HZ SPC88.05927 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

710 GPM-B2-26V PIPING HIGH FREQ Date/ Time:

01-APR-93 16:52:54 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

1061.76

.0013 13.19 13 2138.03

.0094 26.57 2

1135.90

.0016 14.12 14 2260.92

.0112 28.10 3

1207.65

.0019 15.01 15 2335.82

.0106 29.03 4

1238.27

.0016 15.39 16 2418.10

.0088 30.05 5

1385.65

.0038 17.22 17 2488.86

.0033 30.93 6

1453.32

.0593 18.06 18 2566.97

.0055 31.90 7

1534.63

.0107 19.07 19 2711.38

.0040 33.70 8

1610.49

.0114 20.01 20 2832.97

.0027 35.21 9

1782.97

.0182 22.16 21 2903.68

.0031 36.09 10 1814.04

.0165 22.54 22 2985.83

.0021 37.11 11 1912.28

.0115 23.76 23 3873.65

.0024 48.14 12 1986.68

.0122 24.69 24 4235.60

.0011 52.64 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0764 Undefined /

0%

Undefined /

0%

Undefined /

0%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit-

9 e

CHRG - CHARG. PUMP 3 1N!TIAL-B1-1V MOTOR OUTBOARD VERTICAL

0. 0%

01-APR-93 06:21 0.005 e

PK =.0004 g

LOAD = 100.0 RPM = 1764.

o RPS = 29.40 a

5 c"

f 0.003.[

s 3

D e

e 8

A y 0.e02.

R E

n n

0.001 n

k5Md bN9 ino-,.

0

((

hN 0'

200 400 600 000 1000 FREQUENCY IN HZ

$PECt

.00264 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Initial-B1-1V MOTOR OUTBOARD VERTICAL Date/ Time:

01-APR-93 06:21:56 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

8.22 3.71E-04

.28 13 353.91

.0018 12.04 2

29.50

.0029 1.00 14 359.85

.0008 12.24 3

58.97

.0035 2.01 15 383.22

.0005 13.04 4

80.81 3.23E-04 2.75 16 412.96 4.31E-04 14.05 5

88.41

.0015 3.01 17 471.93

.0016 16.05 6

119.94

.0042 4.08 18 484.36

.0010 16.48 7

148.02

.0008 5.04 19 530.86

.0010 18.06 8

177.98

.0008 6.05 20 560.51 3.68E-04 19.07 9

235.93 4.26E-04 8.03 21 619.36 4.08E-04 21.07 10 239.84

.0007 8.16 22 678.34 3.50E-04 23.08 11 294.89 4.42E-04 10.03 23 707.85

.0029 24.08 12 324.22

.0016 11.03 24 726.49

.0007 24.71 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0084

.0008

/

1%

.0061

/ 53%

.0057

/ 47%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit i

1 j

I

a CHRG - CH4r(G. PUMP B IMITIAL-B1-2H MOTCR OtJTBOARD HORIZONTAL 0.012 I

SPECTRUM DISPLAY 01-APR-93 06:22 0.010,

PK =.0144 9

LOAD = 100.0 o

RPM

  • 1764.

0.008,

q 8i E

~

~

0.006 E

e 8

y 0.004 sq r

e.0e2.

ni /'

O Nd 9

wY Y ' G797i nam -

f0 0

200 400 600 800 1000 FREQUENCY IN HZ SPECS.00417 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Initial-B1-2H MOTOR OUTBOA.RD HORIZONTAL Date/ Time:

01-APR-93 06:22:43 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

8.15

.0006

.28 13 324.27

.0020 11.03 2

29.50

.0046 1.00 14 331.83 3.79E-04 11.29.

3 58.99

.0085 2.01 15 353.98

.0018 12.04 4

80.67

.0006 2.74 16 359.84

.0064 12.24 5

88.49

.0014 3.01 17 383.36

.0010 13.04 6

119.96

.0062 4.08 18 403.47 4.71E-04 13.73 7

147.91

.0006 5.03 19 412.89

.0008 14.05 8

206.47

.0009 7.02 20 471.88

.0005 16.05 9

235.98

.0007 8.03 21 484.28

.0008 16.47 10 239.86

.0029 8.16 22 530.90

.0007 18.06 11 294.91

.0016 10.03 23 619.34 3.77E-04 21.07 12 299.53

.0006 10.19 24 707.83

.0009 24.08 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0144

.0013

/

1%

.0107

/ 56%

.0095

/ 43%

Fl/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

CHRG - CHARG. PUMP B INITIAL-31 3A MOTOR OUTWAD AM 0.029 L

SPECTRUM DISPLAY j

01-APR-93 06:22 0.0ie.

e GAi. 25 RPM = 1764.

1 o

RPS = 29.40 j

S

0. 0:2.

E D

1 0.008,

q 0.004 m y

h TTs;:FEWoT.,innoo77mm m 0 b IY

((

0 200 400 600 800 1000 op FREQUENCY IN HZ SPECS.00193 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Initial-B1-3A MOTOR OUTBOARD AXIAL Date/ Time:

01-APR-93 06:22:59 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.48

.0022 1.00 13 324.14 4.55E-04 11.03 2

58.99

.0021 2.01 14 330.39

.0007 11.24 3

76.77

.0006 2.61 15 353.92

.0051 12.04 4

85.31 4.53E-04 2.90 16 359.84

.0027 12.24 5

89.13

.0012 3.03 17 383.22

.0005 13.04 6

119.95

.0136 4.08 18 403.52

.0007 13.73 7

148.15

.0007 5.04 19 412.86

.0007 14.04 8

161.72 4.25E-04 5.50 20 471.89

.0011 16.05 9

176.wo

.0020 6.02 21 484.27

.0006 16.47 10 206.55

.0006 7.03 22 530.83

.0008 18.06 11 235.98

.0008 8.03 23 678.32.

.0006 23.08 12 239.85

.0009 8.16 24 707.81

.0007 24.08 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0159

.0014

/

1%

.0086

/ 29%

.0133

/ 70%

F1/ Enter = Accept F2= Paging is OFF F7= Title.

F9= Copy Esc = Quit I

CHRG - 0%RG. PUMP 3 INIT!AL-Bi-4V MOTOR INBOARD VERT! CAL 01-APR-93 06:23 0.016 -

OAD a 500

": i;':a g
    • 9.012 E

a g 0.00s.

,a Y

E "n,

0.0e4 1"

T med1bb dLm 0 <

((

0 200 400 600 000 1000 FREGIVENCY IN E SPECS.00254 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Initial-B1-4V MOTOR INBOARD VERTICAL Date/ Time:

01-APR-93 06:23:27 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE-VALUE 1

29.47

.0029 1.00 13 560.39

.0021 19.06 2

58.94

.0014 2.01 14 586.73

.0015 19.96 3

88.45

.0023 3.01 15 589.90

.0023 20.07 4

119.95

.0116 4.08 16 619.37

.0062 21.07 5

324.41

.0019 11.04 17 646.74

.0031 22.00 6

353.92

.0089 12.04 18 648.86

.0048 22.07 7

383.30

.0026 13.04 19 678.35

.0057 23.08 8

403.55

.0028 13.73 20 707.86

.0151 24.08 9

412.90

.0038 14.05 21 726.49

.0043 24.71 10 471.93

.0031 16.05 22 737.36

.0018 25.08 11 484.35

.0023 16.48 23 766.85

.0024 26.09 12 530.89

.0032 18.06 24 796.33

.0014 27.09 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.'0263

.0014

/

0%

.0142

/ 29%

.0221

/ 71%

F1/ Enter = Accept F2= Paging.is OFF F7= Title F9= Copy Ecc= Quit

e CHRG - CHARG. PL+P B INITIAL-Bi-5H NOTOR INBOARD HORl20MTAL L. i:r:

o aia - s

: m :;

. e Ed

~

l 5

9 e.eee 8

I Y

b g e.Ge4,

h) 4 a

i M

?N lP m a,.

e F EJl

!ad?

I J

e ese 400 see

-see tese FREQUENCY IN H2

)

SPECt.e8706 LIST OF SPECTRAL PEAKS I

l Machine:

(CHRG) CHARG. PUMP B 1

Meas. Point:

Initial-B1-5H MOTOR INBOARD HORIZONTAL l

Date/ Time:

01-APR-93 06:23:48 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.50

.0078 1.00 13 383.46

.0020 13.04 2

58.99

.0101 2.01 14 389.29

.0008 13.24 3

80.71

.0008 2.75 15 403.49

.0016 13.73 4

88.47

.0016 3.01 16 412.96

.0021 14.05 5

119.94

.0088 4.08 17 442.62

.0010 15.06 6

147.32

.0008 5.01 18 471.93

.0026 16.05 7

206.54

.0013 7.03 19 484.35

.0014 16.48 8

240.34

.0016 8.18 20 530.91

.0008 18.06 9

294.89

.0013 10.03 21 589.88

.0010 20.07 10 323.08

.0025 10.99 22 648.86

.0013 22.07 11 353.88

.0016 12.04 23 707.87

.0013 24.08 12 359.85

.0034 12.24 24 726.50

.0008 24.71 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0178

.0010

/- 0%

.0144

/ 65%

.0105

/ 35%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

CHRG - CHARG. PUMP S INITIAL-B1-6A MOTOR INBOARD AXIAL 0.820 01-APR-93 06:24 i

L. i'f; a.0i6 RPM e 176..

a o

RPS = 29.40 0.012.

~

E

?

g 0.008 g

Y S

n n

0.004 O l' di:t'Pl* TE*ER li l't>~'--

$E 0

200 400 600 000 1000 FREQLENCY IN HZ SPECS.00388 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Initial-B1-6A MOTOR INBOARD AXIAL Date/ Time:

01-APR-93 06:24:23 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

'(Hz)

VALUE VALUE 1

7.04

.0030

.24 13 403.53

.0008 13.73 2

29.50

.0043 1.00 14 471.91

.0035 16.05 3

58.94

.0021 2.00 15 530.92

.0017 18.06 4

88.47

.0020 3.01 16 560.38

.0007 19.06 5

119.98

.0144 4.08 17 565.07

.0008 19.22 6

147.42

.0011 5.02 18 619.38

.0012 21.07 7

176.92

.0023 6.02 19 648.82

.0010 22.07 8

206.46

.0036 7.02 20 678.36

.0012 23.08 9

240.31

.0009 8.17 21 707.88

.0066

'24.08 10 324.41

.0008 11.04 22 726.48

.0014 24.71 11 359.81

.0014 12.24 23 737.36

.0008 25.08 12 383.49

.0008 13.05 24 766.88

.0008-26.09 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0194

.0060

/ 10%

.0099

/ 26%

.0156

/ 64%

FI/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit i

e CHRG - CHARG. PUMP B INITIAL-41-7V GCr# BOX IrFUT VERTICAL 01-APR-93 06:25 LsAi.1:35 0.04 9

RPM = 1768.

o FPS = 29.46 9.03.

E N

e y

e.02.

d Y

~

0.01 b*

Ld 0 W m

^'

0 400 800 1200 1600 2000

[j

[gN FREQUENCY IN HZ SPEC 8

.00633 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Initial-B1-7V GEARBOX INPUT VERTICAL Date/ Time:

01-APR-93 06:25:01 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER.

PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)-

VALUE VALUE 1

29.46

.0065 1.00 13 353.81

.0362 12.01 2

59.07

.0056 2.00 14 376.53

.0018 12.78 3

119.25

.0028 4.05 15 383.29

.0030 13.01 4

161.44

.0040 5.48 16 391.38

.0015 13.28 5

176.76

.0016 6.00 17 403.45

.0047 13.69 6

206.34

.0074 7.00 18 412.91

.0044

.14.01 7

228.61

.0015 7.76 19 441.65

.0028 14.99 8

235.88

.0030 8.01 20 471.85

.0060 16.02 9

242.39

.0031 8.23 21 484.28

.0035 16.44 10 294.53

.0027 10.00 22 530.91

.0015 18.02 11 323.35

.0172 10.98 23 707.81

.0021 24.02 12 346.19

.0016 11.75 24 1452.86

.0036 49.31 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0450

.0015

/

0%

.0427

/ 90%

.0141

/ 10%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit j

I l

o CHRG - CHARG. PUNP B

~ ~

0.630 I

SPECTRUM DISPLAY 01-APR-93 06:25 c'imi. lin e.e2<.

u Q

RPf1 = 1768.

g RPS = 29.46 i

6. 018,

b n

S h e.Osa.

I 9

Y 0N E

0.006 em

+Al--nLII'

- d h^

'L-0 f

0 400 000 1200 1600 2000 FREQUENCY IN HZ SPECS.00454 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Initial-B1-8H GEARBOX INPUT HORIZONTAL Date/ Time:

01-APR-93 06:25:18 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.51

.0045 1.00 13 413.22

.0034 14.03 2

58.99

.0028 2.00 14 442.23

.0027 15.01 3

80.72

.0124 2.74 15 471.84

.0076 16.02 4

146.97

.0038 4.99 16 484.30

.0039 16.44 5

206.45

.0030 7.01 17 619.19

.0025 21.02 6

242.08

.0045 8.22 18 649.75

.0031 22.05.

7 265.40

.0022 9.01 19 678.30

.0034 23.02 8

323.44

.0022 10.98 20 707.82

.0161 24.02 9

353.80

.0097 12.01 21 726.44

.0040 24.66 10 359.21

.0039 12.19 22 737.36

.0022 25.03 11 383.64

.0037 13.02 23 1415.63

.0059 48.05 12 403.55

.0027 13.70 24 1452.83

.0196 49.31 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0358

.0028

/

1%

.0247

/ 48%

.0257

/ 52%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit-

e 1

CHRG - CHARG. PUMP B INITIAL-B1-9A GEARBOX INPUT AXIAL 0.00 y

01-APR-93 06:25 N

PK =

.0828 R

LOAD = 100.0 u

6.06,

n RPM = 1768.

RPS

  • 29.46 g

5 0.05 E

c; 9.04 y

8 0.03, c,

h e e.e2.

[

0.01.j n

o k fN n.

Ld hh.

.d, 0a

[

0 400 800 1200 1600 2000 FREQUENCY IN HZ SPE05.00778 LIST OF SPECTRAL PEAKS

            • .s***************

Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Initial-B1-9A GEARBOX INPUT AXIAL Date/ Time:

01-APR-93 06:25:43 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.49

.0078 1.00 13 646.83

.0130 21.95 2

58.90

.0086 2.00 14 678.27

.0194 23.02 3

88.40

.0040 3.00 15 707.81

.0607 24.02 4

118.24

.0044 4.01 16 726.45

.0142 24.66 5

161.43

.0057 5.48 17 737.19

.0102 25.02 6

206.43

.0079 7.01 18 766.70

.0105 26.02 7

323.15

.0039 10.97 19 796.25

.0052 27.03 8

353.85

.0038 12.01 20 1372.12

.0047 46.57 9

471.84

.0105 16.01 21 1386.15

.0033 47.05 10 484.24

.0049 16.44 22 1415.55

.0058 48.05 11 589.74

.0061 20.02 23 1452.84

.0350 49.31 12 619.35

.0099 21.02 24 1533.57

.0036 52.05 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0828

.0024

/

0%

.0720

/ 76%

.0408

/ 24%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

CHRG - CHARG. PUMP B

,1N171 0-Bi-10V GEARBOX OIL P/P VERT! CAL OR9 j

li. ;*J':

0.016 u

RPM = 1768.

M RPS = 29.46 1

0. 012.

E o

D f

h 0.908.

U.

m, C..

E 1

0. Ou

..b Jh e#

b i.i h.n-

((

0' 400 800 1

".d 1600 2000 FREQUENCY 1". HZ SPECS.00395 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Initial-B1-10V GEARBOX OIL P/P VERTICAL Date/ Time:

01-APR-93 06:26:10 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.45

.0041 1.00 13 1452.80

.0030 49.31 2

59.01

.0050 2.00 14 1533.47

.0029 52.05 3

80.71

.0155 2.74 15 1592.39

.0044 54.05 4

161.45

.0083 5.48 16 1651.34

.0036 56.05 5

206.41

.0066 7.01 17 1680.84

.0057 57.05 6

323.26

.0037 10.97 18 1694.95

.0056 57.53 7

353.88

.0061 12.01 19 1710.41

.0054 58.05 8

471.75

.0043 16.01 20 1739.74

.0030 59.05 9

707.74

.0039 24.02 21 1775.69

.0034 60.27 10 766.75

.0055 26.02 22 1798.93

.0040 61.06 11 1327.11

.0028 45.04 23 1887.23

.0031 64.06 12 1356.52

.0031 46.04 24 1937.04

.0072 65.75 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0309

.0014

/

0%

.0211

/ 47%

.0225

/ 53%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy

. Esc = Quit

e CHRG - C)&RG. PUMP B INITIAL-B1-11H GEARBOX OIL P/P HORIZONTAL

0. 0M i

SPECTRUM DISPLAY 01-APR-93 06:26 0.024,,

OAD=$

N RPM = 1768.

ug RPS = 29.46 0.018,

s C

y 0.012.

O "b

n R*

E 8.006 o

n g

L buh._ lkluo.

ljad dil )

t h h

[gh I

O 400 800 1200 1600 2000 FREQUENCY 1N H2 SPECI.00087 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Initial-B1-11H GEARBOX OIL P/P HORIZONTAL Date/ Time:

01-APR-93 06:26:24 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.71

.0239 2.74 13 471.75

.0064 16.01 2

161.44

.0046 5.48 14 484.17

.0067 16.43 3

176.81

.0030 6.00 15 530.72

.0024 18.01 4

206.43

.0039 7.01 16 645.00

.0024 21.89 5

241.98

.0024 8.21 17 649.97

.0023 22.06 6

323.68

.0026 10.99 18 678.26

.0071 23.02 7

353.88

.0124 12.01 19 707.70

.0186 24.02 8

358.87

.0041 12.18 20 726.38

.0045 24.55 9

383.58

.0040 13.02 21 1371.95

.0025 46.57 10 403.62

.0037 13.70 22 1445.00

.0029 49.05 11 412.81

.0057 14.01 23 1452.67

.0156 49.31 12 442.03

.0025 15.00 24 1474.28

.0027 50.04 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0423

.0046

/

1%

.0277

/ 43%

.0316

/ 56%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

CHRG - CHARG. PUMP B INITIA

.-12A E ARBOX O!L P/P AXTAL 0.10 i

SPECTRUN DISPLAY 01-APR-93 06:26 oAp.j 0.00 A

si

0a 9.06 E

t y 0.04 Y

d r

8 0.02 ci 9

7,

)

a 0.

A '- L -

0 400 000 1200 1600 2000 FREQUENCY IN HZ SPECt.00628 LIST OF SPECTRAL PEAKS

        • w*****************

Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Initial-B1-12A GEARBOX OIL P/P AXIAL Date/ Time:

01-APR-93 06:26:43 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.46

.0065 1.00 13 484.34

.0080 16.44 2

58.91

.0081 2.00 14 530.75

.0058 18.01 3

80.73

.0096 2.74 15 619.17

.0077 21.02 4

118.31

.0040 4.02 16 646.18

.0059 21.93 5

161.40

.0097 5.48 17 649.13

.0065 22.03 6

206.31

.0138 7.00 18 678.18

.0212 23.02 7

235.93

.0050 8.01 19 707.69

.0661 24.02 8

265.44

.0042 9.01 20 726.34

.0191 24.65 9

323.71

.0069 10.99 21 737.10

.0097 25.02 10 353.84

.0251 12.01 22 766.64

.0081 26.02 i

11 412.90

.0078 14.01 23 1415.44

.0053 48.04 12 471.83

.0122 16.01 24 1452.61

.0149 49.30 j

TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0873

.0076

/

1%

.0807

/ 85%

.0324

/ 14%

i F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit I

CHRG - CHARG. PUNP B

,!N I T ! AL-S t-13VGEARBOX OUTPUT VERTICAL 0.04 01-APR-93 06827 PK =.0549 m

h f

0.03.

=

2 RPS = 80.71

.a.

0.02 0

,0 R

A 8

fj E

Y E I 3

g 0.01, fhb L

9.

$mbhT 9.

h 80 0

400 000 1200 1600 2000 FREQUENCY IN N SPECS.05690 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Initial-B1-13V GEARBOX OUTPUT VERTICAL Date/ Time:

01-APR-93 06:27:28 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE-1 29.50

.0031

.37 13 530.92

.0029 6.58 2

58.92

.0042

.73 14 589.85

.0041 7.31 3

80.71

.0178 1.00 15 619.24

.0035 7.67 4

161.40

.0095 2.00 16 648.72

.0034 8.04 5

206.44

.0050 2.56 17 678.23

.0055 8.40 6

323.35

.0131 4.01 18 707.67

.0161 8.77 7

353.84

.0313 4.38 19 726.39

.0086 9.00 8

403.68

.0033 5.00 20 766.74

.0054 9.50 9

412.82

.0090 5.12 21 1129.85

.0032 14.00 10 442.37

.0031 5.48 22 1415.42

.0038 17.54 11 471.80

.0194 5.85 23 1445.04

.0031 17.90 12 484.33

.0117 6.00 24 1452.71

.0116 18.00 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0549

.0057

/

1%

.0315

/ 33%

.0446

/ 66%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

CHRG - CHARG. PUMP B INIT!AL-B1-14H GEARBOX OUTPUT HORIZONTAL

0. H I

SPECTRUM D!$ PLAY 01-APR-93 06:27 PK =

.0433 LOAD = 100.0 o

0.03, i

RPM = 4841.

M N

g RPS = 80.69

.A E

0.02,

3b 8

Y t3 0

{4

[

g 0.01.

Mk Sc, s In11dmT 80.

0 400 000 1200 1600 2000 og y

FREQUENCY IN HZ SPECS.02345 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Initial-B1-14H GEARBOX OUTPUT HORIZONTAL Date/ Time:

01-APR-93 06:27:41 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.69

.0246 1.00 13 484.12

.0037 6.00 2

146.71

.0025 1.82 14 619.08

.0025 7.67 3

161.44

.0038 2.00 15 648.82

.0030 8.'4 4

176.87

.0030 2.19 16 678.17

.0061 8

0 5

206.40

.0035 2.56 17 707.62

.0251 8.77 6

323.52

.0037 4.01 18 726.28

.0067 9.00 7

353.91

.0081 4.39 19 737.04

.0033 9.13 8

359.29

.0032 4.45 20 1371.85

.0024 17.00 9

383.36

.0031 4.75 21 1452.59

.0095 18.00 10 403.62

.0033 5.00 22 1533.33

.0040 19.00 11 413.11

.0045 5.12 23 1562.75

.0029 19.37 12 471.85

.0090 5.85 24 1710.18

.0026 21.19 1

TOTAL MAG SUD5YNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS l

.0433

.0048

/

1%

.0289

/ 45%

.0319

/ 54%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit i

I l

.\\

-i CHRG - CHARG. PUMP B

!NITIAL-Bi-15A riApBOX OUTPUT AXIAL 0.08 SPCCTRUM DisPLgy 01-APR-93 06:28 0.07 g

l h

PK =.eos<

LOAD = 100.0 o 0.06.

RPM

  • 1768.

h!

RPS = 29.46 E

g 0.04.

g n

8 0.03.

m g'

g y e.0a.

(

P 0.01,, on bil

  • ,coSMYl mN.@d5$P 0

a fy$

O 400 000 1200 1600 2000 FREQUENCY IN HZ SPECS.01062 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Initial-B1-15A GEARBOX OUTPUT AXIAL Date/ Time:

01-APR-93 06:28:08 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.50

.0084 1.00 13 678.27

.0211 23.02 2

58.99

.0098 2.00 14 707.69

.0609 24.02 3

80.69

.0112 2.74 15 726.26

.0179 24.65 4

161.38

.0124 5.48 16 737.18

.0106 25.02 5

206.42

.0154 7.01 17 766.62

.0061 26.02 6

353.79

.0115 12.01 18 796,10

.0069 27.02 7

471.67

.0080 16.01 19 1356.42

.0068 46.04 8

484.12

.0054 16.43 20 1415.29

.0091 48.04 9

589.87

.0074 20.02 21 1444.93

.0059 49.04 10 619.18

.0131 21.02 22 1452.63

.0349 49.30 11 645.98

.0075 21.93 23 1474.19

.0061 50.04 12 649.71

.0100 22.05 24 1856.32

.0053 63.01 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0894

.0023

/

0%

.0766

/ 73%

.0461

/ 27%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

l CHRG - CHARG. PUMP B INIT!AL-91-16V Pt.P1P !NBD vt'RTICAL 0.14 01-APR-93 06:28 l.

0.12.

pg.

,g171 l

N LOAD = 100.0 RPM = 4820.

,f 0.18, RPS = 80.47

}

e.es.

l O 0.06.

8 Na 0.e4

  1. (3 0.02.

n Liv u A _v 0

Ih h

i 0

400 000 1200 1600 2000 c

FREQUCNCY IN H2 SPECS.09671 1

LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Initial-B1-16V PUMP INBD VERTICAL Date/ Time:

01-APR-93 06:28:29 Amplitude Units:

IN/SEC PK i

i PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO..

(Hz)

VALUE VALUE 1

80.69

.1017 1.00 13 403.63

.0073 5.02 2

146.67

.0107 1.82 14 471.86

.0036 5.86.

3 161.38

.0317 2.01 15 484.20

.0054 6.02 I

4 176.67

.0051 2.20 16 645.41

.0084 8.02 5

184.18

.0026 2.29 17 708.25

.0042 8.80

.i 6

?O5.63

.0116 2.56 18 726.18

.0044 9.02 7

218.66

.0097 2.72 19 790.83

.0025 9.83 8

227.74

.0061 2.83 20 807.00

.0035 10.03 9

235.74

.0054 2.93 21 887.19

.0039 11.03 10 242.05

.0261 3.01 22 1452.50

.0106 18.05 11 322.81

.0221 4.01 23 1533.19

.0038 19.05 12 353.74

.0036 4.40 24 1936.55

.0059 24.07 i

TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.1171

.'0025

/

0%

.1125

/ 92%

.0327

/

8%

]

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit l

J

,-s

+

CHRG - CHARG. PUMP B INITIAL-Bt-17H PUMP !N3D HORIZONTAL 3

et-APR-93 e6:28 PK =

.2289 e.24 LOAD = tee.e

.g f

$$ " 8e b a

e. to.

E t

y e.12,

b

~

e 3 h.

e.e6 2

0 dd vo_omom____mvTTm-m--

e E g g se g e

aos see 12ee 1688 2008 FREQUENCY IN H2 SPECS

.'203 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Initial-B1-17H PUMP INBD HORIZONTAL Date/ Time:

01-APR-93 06:28:59 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.69

.2134 1.00-13 220.88

.0032 2.75 2

116.19

.0029 1.44 14 226.38

.0031 2.81 3

123.36

.0049 1.53 15 242.06

.0538 3.01-4 132.90

.0058 1.65 16 258.23

.0033 3.21 5

140.76

.0061 1.75 17 322.78

.0338 4.01 6

146.65

.0256 1.82 18 403.43

.0084 5.01 7

161.39

.0275 2.01 19 484.21

.0043 6.02 8

176.38

.0044 2.19 20 645.82

.0035 8.03 9

185.86

.0036 2.31 21 806.71

.0046 10.03 10 196.34

.0049 2.44 22 1371.63

.0089 17.05 11 206.13

.0077 2.56 23 1452.30

.0165 18.05 12 213.26

.0039 2.65 24 1532.99

.0145 19.05 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.2289

.0109

/

0%

.2247

/ 96%

.0422

/

3%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

i.

CHRG - CHARG. PUMP B INITIAL-B1-10A FU1P INBD AX!AL 0.12 01-APR-93 06:29 0.10 PK =.1154 LOAD = 100.0 "A : 3"b 0.08.

r 0.06 "D

~

{

8 y

0.04 a

a x

k C

0.02.

g n

0,,

ER 9 T 9 r,,,

n,.s n

-JPdr197

$E 8

0 400 000 1200 1600 2000 FREQUENCY IN HZ SPECS.05063 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Initial-B1-18A PUMP INBD AXIAL Date/ Time:

01-APR-93 06:29:42 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE-1 80.69

.0532 1.00 13 806.87

.0054 10.03 2

146.64

.0103 1.82 14 888.47

.0043 11.04 3

161.41

.0152 2.01 15 1371.71

.0164 17.05 4

176.86

.0050 2.20 16 1452.46

.0906 18.05 5

226.64

.0038 2.82 17 1533.23

.0200 19.05 6

241.99

.0103 3.01 18 1613.48

.0040 20.05 7

322.82

.0132 4.01 19 1643.50

.0040 20.42 8

403.50

.0071 5.01 20 1651.70

.0040 20.53 9

471.49

.0045 5.86 21 1661.08

.0046 20.64 10 483.91

.0054 6.01 22 1666.27

.0045 20.71 11 645.56

.0044 8.02 23 1695.70

.0050 21.07 12 726.13

.0041 9.02 24 1936.50

.0063 24.07 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.1154

.0027

/

0%

.0729

/ 40%

.0894

/ 60%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy

' Esc = Quit

CHRG - CHrdG. PUMP B 1NITIAL-Bi-19V PUMP OUTBOARD VfRTICAL 0.08 3

01-APR-93 06830 PK

.0997

=

M LOAD = 100.0

@ 0.06.J.

RPM = 4828.

Res - 80.47 S 0.05.

E 0.e4 g

.q g

t 8

0.03.

9 Y

5 g

0.02. p n

f 0.01, n

d h o m es a 9 T Y a r, - ~

g m

r 0

400 000 1200 1600 2000 ORDRt

.994 FREQUENCY IN HZ SPECS.05486 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Initial-B1-19V PUMP OUTBOARD VERTICAL Date/ Time:

01-APR-93 06:30:08 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.37

.0044

.37 13 205.70

.0053 2.56 2

58.94

.0061

.73 14 220.44

.0040 2.74 3

66.01

.0037

.82 15 228.62

.0036 2.84 4

80.73

.0580 1.00 16 242.15

.0102 3.01 5

88.48

.0334 1.10 17 256.54

.0037 3.19 6

102.89

.0048 1.28 18 322.78

.0146 4.01 7

117.28

.0087 1.46 19 471.64

.0075 5.86 8

132.15

.0153 1.64 20 484.43

.0105 6.02 9

146.77

.056,2 1.82 21 645.62

.0088 8.02' 10 161.50

.0228 2.01 22 707.08

.0035 8.79 11 176.45

.0082 2.19 23 726.16

.0053 9.02 12 190.93

.0033 2.37 24 1452.48

.0108 18.05 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0997

.0089

/

1%

.0665

/ 44%

.0737

/ 55%

Fl/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

1 J

CHRG - CHARG. PUMP B l

INITIAL-B1-20H PUMP OUTBOARD FORIZONTAL 0.09 1

$PECTRUM Di$ PLAY 01-APR-93 06:00 OAD=$0 N

o 0.06..

RPM = 4828.

RPS = 00.47 0 e5.

5 G

l 0.04 g

0.03, y 0.0a.

]

0.01.

n 0

O PM- _ Qo,,9an9' ri m n m o ggl 88g 0

400 808 see0 2600 200e FREQUENCY IN HZ SPEC 1.05479 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Initial-B1-20H PUMP OUTBOARD HORIZONTAL Date/ Time:

01-APR-93 06:30:21 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.69

.0576 1.00 13 388.57

.0046 4.83 2

96.71

.0031 1.20 14 403.69

.0056 5.02 3

108.49

.0065 1.35 15 439.16

.0031 5.46-4 118.33

.0067 1.47 16 484.09

.0059 6.02-5 131.50

.0047 1.63 17 501.44

.0034 6.23 6

146.74

.0348 1.82 18 506.37

.0030 6.29 7

161.36

.0435 2.01 19 616.47

.0033 7.66 8

177.09

.0043 2.20 20 645.58

.0035 8.02 9

205.69

.0041 2.56 21 726.25

.0045 9.03 10 212.84

.0034 2.65 22 806.82

.0046 10.03 11 242.06

.0111 3.01 23 1452.37

.0138 18.05 12 308.14

.0034 3.83 24 1533.13

.0070 19.05 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0871

.0059

/

0%

.0741

/ 72%

.0453

/ 27%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

CHRG - CHARG. PUMP B

~~

0.10 g

e.e6 a

E

"% : a b o

5

0. 06,

5 t

h 0.04,

Y 0.02.

9 3

3 $

3 d

.L.

T-,nmnvn-o-nnw 88 N

((

4 0

400 800 1200 1600 2000 FREQUENCY IN HZ SPECi.00300 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Initial-B1-21A PUMP OUTBOARD AXIAL Date/ Time:

01-APR-93 06:30:38 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER-NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.65

.0040 1.00 13 483.93

.0079 6.01 2

88.48

.0060 1.10 14 593.96

.0034 7.38 3

146.81

.0063 1.82 15 645.94

.0053 8.03 4

161.37

.0118 2.01 16 660.61

.0031 8.21 5

176.76

.0036 2.20 17 676.17

.0028 8.40 6

206.25

.0036 2.56 18 707.93

.0062 8.80 7

242.06

.0074 3.01 19 726.44

.0100 9.03 8

322.78

.0088 4.01 20 794.06

.0021 9.87 9

413.00

.0041 5.13 21 806.94

.0029 10.03 10 443.28

.0022 5.51 22 1452.62

.0667 18.05 11 460.91

.0028 5.73 23 1533.35

.0117 19.06 12 471.58

.0071 5.86 24 1936.83

.0027 24.07 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0769

.0163

/

5%

.0356

/ 21%

.0662

/ 74%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

l i

\\

CHRG - CHARG. PUMP B int ! -Bi-23v Ott & WICA 0.030 y

p 01-APR-93 06:32 k

VK =.0473 0.024 "

LOAD = 100.0 EE~ U#b g

a

0. 019.

,1 b

%* 7 C

M$

] 0.012.

n 0.006,

0 ime,-mi 29 9 r> i 9

80[

0 400 000 1200 1600 2000 FREQUENCY IN H2 SFEC8.02173 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B

. Meas. Point:

Initial-B1-22V OIL PUMP VERTICAL Date/ Time:

01-APR-93 06:32:08 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.73

.0230 1.00 13 308.32

.0061 3.83 2

88.39

.0140 1.10 14 322.99

.0089 4.01 3

93.80

.0028 1.17 15 389.34

.0029 4.84 4

102.50

.0032 1.27 16 403.50

.0054 5.01 5

109.41

.0030 1.36 17 411.97

.0032 5.12 6

116.93

.0089 1.45 18 431.15

.0037 5.36 7

131.69

.0116 1.64 19 433.95

.0038 5.39 8

138.85

.0028 1.73 20 439.01

.0033 5.46 9

147.00

.0137 1.83 21 448.75

.0030 5.58 10 242.11

.0144 3.01 22 454.33

.0034 5.65 11 278.81

.0032 3.46 23 471.92

.0103 5.86 12 293.56

.0060 3.65 24 484.04

.0140 6.02 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0475

.0027

/

0%

.0327

/ 47%

.0344

/ 52%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

T CHRG - CHARG, PUMP B INITIAL-B1-23H O!L PUMP HORIZONTAL OM g

01-APR-93 06 32 PK =. 05%

s w:w 0.0, d

RPS = 80.47 n

s

e. e2.

g g

=

f 3

c r 0 ai -

n,,

n n

n g,

r, t

-r*

- w

$g 80 0

400 000 1200 1600 2000 FREQUENCY IN HZ SPECS.0245L LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Initial-B1-23H OIL PUMP HORIZONTAL Date/ Time:

01-APR-93 06:32:27 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.76

.0260 1.00 13 403.62

.0110 5.02 2

110.98

.0043 1.38 14 413.86

.0040 5.14 3

116.55

.0035 1.45 15 441.10

.0036 5.48 4

131.96

.0036 1.64 16 471.74

.0044 5.86 5

146.73

.0226 1.82 17 484.45

.0077 6.02 6

161.38

.0135 2.01 18 645.84

.0057 8.03 7

242.13

.0093 3.01 19 708.40

.0046 8.80 8

293.64

.0046 3.65 20 726.28

.0038 9.03 9

322.17

.0053 4.00 21 806.92

.0039 10.03 10 353.58

.0032 4.39 22 1372.16

.0035 17.05 11 373.73

.0035 4.64 23 1452.99

.0285 18.06 12 391.08

.0065 4.86 24 1533.65

.0163 19.06

)

TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0596

.0082

/

2%

0378

/ 40%

.0452

/ 58%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit l

9 CHRG - CHARG. PUNP B INITIAL-Bi-24A O!L PUNP AXIAL 0.12 01-APR-93 06:32 0.10,

PK =

.1374 E

LOAD = 100.0 1

RPM = 4820.

og n

RPS = 80.47 0.08.

j r

ca 0.06,,

g 0.04 g

E 5

n 0.82.

o n

0. JM %d 81 h "

$8 0

400 800 1200 1600 2000 FREQUENCY IN H2 SPEC 8.04328 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Initial-B1-24A OIL PUMP AXIAL Date/ Time:

01-APR-93 06:32:48 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.74

.0458 1.00 13 615.78

.0083 7.65 2

88.43

.0210 1.10 14 630.89

.0082 7.84 3

117.06

.0067 1.45 15 646.33

.0072 8.03 4

131.70

.0078 1.64 16 707.95

.0148 8.80' 5

146.76

.0543 1.82 17 726.40

.0238 9.03 6

161.40

.0246 2.01 18 1291.50

.0081 16.05 7

323.31

.0088 4.02 19 1452.88

.0859 18.06 8

472.14

.0137 5.87 20 1518.89

.0065 18.88 9

484.44

.0275 6.02 21 1540.94

.0077 19.16 10 531.15

.0071 6.60 22 1614.44

.007" 20.06 11 564.26

.0092 7.01 23 1775.55

.0068 22.07 12 588.69

.0084 7.32 24 1937.11

.0091 24.07 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.1374

.0240

/

3%

.0723

/ 28%

.1144

/ 69%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

(

CHRG - CHARG. PUNP B INIT! AL41-25A GEARBOX INLET AX1AL HIGH FREQ 0.12 1

SPECTRUM DISPLAY 01-APR-93 06 34 6.10,

PK =.1314 LOAD = 100.0 A

RPM = 1768.

u y

0. 00.

E

"=- c' s E

%j 0.06,

g 9

( 0.04,

n r

0.02.

J E

h f

Ok 1

a d

= ~ -

d 0

000 2000 3000 4000 5000 6000 FREQUENCY IN H2 SPECS.08368 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Initial-B1-25A GEARBOX INLET AXIAL HIGH FREQ Date/ Time:

01-APR-93 06:34:30 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.70

.0097 1.01 13 1415.81

.0070 48.05 2

59.78

.0086 2.03 14 1453.13

.0204 49.32 3

161.27

.0079 5.47 15 1473.62

.0066 50.02 4

207.16

.0115 7.03 16 2772.47

.0088 94.10 5

471.48

.0087 16.00 17 2802.03

.0209 95.10 6

620.21

.0089 21.05 18 2831.54

.0394 96.11 7

646.88

.0070 21.96 19 2861.05

.0081 97.11 8

678.20

.0239 23.02 20 2890.49

.0373 98.11 9

707.88

.0836 24.03 21 2919.97

.0119 99.11 10 726.56

.0252 24.66 22 3008.47

,0102 102.11 11 766.51

.0149 26.02 23 3037.78

.0069 103.11 12 796.16

.0104 27.02 24 3067.44

.0518 104.11 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.1314 Undefined /

0%

.1269

/ 93%

.0242

/

3%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

'(

!NITIAL- -26Y IPINf* HIGH FREQ

0. F g

O!-APR-93 06435 D=$

h

8. 05.

p r

0.04,

0.03.

W 0.02.

5 0.01,

O I

A A"---

I FREQt 1450.0 1000 2000 3000 4000 5000 ORDRs 10.02 FREQUENCY IN H2 SPECt.04649 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Initial-B1-26V PIPING HIGH FREQ Date/ Time:

01-APR-93 06:35:02 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY-PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

1208.60

.0015 15.02 13 2260.81

.0024 28.10-2 1369.27

.0038 17.02 14 2338.38

.0011 29.06 3

1453.09

.0470 18.06 15 2418.56

.0029 30.06 4

1532.47

.0074 19.04 16 2502.59

.0013 31.10 5

1594.94

.0035 19.82 17 2820.52'

.0012 35.05 6

1737.23

.0036 21.59 18 2906.71

.0013 36.12 7

1763.85

.0038 21.92 19 2986.17

.0013 37.11 8

1849.18

.0023 22.98 20 3391.39

.0011 42.15 9

1937.50

.0020 24.08 21 3551.87

.0008 44.14 10 2013.96

.0012 25.03 22 3790.90

.0007 47.11 11 2094.46

.0028 26.03 23 3875.75

.0015-48.17 12 2163.16

.0011 26.88 24 4360.27

.0009 54.19 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0489 Undefined /

0%

Undefined /

0%

Undefined /

0%

F1/ Enter = Accept F2= Paging is OFF F7=Titic F9= Copy Esc = Quit 1

a CHRG - CHARG. PUMP B r!NAL-B1 -tv MOTOR OUTBOARD VERTICAL ON g

01-APR-93 16153 d.005 PK =.0087 e

LOAD = 100.0 1

8 RPM = 1764.

RPS = 29.40 a

m

,Q 5

0.003, 5

i h 9.002.

r 0.001 l)

'N

'Y N'25 O

I ma-

[h 0

200 400 600 800 1000 FREQUENCY IN HZ SPECS.00305 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Final-B1

-1V MOTOR OUTBOARD VERTICAL Date/ Time:

01-APR-93 16:53:32 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

6.60

.0007

.22 13 359.81

.0018 12.24 2

10.55

.0007

.36 14 383.17

.0006 13.03 3

29.50

.0034 1.00 15 412.79 4.33E-04 14.04 4

58.98

.0031 2.01 16 471.79

.0017 16.05 5

80.64 4.14E-04 2.74 17 484.20

.0021 16.47 6

85.38 4.26E-04 2.90 18 530.77

.0014 18.05 7

88.44

.0012 3.01 19 560.37 4.56E-04 19.06 8

119.97

.0041 4.08 20 619.2f.

3.99E-04 21.06 9

147.94

.0008 5.03 21 678.21 3.98E-04 23.07 10 177.00

.0008 6.02 22 707.67

.0026 24.07 11 323.25

.0014 11.00 23 726.32

.0009 24.71 12 353.86

.0018 12.04 24 807.05

.0007 27.45 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0087

.0012

/

2%

.0061

/ 48%

.0062

/ 50%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

CHRG - CHARG. PUMP B FINAL-B1

-2H MOTOR OUTBOARD HORIZONTAL 0.012 i

SPECTRUM DISPLAY 01-APR-93 16 53 0.010.

S PK =

.0157 4

LOAD - 300.0 1

8 RPM = 1764.

o n

RPS = 29.40 r

0.006 5

k

~~

h 0.004 g

E k

O.002.

n y, n

n 0 ihd $Yo OWU

'b N

^"

FREQs 30.00 0

200 400 600 000 1000 ORDRs 1.021 FREQUENCY IN HZ SPECS

.00448 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Final-B1

-2H MOTOR OUTBOARD HORIZONTAL Date/ Time:

01-APR-93 16:53:56 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE.

1 10.67

.0006

.36 13 294.74

.0017 10.03.

2 29.48

.0050 1.00 14 300.31

.0005 10.22 3

50.78 4.33E-04 1.73 15 324.20

.0022 11.03 4

58.97

.0092 2.01 16 353.81

.0018 12.04 5

65.67 4.90E-04 2.;13 17 359.84

.0086 12.24 6

80.73

.0006 2.75 18 374.62 4.86E-04 12.74 7

88.45

.0015 3.01 19 383.33

.0010 13.04 8

119.89

.0048 4.08 20 412.82

.0006 14.04 9

148.14 4.88E-04 5.04 21 484.19

.0009 16.47 10 206.48

.0011 7.02 22 530.76

.0006 18.06 11 235.90

.0006

8. 0.2 23 707.66

.0010 24.07 12 239.87

.0024

8. lti 24 806.94

.0007 27.45 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0157

.0026

/

3%

.0115

/ 54%

.0104

/ 44%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy

_ Esc = Quit

i CHRG - CHARG. PUMP B FINAL-Bt

-3A MOTOR OUTBOARD AXIAL 0.020 g

01-APR-93 16:54 FT =

.0158 0.016 LOAD = 100.0 9

RPM = 1764.

u RPS = 29.40 1

~

- 0.012,

5

$g

0. 00s.

k 0.004,

k bmSbb--ocsph -

0 f0 O

200 400 600 800 1000 02 FREQUENCY IN H2 SPECS.00258 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Final-B1

-3A MOTOR OUTBOARD AXIAL Date/ Time:

01-APR-93 16:54:10 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.47

.0029 1.00 13 206.54

.0008 7.03 2

59.03

.0020 2.01 14 235.90

.0009 8.02 3

77.86

.0005 2.65 15 239.77

.0008 8.16 4

88.22

.0011 3.00 16 324.40

.0007 11.04 5

90.66

.0007 3.08 17 330.47

.0008 11.24-6 104.25 4.85E-04 3.55 18 353.86

.0054 12.04 7

119.94

.0126 4.08 19 359.84

.0039 12.24 8

148.16

.0008 5.04 20 403.53

.0005 13.73 9

161.47

.0008 5.49 21 412.82

.0007 14.04 10 167.03 4.49E-04 5.68 22 471.79

.0009 16.05 11 176.90

.0021 6.02 23 484.22

.0007 16.47 12 181.93

.0005 6.19 24 530.79

.0006 18.06 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0158

.0029

/

3%

.0088

/ 31%

.0128

/ 66%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

0.016 i

DI L'. n't g ' .

s y

"R : s ':a 5

e E

R 0.008,

n n

y d9 g

0. 004.

n n

ci C

e n

s w % $

)

e j

T9

,J 2% 1 0

200 400 600 800 1000 kg h$

FREQUENCY IN H2 SPf.Cs.00233 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Final-B1

-4V MOTOR INBOARD VERTICAL Date/ Time:

01-APR-93 16:54:38 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

11.58

.0023

.39 13 530.78

.0025 18.06 2

29.46

.0029 1.00 14 560.32

.0018 19.06 3

58.95

.0012 2.01 15 589.74

.0019 20.06 4

88.46

.0019 3.01 16 619.26

.0045 21.07 5

119.97

.0106 4.08 17 648.70

.0036 22.07 6

324.25

.0023 11.03 18 667.28

.0011 22.70 7

353.86

.0079 12.04 19 678.22

.0040 23.07 8

383.08

.0027 13.03 20 707.72

.0101 24.08 9

403.48

.0022 13.73 21 726.37

.0036 24.71 10 412.83

.0034 14.04 22 766.72

.0015 26.08 11 471.79

.0024 16.05 23 796.18

.0014 27.08 12 484.23

.0034 16.47 24 807.04

.0012 27.45 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0216

.0033

/

2%

.0124

/ 33%

.0174

/ 65%

FI/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

e CHRG - CHARG. PUNP B FINAL-B1

-5H NOTOR INROARD HORIZONTAL 0.016 i

SPECTRUM DISPLAY 01-APR-93 16:55 PK =.0184 LOAD = 100.0 u 0.012,

d RPM = 1764.

5 RPS = 29.40 n

f4 O

d 000, g

o 5

k t

n) g C.004 D

n n

n iT Oh- -

JJ

'9 9

W 0

t h,$

hk 0

200 400 600 000 1000 FREQUENCY IN HZ SPECS.00602 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Final-B1

-5H MOTOR INBOARD HORIZONTAL Date/ Time:

01-APR-93 16:55:02 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.49

.0067 1.00 13 391.53

.0010 13.32 2

58.97

.0112 2.01 14 403.43

.0014 13.72 3

88.47

.0019 3.01 15 412.82

.0015 14.04 4

119.94

.0081 4.08 16 442.38

.0010 15.05 5

147.67

.0008 5.02 17 471.84

.0028 16.05 6

206.51

.0016 7.03 18 484.28

.0017 16.47 7

239.90

.0015 8.16 19 560.31

.0008 19.06 8

294.89

.0015 10.03 20 619.28

.0008 21.07 9

324.16

.0024 11.03 21 648.76

.0010 22.07 10 353.83

.0018 12.04 22 678.22

.0008 23.07 11 359.82

.0044 12.24 23 707.74

.0023 24.08 12 383.23

.0024 13.04 24 726.36

.0013 24.71 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0184

.0022

/

2%

.0147

/ 64%

.0107

/ 34%

i F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

)

l

r!NAL-B1 A

OR O D AXfAL

0. M i

SPECTRUM DISPLAY 01-APR-93 16:55 0.016 0AD=i "3 : i;";

5

0. 012.

E

$g 0.608 m

9 v

e E

1 i

i

0. 00<

n n

0 l Sc29 DRdT it'-'--- - -

f0 0

200 400 600 000 1000 FREQUEfCY IN HZ SPECS.00434 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Final-B1

-6A MOTOR INBOARD AXIAL Date/ Time:

01-APR-93 16:55:28 Amplitude Units:

IN/SEC PK-PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.47

.0049 1.00 13 359.82

.0021 12.24' 2

59.00

.0028 2.01 14 383.23

.0008 13.04 3

85.54

.0007 2.91 15 471.84

.0038 16.05 4

88.48

.0016 3.01 16 484.30

.0008 16.48 5

119.93

.0150 4.08 17 530.82

.0022 18.06 6

147.66

.0013 5.02 18 564.89

.0012 19.22 7

176.93

.0024 6.02 19 589.80

.0010 20.06 8

193.53

.0008 6.58 20 619.34

.0009 21.07 9

206.42

.0035 7.02 21 648.83

.0015 22.07 10 240.18

.0009 8.17 22 678.24

.0011' 23.07 11 324.26

.0010 11.03 23 707.78

.0053 24.08 12 353.88

.0007 12.04 24 726.39

.0015 24.71 TOTAL MAC SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0206

.0074 '/ 13%

.0108

/ 28%

.0159

/ 59%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit i

l

0.016 I

SPECTRUM DISPLAY OL-APR-93 16:56 A

OAD = 1 e

0.012,

RPM = 1768.

y h

k u

RPS = 29.46 8'

_2 ca

,h N

4 * * *** n 9?

k i:

g 0.004 r

gftis

I g

h I3lle' oN E

'E 44 3hf I

0 5

F 0

400 000 3200 1600 2000 OR 0

FREQUENCY IN H2 spgc

.00559 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Final-B1

-7V GEARBOX INPUT VERTICAL Date/ Time:

01-APR-93 16:56:02 Amplitude. Units:

IN/SEC. PK PEAK FREQUENCY PEAK ORDER PEAK-FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO. _

(Hz)

VALUE VALUE 1

29.49

.0057 1.00 13 726.30

.0037 24.65 2

58.94

.0034 2.00 14 796.02

.0026 27.02-3 161.33

.0032 5.48 15 855.44-

.0021 29.03 4

206.47

.0060 7.01 16 968.45

.0026 32.87-5 235.81

.0024 8.00 17 1452'.58

.0043

-49.30-6 242.08

.0035 8.22 18 1680.86

.0030-57.05 7

323.46

.0063 10.98 19 1775.37

.0044:

60.25 8

353.87

.0119 12.01 20 1828;22

.0025 62.05 9

471.71

.0028 16.01 21 1856.56

.0039

'63.01 10 484.38

.0035 16.44 22 1887.39

.0031' 64.06 11 678.31

.0046 23.02 23 1936.66

.0026 65.73 12 707.69

.0106 24.02 24 1946.22

.0034 66.05 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS ~

NONSYNCHRONOUS-

.0270

.0018

/

0%

.0235 '/ 76%-

.0132

/ 24%

'F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

e CHPG - OMRG. FtJMP B 0.020

' I '

I I

DI

.0340 k

PK =

0.016.

g' Q'

LOAD = 100.0 u

K RPM = 1768.

RPS = 29.46 n

8.012,.*

e 9S y 0.008.

0$

g n n 0.004.

n r g, Ot OR.

MALwY b

hl

[h I

O 400 800 1200 1600 2000 FREQUENCY I.4 H2 SPEC 8

.00280

.i LIST OF SPE' 'RAL PEAKS

                                    • ww**

Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Final-B1

-8H GEARBOX INPUT HORIZONTAL Date/ Time:

01-APR-93 16:56:18 Amplitude Units:

IN/SEC PK i

PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.48

.0029 1.00 13 484.34

.0055 16.44 2

58.87

.0035 2.00 14 678.35

.0026 23.02 3

80.72

.0112 2.74 15 707.71

.0141 24.02 4

146.99

.0040 4.99 16 726.21

.0056 24.65 5

206.45

.0037 7.01 17 1415.58

.0034 48.04 6

353.79

.0084 12.01 18 1452.74

.0142 49.30 7

360.16

.0046 12.22 19 1504.26

.0029 51.05 8

383.47

.0033 13.01 20 1533.34

.0039 52.04 9

403.33

.0029 13.69 21 1563.23

.0034 53.05 10 413.00

.0030 14.02 22 1621.72

.0029 55.04 11 441.93

.0028 15.00 23 1651.27

.0024 56.04 12 471.73

.0075 16.01 24 1856.45

.0028 63.01 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0340

.0089

/

7%

.0234

/ 47%

.0230

/ 46%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

CHRG - CHARG. PUMP B FINAL-B1

-9A GEARBOX INPUT AXIAL

0. R 01-APR-93 16:56 9.le.

PK =

.1054 A

LOAD = 100.0 f

RPM = 1768.

u

{ 0.0a,

Res = es.46 A

3 0.06,

5 5

h 0.04 a

s y

e4 e

e. ee.

hioA lsm.a.an O

F 0

400 000 1200 1600 2000 FREQUENCY IN HZ SPECS.01347 LIST OF SPECTRAL PEAKS Machine-(CHRG) CHARG. PUMP B Meas. Poirit.

'inal-B1

-9A GEARBOX INPUT AXIAL Date/ Time:

' 7 -f W-4 3 16:56:34 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAN ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.48

.0138 1.00 13 726.39

.0395 24.65 2

58.94

.0124 2.00 14 737.11

.0142 25.02 3

118.11

.0051 4.01 15 766.59

.0223 26.02 4

161.40

.0093 5.48 16 796.23

.0163 27.02 5

206.38

.0131 7.00 17 855.14

.0053 29.02 6

242.02

.0046 8.21 18 1149.84

.0043 39.02 7

323.16

.0067 10.97 19 1452.81

.0166 49.31 8

353.80

.0068 12.01 20 1533.30

.0065 52.04 9

619.17

.0048 21.01 21 1798.90

.0058 61.05 10 649.52

.0067 22.04 22 1828.64

.0055 62.06 11 678.39

.0182 23.02 23 1856.60

.0069 63.01 12 707.69

.0790 24.02 24 1936.94

.0090 65.74 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.1054

.0040

/

0%

.0927

/ 77%

.0500

/ 22%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy

. Esc = Quit-4 j

.i l

i i

1

FINAL-B1 -

B P/P VERTICAL 0.020 i

01-4PR-93 16t56 t%. ;*J8; 0.016 m W

i "R : i;'h a

n 0.012,

C..

in n

j 0.000 0.004 ci Y$b b

Y 4

.L e

f0 0

400 800 1200 1600 2000 0

FREQUENCY IN H2 SPEC

.00460 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Final-B1

-10V GEARBOX OIL P/P VERTICAL Date/ Time:

01-APR-93 16:56:56 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.46

.0047 1.00 13 726.37

.0038 24.65 2

59.11

.0046 2.01 14 766.83

.0049 26.03 3

80.71

.0143 2.74 15 807.09

.0031 27.39 4

161.49

.0089 5.48 16 1327.G5

.0029 45.04 5

206.51

.0067 7.01 17 1533.50

.0031 52.05 6

241.99

.0050 8.21 18 1680.99

.0036 57.05 7

323.41

.0034 10.98 19 1710.44

.0045 58.05 8

353.87

.0049 12.01 20 1798.87

.0035 61.05 9

403.60

.0032 13.70 21 1856.57

.0030 63.01 10 471.90

.0048 16.02 22 1886.97

.0037 64.04 11 484.17

.0033 16.43 23 1937.07

.0112 65.74 12 707.77

.0088 24.02 24 1946.25

.0043 66.05 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0327

.0058

/

3%

.0216

/ 44%

.0238

/ 53%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

1 CHRG - CW.RG. PUMP B FINN -51

-11H GEARBOX O!L P/P HORIZONTAL

0. 0%

1 SPECTRUM DICPLJW 01-APR-93 16:57 MD = $0 0.024 -

A i

"% ; Wh 5

9.019,

c.;

b 9

i 0

~

E O$

k 8 0.012 "w

0.006.

E# w-nd b

O u

I

$$l O

400 800 1200 1600 2000 FREQUENCY IN H2 SPECS.00069 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Final-B1

-11H GEARBOX OIL P/P HORIZONTAL Date/ Time:

01-APR-93 16:57:10 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.71

.0215 2.74 13 678.13

.0042 23.02 2

161.27

.0040 5.47 14 707.61

.0126 24.02 3

176.63

.0034 5.99 15 726.34

.0051 24.65 4

206.34

.0038 7.00 16 1149.98

.0033 39.03 5

323.98

.0035 11.00 17 1452.72

.0144 49.30 6

353.82

.0145 12.01 18 1533.61

.0033 52.05 7

359,48

.0043 12.20 19 1562.86

.0033 53.04 8

383.04

.0033 13.00 20 1613.78

.0032 54.77 9

403.47

.0038 13.69 21 1694.75

.0036 57.52 10 413.05

.0056 14.02 22 1775.53

.0049 60.26 11 471.80

.0069 16.01 23 1856.54

.0037 63.01 12 484.23

.0116 16.43 24 1936.71

.0047 65.73 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0433

.0084

/

4%

.0266

/ 38%

.0331

/ 58%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

4 CHRG - CHARG. PUMP B FINAL-B1

-1PA GEARBOX O!L P/P AX1AL g7 01-APR-93 16:57 OAD=$

d 0.05.

d n

5 0.04 e

0.03.

h

.0a

' ci

'l 0

0 g

8 E

N 0.01.

O h

Ak WC 1

^

f0 0

400 000 1200 1600 2000 g

FREQUENCY IN H2 SPECS.00860 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Final-B1

-12A GEARBOX OIL P/P AXIAL Date/ Time:

01-APR-93 16:57:28 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.47

.0089 1.00 13 484.27

.0152 16.44 2

59.13

.0093 2.01 14 530.69

.0064 18.01 3

80.72

.0088 2.74 15 564.69

.0043 19.17 4

161.40

.0120 5.48 16 619.52

.0060 21.03 5

206.35

.0169 7.00 17 649.39

.0062 22.04 6

235.79

.0058 8.00 18 678.31

.0158 23.02 7

242.35

.0053 8.22 19 707.74

.0510 24.02 8

265.38

.0047 9.01 20 726.33

.0173 24.65 9

323.61

.0079 10.98 21 737.24

.0080 25.02 10 353.86

.0279 12.01 22 766.50

.0071 26.01 11 412.70

.0064 14.01 23 1452.84

.0188 49.31 12 471.71

.0127 16.01 24 1680.93

.0060 57.05 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0890

.0400

/ 20%

.0697

/ 61%

.0384

/ 19%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

CHRG - CHARG. PUMP B FINAL-B1

-13V GEARBOX OUTPUT VERTICAL

0. 0%

3 SPECTRUM DISPLAY 01-APR-93 16:50 0.030.

PK

.0499

=

l-k % "I n 'i' m

N RPS = 80.69 g

5

)

0.018.I e

a 8

9 y 0.e a.

g a

2 0.006.

O lik h Y U

0 400 000 1200 1600 2000

$E l 80 FREQUENCY IN H2 SPECS.05537 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Final-B1

-13V GEARBOX OUTPUT VERTICAL Date/ Time:

01-APR-93 16:58:08 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.48

.0039

.37 13 484.28

.0093 6.00 2

58.79

.0046

.73 14 707.61

.0095 8.77 3

80.69

.0162 1.00 15 726.25

.0048 9.00 4

161.45

.0075 2.00 16 766.73

.0042 9.50 5

206.36

.0079 2.56 17 1129.96

.0038 14.00 6

241.78

.0037 3.00 18 1415.29

.0030 17.54 7

323.13

.0090 4.00 19 1452.60

.0160 18.00 8

353.86

.0276 4.39 20 1533.33

.0043 19.00 9

403.67

.0054 5.00 21 1563.08

.0029 19.37 10 412.76

.0082 5.12 22 1886.83

.0029 23.38 11 442.20

.0026 5.48 23 1936.71

.0070 24.00 12 471.78

.0148 5.85 24 1946.10

.0036-24.12 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0499

.0065

/

2%

.0305

/ 37%

.0390

/ 61%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

9 CHRG - CHARG. PUMP B FINAL-B1

-14H GEARBOX OUTPUT HORIZONTAL

0. m i

SPECTRUM DISPLAY 01-APR-93 16:58 0.024 m $

OAD s g

i 3" : i;'h

- 0.018,

E b

A 0.012.

g n

E 0.006.

O ild

  1. dd o m i-b

[y$

0 400 000 1200 1600 2000 FREQUENCY IN H2 SPEC

.02085 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Final-B1

-14H GEARBOX OUTPUT HORIZONTAL Date/ Time:

01-APR-93 16:58:34 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.70

.0219 2.74 13 678.06

.0054 23.01 2

161.32

.0039 5.48 14 707.67

.0220 24.02 3

206.41

.0035 7.01 15 726.11

.0070 24.64 4

323.80

.0038 10.99 16 736.83

.0036 25.01 5

353.73

.0114 12.01 17 1371.71

.0035 46.55 6

359.61

.0035 12.20 18 1452.47

.0090 49.30 7

383.35

.0033 13.01 19 1533.14

.0054 52.03 8

403.56

.0032 13.70 20 1562.50

.0040 53.03 9

412.82

.0038 14.01 21 1592.10

.0031 54.03 10 471.63

.0071 16.01 22 1710.03

.0053 58.04 11 484.13

.0091 16.43 23 1739.47

.0035 59.04 12 619.03

.0030 21.01 24 1769.02

.0036 60.04 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS

' cdSYNCHRONOUS

.0438

.0085

/

4%

.0314

/ 52%

.0293

/ 45%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

CHtG - CHARG. PUMP B FINAL-31 -15A GEARBOX OUTPUT Ax!AL OM e-3 0.05,

PK =

.0770 e

LOAD = 100.0 0.04,

s a

0.03,

3 u

s g

e h 0.02,

k" 0.01.

O h 11 b u[ bank b

)$

0 400 800 1200 1600 2000 FREQUENCY IN HZ SPECS.00961 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Final-B1

-15A GEARBOX OUTPUT AXIAL Date/ Time:

01-APR-93 16:58:56 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.51

.0111 1.00 13 678.05

.0163 23.01 2

58.98

.0112 2.00 14 707.62

.0395 24.02 3

80.75

.0102 2.74 15 726.19

.0210 24.65 4

161.35

.0135 5.48 16 737.00

.0081 25.01 5

206.31

.0176 7.00 17 766.58

.0063 26.02 6

353.71

.0076 12.00 18 796.01

.0065 27.02 7

471.60

.0089 16.01 19 1452.66

.0277 49.30 8

484.10

.0167 16.43 20 1473.81

.0060 50.02 9

530.41

.0054 18.00 21 1532.97

.0122 52.03 10 589.56

.0063 20.01 22 1592.06

.0052 54.03 11 619.18

.0108 21.01 23 1613.60

.0081 54.76 12 648.09

.0117 22.00 24 1855.99

.0066 62.99 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0770

.0023

/

0%

.0605

/ 62%

.0476

/ 38%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit i

CHRG - CHARG PUMP B FINAL-B1 -16V PUMP INBD VERTICAL g, g el-APR-93 16 59 e.12..

PK =.1288 LOAD = lee.e a4: ::2b o

c. ie...

i

[ e.es.

ye.e6 g

.w e.

.:,, a s

M

$4N 8

e.ea.

Mc T Tw

-"-o

? Pao e. 3t Fl[$l soge e

4eo see sees 16ee eeee g

o ratoutncY IN HZ

$PECs le2 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Final-B1

-16V PUMP INBD VERTICAL Date/ Time:

01-APR-93 16:59:14 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.71

.1073 1.00 13 484.33

.0106 6.02 2

146.89

.0097 1.83 14 645.70

.0062 8.02 3

161.34

.0305 2.00 15 726.37

.0076 9.03 4

176.70

.0070 2.20 16 789.19

.0043 9.81 5

205.94

.0082 2.56 17 806.98

.0272 10.03 6

213.55

.0051 2.65 18 1371.82

.0058 17.05 7

223.36

.0067 2.78 19 1452.57

.0134 18.05 8

231.00

.0088 2.87 20 1533.37

.0041 19.05 9

242.33

.0191 3.01 21 1900.85

.0050 23.62 10 322.92

.0266 4.01 22 1908.53

.0046 23.72 11 403.54

.0083 5.01 23 1929.03

.0048 23.97 12 471.53

.0055 5.86 24 1936.74

.0133 24.07 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.1288

.0036

/

0%

.1208

/ 88%

.0447

/ 12%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

CHRG - CHARG. PUMP B FINAL-Bt -17H PUNP !NBD HORIZONTAL 040 g

01-APR-93 16:59

0. 24 <

OAD = 1 g

si

  • n'b o

9.18, F.

t h 0.12,

N 0.06 Sd g

$h b

e --M P-o 9---mn dTIo= M

$8 0

400 800 1200 1600 2000 FREQUENCY IN HZ

$PECs

.198 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Final-B1

-17H PUMP INBD HORIZONTAL Date/ Time:

01-APR-93 16:59:30 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.71

.2088 1.00 13 1371.91

.0208 17.05 2

136.13

.0069 1.69 14 1452.54

.0168 18.05 3

146.74

.0242 1.82 15 1533.23

.0185 19.05 4

161.19

.0072 2.00 16 1843.87

.0110 22.91 5

176.73

.0064 2.20 17 1853.13

.0085 23.03 6

188.52

.0060 2.34 18 1861.50

.0069 23.13 7

206.15

.0089 2.56 19 1869.25

.0083 23.23 8

242.06

.0207 3.01 20 1896.33

.0070 23.56 9

322.84

.0292 4.01 21 1905.86

.0067 23.68-10 403.61

.0092 5.02 22 1913.65

.0064 23.78 11 484.11

.0103 6.02 23 1936.59

.0116 24.06 12 807.15

.0061 10.03 24 1956.04

.0068 24.31 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.2255

.0281

/

2%

.2138

/ 90%

.0661

/

9%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc =QuitL

CHRG - CHARG. PUNP B FINAL-B1 -10A PUMP !NBD AXfAL 0.10 i

01-APR-93 16:59 DAD =}00 0.00 - A g

p, N: 3 0.06 E

C E

g e 04,

d i:i 3

S n

g

0. e2.

n n

0 L

'u F

8 400 800 1200 1600 2000 OR i

FREQUENCY IN H2 SPECS.0E017 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Final-B1

-18A PUMP INBD AXIAL Date/ Time:

01-APR-93 16:59:48 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE-1 80.71

.0719 1.00 13 1452.69

.0469 18.05 2

146.75

.0088 1.82 14 1533.31

.0227 19.05 3

161.69

.0233 2.01 15 1604.10

.0051 19.93 4

176.90

.0058 2.20 16 1614.57

.0156 20.06' 5

242.21

.0063 3.01 17 1628.54

.0056 20.24 6

322.79

.0134 4.01 18 1636.14

.0094 20.33 7

403.73

.0063 5.02 19 1654.20

.0063 20.56 8

484.13

.0112 6.02 20 1663.30

.0060 20.67 9

726.63

.0051 9.03 21 1671.44

.0072 20.77 10 806.65

.0086 10.02 22 1738.75

.0051 21.61 11 886.62

.0066 11.02 23 1776.04

.0053 22.07 12 1371.92

.0275 17.05 24 1936.90

.0118 24.07 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.1132

.0140

/

2%

.0855

/ 57%

.0729

/ 41%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

CH?G - CHARG. PUNP B

, !NAL-B1 r

-19V PUMP OUTBOARD YERTIC.R.

0.10 I SPECTRUM DISPLAY 91-APR-93 17:00 rg a.1202

.k 0.08.

LOAD = 100.0 a

6 RPM = 4829.

RPS = 80.47 0.06,

s a

'W h0.04 q

d I

=

r 0.62,

n b E M d G' T o m m m a i ' Yo C PM 0

$Ej!

4 80 I

0 400 000 1200 1600 2000 FREQUENCY IN H2 SPECt

.0.4 34 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Final-B1

-19V PUMP OUTBOARD VERTICAL Date/ Time:

01-APR-93 17:00:10 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.55

.0067

.37 13 220.25

.0036 2.74 2

59.01

.0045

.73 14 242.13

.0108 3.01 3

65.91

.0042

.82 15 294.05

.0049 3.65 4

80.67

.0790 1.00 16 308.26

.0037 3.83 5

88.49

.0434 1.10 17 322.92

.0138 4.01 6

116.94

.0055 1.45 18 471.67

.0067 5.86 7

126.17

.0048 1.57 19 484.26

.0286 6.02 8

131.95

.0174 1.64 20 616.65

.0038 7.66 9

146.76

.0421 1.82 21 646.19

.0038 8.03 10 161.36

.0577 2.01 22 806.80

.0035 10.03 11 176.83

.0101 2.20 23 1452.60

.0193 18.05 12 205.85

.0056 2.56 24 1938.42

.0042 24.09 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.1282

.0102

/

1%

.1034

/ 65%

.0750

/ 34%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit i

CHRG - CHARG. PUMP B r!NAL-31 -20H PUNP OUTBOARD FORi?ONTAL

  • I I

SPECTRUM DISPLAY 01-APR-93 17:00 0.i2 m.

S LOAD = 100.0

.{

$$ l 88 D 82 5

10 O

~

0.88.

3 t

5 0.06 0.04 E

E 0.02. $

n 0

k'JD hn m c 9 mm d

$E,

80 0

400 800 1200 1600 2000 FREQUENCY ]N H2 SPEC

.05035 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Final-B1

-20H PUMP OUTBOARD HORIZONTAL Date/ Time:

01-APR-93 17:00:22 Amplitude Units:

IN/SEC PK j

PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.69

.1034 1.00 13 322.77

.0042 4.01 2

100.94

.0045 1.25 14 388.29

.0030 4.82 3

110.33

.0129 1.37 15 484.09

.0228 6.02 4

123.98

.0035 1.54 16 498.64

.0033 6.20 5

131.80

.0056 1.64 17 558.66

.0030 6.94 6

138.64

.0048 1.72 18 601.79

.0037 7.48 7

146.68

.0345 1.82 19 616.51

.0045 7.66 8

161.40

.0667 2.01 20 645.72

.0081 8.02 9

176.52

.0056 2.19 21 726.40

.0044 9.03-10 205.55

.0035 2.55 22 807.04

.0068 10.03 11 242.04

.0105 3.01 23 1452.52

.0102 18.05 12 307.97

.0034 3.83 24 1533.29

.0104 19.05 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.1367

.0185

/

2%

.1258

/ 85%

.0503

/ 14%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

4 c""Si O RLL.=

r m-> i 01-APR-93 17:00 i

[6". i!fi 3:: fb 0.08 E

e.06 E

gj 0.04 5

~

A 0.02.

[

[

h JdY.E

_o e,9 m nnno no e,

FE 80 0

400 800 1200 1600 2000 FREGJENCY IN HZ SPEC 1.05635 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Final-B1

-21A PUMP OUTBOARD AXIAL Date/ Time:

01-APR-93 17:00:34 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.72

.0173 1.00 13 484.04

.0208 6.01 2

88.44

.0097 1.10 14 645.69

.0109 8.02 3

146.71

.0048 1.82 15 707.97

.0046 8.80 4

161.42

.0213 2.01 16 726.27

.0084 9.02 5

168.88

.0033 2.10 17 1452.64

.0858 18.05 6

176.97

.0037 2.20 18 1533.29

.0135 19.05 7

206.21

.0050 2.56 19 1886.13

.0038 23.44 8

236.13

.0032 2.93 20 1909.51

.0038 23.73 9

242.16

.0051 3.01 21 1928.43

.0044 23.96 10 322.98

.0067 4.01 22 1936.79

.0070 24.07 11 412.94

.0039 5.13 23 1946.32

.0040 24.19 12 471.56

.0085 5.86 24 1987.18

.0034 24.69 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.1021

.0190

/

3%

.0516

/ 26%

.0860

/ 71%

F1/ Enter = Accept F2= Paging is OFF F7= Title

_F9= Copy Esc = Quit

)

CHRG - CHARG. PUNP W FINAL-St

-22Y 01L PUMP 4tRTICtt 6M g

01-APR-93 17 00 L". in2,!

e.0, s een - 4 RPS. 80.47 E.

e.ea.

y na 8

isn d Y

N5}

y e.et.

d' d =Ro-

-ove o =19 e

I F

80 g 0

400 800 1200 1600 2000 FREQUENCY IN HZ SPECS.02588 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Final-B1

-22V OIL PUMP VERTICAL Date/ Time:

01-APR-93 17:00:54 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.69

.0272 1.00 13 242.17

.0121 3.01 2

88.46

.0117 1.10 14 249.40

.0030 3.10 3

93.97

.0035 1.17 15 256.21

.0014 3.18 4

111.14

.0021 1.38 16 278.69

.0014 3.46 5

117.15

.0065 1.46 17 308.33

.0023 3.83 6

125.70

.0016 1.56 18 322.83

.0029 4.01 7

133.42

.0019 1.66 19 454.69

.0019 5.65 8

146.76

.0104 1.82 20 483.95

.0031 6.01 9

161.'9

.0096 2.01 21 498.93

.0022 6.20 10 205.51

.0018 2.55 22 1452.57

.0046 18.05 11 227.40

.0025 2.83 23 1761.17

.0015 21.88 12 234.33

.0017 2.91 24 1774.39

.0020 22.05 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0383

.0028

/

1%

.0316

/ 68%

.0213

/ 31%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit ~

r!NAL-Bt 3H LR 120NTA e.87 i

SPECTRUM DISPLAY el-APR-93 17:e1 h

e e6 pg..e978 LOAD = lee.e n

RPM = 4829.

e.es,

Res - 88.47 l e.e4 s

f e.e3.

Y e.ee.

E e.ei.

b O

e - " " d """

e L r #uency '#*z U$!.$!!

LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Final-B1

-23H OIL PUMP HORIZONTAL Date/ Time:

01-APR-93 17:01:20 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.64

.0283 1.00 13 403.96

.0078 5.02 2

111.53

.0063 1.39 14 416.32

.0066 5.17 3

116.48

.0050 1.45 15 471.54

.0061 5.86 4

131.78

.0071 1.64 16 484.32

.0151 6.02 5

146.68

.0289 1.82 17 615.97

.0060 7.65 6

161.44

.0198 2.01 18 630.83

.0051 7.84 7

176.35

.0045 2.19 19 645.56

.0069 8.02 8

293.49

.0055 3.65 20 806.95

.0085-10.03 9

322.83

.0122 4.01 21 1371.96

.0051 17.05 10 353.03

.0049 4.39 22 1452.54

.0538 18.05 11 383.07

.0059 4.76 23 1533.26

.0225 19.05 12 390.82

.0064 4.86 24 1936.58

.0094 24.06 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0970

.0421

/ 19%

.0514

/ 28%

.0707

/ 53%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

o CHRG - CHARG. PUMP B

-B1 0R w 6 0.10 g

C I

[$nn".19090

0. 0a.

ra : :'*:S 5- 0.06 E

t 0.04 g

}

u E

"8 9.02.

~

g m.iF

'h

-J7. n c E_E PoY

[jl 0

0 400 800 1200 1600 2000 FREQUENCY IN HZ SPECS.02823 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Final-B1

-24A OIL PUMP AXIAL Date/ Time:

01-APR-93 17:01:34 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.70

.0297 1.00 13 630.83

.0080 7.84 2

88.50

.0083 1.10 14 645.74

.0096 8.02 3

146.71

.0185 1.82 15 659.55

.0041 8.20 4

161.41

.0316 2.01 16 678.77

.0035 8.43 5

176.44

.0056 2.19 17 707.57

.0087 8.79 6

206.25

.0040 2.56 18 726.47

.0159 9.03 7

308.15

.0040 3.83 19 807.17

.0049 10.03 8

322.94

.0075 4.01 20 1371.87

.0039 17.05 9

471.57

.0080 5.86 21 1452.59

.0740

-18.05 10 484.30

.0313 6.02 22 1533.31

.0082 19.05 11 568.71

.0041 7.07 23 1774.78

.0042 22.05 12 616.45

.0065 7.66 24 1936.66

.0067 24.07 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.1055

.0228

/

5%

.0648

/ 38%

.0800

/ 58%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy

-Esc = Quit

-i

0 o

FINAL-B1

-2 CEAR 0 'I Xf AL HIGH FREQ 0.12 1

SPECTRUM DISPLAY 01-APR-93 17 32

.1228 0, l e.

PK =

N LOAD = 100.0 j

5;: s'h o

0.08,

i I

0.06, o

3 d

8 R

h

0. 04,

h r

i N

e.e2 l

kaiwuukaa

[4)

O 0

kOOO 2000 3000 4000 5000 6000 FREQUENCY IN HZ SPECS.07931 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Final-B1

-25A GEARBOX INLET AXIAL HIGH FREQ Date/ Time:

01-APR-93 17:02:06 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.54

.0134 1.00 13 1855.83

.0084 62.99 2

59.24

.0125 2.01 14 1936.67

.0078 65.73 3

161.10

.0106 5.47 15 2096.09

.0104 71.14 4

206.25

.0133 7.00 16 2123.23

.0085 72.06 5

646.75

.0099 21.95 17 2180.49

.0094 74.00 6

678.13

.0200 23.01 18 2624.12

.0112 89.06 7

707.68

.0821 24.02 19 2771.60

.0079 94.07 8

726.58

.0449 24.66 20 2800.96

.0178 95.06 9

766.57

.0213 26.02 21 2830.56

.0179 96.07 10 796.40

.0146 27.03 22 2889.46

.0210 98.07 11 1452.64

.0160 49.30 23 2919.09

.0075 99.07 12 1532.96

.0084 52.03 24 3066.40

.0247 104.07 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.1228 Undefined /

0%

.1144

/ 87%

.0384

/ 10%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

o t

F

~26V PIPI HIGH FREQ

, INAL-B 0.08

  • ^

PK =

.0857 d

kW/!**6' 2

o 0.06 f

RPS = 80.47 O.05.

5 0.04 0.03, g

0. 02.

0.ei.

l

.o -

0 I

F 1000 2000 3000 4000 5000 O

FREQUENCY IN HZ SPEC 8.05439 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP B Meas. Point:

Final-B1

-26V PIPING HIGH FREQ Date/ Time:

01-APR-93 17:02.38 Amplitude Units:

7'/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY F2AK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

YALUE VALUE-1 1062.96

.0012 13.21 13 2488.15

.0053 30.92 2

1160.19

.0015 14.42 14 2613.39

.0066 32.47 3

1242.45

.0021 15.44 15 2742.72

.0053

.34.08 4

1377.41

.0053 17.12 16 2907.85

.0054 36.13 5

1452.61

.0548 18.05 17 2988.24

.0020 37.13 6

1611.01

.0079 20.02 18 3088.79

.0016

'38.38 7

1710.99

.0109 21.26 19 3139.77

.0014 39.02 8

1810.04

.0096 22.49 20 3387.50

.0012 42.09 9

1939.70

.0302 24.10 21 3871.91

.0030 48.11 10 2114.36

.0202 26.27 22 4134.01

.0013 51.37 11 2216.17

.0170 27.54 23 4214.05

.0015 52.36 12 2360.51

.0190 29.33 24 4356.87

. 0012 54.14 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0857 Undefined /

0%

Undefined /.0%

Undefined /

0%

F1/EnterrAccept F2= Paging is OFF F7= Title F9= Copy Esc = Quit:

i AUMILIARY BUILDING SPECTRA FROM MORE THAN ONE MACHIPE i

@ nYnooco__Tnnna9 i n - - r29 AP 24 g

SPAN 0.04 -

l 2-1 i

1

- 1 AP 9 03 f

9,,

ha 668 GPM-C2-16V g

S4

_I -

f-1 06-APR-93 07 50 a

IN!T!AL-C2-16V M_

_s.

1a 06-APR-93 05:30

.1 i_2

_a E'.N2 0

400 800 1200 1600 2000 i

3 FREQUENCY IN H2 SPC41 00293 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP C Meas. Point:

690 GPM-C2-16V PUMP INBD VERTICAL Date/ Time:

06-APR-93 08:24:30 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.72

.0028 1.00 13 311.57

.0033 3.87 2

118.18

.0039 1.47 14 484.43

.0070 6.02 3

148.15

.0039 1.84 15 646.30

.0030 8.03 4

161.43

.0207 2.01 16 726.48

.0031 9.03 5

188.73

.0037 2.35 17 789.03

.0032 9.81 6

199.16

.0047 2.48 18 807.89

.0032 10.04 7

214.03

.0046 2.66 19 886.67

.0033 11.02 8

221.30

.0032 2.75 20 968.70

.0067 12.04 9

231.48

.0055 2.88 21 1372.27

.0031 17.05 10 241.41

.0050 3.00 22 1453.11

.0149 18.06-11 286.10

.0032 3.56 23 1533.88-

'0062 19.06 12 293.51

.0051 3.65 24 1937.74

.0043 24.08 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0382

.0041

/

1%

.0248

/ 42%

.0288

/ 57%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit J

j i

AUX!L!ARY RUILDING SPECTRA FROM MOEC THAN ONE MACHINE I

a l

1 o o i-o m 9,4_9 m m,, n ?

9_m - - n p_.

96 AP 08 24 a

wm 0.08' d

1 i..

s 1.

O Ap 9 0 03 8

0-Y g

Jd 1

i

PUMP OUTBD VERTICAL Date/ Time:

06-APR-93 08:22:34 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.47

.0206

.37 13 176.55

.0036 2.19 2

58.90

.0229

.73 14 227.94

.0053 2.83 3

66.00

.0075

.82 15 231.45

.0042 2.88 4

80.75

.0458 1.00 16 242.04

.0082 3.01 5

88.37

.0123 1.10 17 293.60

.0051 3.65 6

103.55

.0031 1.29 18 310.91

.0030 3.86 7

111.09

.0044 1.38 19 484.51

.0153 6.02 8

118.01

.0528 1.47 20 531.11

.0033 6.60 9

128.82

.0042 1.60 21 726.72

.0050 9.03 10 138.58

.0043 1.72 22 1453.45

.0038 18.06 11 147.83

.0147 1.84 23 1534.16

.0041 19.06 12 161.52

.0645 2.01 24 1938.05

.0050 24.08 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.1064 0321

/

9%

.0802

/ 57%

.0621

/ 34%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

a 4

m AUXILIARY IdJ!LDING

$PCCTRA FROM MORE THAN ONE MACH!NC E

690 GPM-C2-20H

__Aon-m--mn-m-----m-----m 06-APR-93 08s22 SPAN 0.30 -

686 GPtt-C2-20H g

._J 06-APR-93*90:03 8

0 660 GPM-C2-20H g

i 06-APR-93 07:49 INITIAL-C2-20H 3

06-APR-93 05:30

$E$

((

0 400 000 1200 1600 2000 TREQUENCY IN HZ SPC4:

.288 I

l i

LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP C Meas. Point:

690 GPM-C2-20H PUMP OUTBOARD HORIZONTAL Date/ Time:

06-APR-93 08:22:51 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.75

.2876 1.00 13 461.30

.0027 5.73 2

98.74

.0049 1.23 14 471.38

.0051 5.86.

3 104.34

.0077 1.30 15 483.84

.0137 6.01 4

118.15

.0119 1.47 16 631.29

.0035 7.85 5

133.99

.0085 1,67 17 646.20

.0026 8.03 6

147.14

.0111 1.83 18 708.33

.0046 8.80 7

161.54

.0406 2.01 19 726.69

.0081 9.03 8

182.96

.0029 2.27 20 807.29

.0030 10.03 9

190.34

.0030 2.37 21 968.88

.0035 12.04 10 242.22

.0097 3.01 22 1453.37

.0034 18.06 11 323.11

.0038 4.02 23 1534.13

.0026 19.07 12 403.44

.0029 5.01 24 1937.82

.0034 24.08 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.2930

.0121

/

0%

.2904

/ 98%

.0369

/

2%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy

-Esc = Quit

AUMILIARY BUILDIKU SPCCTRA FROM MORE THAN ONE f% CHINE 4

_79 9b9em__,,mm$9mm,,mo u

9 06 23 p

PLOT e

SPAN

8. 030 <

f LJ 1

ap 9 8 05

.1 t

5, 0,,

3 11 j ab k

f49 q

.gpg

. n lL}

}

f31 n

2 2 I

0 400 000 1200 1600 2000 OR 3

FREQUENCY IN H2 SPC4

.00697 LIST OF SPECTRAL PEAKS

                                          • w Machine:

(CHRG) CHARG. PUMP C Meas. Point:

690 GPM-C2-21A PUMP OUTBOARD AXIAL Date/ Time:

06-APR-93 08:23:04 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.50

.0092

.37 13 441'.80

.0028 5.49 2

58.98

.0080

.73 14 458.81

.0029 5.70 3

80.72

.0070 1.00 15 471.54

.0050 5.86 4

88.55

.0034 1.10 16 484.21

.0149 6.02 5

117.99

.0138 1.47 17 646.42

.0050 8.03 6

147.12

.0036 1.83 18 707.98

.0081 8.80 7

161.47

.0136 2.01 19 736.80

.0030 9.16 8

242.13

.0058 3.01 20 768.27

.0039 9.55 9

308.99

.0032 3.84 21 807.29

.0042 10.03 10 323.01

.0038 4.01 22 1453.28

.0079 18.06 11 426.59

.0027 5.30 23 1534.00

.0031 19.06 12 433.17

.0026 5.38 24 1937.74

.0026 24.08 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0392

.0142

/ 13%

.0233

/ 35%

.0282

/ 52%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit i

AUX!LIARY BUILDING SPECTRA FROM MORE THAN ONE MACHINE E3 h

PLOT

~

}

SPCtt

e. s4 -

b 680 GPM-C2-26V g

06-APR-93 " 08 03 8

0,

[

06-APR-93 07:50 660 GPM-C2*26V g

L

$E[ I M

-3 31 0

1000 2000 3000 4000 5000 6000 FREQUENCY IN HZ SPC48.02966 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP C Meas. Point:

690 GPM-C2-26V PIPING HIGH FREQ Date/ Time:

06-APR-93 08:23:28 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

1372.09

.0031 17.05 13 2417.32

.0357 30.04 2

1452.98

.0297 18.06 14 2541.02

.0071 31.58 3

1532.95

.0027 19.05 15 2612.73

.0062-32.47' 4

1608.45

.0029 19.99 16 2662.66

.0045 33.09 5

1688.66

.0076 20.99 17 2743.14

.0044 34.09 6

1809.01

.0059 22.48 18 2833.01

.0035 35.21 7

1939.58

.0182 24.10 19 2909.10

.0061 36.15 8

2011.01

.0156 24.99 20 2964.85

.0034 36.85 9

2091.99

.0218 26.00 21 3062.69

.0038 38.06~

10 2185.47

.0144 27.16 22 3218.99

.0018 40.00 11 2259.18

.0283 28.08

-23 3385.68

.0014 42.08 12 2342.55

.0224 29.11 24 3879.91

.0016 48.22 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0765 Undefined /

0%

Undefined /

0%

Undefined /

0%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

m

, _ _ _ _. = _, _..

CHRG - CHARG. PUMP C

!NITIAL-Cl-tv MOTOR OUT30ARD vrRTICAL-06-APR-93 05419 n..0000 ATI itd' m

0. 0.

a RPS = 29.40 n

=

3 0.004,

C 8

i s-9 n

t 0.00a,

g 7,

n e

n

  • 19Te'OEU
  1. SP W --- '

0 O

200

. 400 640 000 1000 FREQUENCY IN HZ SPECS.00467 LIST OF SPECTRAL-PEAKS Machine:

(CHRG) CHARG. PUMP C-Meas. Point:

Initial-Cl-1V _ -->

MOTOR OUTBOARD VERTICAL.

Date/ Time:

06-APR-93 05:19:10 Amplitude Units:

IN/SEC PK

-PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER.-

NO.

(Hz)

VALUE-VALUE NO.

(Hz)

VALUE' VALUE 1

5.64

.0008

.19 13 359.77

.0014 12.24 2

10.77 4.66E-04

.37-14 413.05-

.0009 14.05

+

3 29.51

.0052 1.00 15 472.05

.0011 16.06 4

59.05

.0006 2.01 16 480.14 3.47E-04

16. 3 3 ~.

5 80.75 4.19E-04 2.75 17

'484.50

.0014 16.48 6

89.03

.0010 3.03

_18 531.06

.0009

-18.06 7

119.93

.0041 4.08 19 569.77

~3.'61E-04 19.38 8

180.12 3.51E-04 6.13 20 619.58 3.56E-04 21.08 9

236.01 4.09E-04 8.03 21 645.92 3.27E-04' 21.97-10 239.78 3.99E-04 8.16 22-678.57.

4.47E-04 23.08' 1 11 323.04 4.88E-04 10.99 23 708.09

.0022 24.09 12 354.04

.0012 12.04-

-24 807.40-4.94E-04 27.46 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS.

NONSYNCHRONOUS

.0080

.0011

/

'2 %

.0059

/ 54%

.0053./ 44%

i

.F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit-i 1

l

~l 1

1

-1

CHRG - CHARG. PUMP C INITIAL-Cl-2H MOTOR OUTBOARD HORIZONTAL 0.010 i

SPECTRUN DISPLAY 06-APR-93 05119 L'a i'A'i 0.0 e 0

g RPM = 1764.

u c'

RPS = 29.40 O.006 m 3

9 k

g 0.004 m

h

<d 0.002.

0 4

'i#

b N

"c'bce' - '

'h.$

O 200 400 600 800 1000 FREQUENCY IN HZ spgg:

,pg,7 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP C Meas. Point:

Initial-Cl-2H MOTOR OUTBOARD HORIZONTAL Date/ Time:

06-APR-93 05:19:33 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.50

.0050 1.00 13 359.80

.0070 12.24 2

58.28

.0016 1.98 14 383.48

.0006 13.05 3

90.41

.0007 3.08 15 472.06 3.92E-04 16.06 4

119.92

.0061 4.08 16 484.51

.0008 16.48 5

179.91

.0013 6.12 17 531.11

.0006 18.07 6

206.56

.0008 7.03 18 565.29 4.99E-04 19.23 7

236.09

.0008 8.03 19 590.16 4.04E-04 20.08 8

239.8'4

.0026 8.16 20 619.58 4.63E-04 21.08 9

295.10

.0010 10.04 21 646.00

.0006 21.98 10 323.11

.0019 10.99 22 678.62

.0006 23.09 11 344.36 4.18E-04 11.71 23 708.13

.0021 24.09 12 354.10

.0007 12.05 24 807.56 4.18E-04 27.47 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0131

.0054

/ 17%

.0066

/ 25%

.0100

/ 58%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit I

1

CHtG - CHARG. PUrP C 1 NI T Ist.-C 1-3A MOTOR OUTBO@D Ax! AL g

06*APR-93 05819

.PK

. 0.e. 0

=

064

. i g ' **' -

i

=: R*;

s

0. 004,

U 9

8 3;

g o

~

g 0.eGa n

k oit

~,hed9~ _

g 0

200 400 600 000 2000 FREQUENCY IN H2

$PLCl.00274 LIST OF SPECTRAL PEAKS Machine:

(CHHG) CHARG. PUMP C Meas. Point:

Initial-Cl-3A MOTOR OUTBOARD AXIAL Date/ Time:

06-APR-93 05:19:47 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.50

.0030 1.00 13 236.09

.0005 8.03 2

59.07

.0005 2.01 14 239.73 3.02E-04 8.16 3

80.82

.0005 2.75 15 295.13 3.03E-04 10.04 4

89.35

.0007 3,04 16 323.01

.0005 10.99 5

98.10 3.28E-04 3.34 17 353.99

.0006 12.04 6

119.93

.0052 4.08 18 359.78 2.95E-04 12.24 7

139.62 3.15E-04 4.75 19 383.49

.0006 13.05 8

161.58 2.91E-04 5.50 20 389.30 3.24E-04 13.24 9

179.73

.0011 6.11 21 403.49 2.86E-04 13.73 10 190.87 3.27E-04 6.49 22 413.11

.0006 14.05 11 197.04 2.96E-04 6.70 23 649.11 3.49E-04 22.08 12 206.61

.0009 7.03 24 708.11 4.34E-04 24.09 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0084

.0048

/ 34%

.0043

/ 27%

.0053

/ 40%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

'l N

~

1 CHRG - CHARG. PUMP C IMITIAt-C1-4v Mot 0R INBOARD vtRf! CAL 06-APR-93 05:20 m 0.02.

s

.OADm'50

.. im.

A RPS w 29.40 n

g E

e 0.008,

g e

S e 0. = i

?

l n

n n

n o

k m

mTb l g

0 200 400 600

- 800 1990

((

FREQUC Cf IN HZ SPECS.06335 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP C Meas. Point:

Initial-Cl-4V MOTOR INBOARD VERTICAL Date/ Time:

06-APR-93 05:20:16 Amplitude Units:

IN/SEC-PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER 1 NO..

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE.

1 10.78

.0014

.37 13 589.93

.0015.

20.07 2

29.50

.0037 1.00 14 619.53

.0017 21.08-3 58.99

.0016 2.01 15 646.81

.0032 22.00-4 88.46

.0011 3.01 16 649.02

.0068 22.08 5

119.66

.0012 4.07 17 678.50

.0027 23.08-6 323.06

.0016 10.99 18 708.01

.0123

'24.09 7

354.00

.0040 12.04 19 726.64

-.0013.

24.72 i

8 359.74

.0011

'12.24 20 737.50

.0021 25.09 9

413.04

.0025 14.05 21 767.01

.0025 26.09 10 472.00

.0036 16.06 22 796.51

.0013 27.10-11 484.40

.0032 16.48 23 807.36

.0033 27.47i 12 530.99

.0014 18.06 24 968.85

.0010 32.96 i

TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS;

.0185

.0023 '/.2%

.0084

/ 20%

.0163L / 78%

s

, -F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit-4

e CFRG - CH4RG. PUNP C IMiticd_-C I-5H MOTOR IMBOARD HORIZONTAL 0.010 06-APR-93 05:21

.0132 PK =

0.000,

Long. 100.0 u

RPM = 1764 g

g RPS = 29.40 1

A 8.006,

r e

Y.

h 0.004 I e

d d

0

~

E

e. 0e2.

l n c'n n

is n

Ys J s".

d,0.

I m n_1 g

M iPst 0

200 400 600 000 1000 FREQUENCY IN H2 SPECS.00359 LIST OF SPECTRAL PEAKS Machines :

(CHRG) CHARG. PUMP C Meas. Point:

Initial-Cl-5H MOTOR INBOARD HORIZONTAL Date/ Time:

06-APR-93 05:21:17 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.51

.0040 1.00 13 413.11

.0011 14.05 2

59.02

.0019 2.01 14 472.11

.0010 16.06 3

88.96

.0018 3.03 15 484.51

.0023 16.48 4

119.97

.0043 4.08 16 590.14

.0010 20.08 5

179.93

.0015 6.12 17 619.61

.0017 21.08 6

239.84

.0026 8.16 18 646.03

.0023 21.98 7

295.07

.0016 10.04 19 648.31

.0012 22.05 8

323.15

.0019 10.99 20 678.66

.0024 23.09 9

354.12

.0017 12.05 21 708.14

.0073 24.09 10 359.80

.0017 12.24 22 737.64

.0015 25.09 11 383.49

.0015 13.05 23 767.16

.0010 26.10 12 403.82

.0015 13.74 24 807.55

.0018 27.47 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0132

.0025'

/

3%

.0070

/ 28%

.0109

/ 68%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

CHRG ~

gntTIM.-C1 4 o" p

  • t.
0. 008 ' T DM SPECiguM DIS M 06 APR.93 05820 PK

.0116

=

u 8.006

." 6k p

g RPS = 29.ed s

r n

8" e.w4.d C

o in 8

)d 9

? ".,

y 0.082.

l iTP D, %

e m,,t, i

N Qs 2.00 0

200 400 600 000 1000 h

rREQUENCY IN H2 gpg LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP C Meas. Point:

Initial-Cl-6A MOTOR INBOARD AXIAL Date/ Time:

06-APR-93 05:20:44 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.53

.0039 1.00 13 484.48

.0025 16.48 2

59.03

.0020 2.01 14 531.04

.0025 18.07 3

80.85

.0008 2.75 15 565.25

.0023 19.23 4

88.39

.0011 3.01 16 590.10

.0016 20.07 5

119.87

.0048 4.08 17 619.56

.0008 21.08 6

147.66

.0008 5.02 18 645.92

.0011 21.97 7

177.17

.0010 6.03 19 678.60

.0008 23.08 8

191.73

.0007 6.52 20 708.07

.0046 24.09 9

240.33

.0006 8.18 21 726.72

.0010 24.72 10 354.04

.0012 12.04 22 737.55

.0007 25.09 11 359.77

.0015 12.24 23 796.58

.0007 27.10 12 472.07

.0011 16.06 24 807.43

.0014 27.47 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0116

.0048

/ 18%

.0059

/ 26%

.0087

/ 57%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

CHRG - CHARG. PUNP C INITIAL-C1-7V GEARBOX INPUT VERTICAL g,,g 06-APR-93 05:21 PK =.0226 p's if.'!%?

0.02.

m RPS

  • 29.46 n

E h.

s'

~

0 g

g

.808 u g p

d d

d w

g g

t 0.e84 m 9

IJ f l

i. l El ___

d M

[$

0 400 000 1200 1600 2000 FREQUENCY IN HZ SPEC 1.06413 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP C Meas. Point:

Initial-Cl-7V GEARBOX INPUT VERTICAL Date/ Time:

06-APR-93 05:21:41 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

8.77

.00 0

.30 13 484.33

.0076 16.44 2

29.52

.0042 1.00 14 678.68

.0027 23.03 3

58.96

.0046 2.00 15 708.03

.0115 24.03 4

80.74

.0075 2.74 16 807.38

.0015 27.40-5 161.44

.0017 5.48 17 885.92

.0024 30.07 6

206.60

.0018 7.01 18 968.88

.0026 32.88 7

242.10

.0025 8.22 19 1130.38

.0018 38.36 8

265.54

.0014 9.01 20 1180.10

.0015 40.05 9

295.15

.0017 10.02 21 1416.14

.0018 48.06 10 323.18

.0052 10.97 22 1453.35

.0047 49.33 11 354.03

.0058 12.02 23 1475.17

.0027 50.07 12 472.05

.0027 16.02 24 1937.81

.0019 65.77 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0226

.0033

/

2%

.0176

/ 61%

.0137

/ 37%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

CHRG - CHARG. PUMP C INITIAL-Cl-OH GC#,RBOX INPUT HOR!20Nfs4.

g 06-APR-93 05:21 GAi. 40 0.024 m

e

.PN. im.

g RPS. 29.45 A

~

" 8.018,

s t

g

0. 0 2.

g i

?

e g

i 0.e06.

9- $

f>LmIn 1 15" J

'=*

I S

400 000 1200 1600 2000 FREQUENCY IN H2 SPEC

.00154 1

LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP C Meas. Point:

Initial-Cl-8H GEARBOX INPUT HORIZONTAL Date/ Time:

06-APR-93 05:21:55 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VAL'7E VALUE 1

58.91

.0045 2.00 13 708.01

.0192 24.03 2

80.75

.0043 2.74 14 737.43

.0028 25.03 3

161.51

.0063 5.48 15 767.14

.0020 26.04 q

4 176.97

.0025 6.01 16 796.51

.0022 27.03 5

294.69

.0022 10.00 17 807.35

.0055 27.40 6

323.27

.0031 10.97 18 968.87

.0024 32.88 7

354.22

.0032 12.02 19 1416.04

.0034 48.06

)

8 383.66

.0026 13.02 20 1453.28

.0081 49.32 9

471.73

.0033 16.01 21 1504.63

.0026 51.07 10 484.38

.0082 16.44 22 1534.04

.0054 52.06 11 648.22

.0040 22.00 23 1614.83

.0028 54.81 12 678.55

.0033 23.03 24 1622.38

.0021 55.06 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0303

.0076

/

6%

.0240

/ 62%

.0170

/ 31%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit i

i

O CHRG - CHARG. PUMP C INITIAL-Cl-94 GEARBOX INPUT Ax!AL 0.%

SPECTPUN DISPLAY 06-APR-93 05:22 0.05.

PK =.0675 m

LOAD = 100.0 j

RPM = 1768.

o p

RPS = 29.46 g

E D

E r

0.03.

m 8

=

y e.02 4 3

I f

4 0.01,.

n 9

n! a - ' 1 'l'f All IAd 0

400 000 1200 1600 2000 FREQUCNCY IN HZ SPECI.01111 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP C Meas. Point:

Initial-Cl-9A GEARBOX INPUT AXIAL Date/ Time:

06-APR-93 05:22:08 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.56

.0113 1.00 13 619.54

.0060 21.03 2

59.00

.0190 2.00 14 648.79

.0112 22.02 3

80.74

.0343 2.74 15 678.47

.0099 23.03 4

88.54

.0073 3.01 16 707.97

.0401 24.03 5

118.11

.0033 4.01 17 726.58

.0083 24.66 6

147.56

.0032 5.01 18 737.53

.0076 25.03 7

161.46

.0079 5.48 19 766.81

.0039 26.02 8

242.17

.0039 8.22 20 796.46

.0041 27.03 9

472.19

.0042 16.03 21 807.33

.0136 27.40 10 484.34

.0086 16.44 22 968.75

.0035 32.88 11 531.16

.0027 18.03 23 1445.29

.0036 49.05 12 564.82

.0027 19.17 24 1453.22

.0120 49.32 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0675

.0042

/

0%

.0517

/ 59%

.0431

/ 41%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit l

l

,+. -..

... ~,. -

. ~.

2 CHRG - CHARG. PUMP C

, INITIAL-C1-10V GEARBOX OIL P/P VERTICAL OM 06-APR-93 05122 L. 2 *:

0.015 m y

i

: it':a a

0.012 s

g R

n

  • h 0.000,

0.004,

i:

n

,khJi t dw tidj.d bNgM 0

400 000 1290 1600 2900 l

f[

FREQUENCY IN H2 SPECS.00443 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP C Meas. Point:

Initial-Cl-10V GEARBOX OIL P/P VERTICAL Date/ Time:

06-APR-93 05:22:26 Amplitude Units:

IN/SEC. PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY

PEAK

-ORDER' NO.

(Hz)

VALUE VALUE

'NO.

(Hz)

VALUE

~VALUE; 1

29.48

.0046 1.00 13 796.60

.0025 27.10 2

59.00

.0061 2.01 14 807.45

.0053.

27.47 3

80.75

.0142 2.75 15 885.36

.0029 30.12 4

161.48

.0031 5.49 16 968.93

.0029 32.96 5

206.63

.0023 7.03 17 1150.60

.0024 39.14 6

323.17

.0060 10.99 18 1416.14

.0042 48.17:

7 354.09

.0105 12.05 19

-1453.42

.0050 49.44 i

8 471.65

.0023 16.04 20 1475.25

.0053 50.19:

9 484.44

.0075 16.48 21 1504.59

.0039 J51.18 10 708.07

.0093 24.09 22 1593.10

.0039 54.19 11 726.77

.0023 24.72 23 1615.16

.0024

'54.95 12 737.59

.0040 25.09 24 1711.18

.0026 58.21 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS-

.0302

.0027

/.1%

.0193

/,41%

.0231. /:58%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit 3

I t

r.o e

m..

y*,,#..

~.,..

.c,-

p

,w-

~.

., ~ -

.-q C W - CHARG. PUMP C

.l IMIT!st-Cl-11H GEARBOX O!L P/P HORIZONTAL I

SPECTRUN DISPLAY 06-APR-93 05822.

i "sais ifa 9.03,

RPM = 1764 u

RPS =- 29.40

_A.

5 I

4 0.02 g

5 SI E

g i

n I

f.

3 0.01.

nd 2 y

I ' '8L 2--I 1 IJ' e Fh:4 8

I 0'

400

- 800 1200 1600 2000 ap FREQUENCY IN HZ SPECI.00121 LIST OF SPECTRAL PEAKS a

Machine:

(CHRG) CHARG. PUMP C ii Meas. Point:

Initial-Cl-11H- -->

GEARBOX OIL P/P HORIZONTAL -

Date/ Time:

05-APR-93 05:22:41 Amplitude. Units:

IN/SEC PK i

PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE

_VALUE 1

80.73

.0147 2.75 13 726.93

.0028 24.73 2

118.15

.0042 4.02 14 737.71

.0041 25.10 3

161.52

.0329 5.49 15 767.17

.0028-26;10 4

177.06

.0046 6.02 16 796.73

.0030 27.10 5

242.19

.0035 8.24 17 807.64

.0063 27.47.

6 323.22

.0049 11.00 18 1180.26

.0034 40.15 7

354.16

.0040 12.05 19 1453.73

.0073 49.45 8

383.73

.0033 13.05 20 1475.52

.0029 50.19 9

471.95

.0034 16.06 21 1504.82

.0031 51.19 10 484.58

.0092 16.48 22 1534.51

.0058 52.20 I

11 678.75

.0027 23.09 23 1615.05

.0033 54.94 12 708.24

.0149 24.09 24 1938.35

.0029 65.94 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0459

.0014

/

0%

.0188

/. 17%

.0418

/ 83%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit-.;

i

.I

,w a

~..

.l

- Canc - CsaRo. etPe C INITIAL-Cl-12A GEMBW O!L P/P AX!AL

9. 6 i

SPECTRtm DISPLAY 06-APR-93 05:22

~

PW =

.0697 I

0.04 e

g Loan 10e.0 y

i E i;"6

- 1 0.03,

E

'O a

g * *= 1 t:

a 5

n v

E I

a 1

0.01 A i

n s

O C

i r3 g h i

.1 unum i Edlu ib 6

400 800 1200 1600 2000 FREQUENCY IN HZ SPECt.01044 i

LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP C l

Meas. Point:

Initial-Cl-12A GEARBOX OIL P/P AXIAL -

Date/ Time:

06-APR-93 05:22:55 Amplitude Units:

IN/SEC PK.

PEAK FREQUENCY PEAK ORDER

-PEAK FREQUENCY PEAK

. ORDER' NO.

(Hz)

VALUE VALUE NO.

-(Hz)-

VALUE VALUE 1

29.49

.0107 1.00 13 531.14

.0147 18.07 2

59.03

.0179 2.01 14 565.21

.0064 19.23 3

80.80

.0365 2.75 15 619.66

.0055 21.08 4

88.62

.0072 3.01 16 645.35

.0058 21'.95:

5 161.54

.0060 5.50 17 649.76

.0061 22.10 6

206.42

.0065 7.02 18 678.71

.0082 23.09 7

242.26

.0071 8.24 19 708.19

.0377 24.09 8

323.26

.0053 11.00 20 726.88

.0081 24.73 9

354.14

.0090 12.05 21 737.73

.0079 25.10' 10 383.59

.0052 13.05 22 767.25

.0053 26.10 11 471.88

.0057 16.05 23 807.63'

.0071 27.47 12 484.58

.0162 16.48 24 1888.58

.0045 64.25 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS-

.0697

.0037

/

0%

.0466 '/ 45%

.0517

/ 55%~

- F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy

~

Esc = Quit

+

7

.m,

  • mr

--,yer--

+

==

s'

CmG - CHARG. PUMP C INITIAL 41-13V GEARBOX OUTPUT VERTICAL OM 06-APR-93 05:23

.0519 PK =

n LOAD = 100.0 u

0.03.

RPM = 1764 p

sf RPS = 29.40 5

r 4

N

[

0.02

,m i

1 8

c.

Y d

g 0.01.

d:

c p

i 5

MPdI)1sM ma nLe b e u.'

0 F

0' 400 800 1200 1600 2000 OR s 0

FREQUEttCY IN H2 SPECS

.00296 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP C Meas. Point:

Initial-Cl-13V GEARBOX OUTPUT VERTICAL Date/ Time:

06-APR-93 05:23:22 Amplitude Units:

IN/SEC.PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.53

.0030 1.00 13 708.32

.0278 24.10 2

59.01

.0039 2.01 14 727.01

.0039 24.73 3

80.77

.0163 2.75 15 737.82

.0062 25.10 4

161.53

.0089 5.49 16 767.42

.0033 26.11 5

323.32

.0102 11.00 17 796.88

.0044 27.11 6

354.13

.0203 12.05 18 807.74

.0093 27.48 7

413.16

.0061 14.06 19 969.' 4

.0047 32.97

/

8 442.76

.0034 15.06 20 1180.54

.0044 40.16 9

472.14

.0070 16.06 21 1416.61

.0048 48.19 10 484.55

.0089 16.48 22 1446.10

.0036 49.19 11 531.23

.0063 18.07 23 1453.88

.0179 49.46 12 678.85

.0037 23.09 24 1475.62

.0075 50.20 i

TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0519

.0047

/

1%

.0357

/ 47%

.0373

/ 52%

t/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit j l

4.

0.05 3

SPECTRUM Di$ PLAY 06-AP9-93 05:23 0

OAD=500 s

'04 -

2 "A : s"a h

0.03.

5 m

k 8 0.0a a Y"

8 g

o s

9.01,

e ge J IN d--

a 0

';W

-al "6

$f 0

400 OAO 1200 1600 2000 FREQUCNCY IN HZ

$PEC8

.00094 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP C Meas. Point:

Initial-Cl-14V GEAftBOX OUTPUT HORIZONTAL Date/ Time:

06-APR-93 05:23:34 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.78

.0159 2.75 13 531.21

.0032 18.07 2

118.01

.0042 4.01 14 648.31

.0063 22.05 3

161.54

.0344 5.50 15 678.68

.0047 23.09 4

176.86

.0045 6.02 16 708.30

.0213 24.10 5

206.58

.0023 7.03 17 726.89

.0040 24.73 6

242.28

.0040 8.24 18 737.79

.0056 25.10 7

295.02

.0025 10.04 19 767.44

.0026 26.11 8

323.26

.0056 11.00 20 796.74

.0034 27.10 9

354.07

.0059 12.05 21 807.71

.0057 27.48 10 383.54

.0039 13.05 22 1453.87

.0058 49.46 11 472.02

.0036 16.06 23 1505.32

.0027 51.21 12 484.66

.0086 16.49 24 1534.81

.0026 52.21 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0511

.0120

/

6%

.0239

/ 22%

.0435

/ 73%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

O

. PUNP C INITIAL-C 53 4 T ARBOX OUTpyy 4xg4L 0.10 1

SPECTRON DISPLAY 06.feg.93 05:23

,y "i

PK =.1994 0.00.

C:1%*

g n

U RPS

  • 29.40 9.06,

E C

a h

0.04,,k q,

N*

r

  • 4 0.02 q

6 90 he

. h htbud ALL. ilun-I O

400 000 1200 1600 2000 ca t B

FREQUENCY IN H2 SPECS.00520 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP C Meas. Point:

Initial-Cl-15A GEARBOX OUTPUT AXIAL Date/ Time:

06-APR-93 05:23:49 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK. FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.49

.0053 1.00 13 648.15

.0239 22.05 2

59.02

.0191 2.01 14 678.73

.0148 23.09 3

80.75

.0370 2.75 15 708.32

.0800 24.10 4

88.45

.0081 3.01 16 726.88

.0114 24.73 5

147.55

.0048 5.02 17 737.85

.0241 25.10 6

161.53

.0087 5.50 18 767.33

.0125 26.10 7

206.63

.0070 7.03 19 796.88

.0080 27.11 8

242.30

.0060 8.24 20 807.72

.0194 27.48 9

484,70

.0141 16.49 21 1180.48

.0108 40.16 10 531.18

.0095 18.07 22 1416.59

.0063 48.19 11 565.44

.0057 19.24 23 1453.90

.0148 49.46 12 619.76

.0109 21.08 24 1593.67

.0050 54.21 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.1094

.0037

/

0%

.0792

/ 52%

.0754

/ 47%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

CWG - CHARG. PUMP C INITIAL-Cl-16V PUMP !NBD VERT!Ctt OM i

SPECTRUM DISPLAY 06-APR-93 0$324 9

PK =.0485 o 0.03..

=

2 RPS e 80,47 E

5

e. 02.

n g

9 6

g"!

g g

0.01.

n n

T g b

--n onnel "C

$E[i 80 0

400 000 1290 1600 2000 FREQUENCY IN H2 SPEC 8.02979 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP C Meas. Point:

Initial-Cl-16V PUMP INBD VERTICAL Date/ Time:

06-APR-93 05:24:05 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PUAK ORDER PEAK FREQUENCY PEAK ORDER No.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.79

.0318 1.00 13 323.37

.0024 4.02 2

118.17

.0044 1.47 14 484.41-

.0079 6.02 3

147.26

.0036 1.83 15 565.45

.0023 7.03 4

161.51

.0224 2.01 16 645.77

.0025 8.02 5

188.75

.0042 2.35 17 708.77

.0025 8.81 6

200.53

.0051 2.49 18 776.68

.0029 9.03 7

206.63

.0063 2.57 19 7 8 ti. 3 9

.0028 9.77 8

218.26

.0040 2.71 20 809.54

.0025 10.05 9

228.82

.0056 2.84 21 969.26

.0035 12.04 10 242.01

.0081 3.01 22 1373.04

.0028 17.06 11 288.55

.0045 3.59 23 1453.82

.0110 18.07 12 306.82

.0027 3.81 24 1534.56

.0044 19.07 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0485

.0028

/

0%

.0409

/ 71%

.0259

/ 29%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit i

1

CHRG - CwdtG. PUMP C 0.10

~

l SPCCTRUM DISPLAY 06-AFR-93 05:24 a

'08 -.

CAD =i 0

": ::n a
e. es.

3 h

0.04 e rv g

d5

0. e2.

In g

e L)bN9 bi d---

o e m., - L

$Ed 8h8d 0

400 000 (200 1600 2000 ME M T! IN H2 SPECt.07528 LIST OF SPECTRAL PEAKS

                  • =************

Machine:

(CHRG) CHARG. PUMP C Meas. Point:

Initial-Cl-17H PUMP INBD HORIZONTAL Date/ Time:

06-APR-93 05:24:17 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.77

.0800 1.00 13 256.20

.0029 3.18 2

131.06

.0044 1.63 14 323.05

.0046 4.01 3

138.99

.0042 1.73 15 403.59

.0036 5.02 4

146.95

.0165 1.83 16 471.73

.0028 5.86 5

161.55

.0482 2.01 17 484.67

.0084 6.02 6

176.56

.0054 2.19 18 646.29

.0090 8.03 7

183.75

.0038 2.28 19 708.37

.0041 8.80 8

188.93

.0036 2.35 20 807.56

.0045 10.03 9

198.48

.0039 2.47 21 969.08

.0044 12.04 10 204.19

.0031 2.54 22 1373.03

.0062 17.06 11 231.35

.0078 2.87 23 1453.75

.0124 18.06 12 242.23 00^5 3.01 24 1534.53

.0095 19.07 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.1026

.0063

/

0%

.0963

/ 88%

.0350

/ 12%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit l

CHRG - CHARG. PUMP C INITIAL-CI-18A PUNP !NED Ax!AL 0.29 i

06-APR-93 05:24 i

L. is:':

0. m a
: : ::*b 0.12,

E C

~

h

0. 08,

Y g

n 0.04,,9d

{

n h

I

~,

.l u p c.~ VT Y o m9., m m n

. 7%m 9 e

r 80 0

400 800 1200 1600 2000 FREQUENCY IN HZ spggi,gj950 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP C Meas. Point:

Initial-Cl-18A PUMP INBD AXIAL Date/ Time:

06-APR-93 05:24:33 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.78

.0208 1.00 13 925.98

.0056 11.51 2

118.03

.0061 1.47 14 931.46

.0041 11.57 3

147.23

.0065 1.83 15 969.11

.0063 12.04 4

161.50

.0262 2.01 16 1372.94

.0217 17.06 5

241.40

.0049 3.00 17 1416.16

.0037 17.60 6

323.29

.0037 4.02 18 1446.23

.0039 17.97 7

484.55

.0135 6.02 19 1453.69

.1716 18.06 8

565.58

.0056 7.03 20 1534.48

.0099 19.07 9

646.16

.0090 8.03 21 1646.40

.0038 20.46 10 708.48

.0G45 8.80 22 1655.67

.0040 20.57 11 726.78

.0087 9.03 23 1665.94

.0047 20.70 12 806.99

.0045 10.03 24 1938.34

.0043 24.09 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.1809

.0050

/

0%

.0483

/

7%

.1742

/ 93%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

CHRG - CW.RG. PUMP C INITIAL-Cl-19V ' PUMP OUTBD VOtTIC A 0.20 06-APR-93 05:24 it. ;g*:

0. a.

y g.

74: M*b 0.12.

E g

0.08 J

0.04 a

=

In-9m-m-__--=*---

e L F

0 400 000 1290 1600 2000 OR FREQUENCY IN H2 SPEC 3 126 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP C Meas. Point:

Initial-Cl-19V PUMP OUTBD VERTICAL Date/ Time:

06-APR-93 05:24:58 Amplitude Units:

IN/SEC PK.

PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE No.

(Hz)

VALUE VALUE-1 29.53

.0070

.37 13 161.46

.0510 2.01 2

59.01

.0039

.73 14 178.36

.0025 2.22 3

65.98

.0043

.82 15 228.24

.0033 2.84 4

80.75

.1332 1.00 16 241.84

.0031 3.01 5

86.29

.0133 1.07 17 293.61

.0034 3.65 6

95.73

.0039 1.19 18 322.91

.0028 4.01' 7

103.89

.0034 1.29 19 484.37

.0128 6.02 8

118.04

.0423 1.47 20 531.09

.0025 6.60 9

126.17

.0035 1.57 21 565.33

.0029 7.02 10 131.40

.0036 1.63 22 726.86

.0043 9.03 11 136.34

.0030 1.69 23 1453.55

.0031 18.06 12 147.12

.0160 1.83 24 1534.42

.0034 19.07 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.1523

.0102

/

0%

.1429

/ 88%

.0516

/ 12%.

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

CHRG - CHARG. PUPP C INITIAL-Cl-P0H PUMP OUTPOARD HORI2ONTAL 0.35 i

SPECTRUM DISPLAY 06-# R-93 05:25 0.30,,A PK

.2724

=

f LOAD = 100.0 g 0.25 3 3" : O h

0.20 3

0.15.

W 0.10, 9

0.05 i

8 n

~

O 9e fmn9m-n--

-nmon----

0 0

400 000 1200 1600 2000 oppe

,994 FREQUENCY IN HZ SPECS

.252 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP C Meas. Point:

Initial-Cl-20H PUMP OUTBOARD HORIZONTAL Date/ Time:

06-APR-93 05:25:15 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.75

.2674 1.00 13 453.68

.0028 5.64 2

103.36

.0083 1.28 14 461.23

.0029 5.73 3

110.4J

.0036 1.37 15 478.56

.0099 5.95 i

4 118.13

.0081 1.47 16 484.20

.0142 6.02 5

130.85

.0048 1.63 17 566.27

.0043 7.04 6

133.96

.0045 1.66 18 571.80

.0026 7.11 7

147.78

.0064 1.84 19 631.20

.0053 7.84 8

161.55

.0388 2.01 20 646.29

.0036 8.03 9

176.81

.0033 2.20 21 707.84

.0034 8.80 10 242.30

.0092 3.01 22 716.51

.0024 8.90 I

11 323.07

.0060 4.01 23 726.65

.0094 9.03 12 401.68

.0026 4.99 24 807.71

.0023 10.04

)

TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.2724

.0050

/

0%

.2702

/ 98%

.0341

/

2%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit-

CHRG - CHARG. PUMP C

! NIT!4.-Cl-21A Pt.MP OUTBOARD AXT AL

0. M 06-APR-93 05:25 OAD={0 0 9.03.,g RFM = 4829.

ug RPS a 80.47 g

et 0.02,

.[

N y

0. 0 i.

g

)&

L.,,, _ 64 9

00 00 0'

400 000 1200 1600 2000 FREQLENCY IN HZ SPECI.02652 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP C Meas. Point:

Initial-Cl-21A PUMP OUTBOARD AXIAL Date/ Time:

06-APR-93 05:25:45.

Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.53

.0046

.37 13 464.03

.0024 5.77 2

58.94

.0040

.73 14 471.14

.0031 5.85 3

80.75

.0281 1.00 15 484.56

.0097 6.02 4

88.49

.0035 1.10 16 646.44

.0055 8.03 5

117.98

.0115 1.47 17 708.12

.0055 8.80 6

147.10

.0042 1.83 18 726.73

.0047 9.03 7

161.53

.0112 2.01 19 738.06

.0022 9.17 8

228.23

.0025 2.84 20 766.49

.0024 9.52 9

242.33 0046 3.01 21 786.15

.0028 9.77 10 322.93

.0044 4.01 22 796.38

.0026 9.90 11 404.00

.0034 5.02 23 807.72

.0041 10.04 12 441.83

.0028 5.49 24 1453.54

.0073 18.06 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0428

.0113

/

7%

.0336

/ 62%

.0238

/ 31%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

CHRG - CW Ka. PUMP C INITIAL-Cl-22V O!L PUMP VERTICAL 06-APR-93 05:26 PK =

.0638 LOAD = 100.0 0.04 y

y

P1 : :**b 0.03.

5 Eg 0.02.

Y r

9 g

0. 0.

9 JP

=m"99-C---'

1 rREQ M. 00 0

400 800 1200 1600 2000 ORDRs

.994 FREQUCNCY IN H2 SPEC

.03395 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP C Meas. Point:

Initial-Cl-22V OIL PUMP VERTICAL Date/ Time:

06-APR-93 05:26:21 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

29.47

.0012

.37 13 242.27

.0072 3.01 2

58.89

.0014

.73 14 249.51

.0069 3.10 3

66.07

.0024

.82 15 264.33

.0018 3.28 4

80.75

.0360 1.00 16 293.55

.0009 3.65 5

95.98

.0012 1.19 17 322.93

.0030 4.01 6

103.90

.0021 1,29 18 440.28

.0015 5.47 7

118.05

.0377 1.47 19 455.29

.0010 5.66 8

131.43

.0020 1.63 20 587.21

.0013 7.30 9

146.82

.0332 1.82 21 726.58

.0013 9.03 10 161.49

.0066 2.01 22 807.39

.0010 10.03 11 227.56

.0033 2.83 23 1372.61

.0011 17.06 12 234.66

.0022 2.92 24 1453.33

.0011 18.06 TOTAL MAG SUBSYdCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0638

.0036

/

0%

.0373

/ 34%

.0517

/ 65%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

rnirr*-c'lW 'R%"'&,,,,

j e.ee

$PCCTpgpg gggpLgy e6

  • R-93 05:26

% ;. D ';

.. a,

y

(

"A : ::'b 5

a.ne.

5 t

y e.es,

N n

r e.e4 Tj E

I 5

Inm om$9_m-m_m m9---

e m

' ge seg d

e 4ee see tese 1600 aeee rat =cnev in a secc:

334 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP C Meas. Point:

Initial-Cl-23H OIL PUMP HORIZONTAL Date/ Time:

06-APR-93 05:26:35 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

80.75

.1419 1.00 13 403.87

.0030 5.02 2

103.43

.0027 1.29 14 440.84

.0043 5.48 3

118.13

.0046 1.47 15 455.97

.0039 5.67 4

131.95

.0034 1.64 16 484.14

.0188 6.02 5

146.90

.0059 1.83 17 493.33

.0028 6.13 6

161.47

.0368 2.01 18 564.61

.0026 7.02 7

228.31

.0047 2.84 19 631.41

.0028 7.85 8

242.32

.0118 3.01 20 708.56

.0026 8.80 9

293.53

.0054 3.65 21 726.63

.0073 9.03 10 323.01

.0058 4.01 22 807.29

.0071 10.03 11 374.00

.0043 4.65 23 1534.17

.0063 19.06 12 393.11

.0038 4.88 24 1938.21

.0041 24.08 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.1527

.0197

/

2%

.1486

/ 95%

.0291

/

4%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit

?

CHRG - CHARG. PUMP C N!TMt-fu mN6 0.06 i

SPCCTRUM DISPLAY 06-APR-93 05:26 0.05 PK =.0675 2

2"/it' e

g RPS e.

80.47 5

E 8.03.

Q s

  • a' li, 22 r

0.01.

n g a:!m L e

too_o_ col

'i' a - -.

I 80 0

400 000 1200 1600 2000 OR FREQUENCY IN HZ SPECl.01753 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP C Meas. Point:

Initial-Cl-24A OIL PUMP. AXIAL Date/ Time:

06-APR-93 05:26:53 Amplitude-Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

'VALUE VALUE:

1 80.77

.0187 1.00 13 618.71

.0045' 7;69 2

118.04

.0098 1.47 14 631.20

.0047.L 7.84 3

147.14

.0127 1.83 15'

-645.33

.0090 8.02

.4 161.47

.0433 2.01 16 676.41

.0032 8.41 5

308.30

.0031 3.83 17 708.06

.0117.

8.80 6

323.10

.0048 4.01-18 713'.98

.0033 8.87 7

484.30

.0149 6.02 19 726.78

.0142 9.03.

8 531.22

.0047 6.60 20 738.29

.0031 9.17 9

564.85

.0058 7.02 21 766.66

.0040 9.53 10 575.93

.0030 7.16 22 788.61

.0030.

9.80-11 583.61

.0041 7.25 23 807.32

.0075 10.03 12 593.96

.0049 7.38 24 1453.33

.0242

'18.06.

TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS.

NONSYNCHRONOUS

.0675'

.0132

/

4%

.0529

/ 61%

.0399

/.35%

F1/ Enter = Accept F2= Paging is OFF' F7= Title

- F9= Copy Esc = Quit:

f

..,,w,.-..

.l

.n

..n,..+

..u.

._an,

+

>,,~.. ~.

.~.

. ~ - - - -... ~

,..., ~. -

j CFRG - CHARG, PUMP C 0*" INITIAL-Cl-2SA GEARDOX INLET AXIAL HIGH FREQ i

SPECTRUM DISPLAY.

96-APR-93. 05:27 0.05.

.003 PK.

Lo e ies.4 6

A : i;'b.

g"..

~

3 i

..3.

=

8 i

y e.ea n I

n n

0.98.

EB g

e d

a hb M k

I

$Cjl hh O

tese 2006 3000 4000 FREQUENCY IN HZ SPEC 8.83341 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP C Meas. Point:

Initial-Cl-25A GEARBOX INLET AXIAL HIGH FREQ Date/ Time:

06-APR 05:27:22 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY

' PEAK

. ORDER NO.

(Hz)

VALUE VALUE NO.

'(Hz)

VALUE-VALUE' 1

29.59

.0112 1.00 13 807.47.

.0135

.27.40 2

59.03

.0193 2.00 14 1452.36

-.' 014 5.

'49.29 l

3 80.67

.0336 2.74 15 2832.09

.0041 96.12-'

4 160.97

.0076 5.46 16 2890.99

.0117'

'98.12 1

5 241.62

.0039 8.20 17 2920.50

.0277 99.12 6

484,79

.0102 16.45 18 2950.19-

.0206 100,13 7

619.35

.0070 21.04 19 2979.62

.0175 101.12' 8

648.77

.0082 22.02 20 3009.28

.0085' 102.13 9

678.58

.0103 23.03 21 3038.50

.0126 103.12 10 707.93

.0408 24.03 22 3068.13

.0146 104.13 11 726.33

.0091 24.65 23 3127.21

.0116 106.13 12 735.34

.0080 24.96 24 3156;62

.0038 107.13 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS' NONSYNCHRONOUS l

.0834 Undefined /

0%

.0778

/ 87%

.0271

/ ~ : Esc = Qui 11%

l.F1/ Enter = Accept F2= Paging is OFF F7= Title.

F9= Copy i

l i

5 g

-w'*

'4 Y

'l l

CWtG - CHARG. PUMP C INIT!AL-C2-26V P! PING HIGH FPCQ OAD=50 d

;355 1

j 5

g 9.02.

g 0.01,

g C

N e

i

  • 2

-w-F l

I 1000 2000 3000 4000 5000 OR 8

FREQUENCY IN HZ c4TCt.02307 LIST OF SPECTRAL PEAKS Machine:

(CHRG) CHARG. PUMP C Meas. Point:

Initial-C2-26V PIPING HIGH FREQ Date/ Time:

06-APR-93 05:31:44 Amplitude Units:

IN/SEC PK PEAK FREQUENCY PEAK ORDER PEAK FREQUENCY PEAK ORDER NO.

(Hz)

VALUE VALUE NO.

(Hz)

VALUE VALUE 1

1258.59

.0010 15.64 13 2513.20

.0012 31.23 2

1374.28

.0035 17.08 14 2659.44

.0013 33.05 3

1453.32

.0254 18.06 15 2744.46

.0052 34.11 4

1539.43

.0039 19.13 16 2822.43

.0015 35.08 5

1660.75

.0043 20.64 17 2909.95

.0014 36.16 6

1809.28

.0022 22.48 18 2963.45

.0009 36.83 7

1935.40

.0052 24.05 19 3066.66

.0006 38.11 8

2033.69

.0041 25.27 20 3390.20

.0007-42.13 9

2110.85

.0036 26.23 21 3471.01

.0010 43.14 10 2235.88

.0080 27.79 22 3792.03

.0006 47.13 11 2341.35

.0184 29.10 23 3876.22

.0010 48.17 12 2417.36

.0046 30.04 24 4358.99

.0007 54.17 TOTAL MAG SUBSYNCHRONOUS SYNCHRONOUS NONSYNCHRONOUS

.0362 Undefined /

0%

Undefined /

0%

Undefined /

0%

F1/ Enter = Accept F2= Paging is OFF F7= Title F9= Copy Esc = Quit u

V. C. SUN 151ER Cl{ARGING / SAFETY INJECTION PL'.\\1P RUNOUT FLOW EVALUATION (Rev. 2)

ATTACHNIENT 4 Cil/SI PUNIP PERFORN1ANCE CURVES This attachment contains Head / Flow performance curves for all three CH/SI pumps. These curves include data recorded during procedure STP-230.006A overplayed with the vendor's shop test curves.

I 1

racm su::M

4 i

V.C. SUMMER CH/SI PUMP A PUMP PERFORMANCE CURVES 7000 gg"~~~-e z %_ _ _

v

-A h

'A x

m Z 5000' 2N - --

a

-x g

x Z 4000

- - N--

w

.,M y3 4m

- - - +g 3 3000

=-

~2000

0-100 200-300 400 500 600-700 800 FLOW RATE (gpm)

Runout Test Data, Best Fit.Line.e Original Vendor Curve n

9 y

,,y

~

--c v

3 c

,. r u%,.

i V.C. SUMMER CH/SI PUMP B PUMP PERFORMANCE CURVES 7000 4

3 A'

~..- --.

~ - - - -..

- - -. ~.. - -

a x

4 As W

s Z 5000

-N --

J

^xs H

's Z 4000 Y

W 8

g 3000

-k

\\

l 2000

-0 100 200 300 400 500 600 700 800 FLOW RATE (gpm)

Runout Test Data, Best Fit Line 3 Vendor Curve No. 36897 Spare a

V.C. SUMMER CH/SI PUMP C PUMP PERFORMANCE CURVES 7000 2 6000 6-

+-

a x

w t --- -

Z 5000 N

a x

4

s.,

I n

Z$m

-._ x _

m

\\

  • m 3 3000

--- - - g--

2000 0

100 200 300 400 500 600 700 800 FLOW RATE (gpm)

Runout Test Data, Best Fit Line

,s Original Vendor Curve a

V, C. SUN 15f ER CHARGING j SAFETY INJECTION PUMP RUNOUT FLOW EVALUATION (Res 2)

ATTACHMENT 5 "AS FOUND" PUMP IIEAD/ FLOW DATA The tables in this attachment were taken from Reference 3, and are the source of the "as found* pump performance data which was plotted in the graphs of Attachment 4.

r aonn um

Charging Pump B - Head Curve & Run-out Test IIDR SEAL OIG PUMP liFAD SUCT DISCII IIDR CllG LINE ILOW INJ FLOW FLOW Fr PRESS PRESS PRESS PRESS TEMP GPM ILOW GPM GPM PSIG PSIG PSIG PSIG DEG F GPM 100 15 N/A 115 6374 17.1 2765 74.81 N/A 92.74 179 27 N/A 206 6264 16.8 2720 172.5 N/A 84.39 286 26 N/A 312 5886 16.7 2557 390 N/A 79.71 378 25 N/A 402 5271 16.5 2290 652.5 N/A 75.98 482 26 N/A 508 4469 15.8 1940 1003.1 N/A 73.43 585 25 N/A 610 3472 15.4 1505 1475.6 N/A 71.39 585 25 N/A 610 3472 15.4 1505 1475.6 N/A 71.39 497 27 87 611 3594 15.4 1558 1055.8 1051.9 70.39 497 27 88 612 3599 15.5 1560 1056.6 1050 70.42 510 26 89 626 3473 15.3 1505 1112 1108 70.04 522 29 94 644 3167 15.4 1372 1202.3 1200

%5 522 29 94 M5 3167 15,4 1372 1202.2 1198.1 69.47 533 29 96 657 3030 15.2 1312 1248.6 1246.9 69.18 535 29 108 672 2935 15.2 1270 1239.9 1237.5 69.1 536 29 109 673 2930 15.2 1268 1237.5 1235.6 69.1 531 28 118 678 2889 15.2 1250 1220.4 1215 69.14 525 28 136 689 2807 15.1 1214 1182.9 i !!77.5 69 516 27 155 698 2725 15 1178 1145.6 1138.1 69 510 27 171 708 2M6 14.9 1143 1111.9 1102.5 68.9

1 Charging Pump A - Run-out Test IIDR SEAL CIIG PUMP IIEAD SULT DISCII IIDR LINE

'I FLOW INJ FLOW FLOW Fr PRESS PRESS PRESS TEMP GPM FLOW GPM GPM PSIG PSIG PSIG DEG F GPM 602 27 N/A 629 3577 15.3 1550 1464 69.23 1

575 N/A 92 666 3267 15 1414 1338.75,

68.64

~

565 N/A 111 676 3176 15 1374 1299.4 68.87 555 N/A 133 688 3036 14.9 1313 1255.3 69 544 N/A 155 699 2966 14.8 1282 1211.25 69 535 N/A 174 708 2882 14.8 1245 1173.75 69.2 551 N/A 139 691 3053 14.8 1320 1250 70 535 N/A 171 706 2902 14.85 1254 1181.25 69.2 i

i l

)

'l Charging Pump C - Run-out Test IIDR SEAL CllG PUMP llEAD SULT DISCll IIDR LINE ILOW INJ ILOW 110W FT PIESS PRESS PRESS TEMP GPM FLOW Gl%i GPM PSIG PSIG PSIG DEG F GPM 596 26 N/A 622 3428 14.7 1485 1421.25 69.02 555 N/A 111 666 3051 14.6 1320 1256.25 69.16 542 N/A 136 679 2937 la.6 1270 1201.88 69.19 533 N/A 155 688 2846 14.4 1230 1162.5 69.22 523 N/A 173 6%

2754 14.4 1190 1122 69.22